This is a Sources Sought Notice from the VA Network Contracting Office seeking information from vendors who can provide and install view stations and port switches at the Sheridan VA Medical Center in Wyoming. The response deadline is February 17, 2025 at 13:00 MST, with responses limited to 8 pages and submitted via email to charles.olise@va.gov. The NAICS code is listed as 339112 with a size standard of 1000 employees.

The VA seeks to award a fixed-price contract for 2 Milestone view stations (BCDSF01-ELWS-I5-T10), 3 Axis T8524 PoE+ 24-port switches, and related equipment to enhance employee accountability and patient safety. The system must be compatible with the existing Sheridan VAHCS Gallagher system. Requirements include one-year maintenance and support, three-hour onsite response time, certified technicians with Gallagher Security and Milestone certifications, complete installation services, and system training. The vendor must also provide software updates, documentation, and ensure future integration capability between Gallagher and Milestone systems. Work must be scheduled outside normal VA hours (0730-1600) when possible to minimize disruptions.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
View Stations and Port Switches

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
80111
SOLICITATION NUMBER*
36C25925Q0195
RESPONSE DATE/TIME/ZONE
02-17-2025 13:00 MOUNTAIN TIME, DENVER, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6350
NAICS CODE*
334290
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office

NCO 19

6162 South Willow Drive, Suite 300 Greenwood Village CO 80111

POINT OF CONTACT*

Contract Specialist Charles Olise Charles.olise@va.gov 801-582-1565 x 3902

PLACE OF PERFORMANCE

ADDRESS
VA Sheridan Health Care

Sheridan VA Medical Center

1898 Fort Road

Sheridan, WY 82801-8320

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

Sources Sought Notice – View Stations and Port Switches

DISCLAIMER

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

Response Instructions:

1. Do not provide more than 8 pages, including cover letter page.

2. Submit your response via email to charles.olise@va.gov

3. Submit your response NLT 13:00 (MST) on Monday, February 17, 2025;

4. Mark your response as “Proprietary Information” if the information is considered business sensitive.

5. VA has identified the appropriate North American Industry Classification System (NAICS) Code as 339112 – Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 Employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;

Information Requested from Industry:

1) In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses accordance with the Statement of Work draft / Salient Characteristics List.

Vendor Name:

SAM UEI #:

Name of Manufacturer:

Manufacturer Address:

Estimated Delivery Time:

SAC FSS contract number

Vendor Point of Contract (POC) Name

POC Phone Number:

POC Email Address:

View Stations and Port Switches For Sheridan VA Medical Center

STATEMENT OF WORK (SOW)

1. Background

The Sheridan Health Care System is requesting new Milestone view stations for Sheridan VAHCS maximize employee accountability, as well as patient safety and protection.

2. Scope

The Sheridan VA Medical Center (VAMC) intends to award a Fixed Priced contract for: (2) view stations, (3) 24-port switch. This equipment will be installed at Sheridan VAHCS and must be compatible and operate from Sheridan VAHCS Gallagher system. The Milestone camera system will be intergraded into the Gallagher Command Center in future upgrades.

The vendor will update all Milestone software to the most current available from the manufacture. If at any time during the life of this contract that new software is available, the vendor will update the Sheridan VAHCS Milestone software to the most current.

The vendor will supply a one-year maintenance and support option for the system equipment. During this time frame the vendor will update the system, provide programming support both on-site and by phone as needed, and replace defective hardware. Sheridan VAHCS requires a three-hour onsite timeframe due to expeditious speed in which this security system requires immediate attention.

Brand Name or Equivalent:

Line Item
Description
Unit
Quantity
0001
BCDSF01-ELWS-I5-T10 View Station
EA
02
0002
BCD-WA-1TB-35SHD
EA
02
0003
BCD-WA-MDP-HDMI
EA
04
0004
Axis T8524 PoE+ 24 Port Switch
EA
03
0005
SPO-8315 PoE+ Injectors
EA
03
0006
Installation
JB
01

3. Salient Characteristics

Vendor shall comply with all the following:

· Warranty: Software support and warranty information for all components, including Service Level Agreement details, and duration of agreement from date of system acceptance by owner (Sheridan VAHCS).

· Removal of current hardware.

· The vendor will execute the termination and disposal of unwanted hardware and/or wiring.

· The vendor will perform on-site training of the system.

· Supply all battery powered tools and/or hand tools, ladders, and subsequent equipment for installation.

· Supply all personnel protection equipment, steel toed boots, gloves, eye protection, appropriate weather clothing, safety equipment, and safety certifications.

· Be required to meet a three-hour response time to Sheridan VAHCS to make any necessary repairs and/or replacements to Gallagher/Milestone systems.

· Provide qualified, certified & experienced technicians for installation, service, and maintenance.

· Technicians shall hold current certifications with Gallagher Security and Milestone.

· Must adhere to all Sheridan VAHCS safety requirements and ensure continuous communication and deconfliction with Sheridan VAHCS Safety Officer.

· Safety and material selection submittals shall be complete prior to the commencement of onsite construction work.

· Provide live and full scope guidance, knowledge, training, and training aids to Sheridan VAHCS appointed personnel.

· Return all left-over (unused) product and materials to the Sheridan VAHCS.

· Installation shall include power, data and any other types of connections required to ensure operability of Milestone at Sheridan VAHCS.

· All wire connections shall be run in the method appropriate for the cable type (conduit, cable tray, etc.) per code.

· The vendor shall install expansion hardware and software as required to ensure future upgrades will be able to integrate Gallagher and Milestone software.

· Vendor shall ensure thorough testing that all new hardware and associated software function as intended.

· Vendor shall abide by all rules and regulations of Sheridan VAHCS. (Smoking, weapons, parking, etc.).

· Submit one (1) printed and one (1) electronic copy of project binder in final form. This copy shall contain as a minimum:

· Table of Contents for each element

· Vendor information - names phone numbers, and email for sales, technical support, and consumables reordering

· Lists of spare parts and replacement components recommended to be stored at the site for ready access

· Datasheets for all equipment

· Operation and maintenance manuals for all equipment

· Operation and maintenance procedures not covered in manufacture’s manuals

· All systems and components shall have been thoroughly tested and proven in actual use.

· The vendor shall work closely with the Sheridan VAHCS Contracting Officer Representative (COR), Facility Management Service, and Office of Information Technology Service on all work that will cause network and/or other system outages.

· The vendor shall follow outage notification timelines as outlined in the specifications.

· To the extent possible, the vendor shall tailor work schedules such that outages occur outside of normal VA work hours (0730-1600).

· Specified hardware/software (Sheridan VAHCS) includes:

· View Station Scope Overview:

· 2 - BCDSF01-ELWS-I5-T10 View Station

· 2 - BCD-WA-1TB-35SHD

· 4 - BCD-WA-MDP-HDMI

· Installation

· Switch Scope Overview:

· 3 - Axis T8524 PoE+ 24 Port Switch

· Installation

· PoE+ Injector Scope Overview:

· 3 – SPO-8315 PoE+ Injectors

· Installation

4. Security Requirements

The Contractor shall comply with the VA Personal Identity Verification procedures identified in the contract that implement Homeland Security Directive-12 (HSPD-12), Office of Management and Budget (OMB) Guidance M-05-24, and Federal Information Processing Standards Publication (FIPS PUB) Number 201.

5. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI)

None.

6. Other Pertinent Information or Special Considerations

Contractor shall follow the below guidelines for their work schedule except by prior arrangement approved by the COR or CO.

· The Federal Government observes the following days as holidays:

New Year’s Day
January 1st *
Martin Luther King’s Birthday
Third Monday in January
Presidents Day
Third Monday in February
Memorial Day
Last Monday in May
Juneteenth
June 19th *
Independence Day
July 4th *
Labor Day
First Monday in September
Columbus Day
Second Monday in October
Veterans’ Day
November 11th *
Thanksgiving Day
Fourth Thursday in November
Christmas Day
December 25th *

7. Place of Performance

VA Sheridan Health Care Sheridan VA Medical Center 1898 Fort Road Sheridan, WY 82801-8320

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .