36C25718Q9557-000.docx
DOCX document 15 KB Posted
- Solicitation number
- 36C25718Q9557
About this file
36C25718Q9557 36C25718Q9557.docx
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FedBizOpps Sources Sought Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Sources Sought Notice Rev. March 2010 D NEW-GSI Typstar Pro-ASPS- 671-18-2-039-0201(VA-18-00055072) 78229 36C25718Q9557 N 334210 Department of Veterans Affairs VISN17 Network Contracting Activity 7400 Merton Minter Blvd. (10N17/90C) San Antonio TX 78229 Dr. Vinicky Ann Ervin Ph.D.
All intereste parties shall contact Dr. Ervin via email at 7:00AM CST on 20 June 2018.
Audie L. Murphy VA Hospital 7400 Merton Minter Blvd.
San Antonio TX 78229
USA
vinicky.ervin@va.gov Business
| ITEM NUMBER |
| DESCRIPTION OF SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 0001 |
| Item Number: 8108266 Grason Stadler Tympstar Pro Includes: 8101894 IP 30 Insert Contra Phone; 8013167 Probe Mount - Shoulder; 8013166 Probe Mount - Wrist; 8006690 Probe Mount - Clip Assembly; 81089 |
LOCAL STOCK NUMBER: 8108266
| 10.00 |
| EA |
| $00.00 |
| $00.00 |
| GRAND TOTAL |
| $00.00 |
SALIENT CHARACTERISTICS FOR GSI Tympstar Pro, Clinical Middle Air Analyzer – Hearing Aid Tester It includes the following main pieces of equipment:
GSI Tympstar Pro; Clinical Middle Air Analyzer; Various Probe Accessories Features:
The GSI Tympstar Pro improves workflow capabilities and have customizable protocols. It can also be an Stand-Alone System and can store 100 test sessions, comments with wireless keyboard and is EMR/EHR compatible. This Tympstar has the largest display area of any tympanometry on the market allowing for a bright and easy to view image as the test progresses. Customizable user tests and pre-defined protocols for either screening or diagnostic immittance evaluation of the middle ear; Automatic detection of both ipsilateral and contralateral acoustic reflexes for seamless evaluation of neural integrity; Audiometric Data Management through a single data transfer button press; Integrated 12-inch color touch screen
Other Features include the following:
| Auto Star with seal for screening and diagnostic tympanograms |
| Multiple probe tone frequencies |
| Pressure Sweep Speeds: 12.5, 50, 200, 600/200 daPa/second |
| Manual pump control |
| Multiple Immittance Display (Y/B/G) |
| Zoom function for detailed analysis of results |
| Customizable tympanogram labels or Jerger classification |
| Start tests or switch ears from probe box |
| Automatic detection of acoustic reflex thresholds |
| Click stimulus for reflex |
| Multiplex Pulsed-Tone Stimuli for reflex |
| Pre-defined protocols and customizable user tests |
| Eustachian Tube Function – Intact or Perforated TM. |