This is a Sources Sought Notice issued by the Department of Veterans Affairs (VA) Network Contracting Office for market research purposes. The VA North Texas Health Care System's Pathology and Laboratory Medicine Services is seeking to identify vendors capable of providing blood bank reagents, consumables, and a fully automated gel instrument configured to work with government-owned Ortho Workstations in the Transfusion Medicine Unit, Room 1B-306, located in Dallas, Texas. The anticipated contract type is cost per test with analyzer included, falling under NAICS code 541380 (Testing Laboratories and Services) and Product Service Code 6640 (Laboratory Equipment and Supplies). Interested vendors must submit electronic capability statements including place of manufacture information by July 27, 2026, at 9:00 AM Central Time via email to Teresa Arzola at teresa.arzola@va.gov.
The requirement encompasses annual testing volumes and reagent needs including 7,800 ABO/RH tests, 4,000 antibody screens, 60 antibody identifications, 200 direct antiglobulin tests, 100 immediate spin crossmatches, and 400 AHG crossmatches, along with corresponding consumables and traditional reagents on standing order with scheduled delivery. The automated analyzer must include critical system requirements such as continuous random and STAT access capability, minimal daily maintenance, sample carryover prevention, automatic cap and clot detection, up to 24-hour walkaway time, 5-megapixel optical resolution for gel card imaging, and bidirectional interface with VistA via Data Innovations software. Delivery of the analyzer and initial reagents must occur within 60 days of contract award to 4500 S. Lancaster Road, Dallas, Texas 75216. This Sources Sought Notice is issued solely for planning and market research purposes and does not constitute a binding solicitation; responses are voluntary and will not obligate the Government to issue a formal solicitation or award a contract.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| Blood Bank Cost Per Test |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 78240 |
| SOLICITATION NUMBER* |
| 36C25726Q0775 |
| RESPONSE DATE/TIME/ZONE |
| 07-27-2026 9:00 AM CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6640 |
| NAICS CODE* |
| 541380 |
| CONTRACTING OFFICE ADDRESS |
| Department Of Veterans Affairs |
Network Contracting Office 17
5441 Babcock Road Ste. 302 San Antonio TX 78240
POINT OF CONTACT*
Contract Specialist Teresa Arzola teresa.arzola@va.gov 5441 Babcock Rd. Ste. 302
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
Dallas VA North Texas Health Care System
ATTN: Pathology & Laboratory Service
4500 S. Lancaster Rd.
Dallas TX
| POSTAL CODE |
| 75216 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov |
| URL DESCRIPTION |
| U.S Department of Veterans Affairs |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Teresa.Arzola@va.gov |
| EMAIL DESCRIPTION |
| VA EMAIL |
DESCRIPTION
THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for quote (RFQ), request for proposal (RFP), or invitation for bid (IFB). No solicitation is currently available. This Sources Sought is issued solely for information and planning purposes to conduct market research and determine the availability and capability of qualified sources prior to determining the appropriate acquisition strategy.
I. General Information
- Agency/Office: Department of Veterans Affairs (VA), VA North Texas Health Care System (VANTHCS), Dallas, TX.
- Place of Performance: VA North Texas Health Care System, Pathology and Laboratory Medicine Service (P&LMS), Microbiology Laboratory, Dallas, Texas.
- Anticipated NAICS: 541380 – Testing Laboratories and Services
- Anticipated PSC: 6640 – Laboratory Equipment and Supplies.
The Government is seeking to identify responsible vendors capable of providing Blood Bank Cost Per Test Reagents, brand name or equal, configured and supported with Government owned Ortho Workstations in the Transfusion Medicine Unit Room 1B-306, Pathology and Laboratory Medicine Services at VANTHCS.
II. Description of Requirement Transfusion Medicine Unit, Pathology and Laboratory Medicine Services (P&LMS) at the VA North Texas Health Care System (VANTHCS), Dallas, TX is seeking a fully automated gel instrument and reagents to perform Type & Screen testing with antibody ID panels, Direct Antiglobulin test, IS and AHG crossmatches and the capability to test for antigens.
Contract type will be cost per test with analyzer included.
The contemplated purchase includes, at a minimum:
The Contractor shall provide reagents, consumables, and supplies as requested by VANTHCS staff to perform blood bank testing for the analyzer.
Estimated quantities shown below are for annual requirements.
Group I – Estimated Yearly Test Volume:
| Assay |
| Est. Annual Test Volume |
| ABO/RH |
| 7,800 |
| Antibody Screen |
| 4,000 |
Antibody Identification (with Selected Cell Panels capabilities)
| Direct Antiglobulin Test-IgG, C3d |
| 200 |
| Immediate Spin Crossmatch |
| 100 |
| AHG Crossmatch |
| 400 |
| ABD Group Forward type |
| 500 |
| O Group Forward type |
| 500 |
Group II – Estimated Yearly Reagents & Consumables Requirements:
| Reagents & Consumables |
| Est. Annual Volume |
| A/B Group |
| 500 |
| A/B/D Group |
| 500 |
| A/B/D Mono & Reverse Group |
| 7,800 |
| DAT Card (IgG & C3d) |
| 200 |
| Anti-IgG Card |
| 4,000 |
| Buffered Gel Card |
| 200 |
| 7% Bovine Serum Albumin |
| 32 |
| Evaporation Caps for Reagent Red Cells |
| 2 |
| Diluent 2 |
| 4 |
| Diluent 2 Plus |
| 7 |
Group II – Estimated Yearly Traditional Reagents Requirements:
| Traditional Reagents – Standing Order with Scheduled Delivery Schedule. |
| Est. Annual Volume |
| 0.8% A1 Cell and B Cell (0.8% Affirmagen) |
| 78 |
| 0.8% Panel B |
| 13 |
| 0.8% Panel C |
| 13 |
| 0.8% Antibody Screen Cells 3 Cells (0.8% Surgiscreen) |
| 78 |
| Daily QC Kit |
| 52 |
Location: The analyzer shall be located, and testing will be performed in Transfusion Medicine Unit, Room 1B-306, Pathology & Laboratory Medicine Service, VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.
Delivery: Within 60 days of the contract award the vendor will deliver the analyzer and reagents to VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.
III. Performance requirements:
Performance Requirements: The following are required:
A. Installation Requirements:
1) Deliver, install, and set up the instrument (automated analyzer) and components.
2) Deliver one manual testing platform (equipment)
3) Provide test validation guidance and validation supplies.
B. Testing Requirements:
1) ABO/RH
2) Antibody Screen (3 Cells)
3) Direct Antiglobulin Test (DAT)
4) Antibody Identification (with Selected Cell Panels Capabilities)
5) Immediate Spin Crossmatch
6) AHG Crossmatch
7) Antigen Testing Capabilities
8) Antibody Titration (with automated serial dilutions) Capabilities
C. System Requirements:
1) The system must contain continuous, random and STAT access technology.
2) The system must have minimal daily maintenance and tracking capabilities when maintenance has been completed.
3) The system should have technology to prevent sample carryover.
4) The system must feature error-proof reagent and commodity design with built-in safeguards to prevent reagent mix-ups, probe crashes and unnecessary downtime.
5) Sample carriers must be capable of utilizing different tube sizes in one carrier, thus avoiding the need for pre-analytic sorting.
6) The system must have automatic cap, clot and liquid level detection capabilities.
7) The system must not utilize proprietary system liquids.
8) The system must offer up to 24 hours of walkaway time.
9) When operational, the system must always be in a ready mode and at no time go into a hibernation or “sleep” state.
10) The system must be able to run selected cell antibody identification panels.
11) The optical resolution of the onboard camera must be at least 5-megapixel resolution down to 32 x 32 microns and store a digital image of both the front and back of each gel card to record test results.
12) A fully loaded waste container shall not weigh more than 11 lbs. and be accessible at waist height.
D. Connectivity Requirements: (Note: Does not use the following software: Windows XP Embedded Service Pack 3, Windows Server 2003 or Windows XP.)
1) System is fully interfaced (bidirectional) with VistA via Data Innovations: System accommodates reporting through Data Innovations (DI) to eliminate the need for manual data entry.
IV. Submission Instructions Interested and capable vendors should submit an electronic capability statement and include the place of manufacture for all equipment and reagents via email in PDF or Word format by July 27, 2026, by 9:00 AM Central Standard Time.
- Teresa Arzola
- Email: Teresa.arzola@va.gov
- Subject line: “Sources Sought – Blood Bank Cost Per Test Reagents – VA North Texas HCS”