6515--554 (C) Endoscope Channel Drying Cabinets RMR VAMC Federal contract opportunity
Solicitation number
36C25924Q0528
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19

About this file

This document is an amendment to a previous combined solicitation for Request for Quote (RFQ) #36C25924Q0528 for Endoscope Channel Drying Cabinets for the Department of Veterans Affairs Rocky Mountain Regional VA Medical Center.

The key details are:

  • This amendment provides answers to vendor questions, including that a 24-inch depth cabinet will be acceptable, and the government requires a total of 6 cabinets, not the 10 previously stated.
  • The solicitation is a 100% set-aside for service-disabled veteran-owned small businesses (SDVOSBs).
  • The government will award a firm-fixed price contract on an all-or-nothing basis, evaluating offers based on technical capability, completion of required certifications, and price.
  • Offers are due by 4:00pm MT on June 28, 2024 and must be emailed to the Contract Specialist. A site visit is scheduled for June 13, 2024.
  • The North American Industry Classification System (NAICS) code is 339113 with a small business size standard of 800 employees.

View the file

Other files for this federal contract opportunity

Other files attached to 6515--554 (C) Endoscope Channel Drying Cabinets RMR VAMC, newest first.
File Type Posted
SOW Scope Drying_Cabinets 5.31 Sol.docx DOCX document
52.225-2 Buy American Certificate.docx DOCX document
36C25924Q0528.docx DOCX document
852.219-76 VA Notice of Limitations on Subcontracting .docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment to a Previous Combined Solicitation

Amendment to a Previous Combined Solicitation

SUBJECT*
554 (C) Endoscope Channel Drying Cabinets RMR VAMC

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
80111
SOLICITATION NUMBER*
36C25924Q0528
RESPONSE DATE/TIME/ZONE
06-28-2024 16:00 MOUNTAIN TIME, DENVER, USA
ARCHIVE
5 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
6515
NAICS CODE*
339113
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office

NCO 19

6162 South Willow Drive, Suite 300 Greenwood Village CO 80111

POINT OF CONTACT*

Contract Specialist Natasha Holland natasha.holland@va.gov 303.712.5753 N/A

PLACE OF PERFORMANCE

ADDRESS
Department of Veteran Affairs

Eastern Colorado Healthcare System

Rocky Mountain Regional VA Medical Center

1700 N. Wheeling Street

Aurora CO

POSTAL CODE
80045
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

The purpose of this Amendment 0001 to RFQ 36C25924Q0528 is to answer vendor questions.

Q1. The space they have available at their facility is 92.5” high x 84” wide x 19.5” deep. Our cabinet sizes are:

Sideload EndoCab

Cabinet Size
Number Of Scopes
37” x 24” x 92”
6 Scope
43” x 24” x 92”
10 Scope
49” x 24” x 92”
16 Scope
57” x 24” x 92”
20 Scope

Would they accept a 24” depth sideload cabinet? We also have 20” depth topload cabinets, but they are 95” high?”

A1. The 24” will be acceptable. Height cannot exceed what is listed in the SOW.

Q2. Please let us know if the VA would be able to consider a proposal for cabinets with these alternative dimensions? Upon review, I cannot see a substantial difference between RFQ 36C25924Q0425 and RFQ 36C25924Q0528. As we will be submitting a proposal for this business, could you highlight the distinction such that can make sure to meet or exceed the government’s requirements?

A2. There is no longer a requirement for maintenance in filter changes, however the cabinets need to be able to provide the station the ability to complete the maintenance themselves. Additionally, Room Limitations were added. Cabinets must fit within these measurements due to space and fire system restrictions.

Q3. The document posted 6/4/24 named SOW+Scope+Drying_Cabinets+5.31+Sol states that the government has a requirement for 6 endoscope drying cabinets, yet document posted 6/4/24 named 36C25924Q0528 requests pricing on CLIN0001 and CLIN0002 for quantity 5 each. Should these CLIN’s reflect 3 each?

A3. The need is for a total of 6 cabinets. See below Q4. In the actual RFQ lines 1, 2, 9, and 10 are requesting 12. Could you post with clarifications?

A4. Lines 1 & 2 belong together to create 1 working cabinet totaling 5 cabinets. Lines 9 & 10 belong together to create 1 working cabinet totaling 1 cabinet.

*= Required Field
Amendment to a Previous Combined Solicitation

Page 1 of

Amendment to a Previous Combined Solicitation

File details come from the government source that posted it. Updated .