P03 Brand Name Justification - ED Ceiling Lifts - REDACTED.pdf
PDF 142 KB Posted
- Solicitation number
- 36C25923Q0809
About this file
This single source justification document outlines the Department of Veterans Affairs' requirement to procure 17 Arjo ceiling lifts with enhanced charging systems and infection control from Arjo and its authorized distributor Alliant Healthcare on an unrestricted basis. The medical center currently has 88 Arjo ceiling lifts installed across various patient care areas, and utilizes Arjo slings and other supplies that are only compatible with Arjo lifts. Conducting limited market research, the technical experts determined it would not be in the government's best interest to purchase another manufacturer's lifts due to the existing Arjo infrastructure and need for interoperability. The contracting officer certified this as a bona fide need of the agency. The related solicitation is for 6515--(660) ED-Patient Lifts for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25923Q0809 0001 Extend Offer Date.pdf | ||
| 36C25923Q0809_1 Ceiling Lifts SLCVAHCS.pdf | ||
| 36C25923Q0809.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHAPG Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT
Last Updated: 02/01/22 Page 1 of 3
DEPARTMENT OF VETERANS AFFAIRS
Justification for Brand Name Award IAW FAR 13.106-1 For
Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)
Acquisition Plan Action ID: 36C259-23-AP-3789 Tracking Number: 2023-08-28T06:52:15
1. Contracting Activity: Department of Veterans Affairs Network Contracting Office 19 (NCO19) 6162 South Willow Dr. Suite 300 Greenwood Village, Colorado 80111
Organizational Activity: Department of Veterans Affairs, Salt Lake City VA Medical Center, 500 Foothill Drive, Salt Lake City, UT 84148-0001.
2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount: The
George E Wahlen VA Medical Center requires the purchase Arjo ceiling lifts with an enhanced charging system (ECS) and infection control (IC). The Safe Patient Handling and Mobility (SPHM) employees will utilize the patient lift for routine patient handling tasks and assist veterans with mobility challenges.
Item # Part Number*/Description Qty
MS205-01-01 – Motors M S2 MB 2F ECS IC REG
0002 700-19465 – Hanger Bars and Accessories MS2 2pt IC Spreader Bar 17
0003 700-19485 - Scales MS2 17
0004 200.12810 – Track Assembly 3 Meter 90MM KWIKTRAK 34
0005 200.12870 – 4.5 Meter 140MM KWIKTRAK 17
0006 Hardware Kit 1
0007 Fee and Installation 1
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used: The medical center currently has a total of 88 Arjo manufactured ceiling lifts currently installed and in use in 88 patient care areas. Arjo Maxi Sky 600 ceiling lifts are
Last Updated: 02/01/22 Page 2 of 3 installed and in use in Acute Medicine (15), Rehab (5), Surgical (14), Telemetry (10), ICU (10), Same Day Surgery (2), Post Anesthesia Care Unit (4), Dialysis (2), Ambulatory Medicine Unit (2), Emergency Department (2), Respiratory ICU (8), out-patient physical therapy (1), and our Specialty Clinics (6) totaling 81. Arjo Maxi Sky 2 with ECS are installed and in use in CT (1), MRI (2), and Cardiology (4) totaling 7. Further, Arjo does not support other manufacturer’s ceiling lift brand cassettes to be placed on the existing Arjo ceiling lift tracks and rails within the patient areas. Lastly, the medical center has a variety of Arjo brand single patient use (SPU) Maxi Flite loop slings and Arjo brand re-usable loop slings in stock that cannot be utilized on another manufacturer’s patient lift. It would not be in the Government’s best interest to acquire another manufacturer’s patient lift with 88 patient areas utilizing the Arjo Maxi Sky ceiling lifts and the medical center maintaining a stock of Arjo manufactured supplies.
4. Description of market research conducted and results or statement why it was not conducted:
The technical experts conducted limited market research as it would not be in the best interest of the Government to purchase another manufacturer’s patient lifts based on the information stated in in paragraph 3 above. Further, as indicated in paragraph 3, Arjo does not support other manufacturer’s ceiling lift brand cassettes to be placed on the existing Arjo brand ceiling lift tracks and rails. Additional market research indicates the Arjo Maxi Sky 2 with ECS and IC can only be procured from Arjo, the large business manufacturer, and its only SDVOSB authorized distributor, Alliant Healthcare. With the product manufactured by a large business and only one (1) SDVOSB capable of meeting the Government’s needs, an SDVOSB set-aside is not permissible as the Nonmanufacturer Rule (NMR) cannot be met. As a result, this requirement will be solicited on an Unrestricted basis.
5. Requirements Certification: I certify that the requirement outlined in this justification is a Bona Fide Need of the Department of Veterans Affairs and that the supporting data under my cognizance, which are included in the justification, are accurate and complete to the best of my knowledge and belief.
Kristen Maynard Date Safe Patient Handling and Mobility Coordinator Salt Lake City VA Medical Center
08/29/2023 Kristen Maynard
Last Updated: 02/01/22 Page 3 of 3
6. Contracting Officer's Certification: I certify that the requirement outlined in this justification is a
Bona Fide Need of the Department of Veterans Affairs and that the supporting data under my cognizance, which are included in the justification, are accurate and complete to the best of my knowledge and belief.
Douglas D. Buffington Date
VA-VHA-RPOW-2023-0020
NCO 19, Supply Team 2
Douglas Buffington Digitally signed by
DOUGLAS BUFFINGTON
Date: 2023.08.31 12:49:00 -05'00'