This is a Sources Sought Notice issued by the Department of Veterans Affairs Network Contracting Office (NCO) 19 for ceiling mounted patient lifts at the Oklahoma VA Health Care System. The procurement seeks a contractor to provide and install patient lift systems with X/Y axis coverage, capable of transferring patients between rooms without additional equipment. The requirement is classified under NAICS code 423450 for Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers, with an SBA size standard of 200 employees.

Key details include a response deadline of August 22, 2025 at 4:00 PM Mountain Time, a four-month performance period, and a preference for American manufacturing. Performance requirements mandate compliance with safety codes, national electrical codes, and NFPA standards. Contractors must submit a capability statement addressing organizational capacity, including point of contact information, business size status, and supporting documentation. The VA may set aside the procurement for small businesses or proceed with full and open competition, with the potential for multiple awards. Interested vendors should respond via email to the contract specialist, Shanta Harrison, with a comprehensive capability statement.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
OKC RAD Patient Lift System EXPEDITED RESPONSES REQUESTED

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
80111
SOLICITATION NUMBER*
36C25925Q0748
RESPONSE DATE/TIME/ZONE
08-22-2025 4:00pm MOUNTAIN TIME, DENVER, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
423450
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office

NCO 19

6162 South Willow Drive, Suite 300 Greenwood Village CO 80111

POINT OF CONTACT*

Contract Specialist Shanta Harrison Shanta.Harrison@va.gov

(303) 712-5719

PLACE OF PERFORMANCE

ADDRESS
Oklahoma VA Health Care System

921 NE 13th St

Oklahoma City OK

POSTAL CODE
73104
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov/
URL DESCRIPTION
US Department of Veterans Affairs Homepage

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

DESCRIPTION

The Department of Veterans Affairs Network Contracting Office (NCO) 19, Oklahoma VA Health Care System is issuing this Sources Sought Notice as a means of conducting market research to identify parties having an interest in, and the resources to support this requirement for CEILING MOUNTED PATIENT LIFTS for the Oklahoma VA Health Care System located at 921 NE 13th St, Oklahoma City, OK 73104. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 423450 Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers; SBA Size Standard 200 Employees.

This is a request for information and sources only, which may or may not lead to a future solicitation! This is not a solicitation. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. Contractor shall provide all labor, parts, supplies and equipment necessary to perform CEILING MOUNTED PATIENT LIFTS. Services shall include but are not limited to the following:

Objective: Furnish qualified personnel, materials, equipment, and services necessary to install ceiling mounted patient lifts. Ceiling mounted lifts must be able to have an X/Y axis and ability to transfer from one room to another room such as from patient room into patient bathroom without transfer of patient into an additional device. American manufacturing is requested, pursuant to the Buy American Act.

Performance Requirements

A. The overhead mounted patient lifts provided by the contractor shall meet all lift safety codes, national electrical codes, National Fire Protection Association codes and all other applicable federal, state, and local codes. Tracks must provide X/Y coverage (full room coverage) in each room selected for lift installation to provide lifting assistance throughout the entire room. The contractor shall be responsible for installing all lifts without relocation of lights, HVAC grills, curtain tracks, IV tracks and sprinkler heads.

Additional requirements include but are not limited to the following:

- Entire lift system (not just the charger) should be UL-listed and a certificate of such presented for review. Provide equipment information for each unit like pictures of the different slings, tool kit for easy use of the equipment, and any other pertinent information on equipment.

- Disclosure of all Tort claims against vendor either pending or resolved regarding proposed system.

- Disclosure of history of all recalls

- Education/Training Plan for Bio-Medical Engineer and employees

The Period of Performance for this requirement is Four (4) months, beginning at date of award.

BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION, and multiple awards MAY be made. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. SUBMISSION INSTRUCTIONS: If your organization can provide these services and is interested in this opportunity, please respond to Shanta Harrison, Contract Specialist, Department of Veterans Affairs, NCO 19 via e-mail at Shanta.Harrison@va.gov with a statement describing your capabilities. The capability statement shall include a primary point of contact, complete mailing address, telephone number, email address, state the company’s business size status and should address this specific requirement, with appropriate documentation supporting claims of organizational and staff capability. Please be as thorough as possible in your submission, and include information on any multiple award schedule contracts your company holds. Requests for copies of a solicitation will not be honored or acknowledged. Expedited responses are requested. The deadline for responses is Friday, August 22, 2025 at 04:00 PM mountain time.

*= Required Field