564-24-104 Design Amendment 02.pdf

PDF 22 MB Posted

Attached to
Z2DA--CON - 564-24-104 - Renovate Space for Logistics (B-1)
Solicitation number
36C25624R0102
Issued by

About this file

This document is a Design Amendment to Solicitation 36C25624R0102, which is for the renovation of space for logistics at facility 564-24-104 for the Department of Veterans Affairs, Veterans Integrated Service Network 16. The amendment provides revised design specifications and drawings for the renovation project. Key details include a revised project schedule, updated design requirements, and clarification on construction materials and finishes. The amendment also addresses several questions submitted by prospective offerors. The overall scope of the project remains the renovation of approximately 12,000 square feet of existing space to support logistics operations. Offers in response to the solicitation are due by June 15, 2023, with a contract award expected by July 1, 2023. The procurement is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB).

View the file

Other files

File Type Posted
564-24-104 PRE_BID RFIs_Batch 2_Answered.docx DOCX document
564-24-104 Design Amendment 03.pdf PDF
564-24-104 PRE_BID RFIs_Batch 2_Answered.docx DOCX document
36C25624R0102 Amendment 0004.docx DOCX document
Amendment 0003 36C25624R0102.docx DOCX document
564-24-104 Sheet HA101-A.pdf PDF
564-24-104 PRE_BID RFIs_ Answered.pdf PDF
Amendment 0002 36C25624R0102.docx DOCX document
564-24-104 Site Visit Instructions.docx DOCX document
Amendment 0001 for 36C25624R0102.docx DOCX document
36C25624R0102 Solicitation_Final.docx DOCX document
564-24-104 Bid Drawings.pdf PDF
564-24-104 Specifications.pdf PDF
564-24-104 SOW Renovate Space for Logistics.docx DOCX document
36C25624R0102 Solicitation_Final.docx DOCX document
564-24-104 Site Visit Instructions.docx DOCX document
564-24-104 EXHIBIT A PERFORMANCE RELEVANCY SURVEY.docx DOCX document
564-24-104 Wage Determination AR20240128.docx DOCX document
564-24-104 EXHIBIT B CONTRACTOR EVALUATION FORM.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Harrell Design Group, PC

AMENDMENT 02

July 11, 2024

RENOVATE SPACE FOR LOGISTICS (B-1)

VA PROJECT #564-24-104

Veterans’ Healthcare System of the Ozarks

HDG Project Number: 19022-A

I. BIDDER’S QUESTION RESPONSES: not applicable to this amendment.

II. DRAWINGS:

1. The following nineteen (19) drawings are revised as follows:

a. GI501-A:

i. Detail B3, Equipment Pad: Equipment pad length and width to be 8” greater than the equipment mounting plate/footprint versus previous 12” dimension.

b. GC102-A:

i. A room tag was added to Corridor L109.

ii. The scope box boundary was adjusted to include the wall change in the Service

Elevator Lobby.

c. AE101-A:

i. A room tag was added to Service Elevator Lobby 1-L051.

d. AE102-A:

i. A bar scale was added to Detail D1.

ii. A room tag was added to Corridor L109 on Drawing F4 – First Floor – Construction

Plan.

iii. Modification of existing wall condition relating to Room L101 – Electrical on

Drawing F4 – First Floor – Construction Plan.

iv. Addition of smoke wall to vestibule found between Room C231 – Service Elevator

Lobby and Room L102 – Breakdown on Drawing F4 – First Floor – Construction

Plan.

v. Placement of equipment pad was modified in Room M1-3 – Mechanical Room on

Drawing F4 – First Floor – Construction Plan.

vi. Size of equipment pad was modified in Room M1-3 – Mechanical Room on

Drawing F4 – First Floor – Construction Plan.

vii. Elevation markers were deleted from HAC L113 and Toilet L111.

e. AE111-A:

i. Relocation of 2 supply diffusers on Drawing F4 – First Floor – Reflected Ceiling

Plan.

f. AE201-A:

i. Bar scales were added to elevations C4, C6, and C8.

g. AF601-A

i. Elevation markers were deleted from HAC L113 and Toilet L111.

ii. Tags were added to all signage.

h. AF602-A:

i. The Signage Schedule was updated to reflect the correct room names, room numbers, and quantities of all signage.

ii. Corridor L109 was added to the Finish Schedule.

i. FA101-A

i. Added area and notes about keeping an area in Sterile Storage free from overhead conduits and equipment, for the future Cart Lift.

j. PD101-A

i. Added demolition of drainpipe from the medical air vacuum to floor drain.

ii. Keynote 11 was added to describe drainpipe demolition.

k. PL201-A

i. Added installation of drainpipe to floor drain plan north of the dental air compressor.

ii. Keynote 12 was added to describe drainpipe installation.

l. MD101-A

i. Location of existing duct was modified to reflect existing conditions.

ii. Extent of demolition was revised to leave existing fire dampers in the wall.

m. MH101-A

i. Location of existing duct was modified to reflect existing conditions.

ii. Location of connection point was revised to coordinate with updated existing ductwork.

iii. The locations of two supply diffusers were revised in Sterile Storage, Overflow

Room L112.

iv. Location of VAV-LOG-1 was revised.

v. Supply air ductwork was revised to coordinate with VAV-LOG-1 updated location.

vi. Location of 1-AHU-LOG was revised.

vii. Outside air ductwork was revised to coordinate with 1-AHU-LOG updated location.

n. MP101-A

i. Hot water piping was revised to coordinate with VAV-LOG-1 updated location.

ii. Hot water and chilled water piping was revised to coordinate with 1-AHU-LOG updated location.

iii. Connect-to-existing symbol was added to the new chilled water tie-in locations.

o. EG001-A

i. Added symbol for access points.

p. ED101-A

i. Added notes about existing items to be rerouted and demolished in existing pipe chase

q. EL101-A

i. Added area and notes about keeping an area in Sterile Storage free from conduits and equipment, for the future Cart Lift.

r. EP101-A

i. Added area and notes about keeping an area in Sterile Storage free from conduits and equipment, for the future Cart Lift.

ii. Added notes about existing items to be rerouted in existing pipe chase.

s. EY101-A

i. Added area and notes about keeping an area in Sterile Storage free from conduits and equipment.

ii. Added access points to plan.

III. SPECIFICATIONS: not applicable to this amendment.

END OF AMENDMENT 02

A0 7/8" 1 1/2" - - -

A1 1 5/8" 2 1/4"

A2 2 1/2" 3 1/8"

A6 6" 6 5/8"

A8 8" 8 5/8"

ACOUSTIC INSULATION

C1 1 5/8" 2 7/8"

C2 2 1/2" 3 3/4"

C3 3 5/8" 4 7/8"

C4 4" 5 1/4"

C6 6" 7 1/4"

C8 8" 9 1/4"

1 HR U419 47

1 HR U419 47

1 HR U419 47

1 HR U419 47

REFER TO WALL DETAIL

SHEET AND PARTITION

NOTES FOR HEAD DETAILS

PARTITION TYPE - A

PARTITION TYPE - C

MARK STUD SIZE OVERALL THK. "R" RATING FIRE TESTMARK STUD SIZE OVERALL THK. "R" RATING FIRE TEST

ONE LAYER OF 5/8" GWB

ON METAL STUDS

/2

ACOUSTIC INSULATION

REFER TO WALL DETAIL

SHEET AND PARTITION

NOTES FOR HEAD DETAILS

ONE LAYER OF 5/8" GWB

EACH SIDE OF METAL

STUDS

HOLD BOTTOM OF GWB 1/2"

OFF FINISH FLOOR. NO

EXCEPTIONS

/2

"A" STC RATING

PARTITION MODIFICATIONS

"A" STC RATING

PARTITION MODIFICATIONS

FLOOR

APPLY CONTINUOUS BEAD

ACOUSTIC SEALANT UNDER

FLOOR TRACK

COMPOSITE WALL

NON-COMPOSITE WALL

APPLY CONTINUOUS BEAD

ACOUSTIC SEALANT UNDER

FLOOR TRACK

HOLD BOTTOM OF GWB 1/2"

OFF FINISH FLOOR. NO

EXCEPTIONS

FLOOR

INSTALL HORIZONTAL STUD

BRIDGING VERTICALLY

SPACED PER

MANUFACTURER'S TABLES

A4 4" 4 5/8"

RUNNER TRACK. REFER TO

DETAIL F8 ON SHEET AE511-

A

RUNNER TRACK. REFER TO

DETAIL F8 ON SHEET AE511-

A

A00 - 1/4" GWB - - -

PARTITION TYPE - R

FOR SHAFT WALL

CONSTRUCTION REFER TO UL

DETAIL U415 SYSTEM A

ONE LAYER OF

5/8" TYPE X GWB

O.C.

2' - 0"

2 1/2" DEEP GALVANIZED

STEEL STUD

1" TYPE X SHAFT LINER

PANEL GWB

S1 2 1/2" 4 3/4" 1 HR U415 -

MARK STUD SIZE OVERALL THK. "R" RATING FIRE TEST "A" STC RATING

/8

STRUCTURESTRUCTURE

CONTINUOUS STRAPS AT 16"

O.C. TO SECURE INSULATION

ACOUSTIC

INSULATION

M

IN

IM

U

M

M

IN

IM

U

M E

M B

E D

M E

N T

I N

C O

N C

R E

T E

/2

/2

THIS SPACE FOR PROJECT TITLE.

LETTERING TO BE HELVETICA 5" HIGH CENTERED

BETWEEN LETTERING ABOVE AND BELOW

ONE OR TWO LINES AS REQUIRED

DESIGNED AND SUPERVISED BY:

DEPARTMENT OF VETERANS AFFAIRS

WASHINGTON, D.C.

GENERAL CONTRACTORDESIGNER

THIS SPACE FOR

CONTRACTOR

INFORMATION

2" 7' - 8" 2"

8' - 0"

VA LOGO. OBTAIN APPROVED

GRAPHIC FROM COR

PROJECT TITLE LETTERING TO BE

APPROVED VA BLUE

2x BORDER MEMBER

PAINT BLACK

METAL SIGN FACE - 3/4"

MINIMUM BACKING THICKNESS.

PAINT WHITE ENAMEL

CONTRACTOR INFORMATION

LETTERING TO BE 1 1/2" HIGH

HELVETICA

SUPPORT POSTS AND FRAMING

MEMBERS

PAINT WHITE ENAMEL

DESIGNER INFORMATION:OBTAIN

APPROVED GRAPHIC FROM

DESIGNER

2x BACK FRAME AND CROSS

BRACING

PAINT WHITE ENAMEL

NOTES:

1. LOCATE SIGN ON CAMPUS PER VA-COR.

2. SEE SPEC SECTION 010000 FOR SIMILAR

SAFETY SIGN.

3. LOCATE BOTH SIGNS ADJACENT TO EACH

OTHER.

AT NEW SLABS, PROVIDE #3 BARS 12"

O.C. EW IN THE BASE AND DOWEL

BASE TO FLOOR. MIN EMBEDMENT OF

DOWELS TO BE 1/2 FLOOR THICKNESS

OR 3" MIN

AT EXISTING SLABS, ROUGHEN THE

SURFACE OF THE EXISTING

CONCRETE TO A 1/4"

AMPLITUDE. CLEAN ALL DEBRIS FROM

THE SURFACE AND APPLY AN EPOXY

BONDING AGENT PER

MANUFACTURER’S INSTRUCTIONS

PRIOR TO POURING THE EQUIPMENT

PAD.

M

IN

L /1

NOTES:

1. L & W TO BE 8" GREATER THAN THE

EQUIPMENT MOUNTING PLATE /

FOOTPRINT

2. PROVIDE 3/4" CHAMFER AROUND

ENTIRE UPPER EDGE

3. PAINT ENTIRE PAD SAFETY YELLOW

IN EPOXY FLOOR PAINT

VA STANDARD DETAIL SD230541-03

SECTION A-A (PAD NOT POURED WITH SLAB )

EQUIPMENT

PROVIDE DOUBLE

REINFORCING IN AREA

OF PAD

M

IN

L /1

SECTION A-A (PAD POURED WITH SLAB )

EQUIPMENT

16" MIN

L

W

A

A

FLOOR

5D

2D

WELD HEAD TO PLATE OR

BEND OVER 5D

PIPE SLEEVE (5D, 3" MIN.

LENGTH)

ANCHOR BOLT

EQUIPMENT PAD

SCHEDULED PARTITION

WALL AND FINISH

(NEW WALL)

SCHEDULED TILE, SEAL POROUS TILE,

AND GROUT (SEE MANUFACTURER'S

INSTRUCTIONS)

5/8" GYPSUM WALL BOARD,

PAINT AS SCHEDULED

"J" CASING BEAD

8' - 0" A.F.F. U.N.O (SEE ELEVATIONS)

LINE OF CEILING, SEE

REFLECTED CEILING PLANS

FOR INFORMATION

EPOXY GROUT, SEAL POROUS

TILE, AND GROUT (SEE

MANUFACTURER'S INSTRUCTIONS)

LATEX-PORTLAND CEMENT

BOND MORTAR

TILE COUNCIL ASSOCIATION

TILE SETTING METHOD (TCA) W243

T2 - FULL HEIGHT TILE CONDITION

FIBER-REINFORCED

WATER RESISTANT

GYPSUM BACKER

BOARD

VARIES

AS SCHD

SCHEDULED TILE, SEAL POROUS

TILE, AND GROUT (SEE

MANUFACTURER'S INSTRUCTIONS)

5/8" GYPSUM WALL BOARD,

PAINT AS SCHEDULED

"J" CASING BEAD

5' - 0" A.F.F. U.N.O (SEE ELEVATIONS)

TILE COUNCIL ASSOCIATION

TILE SETTING METHOD (TCA) W243

EPOXY GROUT, SEAL POROUS

TILE, AND GROUT (SEE

MANUFACTURER'S INSTRUCTIONS)

LATEX-PORTLAND CEMENT

BOND MORTAR

T1 - WAINSCOT TILE WALL CONDITION

CONTINUOUS BEVELED

ALUMINUM TRIM CAP,

MITERED AT CORNERS, TYP.

ACOUSTIC INSULATION

RED

WHITE

BLUE

JOINT

BRACING

2"X4" FRAME

AND BRACE IN

BACK

WOOD

STRIPS

CONTRACTOR'S NAME

THE LIFE YOU SAVE MAY BE YOUR OWN

THIS PROJECT

HAS WORKED 0 00 DAYS

WITHOUT A LOST TIME ACCIDENT

ZERO

in ON SAFETY

BLUE

BLUE

OUTLINE

WITH WHITE

INTERIOR

4"x4" IF SIGN IS

INSTALLED ON

GRADE FINISH GRADE

ELEVATION

ALL LETTERING TO BE

PAINTED BLACK WITH

EXCEPTION OF PROJECT

TITLE, WHICH IS TO BE

PANTONE 19-4035 TCX

4 " -3

/4

4'-0"

V A

R

IE

S

U.S. Department of Veterans Affairs

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

VA FORM 08 - 6231

A

FULLY SPRINKLERED

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28277

704-814-1346

CONSULTING STRUCTURAL ENGINEERS

POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2024

WWW.HARRELLDG.COM

21 JUNE 2024

564-24-104

FAYETTEVILLE VA MEDICAL CENTER

HDG PROJECT: 19022

CONSTRUCTION

DOCUMENTS SUBMISSION

RENOVATE SPACE FOR LOGISTICS

(B-1)

A u to d e s k D o c s /1

F a y e tt e v ill e I D

IQ

P ro je c t

N o

-1

-4

R e n o v a ti o n o f S

P S

/1

A R

C H

R

.r v t

/1

/2

:5

:0

P

M

GI501-A

MSJC

PARTITION TYPES AND STANDARD

DETAILS

0 1 1/2'1'1/2'

1' 2' 3'0

1. REFER TO PLANS FOR LOCATION OF PARTITION TYPES. C4

(UNRATED) IS THE TYPICAL PARTITION TYPE UON.

2. ERECT PARTITIONS IN ORDER OF RATING PRIORITY BEGINNING WITH

HIGHEST FIRE RATED PARTITION. CONSTRUCTION OF HIGHER

RATED PARTITIONS SHALL BE CONTINUOUS PAST/THROUGH LOWER

RATED INTERSECTING PARTITION.

3. ALL STUD GAUGES AND LIMITING HEIGHTS IN GYPSUM BOARD

REFERENCE SPECIFICATIONS.

4. ALL PARTITIONS CONTAINING PLUMBING OR HAVING AN EXTERIOR

FACE TO BE INSULATED.

5. THE FOLLOWING LIST OF ROOMS (IF USED) SHALL HAVE THEIR

PERIMETER PARTITIONS INSULATED USING THERMAL INSULATION: (1)

ALL ELECTRICAL / MECHANICAL ROOMS; (2) A/V EQUIPMENT /

LIGHTING ROOMS; AND (3) STAIRWAYS.

6. ALL NEW STUD WALLS RECEIVE ACOUSTIC INSULATION UNLESS

NOTED OTHERWISE.

7. ALL PARTITIONS SHALL EXTEND FULL HEIGHT TO UNDERSIDE OF

DECK / INTERSTITIAL ABOVE OR HAVE THEIR TOPS BRACED PER

PARTITION BRACING DETAILS.

8. ALL RATED PARTITIONS TO EXTEND FROM TOP OF SLAB TO

UNDERSIDE OF STRUCTURE. SEAL ENTIRE PERIMETER WITH

FIRESTOP SEALANT UON.

9. ALL INTERIOR ROOF AND OVERFLOW DRAIN LEADERS TO BE

WRAPPED CONTINUOUSLY WITH SOUND ATTENUATION INSULATION.

10. INSTALL FRAMING AND GWB TO OFFSET AROUND STRUCTURAL

MEMBERS OR OTHER OBSTRUCTIONS TO MAINTAIN FIRE RESISTIVE

RATINGS.

11. WHERE GWB EXTENDS TO THE UNDERSIDE OF STRUCTURE, STOP

GWB 1/2” BELOW LINE OF STRUCTURE AND SEAL AS REQUIRED.

12. NON-RATED PARTITIONS SHALL HAVE ENTIRE PERIMETER SEALED

WITH ACOUSTICAL SEALANT, UON.

13. REFER TO MECHANICAL DRAWINGS FOR DETAILS ON PIPE

PENETRATIONS THROUGH ACOUSTICAL PARTITIONS AS WELL AS

RATED PARTITIONS.

14. INSTALL METAL STUD BLOCKING IN PARTITIONS AT ALL WALL

MOUNTED EQUIPMENT, WHETHER CC, VC OR VV.

15. ALL PARTITIONS SCHEDULED TO RECEIVE TILE, IN BATHING ROOMS

AND/OR LOCATED ADJACENT TO OR BEHIND PLUMBING FIXTURES

SHALL BE CONSTRUCTED OF WATER-RESISTANT CORE GWB.

16. FOR MOLD PREVENTION, DO NOT INSTALL GWB IN DIRECT CONTACT

WITH THE FLOOR. ALL GWB SHALL BE SHIMMED 1/2” OFF THE FLOOR

WITH NON-POROUS SHIMS. PLASTIC NON-POROUS HORSESHOE

SHIMS ARE RECOMMENDED. GWB SHIMS ARE NOT ACCEPTABLE.

17. CABLES PENETRATING RATED PARTITIONS (WITH OR WITHOUT

SLEEVES) SHALL BE SECURED ON BOTH SIDES OF THE PARTITION.

METHOD OF SECURING THE CABLES SHALL BE SLEEVED TO

PRECLUDE ANY MOVEMENT OF THE CABLE DISTURBING THE

INTEGRITY OF THE PENETRATION FIRE - STOPPING ASSEMBLY. SEE

SPECIFICATIONS.

18. REFER TO DRAWINGS FOR TYPICAL WALL FRAMING FOR FIRE

DAMPERS IN RATED WALLS. COORDINATE EXACT FRAMING

REQUIREMENTS WITH FIRE DAMPER MANUFACTURER. COORDINATE

ALL PARTITION CONSTRUCTION WITH MECHANICAL PRIME

CONTRACTOR PRIOR TO COMMENCING PARTITION CONSTRUCTION.

GENERAL CONTRACTOR SHALL OBTAIN FROM THE MECHANICAL

CONTRACTOR THE PROPER INSTALLATION INSTRUCTIONS FOR ALL

FIRE AND SMOKE DAMPERS AND SHALL PROVIDE THE REQUIRED

METAL FRAMING, DRYWALL, ETC., ACCORDING TO THESE

INSTRUCTIONS. INSTALLATION INSTRUCTIONS TO BE SUBMITTED TO

THE ARCHITECT AND OWNER FOR REVIEW.

19. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FIRE AND

SMOKE SEALED PENETRATIONS IN ACCORDANCE WITH TESTED AND

APPROVED PENETRATION SEALING SYSTEM FOR THE PARTITION

CONSTRUCTION / FIRE RATING AND THE PENETRATING ELEMENTS.

20. PARTITION TYPES AS NOTED BY THE SYMBOL CONTINUE BETWEEN

ROOM/SPACE CORNERS OR ANY INTERSECTING PARTITION.

21. DIFFERING PARTITION TYPES SHALL ALIGN SO THAT WALL PLANES

CONTINUE UNBROKEN WITHIN/ACROSS ROOMS AND/OR SPACES.

22. COVER ALL EXISTING EXTERIOR WALLS AND MASONRY / CONCRETE

WALLS WITH PARTITION TYPE A00 UON.

23. INSTALL BRIDGING ON NON-COMPOSITE STUD WALLS.

INTERIOR PARTITION NOTES

PARTITION TAG NOTES

PARTITION TAGS ARE READ LEFT TO RIGHT:

1. THE FIRST CHARACTER INDICATES WHICH PARTITION / BARRIER

TYPE TO REFERENCE FOR CONSTRUCTION.

2. THE SECOND CHARACTER INDICATES A REFERENCE TO THE

STRUCTURAL CORE THICKNESS (STUD OR CMU).

3. THE THIRD CHARACTER INDICATES:

"A" - ACOUSTICAL PARTITION

"R" - FIRE RATED

"S" - SMOKE-RESISTIVE PARTITION (UNRATED)

"T" = "R" + "A" - FIRE RATED / ACOUSTICAL BARRIER

"V" = "R" + "S" - FIRE RATED / SMOKE BARRIER

"W" = "A" + "S" - ACOUSTICAL / SMOKE RESISTANT PARTITION

"Z" = "R" + "S" + "A" - FIRE RATED / SMOKE / ACOUSTICAL BARRIER

EXAMPLE:

A PARTITION TYPE C3T INDICATES A 4 7/8" 1 HOUR RATED BARRIER WITH

ACOUSTICAL INSULATION

NOTE:

THE RATING (FIRE) AND UL ASSEMBLY DESIGNATION ONLY APPLIES

WHEN THE PARTITION SUFFIX "R" IS ADDED TO THE WALL TAG(S)

OTHERWISE THE PARTITION TYPE IS A NON-RATED WALL AND / OR SOME

OTHER DISTINCTION NOTED UNDER PARTITION TAG NOTES.

3/4" = 1'-0" E3

PROJECT SIGNS

1 1/2" = 1'-0" B3

EQUIPMENT PAD

TILE CONDITIONS

WALL TAG SUFFIX TILE CONDITIONS (WHERE APPLICABLE) WALL TAGS I.E., C3T-T2

WHERE APPLICABLE SEE TILE CONDITIONS SUFFIX -T1, OR -T2

Revision Number Revisions: Date:

1 AMENDMENT 02 07/11/2024

1 1/2" = 1'-0" F3

PROJECT SAFETY SIGN

0 1 1/2'1'1/2'

F .E

.C

F .E

.C

F.E.C.

F.E.C.

F.E.C.

F.E.C.

F.E.C.

F .E

.C

F.E.C.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE FOLLOWING INFECTION CONTROL PRECAUTIONS DEPENDING UPON THE

AREA CLASS DESIGNATION

TYPE OF CONSTRUCTION/PROJECT ACTIVITY TABLE

GROUP 1-LOW RISK

● OFFICE AREAS (NON-

CLINICAL)

PATIENT RISK GROUP TABLE

GROUP 2-MEDIUM RISK

GROUP 3-HIGH RISK GROUP 4-HIGHEST RISK

INFECTION CONTROL MATRIX-CLASS OF PRECAUTIONS: CONSTRUCTION PROJECT BY PATIENT RISK

PATIENT RISK GROUP TYPE A

I I I

III

NOTE: INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION

ACTIVITY AND RISK LEVEL INDICATE THAT CLASS III OR CLASS IV CONTROL PROCEDURES

ARE NECESSARY.

LOW RISK GROUP 1

MEDIUM RISK GROUP 2

HIGH RISK GROUP 3

HIGHEST RISK GROUP 4

1. EXECUTE WORK BY METHODS TO MINIMIZE RAISING DUST FROM CONSTRUCTION

OPERATIONS.

2. IMMEDIATELY REPLACE A CEILING TILE DISPLACED FOR VISUAL INSPECTION.

1. INCLUDES ALL ACTIVITIES REQUIRED BY CLASS I.

2. PROVIDE ACTIVE MEANS TO PREVENT AIRBORNE DUST FROM DISPERSING INTO

ATMOSPHERE.

3. WATER MIST WORK SURFACES TO CONTROL DUST WHILE CUTTING.

4. SEAL UNUSED DOORS WITH DUCT TAPE.

5. BLOCK OFF AND SEAL AIR VENTS.

6. PLACE ADHESIVE WALK-OFF MATS AT ENTRANCE AND EXIT OF WORK AREA. REPLACE

USED MATS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

7. REMOVE OR ISOLATE HVAC SYSTEM IN AREAS WHERE WORK IS BEING DONE TO

PREVENT CONTAMINATION OF DUCT SYSTEM.

1. INCLUDES ALL ACTIVITIES REQUIRED BY CLASS II.

2. OBTAIN INFECTION CONTROL PERMIT FROM HOSPITAL SAFETY OFFICER OR

FACILITIES MANAGEMENT MAINTENANCE AND ENGINEERING DEPARTMENT BEFORE

CONSTRUCTION BEGINS.

3. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO

PREVENT CONTAMINATION OF DUCT SYSTEM.

4. COMPLETE ALL CRITICAL BARRIERS BEFORE CONSTRUCTION BEGINS OR IMPLEMENT

CONTROL CUBE METHOD.

5. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA-EQUIPPED AIR

FILTRATION UNITS.

6. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED

CONTAINERS.

7. COVER TRANSPORT RECEPTACLES OR CARS. TAPE COVERS.

8. WET MOP AND/OR VACUUM WITH HEPA FILTERED VACUUM BEFORE LEAVING WORK

AREAS.

1. WIPE SURFACES TO REMOVE DUST.

1. WIPE WORK SURFACES WITH

DISINFECTANT.

2. CONTAIN CONSTRUCTION WASTE

BEFORE TRANSPORT IN TIGHTLY

COVERED CONTAINERS.

3. WET MOP AND/OR VACUUM WORK

AREA WITH HEPA FILTERED VACUUM

BEFORE LEAVING WORK AREAS.

4. REMOVE ISOLATION OF HVAC SYSTEM

IN AREAS WHERE WORK WAS BEING

PERFORMED.

1. REMOVE BARRIER MATERIALS

CAREFULLY TO MINIMIZE SPREADING

OF DIRT AND DEBRIS ASSOCIATED

WITH CONSTRUCTION.

2. CONTAIN CONSTRUCTION WASTE

BEFORE TRANSPORT IN TIGHTLY

COVERED CONTAINERS.

3. COVER TRANSPORT RECEPTACLES OR

CARTS. TAPE COVERING.

4. VACUUM WORK WITH HEPA-

FILTERED VACUUMS.

5. WET MOP WITH DISINFECTANT.

6. REMOVE ISOLATION OF HVAC SYSTEM

IN AREAS WHERE WORK WAS BEING

PERFORMED.

1. INCLUDES ALL ACTIVITIES REQUIRED BY CLASS III.

2. OBTAIN INFECTION CONTROL PERMIT FROM HOSPITAL SAFETY OFFICER OR

FACILITIES MANAGEMENT MAINTENANCE AND ENGINEERING DEPARTMENT BEFORE

CONSTRUCTION BEGINS.

3. ISOLATE HVAC SYSTEM IN AREAS WHERE WORK IS BEING DONE TO PREVENT

CONTAMINATION OF DUCT SYSTEM.

4. COMPLETE ALL CRITICAL BARRIERS OR IMPLEMENT CONTROL CUBE METHOD BEFORE

CONSTRUCTION BEGINS.

5. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA-EQUIPPED AIR

FILTRATION UNITS.

6. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES APPROPRIATELY. CONSTRUCT

ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS-THROUGH THIS ROOM SO THEY

CAN BE VACUUMED USING A HEPA VACUUM CLEANER BEFORE LEAVING WORK SITE OR

THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH TIME THEY

LEAVE THE WORK SITE.

7. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO WEAR SHOE COVERS. SHOE

COVERS MUST BE CHANGED EACH TIME THE WORKER EXITS THE WORK AREA.

8. PLACE ADHESIVE WALK-OFF MATS AT ENTRANCE TO WORK AREA WITH ANTEROOM.

REPLACE PER MANUFACTURER'S RECOMMENDATIONS.

9. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL EACH COMPLETED PROJECT

PHASE IS INSPECTED BY THE HOSPITAL SAFETY OFFICER, FACILITIES MANAGEMENT

MAINTENANCE AND ENGINEERING DEPARTMENT AND THOROUGHLY CLEANED BY THE

HOSPITAL ENVIRONMENTAL SERVICES DEPARTMENT OR THEIR CONTRACTED

ENVIRONMENTAL SERVICES COMPANY.

10. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED

CONTAINERS.

11. COVER TRANSPORT RECEPTACLES OR CARS. TAPE COVERING.

12. VACUUM WITH HEPA FILTERED VACUUM. WET MOP WITH DISINFECTANT AFTER

BARRIERS ARE REMOVED.

1. REMOVE BARRIER MATERIALS

CAREFULLY TO MINIMIZE SPREADING

OF DIRT AND DEBRIS ASSOCIATED WITH

CONSTRUCTION.

2. CONTAIN CONSTRUCTION WASTE

BEFORE TRANSPORT IN TIGHTLY

COVERED CONTAINERS.

3. COVER TRANSPORT RECEPTACLES

OR CARTS. TAPE COVERING.

4. VACUUM WORK WITH HEPA-

FILTERED VACUUMS.

5. WET MOP WITH DISINFECTANT

AFTER BARRIERS ARE REMOVED.

6. REMOVE ISOLATION OF HVAC SYSTEM

IN AREAS WHERE WORK WAS BEING

PERFORMED.

DURING CONSTRUCTION PROJECT UPON COMPLETION OF PROJECT

CLASS I

CLASS II

CLASS III

CLASS IV

INSPECTION AND NON-INVASIVE ACTIVITIES

INCLUDES BUT IS NOT LIMITED TO:

● REMOVAL OF CEILING TILES FOR VISUAL INSPECTION LIMITED TO 1

TILE IN 50 SQUARE FEET

● PAINTING (BUT NOT SANDING), WALL COVERING

● ELECTRICAL TRIM WORK, MINOR PLUMBING, AND ACTIVITIES THAT

DO NOT GENERATE DUST OR REQUIRE CUTTING OF WALLS OR

ACCESS TO CEILINGS OTHER THAN FOR VISUAL INSPECTION

TYPE A

SMALL SCALE, SHORT DURATION ACTIVITIES THAT CREATE MINIMAL DUST

INCLUDES BUT IS NOT LIMITED TO:

● INSTALLATION OF TELEPHONE AND COMPUTER CABLING

● ACCESS TO CHASE SPACES

● CUTTING OF WALLS OR CEILING WHERE DUST MIGRATION CAN BE

CONTROLLED

TYPE B

WORK THAT GENERATES A MODERATE TO HIGH LEVEL OF DUST OR

REQUIRES DEMOLITION OR REMOVAL OF ANY FIXED BUILDING

COMPONENTS OR ASSEMBLIES

INCLUDES BUT IS NOT LIMITED TO:

● SANDING OF WALLS FOR PAINTING OR WALL COVERING

● REMOVAL OF FLOOR COVERINGS, CEILING TILES AND CASEWORK

● NEW WALL CONSTRUCTION

● MINOR DUCT WORK OR ELECTRICAL WORK ABOVE CEILINGS

● MAJOR CABLING ACTIVITIES

● ANY ACTIVITY THAT CANNOT BE COMPLETED WITHIN A SINGLE

WORK SHIFT

TYPE C

MAJOR DEMOLITION AND CONSTRUCTION PROJECTS

INCLUDES BUT IS NOT LIMITED TO:

● ACTIVITIES THAT REQUIRE CONSECUTIVE WORK SHIFTS

● REQUIRES HEAVY DEMOLITION OR REMOVAL OF A COMPLETE

CEILING SYSTEM

● NEW CONSTRUCTION

TYPE D

ICRA GENERAL NOTES

● CARDIOLOGY

● ECHOCARDIOLOGY

● ENDOSCOPY-GI

● PHYSICAL THERAPY

● RADIOLOGY/MRI

● NUCLEAR MEDICINE

● RESPIRATORY CARE (EXCEPT -

BRONCHOSCOPY AREA)

● CAFETERIA

● OUTPATIENT AREAS-CLINICS AND OFFICES

(EXCEPTION: TRANSPLANT AND ONCOLOGY)

● EMERGENCY ROOM

● POST ANESTHESIA

● CARE UNITS

● LABOR AND DELIVERY

● PEDIATRICS

● ADMISSION/DISCHARGE

AREA

● LABORATORIES

● PHARMACY

● INPATIENT UNITS (NOT

OTHERWISE SPECIFIED)

● ALL OPERATING ROOMS INCLUDING LABOR

AND DELIVERY

● ANESTHESIA AND PUMP AREAS

● CENTRAL EQUIPMENT/STERILE SUPPLY

● CARDIAC CATHETERIZATION AND ANGIOGRAPHY

AREAS

● INTERVENTIONAL RADIOLOGY

● RADIATION ONCOLOGY

● ALL INTENSIVE CARE UNITS

● NEWBORN NURSERIES, INCLUDING NICU

● DIALYSIS UNIT

● ONCOLOGY-INPATIENT AND OUTPATIENT

● TRANSPLANT-INPATIENT AND OUTPATIENT

● PHARMACY ADMIXTURE

● NEGATIVE PRESSURE ISOLATION

ROOMS/AREAS (INCLUDING

BRONCHOSCOPY AREA)

TYPE B

II

II

III

III / IV

TYPE C

II

III

III / IV

III / IV

TYPE D

III / IV

IV

IV

IV

A. PROVIDE CONTAINMENT AS REQUIRED (BY HOSPITAL) INFECTION CONTROL REPRESENTATIVE FOR WORK OUTSIDE MAJOR AREA.

B. PROVIDE CONTAINMENT AT THE FLOOR BELOW FOR ANY WORK IN THE CEILING PLENUM.

C. PROVIDE TEMPORARY DOOR WITH GASKETING TO PREVENT THE MOVEMENT OF DUST.

D. PROVIDE TEMPORARY EMERGENCY EXIT FROM CONSTRUCTION ZONE; HOWEVER, ALL GENERAL CONSTRUCTION TRAFFIC SHOULD BE THROUGH VESTIBULE.

E. CONTRACTOR TO PROTECT ALL FINISHES INCLUDING (BUT NOT LIMITED TO) FLOORING, CEILING, WALL SURFACES, DOORS, AND DOOR FRAMES DURING THE MOVEMENT OF

MATERIALS TO/FROM LIMIT OF WORK. COORDINATE WITH COR AND SPECIFICATIONS FOR PROCEDURES/REQUIREMENTS.

DURING CONSTRUCTION PROJECT UPON COMPLETION OF PROJECT

B C D

A

02.12

STERILE STORAGE

L108

IT

L106

STORAGE

L104

ELECTRICAL

L101

BREAK DOWN

L102

CORR

L103

SUPPLY OFFICE

L105

COPY ROOM

L107

TOILET

L110

TOILET

L111

STERILE STORAGE,

OVERFLOW

L112

HAC

L113

ELECTRICAL

E-102

IT

T-100

MECHANICAL ROOM

M1-3

NITROUS OXIDE

STOR

M1-4

SUPPLY TECH

OFFICE

L115

EMS PRIMARY

L116

SPS RECEIVING

BREAKDOWN

L114

SPECIAL SYSTEMS

DATA ROOM

CAT SCAN EXAM

CAT SCAN CONTROL

CAT SCAN

BREAKROOM

STORAGE

TOILET

OPERATIONS

ARMORY OFFICE

DISPATCH

CABLE TV DATA

ROOM

CORR

DINING

SERVICE ELEV

SERVICE ELEV

ELEV EQUIP

HOLDING

ELEC SW ROOM

OFFICEOFFICE

CORR

OFFICE

CONF RM

STORAGE

IV ANTE RM & CLEAN

STOR

IV ADMIXTURE

STAIRWELL

STERILE FLUIDS

STOR

STOR. PROSTHETIC &

MED

DRUG RECEIVING

SERVICE ELEV

LOBBY

COVERED DOCK

EMPTY CYLINDER

MEDICAL GAS

STORAGE RM

FULL CYLINDER

MEDICAL GAS

STORAGE RM

DIRTY LINEN CART

HOLDING

SUPPLY TECH

SUPERVISOR

L115A

E

CORRIDOR

L109

INDICATES AREA IN SCOPE

OF WORK

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

U.S. Department of Veterans Affairs

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

VA FORM 08 - 6231

A

FULLY SPRINKLERED

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

PARTITION GRAPHICS

NORTH LEGEND

PLAN

NORTH

TRUE

NORTH

EXISTING PARTITION /

BARRIER - WALL TO REMAIN

EXISTING PARTITION /

BARRIER - WALL TO BE

REMOVED

NEW PARTITION / BARRIER - WALL

PARTITION LEGEND

NO RATING

SMOKE RESISTIVE PARTITION - NON RATED

1 HOUR FIRE BARRIER

1 HOUR FIRE/SMOKE BARRIER

2 HOUR FIRE BARRIER

2 HOUR FIRE/ SMOKE BARRIER

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28277

704-814-1346

CONSULTING STRUCTURAL ENGINEERS

POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

FIRST FLOOR - FFE: 0'-0"

KEY PLAN

COPYRIGHT © 2024

WWW.HARRELLDG.COM

21 JUNE 2024

564-24-104

FAYETTEVILLE VA MEDICAL CENTER

HDG PROJECT: 19022

CONSTRUCTION

DOCUMENTS SUBMISSION

RENOVATE SPACE FOR LOGISTICS

(B-1)

AREA OF WORK

A u to d e s k D o c s /1

F a y e tt e v ill e I D

IQ

P ro je c t

N o

-1

-4

R e n o v a ti o n o f S

P S

/1

A R

C H

R

.r v t

/1

/2

:3

:1

P

M

GC102-A

AuthorChecker

FIRST FLOOR - ICRA PLAN

3/32" = 1'-0" F5

FIRST FLOOR - ICRA PLAN

CLASS IV

CLASS IV

GENERAL SHEET NOTES

SYMBOL LEGEND

- SHEET KEYNOTES

02.12 ICRA BARRIER TO BE INSTALLED PRIOR TO START OF

CONSTRUCTION PERIOD WORK ACTIVITIES. BARRIER TO BE

REMOVED UPON COMPLETING CONSTRUCTION PERIOD WORK

ACTIVITIES. EXISTING CEILING & FLOOR TO BE REPAIRED

FOLLOWING REMOVAL OF BARRIER. BARRIER INCLUDES PAINTED

TEMPORARY WALLS, DOOR, AND LOCKING HARDWARE.

COORDINATE KEYING WITH VA-COR.

8'0 16' 32'

*DEDUCT ALTERNATE 4: KEEP FUNCTIONALITY OF

DOUBLE-SIDED ELEVATOR DOORS THAT OPEN

INTO EMS PRIMARY STORAGE L116. REMOVE EAST

FURRING WALL A4R IN EMS PRIMARY L116.

Revision Number Revisions: Date:

1 AMENDMENT 02 07/11/2024

- 597

EXIT

PASSAGEWAY

C-L021

SERVICE

VESTIBULE

C-L022

DN

C10

B C D

A

SLAB ON GRADE

A4

09.17

09.1609.1509.14

26.01 26.0209.19

PIPE TRENCH

P

IP

E T

R E

N C

H

A R

E A

W A

Y

SLAB ON GRADE

PIPE TRENCH

P

IP

E T

R E

N C

H

A R

E A

W A

Y

PIPE TRENCH

P

IP

E T

R E

N C

H

A R

E A

W A

Y

CANTEEN

STORAGE

CANTEEN

STORAGE

CANTEEN

STORAGE

CANTEEN

OFFICE

CANTEEN

OFFICE

GIFT SHOP

WOMEN'S

LOUNGE

WOMEN'S

TOILETWOMEN'S

LOCKER

MEN'S

LOCKER

MEN'S

LOUNGE

MEN'S

TOILET

VENDING ROOM

OFFICE STOR

ELECT

CLO.

STAIR 9 OFFICE OFFICE OFFICE OFFICE OFFICE

CORRIDOR

ELEV.

ELEV.

STAIR 8

DRESS

RM.

IP/STAFF

CLOTHING

RM

CLEAN

UNIFORM

STORAGE

FIRE ALARM

PIPE

CHASE

ELECT. DIST.

REFRIGERATION

AUTOPSY

ROOM

ENTRY

SHOWER

SERVICE

VESTIBULE

E

2' - 0"

SERVICE ELEVATOR

LOBBY

1-L051

U.S. Department of Veterans Affairs

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

VA FORM 08 - 6231

A

FULLY SPRINKLERED

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

PARTITION GRAPHICS

NORTH LEGEND

PLAN

NORTH

TRUE

NORTH

EXISTING PARTITION /

BARRIER - WALL TO REMAIN

EXISTING PARTITION /

BARRIER - WALL TO BE

REMOVED

NEW PARTITION / BARRIER - WALL

PARTITION LEGEND

NO RATING

SMOKE RESISTIVE PARTITION - NON RATED

1 HOUR FIRE BARRIER

1 HOUR FIRE/SMOKE BARRIER

2 HOUR FIRE BARRIER

2 HOUR FIRE/ SMOKE BARRIER

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28277

704-814-1346

CONSULTING STRUCTURAL ENGINEERS

POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

FIRST FLOOR - FFE: 0'-0"

COPYRIGHT © 2024

WWW.HARRELLDG.COM

21 JUNE 2024

564-24-104

FAYETTEVILLE VA MEDICAL CENTER

HDG PROJECT: 19022

CONSTRUCTION

DOCUMENTS SUBMISSION

RENOVATE SPACE FOR LOGISTICS

(B-1)

A u to d e s k D o c s /1

F a y e tt e v ill e I D

IQ

P ro je c t

N o

-1

-4

R e n o v a ti o n o f S

P S

/1

A R

C H

R

.r v t

/1

/2

:1

:0

P

M

AE101-A

AuthorJC

BASEMENT FLOOR -

CONSTRUCTION PLAN

GENERAL SHEET NOTES

- SHEET KEYNOTES

A. REFER TO GI501-A FOR PARTITION TYPES AND AE511-A FOR HEAD OF

WALL CONSTRUCTION.

B. REFER TO LIFE SAFETY DRAWINGS FOR PROJECT-WIDE LIFE SAFETY

SCOPE OF RATED WALLS, BARRIERS, SMOKE RESISTANT

PARTITIONS, SUITE DESIGNATIONS, EGRESS, AND EXIT DISCHARGE

INFORMATION.

C. REFER TO QH101 FOR EQUIPMENT NOT SHOWN ON THIS PLAN.

D. DIMENSIONS ARE TO FINISH FACE OF WALL OR SOFFIT AND TO

COLUMN CENTER LINE UNLESS OTHERWISE NOTED.

E. PROVIDE 3" GROMMETS 48" O.C. IN ALL COUNTERTOPS ABOVE OPEN

KNEE SPACE. CENTER ON OUTLETS BELOW.

F. PARTITION TYPES, AS NOTED BY SYMBOL, CONTINUE BETWEEN

ROOM/SPACE CORNERS OR ANY INTERSECTING PARTITION.

G. DIFFERING PARTITION TYPES SHALL ALIGN SO THAT WALL PLANES

CONTINUE UNBROKEN WITHIN/ACROSS ROOMS AND/OR SPACES.

H. REFER TO AE600-A FOR DOOR SCHEDULE.

I. DISTANCE FROM HINGE SIDE OF DOOR TO INTERSECTING STUD

WALL SHALL BE 4" UNLESS NOTED OR DETAILED OTHERWISE

(MEASURED FROM OUTSIDE OF FRAME.)

J. CONTRACTOR SHALL VERIFY ALL DIMENSIONS NOTED AS "CLR",

"CLEAR", OR "MIN." DIMENSIONS NOTED AS "HOLD" ARE CRITICAL TO

COORDINATE OTHER WORK (E.G. CEILING GRIDS, LIGHTING,

FINISHES, ETC.)

K. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO INITIATING

CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO

ARCHITECT PRIOR TO COMMENCING WORK.

L. CONTRACTOR SHALL PROVIDE ALL BLOCKING REQUIRED TO

ANCHOR ALL WALL AND CEILING MOUNTED ITEMS.

M. FIRE STOPPING SYSTEMS - REFER TO SPECIFICATIONS SECTION 07

84 00 FOR INFORMATION REGARDING PENETRATIONS OF ALL RATED

ASSEMBLIES (BOTH SINGLE AND DOUBLE MEMBRANE

PENETRATIONS), INCLUDING BUT NOT LIMITED TO: PENETRATIONS

FROM DUCTWORK, CONDUIT, PIPING, SUPPORT FOR WALL MOUNTED

EQUIPMENT, CABINETS, AND COUNTERTOPS.

N. ALL NEW PARTITIONS TO BE TYPE C4 UNLESS OTHERWISE NOTED.

1/8" = 1'-0" F5

BASEMENT FLOOR PLAN - 1

4'0 8' 16'

09.14 PAINT NEW FURRING WALLS TO MATCH EXISTING.

09.15 INSTALL NEW STAINLESS STEEL WALL PROTECTION AT 48

INCHES AFF ON NEW FURRING WALLS.

09.16 ON NEW FURRING WALLS, INSTALL NEW 4-INCH BEIGE

RUBBER BASE TO MATCH EXISTING.

09.17 INSTALL NEW WALL ACT WALL MOULDING ALONG NEW

FURRING WALL. REUSE EXISTING TEES AND REPLACE

REMOVED CEILING TILES WITH NEW.

09.19 PAINT STRUCTURE.

26.01 PROTECT EXISTING SWITCHES ON WALL DURING

CONSTRUCTION

26.02 RELOCATE EXIT SIGN TO THIS WALL, REFER TO ELECTRICAL

DRAWINGS.

Revision Number Revisions: Date:

1 AMENDMENT 02 07/11/2024

C R

P P

C R

PP

KP

CR

PP

C R

PP

P P

C R

PP

PP

F .E

.C

F .E

.C

F.E.C.

F.E.C.

F.E.C.

F.E.C.

F .E

.C

F.E.C.

YELLOW.

ISOMETRIC

8" X 8" X 1/2" STL. PLATE

W/ (4) 5/8" Ø X 4" EXP.

ANCHORS - GALV.

1/4" NEOPRENE PAD

SEALANT ALL AROUND

FILLET, TYP.

1/2

4"Ø GALV. STL. PIPE,

SET PLUMB, FILLED W/

CONC. PAINT TRAFFIC

4"

3'

B C D

A

C4T

C6T

C8T

A4R

C4T

102A

108B

102B

108A

21' - 5" 13' - 4"

CLEAR

8' - 0"

A4

37' - 4" 3' - 8" CLEAR

8' - 9"

32' - 7 1/2"

AE201-AD4

11' - 1"

32' - 6 1/2"

ALIGN

WALLS

A4

A0A0

A4 A4

E3

AE300-A

E3

AE301-A

C4S

C4S

C4T

A4

C4T

C4T

C4S

IT

L106

ELECTRICAL

L101

BREAK DOWN

L102

TOILET

L110

TOILET

L111

STERILE STORAGE,

OVERFLOW

L112

HAC

L113

IT

T-100

MECHANICAL ROOM

M1-3

NITROUS OXIDE

STOR

M1-4

SUPPLY TECH

OFFICE

L115

EMS PRIMARY

L116

SPS RECEIVING

BREAKDOWN

L114

STERILE STORAGE

L108

STORAGE

L104

SUPPLY OFFICE

L105

ELECTRICAL

E-102

CORR

L103

COPY ROOM

L107

A00

A4

A00

C4T

C4S

A0

A00

A00

A00

A00

A00

C4T

AE201-A

A8

A00A00

A00A00

A00

A00

/2

/2

/2

GI501-A

B3

AE201-A

A1

/2

AE201-A

E1

09.14

1' - 5"

/2

" EQ EQ

A4

A4R

A00

C4Z

09.15

A4

A4

A0A0

A00

A00

A00A00

A00A00A00

A00

A4R 14.09

14.09

A4

S1R

A00A00

A00A00A00

3' - 4"

A1

AE102-A

A1

AE102-A

07.31

08.05

C1

AE102-A

03.04

67' - 6 1/2"

115A

/2

SUPPLY TECH

SUPERVISOR

L115A

A00

A4

A00

2' - 5 1/2" 8' - 8 1/2"10' - 2"

112A

A3

AE201-A

A6

/2

EQ 4' - 0" EQ

C4S

E

7' - 4"

E Q

E Q

6' - 11"

C4S

03.06

C4Z

W-1

D1

AE102-A

DIRTY LINEN CART

HOLDING

1-1264C

FULL CYLINDER

MEDICAL GAS

STORAGE RM

S-3

SERVICE ELEV

C233

SERVICE ELEV

C232

SERVICE ELEV

LOBBY

C231

ELEV EQUIP

C234

ELEC SW ROOM

C215

SPECIAL SYSTEMS

DATA ROOM

CAT SCAN EXAM

CAT SCAN CONTROL

149A

CAT SCAN

BREAKROOM

STORAGE

TOILET

HOLDING

OPERATIONS

ARMORY OFFICE

DISPATCH

CABLE TV DATA

ROOM

DRUG RECEIVING

C230

STOR. PROSTHETIC &

MED

C229

STERILE FLUIDS

STOR

C228

IV ANTE RM & CLEAN

STOR

C225

IV ADMIXTURE

C226

STAIRWELL

C227

OFFICE

C217 OFFICE

C216

CORR

C218

OFFICE

C220

CONF RM

C221 STORAGE

C222

DINING

CORRIDOR

L109

4' - 5"

EXISTING WALL

DUCT - SEE

MECHANICAL

DRAWINGS

STEEL ANGLE AND PLATE -

SEE STRUCTURAL

DRAWINGS (ALL-WELDED

CONSTRUCTION). PRIME

AND PAINT.

SEALANT, CONTINUOUS

STEEL ANGLE - SEE

SPEC SECTION 05 50 00

(ALL-WELDED

CONSTRUCTION), PRIME

AND PAINT.

BACKER ROD

AND SEALANT

BACKER ROD AND SEALANTPOWDER-COATED

STEEL DUCT RING

AT EACH DUCT

PENETRATION, SEE

MECHANICAL

DRAWINGS

EXISTING 2HR FIRE RATED MONOLITHIC MASONRY WALL

16GA MIN RETAINING

ANGLE SIZED TO LAP

DUCT A MIN 2" AND LAP

WALL MIN 1"

MINERAL WOOL PACKING

MATERIAL.

MIN. 5/8" FILL MATERIAL

AND MIN 1/4" DIA BEAD OF

SEALANT

36" x 30" MAX x 24 GA MIN

GALV STEEL DUCT.

INSULATION AND

DAMPERS WO

2-HR UL W-L-7008

FIRST FLOOR

0' - 0"

/2

ENCLOSURE SIDELOADING DOCK/EXTERIOR

2" EIFS

DRAINAGE MAT

5/8" GLASS FIBER REINFORCED

GYPSUM BOARD SHEATHING

WEEP SCREED FLASHING

EXISTING LOADING DOCK SLAB

BASIS OF DESIGN: STO THERM RAINSCREEN CLASS PB

SEALANT AND BACKER ROD

6" CFMF

MINERAL WOOL INSULATION

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

U.S. Department of Veterans Affairs

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

VA FORM 08 - 6231

A

FULLY SPRINKLERED

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

PARTITION GRAPHICS

NORTH LEGEND

PLAN

NORTH

TRUE

NORTH

EXISTING PARTITION /

BARRIER - WALL TO REMAIN

EXISTING PARTITION /

BARRIER - WALL TO BE

REMOVED

NEW PARTITION / BARRIER - WALL

PARTITION LEGEND

NO RATING

SMOKE RESISTIVE PARTITION - NON RATED

1 HOUR FIRE BARRIER

1 HOUR FIRE/SMOKE BARRIER

2 HOUR FIRE BARRIER

2 HOUR FIRE/ SMOKE BARRIER

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28277

704-814-1346

CONSULTING STRUCTURAL ENGINEERS

POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

FIRST FLOOR - FFE: 0'-0"

KEY PLAN

COPYRIGHT © 2024

WWW.HARRELLDG.COM

21 JUNE 2024

564-24-104

FAYETTEVILLE VA MEDICAL CENTER

HDG PROJECT: 19022

CONSTRUCTION

DOCUMENTS SUBMISSION

RENOVATE SPACE FOR LOGISTICS

(B-1)

AREA OF WORK

A u to d e s k D o c s /1

F a y e tt e v ill e I D

IQ

P ro je c t

N o

-1

-4

R e n o v a ti o n o f S

P S

/1

A R

C H

R

.r v t

/1

/2

:0

:3

P

M

AE102-A

GO/MSJC

FIRST FLOOR - CONSTRUCTION

PLAN

1/8" = 1'-0" F4

FIRST FLOOR - CONSTRUCTION PLAN

GENERAL SHEET NOTES

- SHEET KEYNOTES

A. REFER TO GI501-A FOR PARTITION TYPES AND AE511-A FOR HEAD OF

WALL CONSTRUCTION.

B. REFER TO LIFE SAFETY DRAWINGS FOR PROJECT-WIDE LIFE SAFETY

SCOPE OF RATED WALLS, BARRIERS, SMOKE RESISTANT

PARTITIONS, SUITE DESIGNATIONS, EGRESS, AND EXIT DISCHARGE

INFORMATION.

C. REFER TO QH101-A FOR EQUIPMENT NOT SHOWN ON THIS PLAN.

D. DIMENSIONS ARE TO FINISH FACE OF WALL OR SOFFITT AND TO

COLUMN CENTER LINE UNLESS OTHERWISE NOTED.

E. PROVIDE 3" GROMMETS 48" O.C. IN ALL COUNTERTOPS ABOVE OPEN

KNEE SPACE. CENTER ON OUTLETS BELOW.

F. PARTITION TYPES, AS NOTED BY SYMBOL, CONTINUE BETWEEN

ROOM/SPACE CORNERS OR ANY INTERSECTING PARTITION.

G. DIFFERING PARTITION TYPES SHALL ALIGN SO THAT WALL PLANES

CONTINUE UNBROKEN WITHIN/ACROSS ROOMS AND/OR SPACES.

H. REFER TO AE600-A FOR DOOR SCHEDULE.

I. DISTANCE FROM HINGE SIDE OF DOOR TO INTERSECTING STUD

WALL SHALL BE 4" UNLESS NOTED OR DETAILED OTHERWISE

(MEASURED FROM OUTSIDE OF FRAME.)

J. CONTRACTOR SHALL VERIFY ALL DIMENSIONS NOTED AS "CLR",

"CLEAR", OR "MIN." DIMENSIONS NOTED AS "HOLD" ARE CRITICAL TO

COORDINATE OTHER WORK (E.G. CEILING GRIDS, LIGHTING,

FINISHES, ETC.)

K. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO INITIATING

CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO

ARCHITECT PRIOR TO COMMENCING WORK.

L. CONTRACTOR SHALL PROVIDE ALL BLOCKING REQUIRED TO

ANCHOR ALL WALL AND CEILING MOUNTED ITEMS.

M. FIRE STOPPING SYSTEMS - REFER TO SPECIFICATIONS SECTION 07

84 00 FOR INFORMATION REGARDING PENETRATIONS OF ALL RATED

ASSEMBLIES (BOTH SINGLE AND DOUBLE MEMBRANE

PENETRATIONS), INCLUDING BUT NOT LIMITED TO: PENETRATIONS

FROM DUCTWORK, CONDUIT, PIPING, SUPPORT FOR WALL MOUNTED

EQUIPMENT, CABINETS, AND COUNTERTOPS.

N. ALL PARTITIONS TO BE TYPE C4 UNLESS OTHERWISE NOTED.

4'0 8' 16'

3" = 1'-0" A1

SECTION -MECHANICAL

PENETRATION THRU EXISTING

EXTERIOR WALL

03.04 CONCRETE BOLLARD (TYP.) SEE DETAIL F1/AE102-A.

03.06 PAD DIMENSIONS ARE FOR BASIS OF DESIGN UNIT. CONTRACTOR

MUST ALTER PAD DIMENSIONS PER B3/GI501-A TO CONFORM TO

APPROVED UNIT.

07.31 2" THICK RIGID INSULATION WITH EIFS OVER 5/8" GYPSUM BOARD

SHEATHING AND 6" CFMF.

08.05 24" x 24" ACCESS PANEL.

09.14 PAINT NEW FURRING WALLS TO MATCH EXISTING.

09.15 INSTALL NEW STAINLESS STEEL WALL PROTECTION AT 48

INCHES AFF ON NEW FURRING WALLS.

14.09 DEACTIVATE ELEVATORS DOORS. DISCONNECT BUTTON

OPERATION AND DOME LIGHT AT THE ELEVATOR CONTROLLER.

REMOVE WALL DEVICES.

3" = 1'-0" C1

MECHANICAL PENETRATION THRU 2HR RATED EXTERIOR WALL

0 9"6"3"

0 9"6"3"

2'1'0 1/2'1" = 1'-0" F1

EXTERIOR STEEL PIPE BOLLARD DETAIL

*DEDUCT ALTERNATE 3: REMOVE

EIFS/CFMF FROM DUCT ENCLOSURE.

USE EXTERIOR DUCT JACKETING

INSTEAD OF EIFS/CFMF. KEEP BOLLARDS.

*DEDUCT ALTERNATE 4: KEEP FUNCTIONALITY OF

DOUBLE-SIDED ELEVATOR DOORS THAT OPEN

INTO EMS PRIMARY STORAGE L116. REMOVE EAST

FURRING WALL A4R IN EMS PRIMARY L116.

3" = 1'-0" D1

CFMF EIFS DUCT ENCLOSURE

Revision Number Revisions: Date:

1 AMENDMENT 02 07/11/2024

0 9"6"3"

F

F

F

F

F

OS

F S S

S

S

S

S

F

F

S

OS

OS

OS

OS

W A

P O

S

S

B C D

A.F.F.

AT

8' - 0"

A.F.F.

AT

8' - 0"

A.F.F.

AT

8' - 0"

A

A.F.F.

AT

8' - 0"

A.F.F.

AT

8' - 0"

A.F.F.

AT

9' - 0"

A.F.F.

AT

9' - 0"

A.F.F.

AT

8' - 0"

A.F.F.

AT

8' - 0"

STERILE STORAGE

L108

IT

L106

STORAGE

L104

ELECTRICAL

L101

BREAK DOWN

L102

SUPPLY OFFICE

L105

TOILET

L110

TOILET

L111

STERILE STORAGE,

OVERFLOW

L112

HAC

L113

ELECTRICAL

E-102

MECHANICAL ROOM

M1-3

NITROUS OXIDE

STOR

M1-4

SUPPLY TECH

OFFICE

L115

EMS PRIMARY

L116

SPS RECEIVING

BREAKDOWN

L114

COPY ROOM

L107

CORR

L103

09.13

09.17

9"

8" 8"

A.F.F.

AT

8' - 0"

A.F.F.

GWB

8' - 0"

E Q

E Q

ALIGN

SOFFIT/WALL

6 1/2"

09.19

A.F.F.

GWB

8' - 0"

-SP

SUPPLY TECH

SUPERVISOR

L115A

A.F.F.

GWB

8' - 0"

E

7 1/2"

7' - 5"

9"

/2

9"

E Q

E Q

7 1/2"

A.F.F.

12' - 0"

SPECIAL SYSTEMS

DATA ROOM

CAT SCAN EXAM

CAT SCAN CONTROL

149A

CAT SCAN

BREAKROOM

STORAGE

TOILET

OPERATIONS

ARMORY OFFICE

DISPATCH

CABLE TV DATA

ROOM

ELEC SW ROOM

E103

OFFICE

118B

OFFICE

118A

CORR

C104

OFFICE

118C

CONF RM

STORAGE

120A

DINING

IV ANTE RM & CLEAN

STOR

1-1223

INTRAVENOUS

ADMIXTURE

1-1224

STAIRWELL

S102

STERILE FLUIDS &

ADMIXTURE STOR

1-1227

STOR. PROSTHETIC &

MED SUPPLIES

1-1228

DRUG RECEIVING

1-1229

SERVICE ELEVATOR

LOBBY

C120

SERVICE ELEVATOR

L05

SERVICE ELEVATOR

L06

ELEV EQUIP

HOLDING

CORR

C110

ELEVATOR LOBBY

COVERED DOCK

1-1264

EMPTY CYLINDER

MEDICAL GAS

STORAGE RM

1-1264B

FULL CYLINDER

MEDICAL GAS

STORAGE RM

1-1264B

DIRTY LINEN CART

HOLDING

1-1264C

ELEVATOR

ELEVATOR

4' LINEAR PENDANT DIRECT/

INDIRECT LED LIGHT

FIXTURE

SYMBOLS - RCP

SPEAKER - COMMUNICATIONS

CEILING MOUNTED -

WIRELESS ACCESS POINT

SUPPLY DIFFUSER

RETURN GRILLE

OCCUPANCY SENSOR

2' x 4' TROFFER LIGHT

2' x 4' TROFFER LIGHT

CRITICAL

2' x 4' TROFFER LIGHT

LIFE SAFETY

EXHAUST GRILLE

CHASE SYMBOL

CEILING EXIT SIGN - VARIOUS DIRECTIONAL

AND NON-DIRECTIONAL CONFIGURATIONS

CEILING MOUNTED FIRE ALARM SPEAKER DEVICE

FIRE ALARM SMOKE DETECTOR

FIRE ALARM HEAT DETECTOR

FIRE ALARM SYSTEM CEILING MONTED SMOKE

DETECTOR FOR ELEVATOR RECALL

F

E

CEILING MOUNTED COMBINATION FIRE ALARM

SPEAKER/STROBE DEVICE

F

STRUC EXPOSED TO STRUCTURE

R FIRE ALARM CONNECTION

RELAY

CEILING MOUNTED CAMERA

ACT CEILING SYSTEM

GWB CEILING

CEILING ACCESS PANEL

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

U.S. Department of Veterans Affairs

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

VA FORM 08 - 6231

A

FULLY SPRINKLERED

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

PARTITION GRAPHICS

NORTH LEGEND

PLAN

NORTH

TRUE

NORTH

EXISTING PARTITION /

BARRIER - WALL TO REMAIN

EXISTING PARTITION /

BARRIER - WALL TO BE

REMOVED

NEW PARTITION / BARRIER - WALL

PARTITION LEGEND

NO RATING

SMOKE RESISTIVE PARTITION - NON RATED

1 HOUR FIRE BARRIER

1 HOUR FIRE/SMOKE BARRIER

2 HOUR FIRE BARRIER

2 HOUR FIRE/ SMOKE BARRIER

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28277

704-814-1346

CONSULTING STRUCTURAL ENGINEERS

POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

FIRST FLOOR - FFE: 0'-0"

KEY PLAN

COPYRIGHT © 2024

WWW.HARRELLDG.COM

21 JUNE 2024

564-24-104

FAYETTEVILLE VA MEDICAL CENTER

HDG PROJECT: 19022

CONSTRUCTION

DOCUMENTS SUBMISSION

RENOVATE SPACE FOR LOGISTICS

(B-1)

AREA OF WORK

A u to d e s k D o c s /1

F a y e tt e v ill e I D

IQ

P ro je c t

N o

-1

-4

R e n o v a ti o n o f S

P S

/1

A R

C H

R

.r v t

/1

/2

:0

:1

P

M

AE111-A

GO/MSJC

FIRST FLOOR - REFLECTED CEILING

PLAN

A. CEILING HEIGHTS TO BE 8'-0" UON.

B. DIMENSIONS ARE TO FINISH FACE OF WALL OR SOFFIT UON.

C. RATED WALLS: ARE INDICATED IN PLAN AND REFLECTED CEILING

PLAN WITH GRAPHIC DENOTING HOURLY RATING AND/OR

RESISTANT TO PASSAGE OF SMOKE. REFER TO PARTITION TAGS

ON FLOOR PLANS AND PARTITION SCHEDULE SHEET FOR MORE

INFORMATION.

D. GYPSUM BOARD SOFFITS: HEIGHT AFF TO MATCH ADJACENT

CEILING OR TOP OF CASEWORK UON ON REFLECTED CEILING

PLAN.

E. CEILING MATERIAL TRANSITIONS, FLUSH AND NON-FLUSH

CONDITIONS: REFER TO STANDARD DETAILS.

F. CEILING FINISHES/MATERIALS ARE NOTED ON FINISH SCHEDULE.

G. ACOUSTIC TILE CEILINGS TO BE CENTERED IN BOTH DIRECTIONS IN

ROOM TYP, UON OR DIMENSIONED OTHERWISE. IF DIMENSION IS

PROVIDED IN ONE DIRECTION ONLY, ASSUME GRID IS CENTERED IN

OTHER DIRECTION.

H. CUT TILES SHALL BE NO SMALLER THAN 4 INCHES IN ANY

DIRECTION. CEILING FINISHES / MATERIALS NOTED ON TYPICALS

FINISH SCHEDULE.

I. PLASTIC LAMINATE (P-LAM) CLOSURE PANELS (IN LIEU OF GYPSUM

BOARD SOFFITS) OVER CASEWORK - SEE INTERIOR ELEVATIONS.

J. CENTER LIGHT FIXTURE AND OTHER CEILING DEVICES WITHIN

ACOUSTIC TILE UON. IF ONLY DIMENSIONED IN ONE DIRECTION,

ASSUME DEVICE IS CENTERED IN THE OTHER DIRECTION.

K. DIMENSIONS TO CENTERLINE OF LIGHT FIXTURE UON.

L. EXIT SIGNAGE/LIGHTING SHOWN ON ELECTRICAL LIGHTING

DRAWINGS.

M. ALL CORRIDOR HEADERS ARE 7'-8" AFF, UNLESS NOTED

OTHERWISE.

1/8" = 1'-0" F4

FIRST FLOOR - REFLECTED CEILING PLAN

GENERAL SHEET NOTES

- SHEET KEYNOTES

4'0 8' 16'

09.13 PORTION OF ACOUSTICAL CEILING TILE SYSTEM TO BE

COMPLETED AT CONCLUSION OF CONSTRUCTION PERIOD.

ACOUSTICAL CEILING TILE SYSTEM, LIGHTING, AND CEILING

DEVICES TO BE INSTALLED ONCE TEMPORARY CONSTRUCTION

BARRIER HAS BEEN REMOVED.

09.17 INSTALL NEW WALL ACT WALL MOULDING ALONG NEW FURRING

WALL. REUSE EXISTING TEES AND REPLACE REMOVED CEILING

TILES WITH NEW.

09.19 PAINT STRUCTURE.

*DEDUCT ALTERNATE 3: REMOVE

EIFS/CFMF FROM DUCT ENCLOSURE.

USE EXTERIOR DUCT JACKETING

INSTEAD OF EIFS/CFMF. KEEP BOLLARDS.

*DEDUCT ALTERNATE 4: KEEP FUNCTIONALITY OF

DOUBLE-SIDED ELEVATOR DOORS THAT OPEN

INTO EMS PRIMARY STORAGE L116. REMOVE EAST

FURRING WALL A4R IN EMS PRIMARY L116.

Revision Number Revisions: Date:

1 AMENDMENT 02 07/11/2024

1 1

.C

F.E.C.

FIRST FLOOR

0' - 0"

A5195

A5090

PWT-1

FIRST FLOOR

CEILING

8' - 0"

A5109.3

1/4" VERTICAL ALUMINUM

EXPANSION STRIPS AT ALL

CORNERS, TYPICAL

1' - 7" 1' - 7"

EQ FULL TILES EQ

FIRST FLOOR

0' - 0"

A5082

A5075

A5109.2

A1066

PWT-1

FIRST FLOOR

CEILING

8' - 0"

1/4" VERTICAL ALUMINUM

EXPANSION STRIPS AT ALL

CORNERS, TYPICAL

EQ EQ

1' - 6" 1' - 0 1/2" 3 1/2"

TYPICAL

FULL TILES

FIRST FLOOR

0' - 0"

FIRE ALARM DEVICE: SEE ELECTRICAL

PWT-1

FIRST FLOOR

CEILING

8' - 0"

1/4" VERTICAL ALUMINUM

EXPANSION STRIPS AT ALL

CORNERS, TYPICAL

A5075

EQ FULL TILES EQ

FIRST FLOOR

0' - 0"

C4

AE510-A

TYP

B4

AE510-A

TYP

E3

AE301-A

113 108B108A111112

CARD READER: SEE ELECTRICAL

FIRST FLOOR

CEILING

8' - 0"

WP-1

WP-1

WP-1WP-1

WP-1

P-1 P-1 GC-SGC-SP-1 GC-SGC-SGC-SP-1

D C A

FIRST FLOOR

0' - 0"

M1802

M2055

FIRST FLOOR

CEILING

8' - 0"

WP-2 WP-2

M1801

WP-2

GC-S GC-S

P-1 P-1P-1

EQ EQ

6"6"

FIRST FLOOR

0' - 0"

PWT-1

A5080

A5075

FIRST FLOOR

CEILING

8' - 0"

1' - 3" 1' - 1"

EQ EQ

P-1

EQ

P4700 MOP SINK,

REFER TO PULMBING

DRAWINGS

1/4" VERTICAL ALUMINUM

EXPANSION STRIPS AT ALL

CORNERS, TYPICAL

FIRST FLOOR

0' - 0"

PWT-1

FIRST FLOOR

CEILING

8' - 0"

1' - 8"

EQ EQ

P-1

P4700 MOP SINK,

REFER TO PULMBING

DRAWINGS

P2000 EYE WASH,

REFER TO PULMBING

DRAWINGS

1' - 0"

1/4" VERTICAL ALUMINUM

EXPANSION STRIPS AT ALL

CORNERS, TYPICAL

FIRST FLOOR

0' - 0"

PWT-1

A5135

SECURITY CAMERA: SEE

ELECTRICAL FIRST FLOOR

CEILING

8' - 0"

A5160

2' - 8" 1' - 0"

P-1

1/4" VERTICAL ALUMINUM

EXPANSION STRIPS AT ALL

CORNERS, TYPICAL

C

AE201-AE8

E6

E3

7' - 5 1/2"

C4T-T2

C4S-T2

A4-T2A4-T2

C4T-T2

C4S-T2

FLUSH

AE201-A

E6

E3

A4-T2

A5075A5082

C4T-T2

C4T-T2

1' - 3 1/2"

1' - 6"

TOILET

L111

TOILET

L110

A5109.2

A5090

A5109.3

A1066

E8

E6

E6 (TILE SIMILAR)

E6 (TILE SIMILAR)

C

AE201-A C4

C6

C8

7' - 3"

C4R-T1C4R-T1

C6T-T1

A5080

A5075

HAC

L113

A4-T1

A4-T1

C4S-T1

1' - 7 1/2"

6"5 1/2"

C6 (TILE SIMILAR)

FIRST FLOOR

0' - 0"

FIRST FLOOR

CEILING

8' - 0"

A1

AE510-A

E0042

M1801

A1015

P-1

W-1

4' - 0"

HOLLOW METAL FRAME

U.S. Department of Veterans Affairs

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

VA FORM 08 - 6231

A

FULLY SPRINKLERED

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28277

704-814-1346

CONSULTING STRUCTURAL ENGINEERS

POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2024

WWW.HARRELLDG.COM

21 JUNE 2024

564-24-104

FAYETTEVILLE VA MEDICAL CENTER

HDG PROJECT: 19022

CONSTRUCTION

DOCUMENTS SUBMISSION

RENOVATE SPACE FOR LOGISTICS

(B-1)

A u to d e s k D o c s /1

F a y e tt e v ill e I D

IQ

P ro je c t

N o

-1

-4

R e n o v a ti o n o f S

P S

/1

A R

C H

R

.r v t

/1

/2

:2

:3

P

M

AE201-A

AuthorChecker

INTERIOR ELEVATIONS - FIRST

FLOOR

1/2" = 1'-0" E8

INTERIOR ELEVATION - TOILET (L111) - WEST

1/2" = 1'-0"

E6

INTERIOR ELEVATION - TOILET (L111) - NORTH

1/2" = 1'-0" E3

INTERIOR ELEVATION - TOILET (L111) - EAST

1/2" = 1'-0" D4

INTERIOR ELEVATION - SPS AREA - CORRIDOR (L109)

1'0 2' 4'

1'0 2' 4'1'0 2' 4' 1'0 2' 4'

1/2" = 1'-0" A8

TYPICAL WORK STATION

1'0 2' 4'

1/2" = 1'-0" C4

INTERIOR ELEVATION- HAC (L113) - EAST 1/2" = 1'-0"

C6

INTERIOR ELEVATION- HAC (L113) - SOUTH

1/2" = 1'-0"

C8

INTERIOR ELEVATION- HAC (L113) - WEST

SECURITY CAMERA: SEE ELECTRICAL

1/2" = 1'-0" A1

ENLARGED PLANS - L110/L111

1/2" = 1'-0" E1

ENLARGED PLAN - L113

1/2" = 1'-0" A6

SUPPLY TECH SUPERVISOR

1'0 2' 4'

*DEDUCT ALTERNATE 1: DOWNGRADE

BATHROOM PORCELAIN TILE WALLS

AND FLOORS TO WALL PAINT AND

RESINOUS EPOXY FLOORING.

*DEDUCT ALTERNATE 1:

DOWNGRADE BATHROOM

PORCELAIN TILE WALLS AND

FLOORS TO WALL PAINT AND

RESINOUS EPOXY FLOORING.

1'0 2' 4'

1'0 2' 4'

Revision Number Revisions: Date:

1 AMENDMENT 02 07/11/2024

1'0 2' 4'

1'0 2' 4' 1'0 2' 4'

1 1

.C

F .E

.C

F.E.C.

F.E.C.

F.E.C.

F.E.C.

F.E.C.

F .E

.C

F.E.C.

B C D

A

STERILE STORAGE

L108

IT

L106 STORAGE

L104

ELECTRICAL

L101

BREAK DOWN

L102

SUPPLY OFFICE

L105

TOILET

L110

TOILET

L111

STERILE STORAGE,

OVERFLOW

L112

HAC

L113

ELECTRICAL

E-102

IT

T-100

MECHANICAL ROOM

M1-3

NITROUS OXIDE

STOR

M1-4

SUPPLY TECH

OFFICE

L115

EMS PRIMARY

L116

SPS RECEIVING

BREAKDOWN

L114

WP-1 WP-1

WP-1

WP-1

WP-1

WP-1

COPY ROOM

L107

CG-S

CG-S

CG-S

CG-S

CG-S

CG-S

CG-S

CG-S

CG-S

CG-S

CG-S

CG-S

CG-S

CG-S CG-S

CG-SCG-S

CG-S

CG-S

CG-S

CG-SCG-S

CG-S

CG-S CG-S

CG-S CG-S

CG-S

CG-S

CG-S

CG-S

CG-S

09.18

WP-2

WP-2

WP-2

WP-2

WP-2

WP-2

WP-2

WP-2

WP-2

WP-2

WP-3

WP-3

WP-3

WP-3

WP-2

RES-6APWT-1

RES-6APWT-1

R E

S -6

A R

E S

-3

R E

S

- 6A

C P

T

- 1

R E

S -6

A E

P Y

-1

R E

S -6

A E

P Y

-1

R E

S -6

A E

X

IS

T

IN

G

LV

T

EXISTING

LVTRES-6A

CG-S

CG-S

SUPPLY TECH

SUPERVISOR

L115A

WP-3

E

RES-6APWT-1

06.07

D

F

A

D

A

F

A

A

F

C

F

D

C

A

DD

A

A

A

A

CG-S

N

I

I

I

I

CORR

L103

CORRIDOR

L109

A

A

TYPE DESCRIPTION

C-1 CONCRETE FLOORING

CG-S CORNER GUARD (STAINLESS STEEL)

CPT-1

RES-3

CARPET TILE

RESINOUS FLOORING

MARK

PWT-1 PORCELAIN TILE FLOORING

RES-6A RESINOUS HEAVY DUTY FLOORING

EPY-1 EPOXY FLOORING

A. REFER TO SHEET AI002-B FOR GENERAL FINISH PLAN NOTES AND

SYMBOLS.

B. ALL CORRIDORS TO RECEIVE WALL PROTECTION WP-1. INSTALL

CAPS AROUND ALL PENETRATIONS.

C. ALL CORRIDORS CORNERS TO RECEIVE CORNER GUARDS.

SPECIAL SYSTEMS

DATA ROOM

CAT SCAN EXAM

CAT SCAN CONTROL

149A

CAT SCAN

BREAKROOM

STORAGE

TOILET

OPERATIONS

ARMORY OFFICE

DISPATCH

CABLE TV DATA

ROOM

ELEC SW ROOM

E103

OFFICE

118B

OFFICE

118A

CORR

C104

OFFICE

118C

CONF RM

STORAGE

120A

DINING

120 IV ANTE RM & CLEAN

STOR

1-1223

INTRAVENOUS

ADMIXTURE

1-1224

STAIRWELL

S102

STERILE FLUIDS &

ADMIXTURE STOR

1-1227

STOR. PROSTHETIC &

MED SUPPLIES

1-1228

DRUG RECEIVING

1-1229

SERVICE ELEVATOR

LOBBY

C120

SERVICE ELEVATOR

L05

SERVICE ELEVATOR

L06

ELEV EQUIP

HOLDING

CORR

C110

ELEVATOR LOBBY

COVERED DOCK

1-1264

EMPTY CYLINDER

MEDICAL GAS

STORAGE RM

1-1264B

FULL CYLINDER

MEDICAL GAS

STORAGE RM

1-1264B

DIRTY LINEN CART

HOLDING

1-1264C

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

HANDICAPPED

PARKING

U.S. Department of Veterans Affairs

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

VA FORM 08 - 6231

A

FULLY SPRINKLERED

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

PARTITION GRAPHICS

NORTH LEGEND

PLAN

NORTH

TRUE

NORTH

EXISTING PARTITION /

BARRIER - WALL TO REMAIN

EXISTING PARTITION /

BARRIER - WALL TO BE

REMOVED

NEW PARTITION / BARRIER - WALL

PARTITION LEGEND

NO RATING

SMOKE RESISTIVE PARTITION - NON RATED

1 HOUR FIRE BARRIER

1 HOUR FIRE/SMOKE BARRIER

2 HOUR FIRE BARRIER

2 HOUR FIRE/ SMOKE BARRIER

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28277

704-814-1346

CONSULTING STRUCTURAL ENGINEERS

POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

FIRST FLOOR - FFE: 0'-0"

KEY PLAN

COPYRIGHT © 2024

WWW.HARRELLDG.COM

21 JUNE 2024

564-24-104

FAYETTEVILLE VA MEDICAL CENTER

HDG PROJECT: 19022

CONSTRUCTION

DOCUMENTS SUBMISSION

RENOVATE SPACE FOR LOGISTICS

(B-1)

AREA OF WORK

A u to d e s k D o c s /1

F a y e tt e v ill e I D

IQ

P ro je c t

N o

-1

-4

R e n o v a ti o n o f S

P S

/1

A R

C H

R

.r v t

/1

/2

:2

:0

P

M

AF601-A

GO/MSJC

FIRST FLOOR FINISH PLAN

1/8" = 1'-0" F4

FIRST FLOOR FINISH PLAN

GENERAL SHEET NOTES

FINISH FLOOR LEGEND

4'0 8' 16'

- SHEET KEYNOTES

06.07 INSTALL PAINTED, 5/8-INCH THICK, 4-FOOT BY 8-FOOT, GRADE A-C

FIRE RETARDANT PLYWOOD ON ALL GYPSUM BOARD WALLS

EXCEPT DOOR WALL AND BELOW WINDOW, PLYWOOD A-SIDE

FACING THE ROOM INTERIOR. DO NOT PAINT OVER PLYWOOD

STAMP. MOUNT BOTTOM OF PLYWOOD 8-INCHES ABOVE

FINISHED FLOOR, LONGEST BOARD LENGTH ORIENTED

VERTICALLY.

09.18 ON NEW FURRING WALLS ON EXISTING LVT FLOORING, INSTALL

NEW 4-INCH BEIGE RUBBER BASE TO MATCH EXISTING.

*DEDUCT ALTERNATE 1:

DOWNGRADE BATHROOM

PORCELAIN TILE WALLS AND

FLOORS TO WALL PAINT AND

RESINOUS EPOXY FLOORING.

Revision Number Revisions: Date:

1 AMENDMENT 02 07/11/2024

U.S. Department of Veterans Affairs

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

VA FORM 08 - 6231

A

FULLY SPRINKLERED

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASE

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28277

704-814-1346

CONSULTING STRUCTURAL ENGINEERS

POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2024

WWW.HARRELLDG.COM

21 JUNE 2024

564-24-104

FAYETTEVILLE VA MEDICAL CENTER

HDG PROJECT: 19022

CONSTRUCTION

DOCUMENTS SUBMISSION

RENOVATE SPACE FOR LOGISTICS

(B-1)

A u to d e s k D o c s /1

F a y e tt e v ill e I D

IQ

P ro je c t

N o

-1

-4

R e n o v a ti o n o f S

P S

/1

A R

C H

R

.r v t

/1

/2

:2

:1

P

M

AF602-A

AuthorChecker

INTERIOR FINISH SCHEDULE AND

SIGNAGE SCHEDULE

INTERIOR FINISH SCHEDULE - A

Room No. Room Name Level Floor Finish

Base Finish

Wall Finish Ceiling Finish

Millwork Horizontal

Millwork Vertical Wall Protection CommentsNorth South East West

FIRST FLOOR

E-102 ELECTRICAL FIRST FLOOR EPY-1 RB-1 P-2 P-2 P-2 P-2 EXISTING --- --- ---

L101 ELECTRICAL FIRST FLOOR EPY-1 RB-1 P-2 P-2 P-2 P-2 EXISTING --- --- ---

L102 BREAK DOWN FIRST FLOOR C-1 RB-1 P-1 P-1 P-1 P-1 AT-1 --- --- WP-3

L103 CORR FIRST FLOOR RES-6A RES-6A P-1 P-1 P-1 P-1 AT-1 --- --- WP-1

L104 STORAGE FIRST FLOOR RES-3 RES-3 P-2 P-2 P-2 P-2 AT-1 --- --- ---

L105 SUPPLY OFFICE FIRST FLOOR CPT-1 RB-1 P-1 P-1 P-1 P-1 AT-1 --- --- ---

L106 IT FIRST FLOOR EPY-1 RB-1 P-1 P-1 P-1 P-1 EXISTING --- --- --- 3/4" PLYWOOD

L107 COPY ROOM FIRST FLOOR CPT-1 RB-1 P-1 P-1 P-1 P-1 AT-1 --- --- ---

L108 STERILE STORAGE FIRST FLOOR RES-6A RES-6A P-1 P-1 P-1 P-1 AT-1 --- --- WP-2

L109 CORRIDOR FIRST FLOOR RES-6A RES-6A P-1 P-1 P-1 P-1 AT-1 --- --- WP-1

L110 TOILET FIRST FLOOR PWT-1 --- PWT-1 PWT-1…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .