36C25624Q1094 - Drawing 1 Civil Engineer and Post Surcharge .pdf

PDF 398 KB Posted

Attached to
R425--629-24-3-639-0495, Water Well Study/Assessment (VA-24-00076371)
Solicitation number
36C25624Q1094
Issued by

About this file

This document appears to be a Request for Quote (RFQ) for a water well study/assessment (Solicitation Number: 36C25624Q1094) issued by the Department of Veterans Affairs, Veterans Integrated Service Network 16. The procurement is set-aside for Service-Disabled Veteran Owned Small Businesses under NAICS code 541330 with a $25.0 million size standard. The associated FSC/PSC code is R425.

The RFQ seeks commercial products and services related to a water well study/assessment. All quotes must be submitted to the Contract Specialist, Keith Mainous, by the deadline of July 30, 2024 at 2:00 pm CST. The solicitation includes an attached RFQ and supporting documents. Questions must be submitted in writing by the July 30, 2024 deadline and will be answered through a solicitation amendment.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

4' CSW

4' CSW

4' CSW

C

S W

C

S W

C

S W

T W

O

S

T O

R Y

W O

O D

H O

U S

E

O N

E

S

T O

R Y

W O

O D

H O

U S

E

T W

O

S

T O

R Y

B R

I C

K

B

U I L

D I N

G

G R

A S

S

G R

A S

S

C O

N C

R E

T E

D R

I V

E

O N

E

S

T O

R Y

B R

I C

K

B

U I L

D I N

G

T W

O

S

T O

R Y

B R

I C

K

B

U I L

D I N

G

W

W

MATCH LINE (SEE SHEET CD102)

FULLY SPRINKLERED

REVISIONS: DATE

02/29/2012

ARCHITECT/ENGINEERS:CONSULTANTS:

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

SLVHCS

REPLACEMENT MEDICAL CENTER

PROJECT

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLE

NEW ORLEANS, LOUISIANA

B

A

D

C

E

VA FORM 08-6231

O N

E

E

I G

H T

I N

C

O

E

F

O

T O

Q

U A

R T

R

O

T T

H R

G

H T

S

O

T O

A L

F

I N

O

T T

H R

Q

U A

R T

E R

S

I N

O

T O

O

T O

D

L

F

I N

C H

O

T O

X

T Y

E

T

CMJ ML

CONSTRUCTION DOCUMENTS 1

123456

F

B

A

D

C

E

F

WP_08

DOCUMENT SET PACKAGE

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD/ TANK CONSULTANT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

629-HS2-401

PROJECT NUMBER BUILDING NUMBER

PROFESSIONAL ENGINEER

A

E

RYAN M. FLANAGAN

C

E

IVI

IN G N E

ST

License. No. 30577

EAT

FO UOL SI I

R

AN

L

GNIIN

CD101

KEY PLAN

PLAN

NORTH

1" = 40'

SCALE:

NOTES

1. GRADING CONTOURS AND ELEVATIONS

REPRESENT THE ELEVATION OF THE SITE ONCE

SITE SURCHARGING ACTIVITIES ARE COMPLETE.

REFERENCE EARLY WORK PACKAGE NO. 1

(EWP_1) - FOR ADDITIONAL INFORMATION.

2. TEMPORARY "EXISTING" DRAINAGE FACILITIES

REPRESENT THE PIPING AND STRUCTURES

INSTALLED WITH EWP_1. LOCATIONS ARE

APPROXIMATE AND SHALL BE FIELD VERIFIED

PRIOR TO CONSTRUCTION.

3. TEMPORARY "EXISTING" DRAINAGE FACILITIES

SHALL BE REMOVED AND DISPOSED OF ONCE

PERMANENT DRAINAGE FACILITIES ARE

INSTALLED OR AS REQUIRED TO CONSTRUCT

PERMANENT SITE UTILITIES AND STRUCTURES.

File details come from the government source that posted it. Updated .