This document contains an AutoCAD file detailing the mechanical room layout and equipment for a building, along with information for a federal contract opportunity to replace two air compressors.
The AutoCAD file provides details of the mechanical equipment in the building including two pumps, an alarm panel, various pipes and ducts of different sizes, air handling units, and mechanical room dimensions. The opportunity is to replace the two existing 125 HP air compressors with two new 100 HP air compressors at the Veterans Affairs Medical Center in Oklahoma City. The solicitation number provided is 36C25920R0120 for opportunity Z1DA-635-20-3-5406-1549. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19. The file includes relevant technical specifications and location information to support the air compressor upgrade work required under the contract.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25920R0120 0003.pdf | ||
| VA.xlsx | XLSX spreadsheet | |
| 07 - 3rd Floor-Mech Room.pdf | ||
| 36C25920R0120 0002.pdf | ||
| 36C25920R0120 Replace Air Compressors RFIs answered.docx | DOCX document | |
| 36C25920R0120 final.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
3,709 SF
AutoCAD SHX Text
PUMP #1
AutoCAD SHX Text
PUMP #2
AutoCAD SHX Text
PUMP #2 SUPPLIES 1. AHU-2 2. PENTHOUSE
AutoCAD SHX Text PUMP #1 SUPPLIES 1. AHU-1 2. 9th FLR. 3. 5th FLR. 4. GRD. FLR.
AutoCAD SHX Text
UP TO ROOF
AutoCAD SHX Text
UP TO ROOF
AutoCAD SHX Text 18"X 18"
AutoCAD SHX Text 24"
AutoCAD SHX Text
ALARM PANEL DENTAL
AutoCAD SHX Text 4" S.V.
AutoCAD SHX Text 2"
AutoCAD SHX Text Shows going up but there is nothing on 4th floor. May be an unused lines.
AutoCAD SHX Text Unknown destination. Believed to be cut off inside wall.
AutoCAD SHX Text
MECHANICAL EQUIPMENT ROOM
AutoCAD SHX Text 3" S.S.
AutoCAD SHX Text 4" S.V.
AutoCAD SHX Text 2" S.V.
AutoCAD SHX Text 4" D.S.
AutoCAD SHX Text 4" S.D.
AutoCAD SHX Text 4" R.D.
AutoCAD SHX Text 5" D.S.
AutoCAD SHX Text
1 " CW12" CW
AutoCAD SHX Text
1 " CW14" CW
AutoCAD SHX Text
1" HW
AutoCAD SHX Text
1 " HW14" HW
AutoCAD SHX Text
AC-1
AutoCAD SHX Text
AC-2
AutoCAD SHX Text
TO STEAM CONDENSATE PUMP
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text
PANEL - P2
AutoCAD SHX Text
BREAKERS
AutoCAD SHX Text
FE
AutoCAD SHX Text
FE
AutoCAD SHX Text
MCC & CONTROLS
AutoCAD SHX Text
HGT: 10'-10"
AutoCAD SHX Text
41K CFM
AutoCAD SHX Text
AIR PAD 1
AutoCAD SHX Text 34"%%c
AutoCAD SHX Text 34"%%c
AutoCAD SHX Text 28"%%c
AutoCAD SHX Text 24"%%c
AutoCAD SHX Text 24"%%c
AutoCAD SHX Text 14"%%c
AutoCAD SHX Text 24"%%c
AutoCAD SHX Text 24"%%c
AutoCAD SHX Text 24"%%c
AutoCAD SHX Text
54X38 OA DUCT
AutoCAD SHX Text 27"X 27"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 10"
AutoCAD SHX Text 10"
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text 2"
AutoCAD SHX Text 34"
AutoCAD SHX Text