36C26018Q0265-A00001002.xlsx

XLSX spreadsheet 11 KB Posted

Attached to
WSNC Medical Bottled Gases BPA
Solicitation number
36C26018Q0265
Issued by

About this file

36C26018Q0265 A00001 Attachment B - Services for Govt Owned Tanks.xlsx

View the file

Other files

File Type Posted
36C26018A0063-000.docx DOCX document
36C26018A0064-000.docx DOCX document
36C26018Q0265-A00006000.docx DOCX document
36C26018Q0265-A00006001.xlsx XLSX spreadsheet
36C26018Q0265-A00005000.docx DOCX document
36C26018Q0265-A00004000.docx DOCX document
36C26018Q0265-A00004001.xlsx XLSX spreadsheet
36C26018Q0265-A00003000.docx DOCX document
36C26018Q0265-A00002000.docx DOCX document
36C26018Q0265-A00001000.docx DOCX document
36C26018Q0265-A00001001.xlsx XLSX spreadsheet
36C26018Q0265-003.xlsx XLSX spreadsheet
36C26018Q0265-001.docx DOCX document
36C26018Q0265-002.xlsx XLSX spreadsheet
36C26018Q0265-000.docx DOCX document
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

SERVICES NOT INCLUDED IN PRICE OF GAS FOR GOVERNMENT OWNED CYLINDERS
When required, the contractor shall perform additional services as described below.
All materials and components shall be furnished by the contractor.
Parts, Including Replacement
Description
Valve
Dip(siphon) tube including retreating
Collar
Valve hood
Safety device cap
Outlet cap or plug, plastic
Outlet cap or plug with relating chain and clip
Frangible disc
Fusible plug in valve
Fusible plug in cylinder
Valve stem
Valve packing
Striping and Painting
Description
Grit blast or Caustic Strip, Prime and Paint - one color
Grit blast or Caustic Strip, Prime and Paint - each additional color
Wire brush and Paint, incl. Primer - one color
Wire brush and Paint, incl. Primer - each additional color
Stenciling, Miscellaneous for tanks not requiring repainting
Hydrostatic testing, indenting, new test date, drying interior and resetting valve
Modified Hydrostatic testing, where permitted by regulation
Visual inspection in lieu of hydrostatic testing where permitted by DOT
Dehydrating cylinders, except in conjuction with hydrostatic testing
Internally clean cylinders prior to hydrostatic tests, to include purge, cleaning and drying
Internally clean contaminated cylinders as required by applicable specifications
Removal of fractured, rusted, or damaged cylinder caps, valves or plugs
Stamping valve with name of gas, when required by ordering activity

Sheet2

Sheet3

File details come from the government source that posted it.