36C25926Q0636.docx
DOCX document 20 KB Posted
- Solicitation number
- 36C25926Q0636
About this file
This is a Sources Sought Notice issued by the Department of Veterans Affairs Network Contracting Office 19 for market research purposes regarding Water System Chemical Treatment Services at the VA Salt Lake City Health Care System (George E. Wahlen VA Medical Center). The notice is not a solicitation or binding commitment and responses cannot be accepted to form contracts. The solicitation number is 36C25926Q0636, with a response deadline of July 22, 2026, at 2:00 PM Mountain Time. The product service code is H946 (water treatment and distribution), with a NAICS code of 221310 and a small business size standard of $41 million.
The Government seeks contractors to provide two primary services: routine water system chemical testing, monitoring, maintenance, and treatment services including softener salt supply and delivery; and critical parts, chemical supply (excluding routine salt resupply), troubleshooting services, and unscheduled maintenance and repairs. The requirement includes bi-weekly onsite testing and servicing visits, 12-hour onsite response for service calls, and 12-hour emergency chemical delivery capability. Responses must include company information, business size classification, licensing and firm qualifications specific to Utah water treatment, personnel technical qualifications (including chemist or chemical engineer with B.S. degree and industry certifications), and documentation of how logistics and response-time requirements will be met. Responses should not exceed eight pages and must be submitted via email to Contracting Officer John Cheng (John.Cheng2@va.gov) by the stated deadline. Proprietary information should be clearly marked.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Statement of Work - SOW.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| Water System Chemical Treatment Services for the VA Salt Lake City UT |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 80111 |
| SOLICITATION NUMBER* |
| 36C25926Q0636 |
| RESPONSE DATE/TIME/ZONE |
| 07-22-2026 14:00 MOUNTAIN TIME, DENVER, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| H946 |
| NAICS CODE* |
| 221310 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office
NCO 19
6162 South Willow Drive, Suite 300 Greenwood Village CO 80111
POINT OF CONTACT*
Contracting Officer John Cheng John.Cheng2@va.gov 303-712-5776
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
VA Salt Lake City Health Care System
George E. Wahlen VA Medical Center
500 Foothill BLVD
Salt Lake City UT
| POSTAL CODE |
| 84148 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
| AGENCY CONTACT’S EMAIL ADDRESS |
| John.Cheng2@va.gov |
| EMAIL DESCRIPTION |
| John Cheng |
DESCRIPTION
Sources Sought Notice - Water System Chemical Treatment Services Disclaimer:
This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Information Requested from Industry:
1) In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.
2) Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.
Description of Requirement:
The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Water System Chemical Treatment Services for the VA Salt Lake City Health Care System (SLCHCS). This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.
Services:
| Item No. |
| Item Description |
| 1 |
| Routine Water System Chemical Testing, Monitoring, Maintenance Treatment Services and Plant Softener Salt supply & delivery in accordance with the Statement Of Work (SOW). |
| 2 |
| Critical parts, supply of chemicals (not routine salt resupply for softeners), and troubleshooting services & testing for unscheduled maintenance (not preventive maintenance) and repairs in accordance with the SOW. |
In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met:
Company Name:
Address:
SAM UEI (Unique Entity ID) Number:
Business Size Information - Select all that applies:
· Small Business
· Emerging Small Business
· Small Disadvantaged Business
· Certified under Section 8(a) of the Small Business Act
· HUBZone
· Woman Owned
· Certified Service-Disabled Veteran Owned Small
· Veteran Owned Small Business
· Large Business
Federal Acquisition Regulation (FAR) Market Rearch Questions:
Questions for Small Businesses ONLY:
Limitations on Subcontracting RFO 52.219-14
1. What percentage of the work would be subcontracted to another company? ________
2. What is the business size of the subcontractor?______
Per RFO 52.219-14 the following conditions must be met:
Services (except construction), it will not pay more than 50 percent of the amount paid by the Government for contract performance to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract;
Supplies (other than procurement from a nonmanufacturer of such supplies), it will not pay more than 50 percent of the amount paid by the Government for contract performance, excluding the cost of materials, to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both supplies and services, the 50 percent limitation shall apply only to the supply portion of the contract;
3. If subcontracting, what added value does your firm offer:
4. Licensing & Firm Qualifications:
Is your firm currently registered with the Utah Division of Occupational and Professional Licensing (DOPL) in a classification applicable to water treatment/mechanical services? (Please provide a copy of the current license/registration.)
How long has your firm been providing industrial water treatment services (boiler, cooling tower, RO/DI, closed loop systems) on a continuous contract basis? (Please provide the number of years)
5. Personnel Technical Qualifications:
Does your firm employ a chemist or chemical engineer, holding a B.S. degree in chemistry, chemical engineering, or a closely related field, to oversee technician work?
Does this individual hold an industry certification such as Certified Water Technologist (CWT) through AWT, or an AMPP/NACE Corrosion Technologist certification? (Please attach a copy of the degree/transcript and the professional certification. If a different equivalent certification is held, please identify it and attach a copy.)
Do your field technicians hold a recognized water treatment certification (e.g., AWT technician-level certification, manufacturer-issued training certificate, or state-recognized operator certification)? (Please attach a sample copy of the certification(s))
6. Responsiveness & Logistics (Onsite Technician Frequency / Resupply):
This requirement includes bi-weekly onsite testing/servicing visits, 12-hour onsite response requirement for service calls, along with a 12-hour emergency chemical delivery capability. If your firm is not based in the Utah area, how would your firm be able to meet these frequency and response-time requirements?
Response Instructions:
1. Do not provide more than 8 pages, including cover letter page.
1. Submit your response via email to John.Cheng2@va.gov
1. Submit your response NLT 14:00 (MST) on Wednesday, July 22, 2026;
1. Mark your response as “Proprietary Information” if the information is considered business sensitive.
1. VA has identified the appropriate North American Industry Classification System (NAICS) Code as 221310 - Water treatment and distribution with a Small Business size of $41 Million. Please identify and explain any NAICS codes your company believes would better represent the predominant work based on the attached Statement of Work (SOW).
(End of Sources Sought) See attached document: Statement of Work - SOW.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .