This document is an Interior Signage Design Standards and Construction Documents guide for the Dallas VAMC Wayfinding & Signage project prepared by Wayfinding Associates for the VA North Texas Health Care System, dated October 23, 2019.
The document establishes comprehensive design and installation standards for interior signage across the Dallas VA Medical Center. It specifies four Helvetica typeface options (Regular, Bold, Bold 77 Condensed, and Regular 57 Condensed) as ADA/ABA compliant fonts, with guidance that typefaces must be commercially purchased by vendors rather than provided by the design consultant. The standards define over 40 symbol codes (parking, elevators by floor letter, restrooms, wayfinding arrows, hazard warnings, medical symbols, etc.) to be used in sign message schedules. Mount hardware specifications include 18 categories (A through R, plus variations) covering pressure-sensitive tape, magnetic, hook-and-loop, screw, pin, hooks, freestanding brackets, ceiling attachments, cable systems, blade signs, glass applications, and panel-mounted options. Eight location categories define positioning requirements, including ADA-compliant tactile sign placement specifications requiring 48-60 inches above finished floor for tactile character baselines, 18-inch x 18-inch clear floor spaces around tactile signs, and specific latch-side door positioning.
The standards document includes detailed installation height requirements with preferred overhead clearance at 84 inches and minimum at 80 inches, maximum tactile text baseline at 60 inches, minimum at 48 inches, and visual character baseline minimum at 40 inches. Sign type series (D1, D2, i-series, L-series, N-series, R-series, W-series, and others) are defined with color-coded header graphics varying by suffix letters (b, c, p, s, t, y) representing different building locations and departments. The guide covers directory signs, room identification plaques, threshold identifiers, elevator information signs, emergency exit signage, restroom identifiers, wayfinding directionals, warning and caution notices, restrictive access signage, vinyl graphics, custom displays, and dimensional letter applications. Special considerations address mental health inpatient spaces, restricted areas, medical gas zones, and accessibility features including SmartStrip status indicators and paper insert holders for dynamic messaging.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 549-20-132 Floor Plan Combined.pdf | ||
| S02 36C25726Q0427 0001.pdf | ||
| S02 36C25726Q0427.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DALLAS VAMC WAYFINDING & SIGNAGE
VA North Texas Health Care System
Interior Signage Design Standards and Construction Documents
23 October 2019
Wayfinding Consultant:
Signage General Contractor:
Client:
Project:
Architect / Engineer:
AP01
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
Symbols & ArrowsFonts
[va logo] [va logo 2]
[va logo seal]
Helvetica Regular - 2010 ADA/ABA compliant tactile and visual text components
Helvetica Bold - Emphasis text font (ADA/ABA visual compliant only)
Helvetica Bold 77 Condensed - Overhead Sign Font (ADA/ABA visual compliant only)
Helvetica Regular 57 Condensed - Gateway sign usage
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890
Typeface Copyright Information Typefaces are licensed by their creators and as such cannot be provided to project participants or the fabricator by Wayfinding Associates. Typefaces are commercially available for purchase and download from online font resellers like Fonts.com, MyFonts.com and others.
[va ntx logo]
[shower]
[star]
[fire stair][stair]
[elevator]
[bio][rad]
[caution]
[oxygen] [register] [no weapons]
[pregnant][isa]
[AED]
AED
[no entry]
[up]
[down]
[left]
[right]
[up left]
[up right]
[down left]
[down right]
[unisex]
[unisex isa]
[women]
[women isa]
[men]
[men isa][family] [family isa]
Symbol Codes Each symbol is assigned a code inside of brackets [ ], for example [parking] represents the parking symbol.
These codes are included in the sign message schedule where the corresponding symbol is to be included on a sign.
Selected sign vendor will be provided electronic artwork of symbols upon request.
Symbols with ‘x’ suffix vary in color, see corresponding sign type drawing for color specification.
Hairline outlines on outer boundary of symbols are to define shape only and are not to be included when produced on signs.
[bc]
Client:
Project:
Architect / Engineer:
AP02
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
Symbols & Arrows
Symbol Codes Each symbol is assigned a code inside of brackets [ ], for example [parking] represents the parking symbol.
These codes are included in the sign message schedule where the corresponding symbol is to be included on a sign.
Selected sign vendor will be provided electronic artwork of symbols upon request.
Symbols with ‘x’ suffix vary in color, see corresponding sign type drawing for color specification.
Hairline outlines on outer boundary of symbols are to define shape only and are not to be included when produced on signs.
[A elevator]
[A,B elevators]
[B elevator] [C elevator] [D elevator]
[C,D,E elevators]
[E elevator] [F elevator] [G elevator][unisex x]
[unisex isa x]
[cross][stop]
[voltage] [no elevator][quiet][danger]
[parking F][do not enter] [parking P] [parking L]
[women x]
[women isa x]
[family x]
[family isa x]
[men x]
[men isa x]
[magnet] [pharmacy][no smoking]
Rx
A
A
B
B
C
C
D
D
E
E
F G
P P P
[extinguisher]
Client:
Project:
Architect / Engineer:
AP03
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
Mounts and Locations
Mount hardware for each sign is specified in the message schedule“HARDWARE” column
Mount location for each sign is specified in the message schedule“LOCATION” column
S Round Surface - For mounting to round/curved surface.
Vertical brackets on each side of sign attach to curved surface.
Specify diameter of mounting surface.
T Strap Bracket - For mounting to existing poles.
Sign panel mechanically fastened to steel bracket, bracket is secured to existing pole with adjustable metal straps.
X Post(s) in Ground - Post(s) in ground mount. Posts and concrete to extend to local frost-line. Fabricator to detail mounting in shop drawings.
A Pressure Sensitive Tape - For smooth, hard surfaces.
Not recommended for some vinyl wall coverings.
Supplement with clear silicone on wall-covering or irregular surfaces. Sign not to exceed 100 square inches.
B Magnetic - For steel surfaces. Sign not to exceed 100 square inches.
C Hook and Loop - For fabric surfaces. Sign not to exceed 100 square inches.
D Screw - For rough surfaces such as brick or drywall.
Recommended for wall-mounted signs exceeding 100 square inches.
E Pin - For fabric surfaces, including fabric on hard material and acoustic panels. Sign not to exceed 100 square inches.
F Hook - For workstation panels. Clear bracket hooks over panel top; sign is suspended 2” down. Specify panel manufacturer, model and thickness.
G Freestanding Perpendicular - For freestanding applications such as desks. Extruded aluminum bracket. Standard 2-sided sign sits perpendicular to work surface; maximum recommended sign height is 4”.
GL Freestanding Angle - For freestanding applications such as desks. One-sided sign is mounted to “L” bracket at a 60° angle.
H Panel Top - For top surface of furniture panel. Bracket is extruded aluminum affixed to panel top with pressure-sensitive tape. 8” maximum sign height.
i1.0 Suspended Ceiling - For attaching to 1” ceiling grid.
Connects with 2” extruded aluminum brackets. Sign should not exceed 1,440 square inches and 150 lbs.
i0.5 Suspended Ceiling - For attaching to 1/2” ceiling grid.
Connects with 2” extruded aluminum brackets. Sign should not exceed 1,440 square inches and 150 lbs.
J Cable Attachment - Braided stainless steel cable for high or irregular ceilings. Attach cables to/around rafters, beams, duct work, piping, etc. Sign should not exceed 1,440 square inches and 150 lbs. Installer to determine and provide appropriate cable and fasteners.
K Perpendicular “Blade” - For mounting 2-sided overhead “blade” signs to wall. Sign is mounted perpendicular to wall.
Not available for signs wider than 15”.
L Glass - For backside of glass windows, doors or walls.
Clear acrylic bracket affixes to glass with clear pressure-sensitive tape.
M Ceiling Bracket - For general-purpose ceiling mount applications. Extruded aluminum bracket affixes to ceiling with screws. Sign should not exceed 1,440 square inches and 150 lbs. Installer to determine and provide appropriate fasteners and anchors.
N Rigid Posts to Ceiling - For general-purpose ceiling mount applications. Black 0.5” diameter aluminum rod suspends sign 6”, 12”, 18”, 24” from ceiling. Sign should not exceed 1,440 square inches and 150 lbs. Installer to determine and provide appropriate fasteners and anchors.
1”
½”
O Flexible Under-the-Top-Cap - For workstation wall panels.
Flexible black fabric device is held in place by panel top cap.
Sign locates flush with panel top.
P Panel/Tile - For workstation panels and tiles.
Aluminum hook device hooks over the top of panel or tile and is concealed by panel top cap. Locates top of sign flush with top of panel. Specify panel manufacturer, model and thickness.
R Saddle - For clear or frosted panels. Aluminum device hooks over panel top. Locates top of sign flush with panel top. Can be 1 or 2-sided. Maximum sign size is 4” high by 11” wide. Specify panel thickness.
Location 1 Identifier signs with tactile text
HORIZONTAL POSITION:
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side, 4.5” from edge of door.
Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf, 4.5” from edge of active door.
Where a tactile sign is provided at double doors with two active leafs, the sign shall be located on wall to the right of the right hand door, 4.5” from edge of door.
Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall, 3” from corner (adjust as needed).
Signs containing tactile characters shall be located so that a clear floor space of 18 inches minimum by 18 inches minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.
Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices.
Location 2 Wall signs with no tactile text Mount as positioned on location plan, centered on surface where sensible or as noted in message schedule.
Location 3 Adjacent to corner Mount 3” from inside or outside corner as shown on sign location plan. Adjust for obstacles as needed.
Location 4 Overhead wall mounted sign position Mount as positioned on location plan, centered on surface where sensible.
Preferred height 84” above finished floor to bottom of sign (80” min.) adjust as needed.
Location 5 Side of hallway overhead sign position Mount to ceiling 2” from wall.
Preferred height 84” above finished floor to bottom of sign, minimum 80” clearance required, adjust as needed.
Location 6 Center of hallway overhead sign position Mount to ceiling centered on width of hallway at location specified on sign location plan.
Preferred height 84” above finished floor to bottom of sign, minimum 80” clearance required, adjust as needed.
Location 7 Non-standard sign position Mount as described in notes column.
Location 8 Client-requested mount location Mount centered on door frame above door
Client:
Project:
Architect / Engineer:
AP04
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
Signs with tactile characters shall comply with 703.4.
703.4.1 Installation Height and Location.
Signs with tactile characters shall comply with 703.4. 703.4.1 Height Above Finish Floor or Ground.
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character.
TEXTgety
TACTILE
TACTILE 48” AFF to lowest allowed tactile text baseline
60” AFF to highest allowed tactile text baseline
703.4.2 Location.
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side.
Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf.
Where a tactile sign is provided at double doors with two active leafs, the sign shall be located to the right of the right hand door.
Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall.
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.
EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices.
5’-0” AFF to tactile character baseline max. height
Tactile character range
4’-0” AFF to tactile character baseline minimum height
Enlarged View of SIgn
TEXTgety
TACTILE
TACTILE
TEXTgety TEXTgety TEXTgety
CL
CL
CL
CL CL
EXCEPTION
Tactile sign permitted on push side of doors with closing hardware but without hold-open devices
Minimum Clearance Area Sign containing tactile characters shall be located so that a minimum clear floor space of 18”x18” centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.
NOTICE
Do not place tactile sign on outward swinging door
45° 45°
INACTIVE ACTIVE
* 9”min. 9”min. 9”min.*
Scale: 3/8”=1’
XTACTILE
TACTILE
TACTILE
TACTILE
TACTILE
TACTILE
Min. 18”x18” Square Area
Min. 18”x18” Square Area
ADA Compliant Tactile Sign Positioning
Client:
Project:
Architect / Engineer:
AP05
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
D1.x
.p suffix
.s suffix
.y suffix
.b suffix
.t suffix
.c suffix
D1 series sign types header graphics vary by suffix letter as follows:
DIRECTORY
DESTINATIONS A-M
Agent Cashier Ambulatory Surgery Center Anticoagulation Audiology
Behavioral Health (Outpatient) Billing/Customer Service Blood Bank Blood Draw
Cafeteria Chapel Clinic Check-in & Check-out Conference Rooms
Decedent Affairs Dialysis DiaTel Study Guest Lounge
Echo Lab Check-in Edema / Wound Clinic
EEG
Eligibility Emergency Department
EMG
ENT
Executive Suite Eye Clinic
DESTINATIONS A-M
Agent Cashier Ambulatory Surgery Center Anticoagulation Audiology
Behavioral Health (Outpatient) Billing/Customer Service Blood Bank Blood Draw
Cafeteria Chapel Clinic Check-in & Check-out Conference Rooms
Decedent Affairs Dialysis DiaTel Study Guest Lounge
Echo Lab Check-in Edema / Wound Clinic
EEG
Eligibility Emergency Department
EMG
ENT
Executive Suite Eye Clinic
C C
C C
B B
B B
D D
C C
Green Blue Blue Brown
Brown Blue Blue Blue
Green Green Blue Blue
Red Green Purple
Green Blue Green Red Red Green Green Green Blue
Green Blue Blue Brown
Brown Blue Blue Blue
Green Green Blue Blue
Red Green Purple
Green Blue Green Red Red Green Green Green Blue
B
B B
B
B B
B
B B
B
B B
A A
B B
B B
C C
E E
F F
B B
B B
G G
G G
Bldg | Floor | Use Elevator Bldg | Floor | Use Elevator
You Are Here Registration (New Guests)
Registration Kiosks (Returning Guests)
Information Desk
Restroom(s) StairsGuest Elevators
You Are Here Building 60, Floor 1
Main Entrance
Community Living Center
Spinal Cord Injury (SCI)
South Entrance
North Entrance
Radiation Oncology
Emergency Entrance
Emergency Dept
Clinics
Hospital
Behavioral Health
F
E
C
B
A
G
D
Polytrauma
EXAMPLE ONLY
1 74
2J
ED
A
Client:
Project:
Architect / Engineer:
AP06
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
D2.x
.p suffix
.t suffix
.s suffix
.b suffix
.y suffix
.c suffix
D1 series sign types header graphics vary by suffix letter as follows:
DIRECTORY
DESTINATIONS A-M
Agent Cashier Ambulatory Surgery Center Anticoagulation Audiology
Behavioral Health (Outpatient) Billing/Customer Service Blood Bank Blood Draw
Cafeteria Chapel Clinic Check-in & Check-out Conference Rooms
Decedent Affairs Dialysis DiaTel Study Guest Lounge
Echo Lab Check-in Edema / Wound Clinic
EEG
Eligibility Emergency Department
EMG
ENT
Executive Suite Eye Clinic
DESTINATIONS A-M
Agent Cashier Ambulatory Surgery Center Anticoagulation Audiology
Behavioral Health (Outpatient) Billing/Customer Service Blood Bank Blood Draw
Cafeteria Chapel Clinic Check-in & Check-out Conference Rooms
Decedent Affairs Dialysis DiaTel Study Guest Lounge
Echo Lab Check-in Edema / Wound Clinic
EEG
Eligibility Emergency Department
EMG
ENT
Executive Suite Eye Clinic
C C
C C
B B
B B
D D
C C
Green Blue Blue Brown
Brown Blue Blue Blue
Green Green Blue Blue
Red Green Purple
Green Blue Green Red Red Green Green Green Blue
Green Blue Blue Brown
Brown Blue Blue Blue
Green Green Blue Blue
Red Green Purple
Green Blue Green Red Red Green Green Green Blue
B
B B
B
B B
B
B B
B
B B
A A
B B
B B
C C
E E
F F
B B
B B
G G
G G
Bldg | Floor | Use Elevator Bldg | Floor | Use Elevator
EXAMPLE ONLY
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
2C-901A3 2C-901A32C-901A3
1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3
2a901a3 2a901a32a901a3
Mechanical Room
Mechanical Room i2.x i2e.x i2m.xi1.x
.p suffix .s suffix .t suffix .y suffix.b suffix .c suffix i series sign types tactile insert / plaque colors varies by suffix letter as follows:
Alcove and captive room ID
Support room ID
Exterior grade
Mental Health i7.2fi7.2ci7.1
2-sided ‘flag’2-sided ceiling mount1-sided wall mount i1m.x Mental Health room number only
Family Restrooms
Family Restrooms
Family Restrooms
.p suffix .s suffix .t suffix .y suffix.b suffix .c suffix i7 series sign types symbol colors varies by suffix letter as follows:
Wayfinding Consultant:
Signage General Contractor:
Client:
Project:
Architect / Engineer:
AP07
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
Patient Lounge & Group Room
2a901a3
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Wayfinding Consultant:
Signage General Contractor:
Client:
Project:
Architect / Engineer:
AP08
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
Signage Installation Height
A-144 2a901a3
Exam
In Use i4.x i4m.xi3m.b i5m.b
A
Exam/Treatment ID w/status slider & SmartStrip
Exam/Treatment ID for inpatient Metal Health spaces
Office ID
Metal Health
Occupied Room ID
Public Corridor Restroom ID
Metal Health spaces
Vinyl Backer
XXX
Occupied Room ID
2C-901A3 2a901a3
Staff Work Room i3v i4v i5v i19.1 i19.2 i5.x
1A-168 2a901a3 women
FAMILY
RESTROOM
i6.x i6m.x i7.2fi7.2ci7.1
2-sided ‘flag’2-sided ceiling mount1-sided wall mount
Family Restrooms
Family Restrooms
Family Restrooms
.p suffix .s suffix .t suffix .y suffix.b suffix .c suffix i7 series sign types symbol colors varies by suffix letter as follows:
2a901a3 mens restroom
MEN’S
RESTROOM
1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3 w/SmartStrip
2C-901A3 2a901a3
Office i3.x
1-139 2a901a3
Exam
A
Changing Station
Is Available In Room # Dept Name
Office
2a901a3
Patient Lounge & Group Room
Client:
Project:
Architect / Engineer:
AP09
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
2C-901
2a901a3
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
NPO
NPO NPO NPO
NPO
See Nurse to Enter
See Nurse to Enter
6C-1091C-140 6C-1111C-148 11 122 26e2526e252 6e2526e2526e252 6e252
NPO
See Nurse to Enter i9.1bi8.1y i10.1si9.2bi8.2y i10.2si9m.1b i9m.2b Building 2 private patient
Med-Surg & ICU private patient Room ID
CLC private patient Room ID
Building 1
Building 2 semi-private patient room ID
Med-Surg & ICU semi-private patient Room ID
CLC semi-private
Building 1 semi-private
2C-901 2a901a3
1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3
.p suffix .s suffix .t suffix .y suffix.b suffix .c suffix i series sign types tactile insert / plaque colors varies by suffix letter as follows:
i16.1 i16.2c i16.2f
1-sided wall mount 2-sided ceiling mount 2-sided ‘flag’
Restrooms Restrooms Restrooms i16 series sign types symbol colors varies by suffix letter as follows:
Client:
Project:
Architect / Engineer:
AP10
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3
.p suffix .s suffix .t suffix .y suffix.b suffix .c suffix
In Use
Gathering Room ID w/SmartStrip
Destination ID
2C-901A3 2C-901A3 2a901a3 2a901a3
Conference Room
Physical & Occupational Therapy i12.x i13.x
1A-168 2a901a3 women
FAMILY
RESTROOM
i14.x
NPO NPO NPO
1 26e252 6e252 i11.1p i11.2p SCI private
SCI semi-private i13v i12m.b Gathering Room ID w/ Paper Insert for inpatient
Metal Health spaces i14m.b
2a901a3 mens restroom
STAFF
RESTROOM
i2m.x
Conference Room
Client:
Project:
Architect / Engineer:
AP11
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3 1C-901A3
.p suffix .s suffix .t suffix .y suffix.b suffix .c suffix i series sign types tactile insert / plaque colors varies by suffix letter as follows:
1C-140 6e252 1C-148
1 26e252 i18.1c i18.2c Building 2J patient Room ID Building 2J semi-private w/status slider
Alcove and captive
2C-901A3 2a901a3
Office i15.x i17.x
In Use
C105B i40.c
Room ID replacement plaque
1A-168
Client:
Project:
Architect / Engineer:
AP12
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Welcome to Welcome to
Hospital Clinics
Building 2 Building 2J i20.1 i20.2 i20.2J
40"
Wall-Mounted Threshold Identifier
Welcome to
Mental Health
Building 1
Client:
Project:
Architect / Engineer:
AP13
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Welcome to Welcome to
Spinal Cord Injury Center
Emergency Department
Building 74 Emergency i20.60 i20.74 i20.ED
40"
Wall-Mounted Threshold Identifier
Welcome Building 60
Community Living Center
Client:
Project:
Architect / Engineer:
AP14
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Building 1Mental Health
Hospital
Clinics
Community Living Center
Spinal Cord Injury Center
Building 2
Building 2J
Building 60
Building 74
Emergency i21.1 i21.2
1-sided 2-sided
Overhead Building Threshold Identifier
Client:
Project:
Architect / Engineer:
AP15
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
To Bldg 2J Floors B, 3 & 5
ElevatorsB
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
To Bldg 2J Floor 3 Only Use ‘B’ Elevators to access Building 2J Floors B and 5
ElevatorA
To Bldg 2J Floors B, 3 & 5
ElevatorsB
Serves Bldg 2 Floors B, 1-9
ElevatorsC
Serves Bldg 2 Floor B,1 ElevatorsD
Serves Bldg 2 Floors B, 1-4 ElevatorsE
To Bldg 74 Floor B
ElevatorF
Elevators
Elevators
G
G i30.a i30.b i30.c i30.d i30.e i30.f i30.g i30.g
To Bldg 1 Floors 2-5
To Bldg 1 Floor 6 - Restricted
Use far right elevator to access Floor 6 (restricted access)
Use center and left elevators to access Floors 2-5
Use ‘C’ Elevators to access all other Building 2J Floors
Use ‘C’ Elevators to access all other Building 2J Floors
Client:
Project:
Architect / Engineer:
AP16
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance 84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Physical/Occupational Therapy
Emergency Department i33.1xi32.1x i33.2xi32.2x
Serves Building 2 Floors B, 1-9 ElevatorsE i31.1x i31.2x 1-sided 1-sided 1-sided2-sided 2-sided 2-sided
.p suffix .s suffix .t suffix .y suffix.b suffix .c suffix i31, i32 and i33 series sign types graphics panel varies by suffix letter as follows:
Silver Clinic i34.1x i34.2x 1-sided 2-sided
Client:
Project:
Architect / Engineer:
AP17
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance 84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
REGISTRATION REGISTRATION
i35.4 i36.4 i44.2x i46.2x i47
ElevatorsE
2-sided 2-sided
2-sided
.p suffix .s suffix .t suffix .y suffix.b suffix .c suffix i31, i32, i33, and i44 series sign types graphics panel varies by suffix letter as follows:
Cashier Line
Client:
Project:
Architect / Engineer:
AP18
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
REGISTRATION REGISTRATION
i35.4 i36.4
Client:
Project:
Architect / Engineer:
AP19
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
REGISTRATION REGISTRATION
i35.8 i36.8
Client:
Project:
Architect / Engineer:
AP20
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
REGISTRATION
i35.10
Client:
Project:
Architect / Engineer:
AP21
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Egress stair identifier
Egress stair identifier Exterior Grade
Egress stair ID
Inpatient Mental Health spaces
.0
0”
L2.x L2e.x L2m.x
EXIT
STAIR 11
EXIT
STAIR 11
stair c fire exit stair c fire exit
Keep Door Closed Keep Door Closed
L1 L1m Evacuation map holder w/ elevator notice Evacuation map holder w/ elevator notice Inpatient Mental Health spaces
Fire & Emergency Exit Plan In emergency do not use elevators.
Use marked exits.
Map Artwork
TBD
Fire & Emergency Exit Plan In emergency do not use elevators.
Use marked exits.
Map Artwork
TBD
EXIT
STAIR 11
stair c floor 1
Keep Door Closed
Client:
Project:
Architect / Engineer:
AP22
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
No Re-Entry Message No Re-Entry Stair Message
Re-Entry Message Re-Entry Message Inpatient Mental Health spaces
L5 L6L4 L4m Fire Door Message
Exterior Grade
Health spaces
L3 L3e L3m
Fire Door
Fire Door
Keep closed at all times
Keep closed at all times
NO NO
Re-entry Re-entry
Re-entry
.0
0”
Re-entryFire Door Keep closed at all times
Re-entry
NO RE-ENTRY
ON THIS FLOOR
Re-enter down to floor 1
Re-enter up to floor 4
L5e No Re-Entry Message
Exterior grade
Client:
Project:
Architect / Engineer:
AP23
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Inside Stair No Re-Entry Message
Emergency Exit Message
Egress identifier Egress stair landing sign
L6 L7 L8
NO RE-ENTRY
ON THIS FLOOR
Re-enter down to floor 1
Re-enter up to floor 4
Serves Floors B,1-9 Exit Down to 1 Roof Access
STAIR 14
Floor 5 stair 2
FLOOR 5
.0
0”
L9.x
EXIT
FLOOR 2
stair c fire exit
Keep Door Closed5
Emergency Exit Only
L7v L9v
Client:
Project:
Architect / Engineer:
AP24
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Stair egress path identifier
Stair egress path identifier for inpatient
Metal Health spaces
Automatic Door Message
In case of fire emergency do not use elevators use exit stairs
Crash Cart Inside
L12 L14 Elevator Use
Message Emergency info message
.0
0”
L10.x L10m.x L11
STAIR C
FLOOR 1
EXIT ROUTE
stair c fire exit
Keep Door Closed
Automatic Fire Door
DO NOT BLOCK
This fire door is arranged to swing closed automatically
Do not block the doorway or place any article in contact with the door
L15
NO
EXIT
STAIR C
FLOOR 1
EXIT ROUTE
stair c fire exit
Keep Door Closed
L14v
Client:
Project:
Architect / Engineer:
AP25
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Accessible Restroom near elevators
N4 Accessible Message
N3 N3mN1 N1m N2 N2m
ATTENTION ATTENTIONNOTICE
If you are or think you may be pregnant, notify staff prior to examination
NO Food Drinks Cell Phones Headphones
For SIM Lab Assistance or Access Call 7-2440 or Visit The Education Service Office In Basement Room BC 314-a-d
For SIM Lab Assistance or Access Call 7-2440 or Visit The Education Service Office In Basement Room BC 314-a-d
Small notice Small notice Inpatient Mental Health spaces
Large notice Large notice Inpatient Mental Health spaces
Pregnancy or other notice
Pregnancy or other notice
Inpatient Mental Health spaces
0.
2C-901A3 2a901a3 women
WOMEN
i6.x
If you are or think you may be pregnant, notify staff prior to examination
NOTICE
Please check-in at kiosk and then be seated
N1v
N3v
N2v
Client:
Project:
Architect / Engineer:
AP26
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Push
Button to
Open Door
N8 Automatic Door
Message
N6mN6 8 ½ x 11 paper insert - landscape Inpatient Mental Health spaces
8 ½ x 11 paper insert - landscape
N6v
Vinyl backer
N5 N7N5m 8 ½ x 11 paper insert - portrait
8 ½ x 11 paper insert - portrait to be used below Inpatient Suite Signs
8 ½ x 11 paper insert - portrait
Health spaces
Client:
Project:
Architect / Engineer:
AP27
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
N10 N21
Destination
Destination
Destination
Destination
Destination
Destination
Destination
Destination
CLINIC #
Current Services
N20
RESTRICTED AREA
Patients & Staff Only Beyond This Point
2-sided
See Nurse To Request
Access
Client:
Project:
Architect / Engineer:
AP28
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
R2 R3 R6R1 R1m
CAUTION
Radioactive
Material
CAUTION
Biohazard
CAUTION
Biohazard
Radiation Warning Oxygen Warning General Caution
Biohazard Warning Biohazard Warning Inpatient Mental Health spaces
CAUTION
Oxygen In Use
No Smoking No Open Flames
CAUTION
Watch Step
R2v
R2v
Client:
Project:
Architect / Engineer:
AP29
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
R8 R8mR7 R7m
Authorized Personnel
Only Staff Only
Restrictive Message Restrictive Message Inpatient Mental Health spaces
Restrictive Message Restrictive Message Inpatient Mental Health spaces
R9 R10
DO NOT CLOSE
EXCEPT IN
EMERGENCY
Med. Gas Do Not Close Warning
Medical Gas Zone Valve
Do not park equipment in front of Zone Valve
Med. Gas Do Not Park EQ. Warning
Authorized Personnel
Only Staff Only
R7v
Client:
Project:
Architect / Engineer:
AP30
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
V1 Public Entry Door
Vinyl Graphics
VA North Texas Health Care System
Main Entrance Outpatient Clinics Building 2J
Client:
Project:
Architect / Engineer:
AP31
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
80” A.F.F minimum overhead clearance
84” A.F.F preferred overhead clearance
60” A.F.F maximum tactile text baseline
48” A.F.F minimum tactile text baseline
40” A.F.F minimum visual character (text) baseline
70” A.F.F maximum height for text smaller than 2” high
Signage Installation Height
Building 2
Building 60
Building 60
Restrooms Building 1
Building 1
Building 2
Building 2
Building 74D
D
C
C
G
G
F C D E
FLOOR FLOOR
3 1
Destination
Check-Out
Destination Destination
Destination
Patient Lounge
Destination Destination
Destination Destination
DestinationDestination
Destination
Destination
Destination
Destination
Destination
Destination
Restroom
Destination
Destination
Destination
Destination
Destination
DestinationDestination
Destination
Destination
FLOOR 3
FLOOR 3
FLOOR 3
Hospital Hospital Hospital
2 2 2BUILDING BUILDING BUILDING
W3.x W4.xW2.xW1.x
W5.2xW5.1x
W7.2x W8.2xW7.1x W8.1x
W6.2xW6.1x
ED
2BUILDING 74BUILDING
.p suffix
.s suffix .y suffix
.b suffix
.b suffix .c suffix .p suffix
.s suffix .t suffix .y suffix
.t suffix
2JBUILDING
.c suffix
1BUILDING 60BUILDING
W2, W3 and W4 series sign types header graphics vary by suffix letter as follows:
W5 and W6 sign types floor ID insert colors vary by suffix letter as follows:
FLOOR
FLOOR
FLOOR
FLOOR
X
X
X
FLOOR
FLOOR
X
X
Small Eye-Level Directional w/ no backer
1-sided OH Directional
1-sided OH Directional
1-sided OH Directional
1-sided OH Directional
2-sided OH Directional
2-sided OH Directional
2-sided OH Directional
2-sided OH Directional
Small Eye-Level Directional Medium Eye-Level Directional Large Eye-Level Directional
Client:
Project:
Architect / Engineer:
AP32
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
Signage Installation Height
6' -8
F1
Custom Display for Existing Niches at B Elevators, Floor 1, Building 2J
Exact Graphics & Content in-Progress
SOUTH ELEVATION
NORTH ELEVATION
ED ED
ED
6' -8
Client:
Project:
Architect / Engineer:
AP34
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
ElevatorsB
B B
Signage Installation Height i41
Custom elevator portal surround and ceiling sign for B Elevators, Building 2J, Floor 1
Client:
Project:
Architect / Engineer:
AP36
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction TMi50
Custom information desk ID panel on stand-offs Main Info Desk, Building 2J, Floor 1
Signage Installation Height
Client:
Project:
Architect / Engineer:
AP37
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
W9.1 W9.2
Individual dimensional letters/graphics applied to existing wall Clinics Atrium, Building 2J, Floor 1
Overhead 2-sided directional Clinics Atrium, Building 2J, Floor 1
Signage Installation Height
Retail Store & Starbucks
Buildings 1,2,60,74
Eagle Atrium
Elevator
Elevator
Information Desk
A
B
Eagle Atrium
South EntrancePatriot Retail Store
RestroomsBuildings 1,2,60,74
FLOOR
Client:
Project:
Architect / Engineer:
AP38
Dallas VAMC Wayfinding & Signage
Wayfinding Associates
Design with a sense of Direction
TM
W21
Individual dimensional letters/graphics applied to existing wall Eagle Atrium, Building 2J, Floor 1
Signage Installation Height
Elevators Elevators
Bldgs 1, 60, 74 Retail Store & Starbucks
E N T E R I N G B U I L D I N G 2
C
D E
File details come from the government source that posted it. Updated .