This document is a Request for Information (RFI) issued by the Department of Veterans Affairs Network Contracting Office 16 for the repair of an underground diesel storage tank. The purpose of the RFI is to identify potential sources that possess the capability to furnish and install three mixed metal oxide impressed current cathodic protection system anodes, ensure continuity of structure wires, replace paving and seal wiring cuts, energize and test the system, and provide a post-repair report.
The RFI requests responses from vendors by April 15, 2024, including the vendor's name, contact information, business size, DUNS number, and whether they are a small business, SDVOSB, VOSB, HUBZone, or 8(a) concern with the applicable NAICS code of 811310. Vendors are also requested to provide information on any available government contracts they hold. Small businesses are encouraged to respond to assist the agency in determining the procurement strategy, which may include a set-aside, and to provide estimated market pricing.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Department of Veterans Affairs Network Contracting Office (NCO) 16 Request For Information (RFI)
| SUBJECT* |
| Underground Diesel Storage Tank Repair |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 39216 |
| SOLICITATION NUMBER* |
| 36C25624Q0727 |
| RESPONSE DATE/TIME/ZONE |
| 04-15-2024 09:00 CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| Z2GC |
| NAICS CODE* |
| 811310 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 16 Commercial Acquisition Team – Jackson/Fa 715 S Pear Orchard, Plaza 1 Ridgeland, MS 39157
POINT OF CONTACT*
Lakeisha White lakeisha.white@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| G.V. Sonny Montgomery VAMC |
1500 E Woodrow Wilson
Jackson, MS 39216
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
Sources Sought Notice Sources Sought Notice
DESCRIPTION
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
DISCLAIMER: THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS SYNOPSIS IS NOT A REQUEST FOR QUOTE, PROPOSAL, OR BID. This notice is not a solicitation as defined by FAR 2.101, therefore it shall not be construed as a commitment by the Government to enter into a contract, nor does it restrict the Government to an acquisition approach. All information contained in this Request for Information (RFI) is preliminary as well as subject to amendment and is in no way binding on the Government. Information submitted in response to this notice is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. The Government is requesting that restrictive or proprietary markings not be used in response to this notice. If a solicitation is released, it will be synopsized in the Federal Contract Opportunities website or GSA. It is the responsibility of the interested parties to monitor these sites for additional information pertaining to this RFI.
1. Title: __Underground Diesel Storage Tank Repair ___________________________________
2. Purpose: The purpose of this RFI is to identify potential sources which will aid in defining the procurement strategy (e.g., set-aside, sole source, unrestricted) for a solicitation the VA intends on issuing shortly for the following:
Services needed under this effort are described below:
1. Furnish and install three (3) mixed metal oxide impressed current cathodic protection system anodes. Installation includes all drilling, excavation and saw cutting needed for the installation of anodes and lead wires back to the rectifier.
2. Ensure all structure (negative circuit) wires are in place as needed for continuity and install/repair as needed.
3. Replace the paving removed for the anode boreholes and seal all wiring saw cuts made as part of these repairs with elastomeric sealant.
4. After installation, energize, adjust and test the impressed current system.
5. Properly dispose of all materials and leave jobsite in “broom clean” condition.
6. Conduct all testing and prepare post-repair report to document compliance with the underground storage tank cathodic protection testing requirements.
The anticipated Small Business Administration (SBA) size standard for the North American Industry Classification System (NAICS) code _811310_ is __$12.5M__.
3. Responses Requested: The following questions must be answered in response to this RFI.
Answers that are not provided shall be considered non-responsive to the RFI:
Vendor must attach documentation of this to be viewed by the government to be considered as part of the Market Research and responsiveness to this Sources Sought notice
a. Name of potential Contractor that possess the capability to fulfill this requirement. Contractors shall also provide the following:
Point(s) of contact name: _______________________________________________ Address: ___________________________________________________ Telephone number: ___________________________________________ Email address: _______________________________________________
Company's business size: ________________________________________________ Data Universal Numbering System (DUNS) #: _______________________________
b. Is your company considered a small business concern, SB, SDVOSB, VOSB, HUBZone, or 8A concern, with the requisite ___811310______ NAICS code?
· Please provide proof of qualifications.
c. Is your company available under any Government Wide Agency Contract (GWAC), General Services Administration (GSA) Schedule, Indefinite Delivery Indefinite Quantity (IDIQ), and/or Blanket Purchase Agreement (BPA)?
If so, please identify the contract number for the Government to review as part of this Market Research.
4. Opportunity/Market Pricing: The MEDVAMC is seeking information from potential vendors on their ability to provide the required service. THIS IS A SOURCES SOUGHT REQUEST FOR INFORMATION (RFI) ONLY. Small Business Concerns are encouraged to provide responses to this RFI in order to assist the MEDVAMC in determining potential levels of competition and general market pricing available in the industry. Therefore, vendors are requested to submit estimated market research pricing along with their responses to the above. The estimated pricing will be considered when determining the procurement strategy for the forthcoming solicitation.
5. Instructions and Response Guidelines: Questions regarding this RFI shall be submitted no later than 9:00am (CST), April 15, 2024, via email to lakeisha.white@va.gov.
RFI responses are due by 9:00am (CST), Monday, April 15, 2024; size is limited to 8.5 x 11 inches, 12-point font, with 1-inch margins in Microsoft Word format via email to lakeisha.white@va.gov The subject line shall read: Underground Diesel Storage Tank Repair Sources Sought. NO SOLICITATION EXISTS AT THIS TIME. There is no page limitation on subparagraphs 3(a) - 3(f).
Please provide the information you deem relevant in order to respond to the specific inquiries of the RFI. Information provided will be used solely by MEDVAMC as “Market Research” and will not be released outside of the MEDVAMC Purchasing and Contract Team.
7. Contact Information:
Lakeisha White Lakeisha.white@va.gov
Your response to this notice is greatly appreciated!