36C25623Q0784.docx

DOCX document 173 KB Posted

Attached to
H142--Fire Alarm Testing and Services Federal contract opportunity
Solicitation number
36C25623Q0784
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

36C25623Q0784

PAGE 1 OF

1. REQUISITION NO.

2. CONTRACT NO.

3. AWARD/EFFECTIVE DATE

4. ORDER NO.

5. SOLICITATION NUMBER

6. SOLICITATION ISSUE DATE

a. NAME

b. TELEPHONE NO. (No Collect Calls)

8. OFFER DUE

DATE/LOCAL

TIME

9. ISSUED BY

CODE

10. THIS ACQUISITION IS

UNRESTRICTED OR

SET ASIDE:

% FOR:

SMALL BUSINESS

HUBZONE SMALL

BUSINESS

SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

WOMEN-OWNED SMALL BUSINESS

(WOSB) ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

EDWOSB

8(A)

NAICS:

SIZE STANDARD:

11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

SEE SCHEDULE

12. DISCOUNT TERMS

13a. THIS CONTRACT IS A

RATED ORDER UNDER

DPAS (15 CFR 700)

13b. RATING

14. METHOD OF SOLICITATION

RFQ

IFB

RFP

15. DELIVER TO

CODE

16. ADMINISTERED BY

CODE

17a. CONTRACTOR/OFFEROR

CODE

FACILITY CODE

18a.

PAYMENT WILL BE MADE BY

CODE

TELEPHONE NO.

UEI:

EFT:

PHONE:

FAX:

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN OFFER 18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK BELOW IS CHECKED

SEE

ADDENDUM

19.

20.

21.

22.

23.

24.

ITEM NO.

SCHEDULE OF SUPPLIES/SERVICES

QUANTITY

UNIT

UNIT PRICE

AMOUNT

(Use Reverse and/or Attach Additional Sheets as Necessary)

25. ACCOUNTING AND APPROPRIATION DATA

26.

TOTAL AWARD AMOUNT (For Govt. Use Only) 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED. ADDENDA

ARE

ARE NOT ATTACHED.

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212

-4. FAR 52.212-5 IS ATTACHED. ADDENDA

ARE

ARE NOT ATTACHED

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN _______________

29. AWARD OF CONTRACT: REF. ___________________________________ OFFER

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

DATED ________________________________. YOUR OFFER ON SOLICITATION

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED

SET FORTH HEREIN IS ACCEPTED AS TO ITEMS:

30a. SIGNAT

URE OF OFFEROR/CONTRACTOR

31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER) 30b. NAME AND TITLE OF SIGNER (TYPE OR PRINT) 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER (TYPE OR PRINT) 31c. DATE SIGNED

AUTHORIZED FOR LOCAL REPRODUCTION

(REV. NOV 2021)

PREVIOUS EDITION IS NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.212

7. FOR SOLICITATION

INFORMATION CALL:

STANDARD FORM 1449

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL

PRODUCTS AND COMMERCIAL SERVICES

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30

520-24-1-595-0001 36C25623Q0784 04-07-2023 Tina Harris 228-523-5066 04-20-2023

12PM

CDT

Department of Veterans Affairs Gulf Coast Veterans Health Care System Network Contracting Office 16 400 Veterans Avenue Biloxi MS 39531 X X 561621 $22 Million N/A X Department of Veterans Affairs Gulf Coast Veterans Health Care System Network Contracting Office 16 400 Veterans Avenue Biloxi MS 39531 Department of Veterans Affairs Gulf Coast Veterans Health Care System Network Contracting Office 16 400 Veterans Avenue Biloxi MS 39531

FSC e-Invoice Payment http://www.fsc.va.gov/fsc/einvoice.asp Invoice Setup Information 1-877-489-6135 invoice must be submitted electronically 1-877-489-6135 See CONTINUATION Page Nin Personal Fire Alarm testing and Service for the Gulf Coast Veterans Health Care Systems CBOCs as per the statement of work within.

Submit all questions by 12PM CT April 13, 2023, via email to tina.harris3@va.gov Submit quote package by 12PM April 20, 2023, via email too tina.harris3@va.gov This solicitation utilizes FAR 13.106 Comparative Analysis Evaluation See CONTINUATION Page 520-3640162-595-850300-2543 0100401X1 X X X Tina Harris Contracting Officer Table of Contents

SECTION A1
A.1 SF 1449 SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES1
SECTION B - CONTINUATION OF SF 1449 BLOCKS4
B.1 CONTRACT ADMINISTRATION DATA4
B.2 SCOPE OF WORK5
B.3 PRICE/COST SCHEDULE57
ITEM INFORMATION57
SECTION C - CONTRACT CLAUSES66
C.1 ADDENDUM to FAR 52.212-4 CONTRACT TERMS AND CONDITIONS—COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES66
C.2 52.217-8 OPTION TO EXTEND SERVICES (NOV 1999)66
C.3 52.217-9 OPTION TO EXTEND THE TERM OF THE CONTRACT (MAR 2000)66
C.4 VHA SUPPLEMENTAL CONTRACT REQUIREMENTS FOR ENSURING ADEQUATE COVID-19 SAFETY PROTOCOLS FOR FEDERAL CONTRACTORS66
C.5 52.232-19 AVAILABILITY OF FUNDS FOR THE NEXT FISCAL YEAR (APR 1984)67
C.6 VAAR 852.201-70 CONTRACTING OFFICER'S REPRESENTATIVE (DEC 2022)67
C.7 VAAR 852.203-70 COMMERCIAL ADVERTISING (MAY 2018)68
C.8 VAAR 852.219-73 VA NOTICE OF TOTAL SET-ASIDE FOR VERIFIED SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESSES (NOV 2022)68
C.9 VAAR 852.219-75 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING--CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (NOV 2022)71
C.10 VAAR 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS (NOV 2018)72
C.11 VAAR 852.237-75 KEY PERSONNEL (OCT 2019)73
C.12 VAAR 852.242-71 ADMINISTRATIVE CONTRACTING OFFICER (OCT 2020)74
C.13 52.252-2 CLAUSES INCORPORATED BY REFERENCE (FEB 1998)74
C.14 52.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS—COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES (MAR 2023)75
SECTION D - CONTRACT DOCUMENTS, EXHIBITS, OR ATTACHMENTS83
ATTACHMENT 1 Wage Determination Bay County 15-4559 REV 22 Dated 12-27-22.83
ATTACHMENT 2 Wage Determination Escambia County 15-4561 REV 22 Dated 12-27-2022.83
ATTACHMENT 3 Wage Determination Okaloosa County 15-4531 REV 22 Dated 12-27-2022.83
ATTACHMENT 4 LIST OF PAST PERFORMANCE REFERENCES.83
ATTACHMENT 5 PAST PERFORMACE QUESTIONAIRE.83
ATTACHMENT 6 CONTRACTOR CERTIFICATION.83
SECTION E - SOLICITATION PROVISIONS83
E.1 ADDENDUM to FAR 52.212-1 INSTRUCTIONS TO OFFERORS—COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES83
E.2 52.204-24 REPRESENTATION REGARDING CERTAIN TELECOMMUNICATIONS AND VIDEO SURVEILLANCE SERVICES OR EQUIPMENT (NOV 2021)85
E.3 52.252-1 SOLICITATION PROVISIONS INCORPORATED BY REFERENCE (FEB 1998)88
E.4 VAAR 852.252-70 SOLICITATION PROVISIONS OR CLAUSES INCORPORATED BY REFERENCE (JAN 2008)89
E.5 52.212-2 EVALUATION—COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES (NOV 2021)89
E.6 52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS—COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES (DEC 2022)91

SECTION B - CONTINUATION OF SF 1449 BLOCKS

B.1 CONTRACT ADMINISTRATION DATA

1. Contract Administration: All contract administration matters will be handled by the following individuals:

a. CONTRACTOR:

b. GOVERNMENT: Contracting Officer 36C256 Tina Harris tina.harris3@va.gov Department of Veterans Affairs Gulf Coast Veterans Health Care System Network Contracting Office 16 400 Veterans Avenue Biloxi MS 39531

2. CONTRACTOR REMITTANCE ADDRESS: All payments by the Government to the contractor will be made in accordance with:

[X]
52.232-33, Payment by Electronic Funds Transfer—System For Award Management, or
[]
52.232-36, Payment by Third Party

3. INVOICES: Invoices shall be submitted in arrears:

a. Quarterly[]
b. Semi-Annually[]
c. Other[X] Monthly in Arrears

4. GOVERNMENT INVOICE ADDRESS: All Invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests.

ACKNOWLEDGMENT OF AMENDMENTS: The offeror acknowledges receipt of amendments to the Solicitation numbered and dated as follows:

AMENDMENT NO
DATE

36C25623Q0784

Page 1 of Page 1 of

B.2 SCOPE OF WORK

FIRE ALARM TESTING, INSPECTIONS, MAINTENANCE AND REPAIRS

(Gulf Coast Veterans Healthcare System (GCVHCS) Pensacola JACC, Eglin & Panama City CBOCs)

I. DESCRIPTION OF WORK:

a. Contractor shall provide all tools, parts, labor, transportation, and supervision, necessary to provide maintenance, repairs and perform annual testing and inspections (including telephone and on-site service and support for the below fire alarm system(s) as listed below.

b. Contractor shall provide, at a time designated by the COTR and agreed upon by the contractor, an annual Fire Alarm test. The test shall be performed in strict accordance with the latest versions of NFPA 25, 70, and 72. The contractor shall be given at least 30 days’ notice for the annual test. The date for the test shall occur in the fourth fiscal quarter (July, August, September). The contractor shall provide all forms, reports, test equipment, and consumables (approved canned smoke, etc.) necessary to perform a complete, code compliant assessment. Repair labor for any discrepancies noted during the fire alarm test shall be included. The VA will provide parts, necessary support, and oversight for the test. A device listing is provided for each facility.

c. In addition to annual testing services contractor shall provide for service, updates, programming, troubleshooting, in-house training, and repairs to the Simplex Systems (3 in total). Standard non-emergency service response shall typically be same day or within 24 hours. Contractor shall provide 24/7 emergency service including weekends and holidays with a response time of no more than two (2) hours. The VA will provide support as necessary from the Engineering and/or Safety Sections. Contractor shall contact M&O Supervisor, or Supervisory Engineer to coordinate all work on any part of the fire alarm system.

d. All work will be performed at the following locations:

Gulf Coast Veterans Healthcare System (GCVHCS), Joint Ambulatory Care Clinic Pensacola 790 Veterans Way Pensacola, Florida 32507

Gulf Coast Veterans Healthcare System (GCVHCS) Eglin Community Based Outpatient Clinic 100 Veterans Way Eglin AFB, Florida 32542

Gulf Coast Veterans Healthcare System (GCVHCS) Panama City Community Based Outpatient Clinic 2600 Veterans Way Panama City Beach, Florida 32408

e. Maintenance and testing shall be performed mostly during normal business hours, 8:00 a.m. through 4:30 p.m., Monday through Friday, excluding federal government holidays.

f. The period of performance for this contract is from October 1 thru September 30.

II. SPECIFICATIONS:

a. Contractor shall provide the Contracting Officers Representative (COR), with an annual schedule for facility testing. The Contractor shall notify the (COR) at least fourteen (14) days in advance of plans to perform inspections and testing. The (COR) must give prior approval for the shutdown of the fire alarm system for any area or building being tested.

b. The test shall be performed in strict accordance with the latest versions of NFPA 25, 70, and 72 and using approved test methods manufacturer's specifications and must be performed as expertly and expeditiously as possible.

c. At no time will the main fire alarm panels be left unattended while the system is offline with the monitoring company. Contractor will provide monitoring of the alarm panel while testing is in progress.

d. Medical Center procedures are to be followed for the reporting of alarms while testing is in progress.

e. No building's system or zone of a system shall be completely shut down for more than one (1) working shift.

f. Device count could be subject to change with ongoing construction projects. The device count will be updated to contractor and Contracting Officer.

III. CONFORMANCE STANDARDS FOR TESTING:

a. Contractor will provide a complete inspection of the campus fire alarm system prior to the expiration of this agreement. This inspection will include all test and verification points with final inspection reports in accordance with NFPA guidelines.

b. Locate Point By Point and Test Each Device (Detectors, Smoke Dampers, Audiovisuals Devices, Speakers and Fire Alarm Pull Stations).

c. All smoke detectors shall be tested using only APPROVED methods and instruments. Verify and confirm HVAC shutdown with testing of duct detectors.

d. Verify off premises transmission equipment.

e. Elevator Recall and Shutdown

f. Printer Operations

g. Voice Alarm Clarity

h. Ground Fault and Trouble Testing (A device on each initiating and signaling zone shall be disconnected to determine proper supervision of wiring. These tests shall NOT be performed at the panel).

i. Fuses checked for proper rating.

j. All testing of devices shall be tested in a manner recognized by the manufacturer and governing authorities.

k. Upon completion of each inspection and/or testing, Contractor shall complete Report of Inspection and Testing, and provide documentation to the COR and M&O Supervisor at the Pensacola JACC.

l. Contractor will provide download / programming support to the VA staff for device adds, moves and changes performed by the VA Electrical Staff. This includes any service, updates, programming, troubleshooting, in-house training, and repairs.

m. Contractor will remove and re-install equipment furnished by the VA as needed, resulting from diagnosis and/or service.

n. Contractor will provide system software upgrades as they become available from the manufacturer.

o. The Contractor shall keep all equipment clean and well ventilated, inspect all system components and note any unusual performances, test-check operation of all equipment as part of the inspection.

p. Contractor shall program and perform minor adjustments as needed at the time of the inspection.

q. All devices and device covers shall be securely fastened upon completion of testing.

IV. MAINTENANCE SUPPORT:

a. As a manufacturer authorized representative of the installed systems (Simplex, Notifier, Silent Night), Contractor will provide maintenance support to the JACC Electrical Department as follows.

i. This agreement includes three hundred twenty (320) technician hours for phone or on-site support. Hours will be used on an as needed basis to provide required necessary support. Hours will be accounted by Contractor and report will be available upon request by the COR.

ii. Where physical device and wire-level diagnosis exceeds resources of the VA Electrical Shop, Contractor will assist per incident as requested drawing from the provided maintenance hours in this agreement.

b. Additional repair work to include materials, parts and labor may be added to this contract in a future contract modification if the agreement is bilateral between the VHA and the contractor. Also, if additional work not included under the definitions laid out in this document are required to satisfy the contractual requirements and performance criteria, the contractor shall provide the nature of the repair and a budgetary cost estimate in the format of a detailed cost line-item quote (including line items for labor, materials, and all other related costs) needed to complete repairs in an inspection summary report. Any additional charges and repair work claimed must be approved by the contracting officer before service commences. Any additional work performed by the contractor without the prior written approval of the CO will be performed by the contractor at no additional cost to the government.

c. Once it has been determined and agreed upon both by the VHA and the contractor that the additional services needed to affect repairs are not included in this contractual performance work statement, monetary funds will need to be requested and approved by means of a PO with a GPC if total repair expenses are less than $2500.00 or through means of a contract modification if total repair expenses are greater than $2500.00. The VATR does not have the authority to approve the work outside of the performance work statement and any work performed by the contractor in good faith outside of the performance work statement. Any work performed by the contractor without the approval of the contracting officer or an approved purchase through a credit card PO will be completed or resolved at the expense of the contractor and not the VHA.

d. The OEM approved contractor shall provide all equipment and materials needed to provide the services in this contract for Fire Alarm System related action items (i.e., tools, PPE, transportation, etc.). Parts may be repaired or replaced, as the contractor deems appropriate, so long as amount listed in CLINs cited in Price Schedule are not exceeded. No used parts will be used to repair this equipment. Contactor shall furnish the VATR with a written estimate of the cost to make necessary repairs. Contractor shall also provide a comparison quote to the VATR for what that item would have cost for commercial pricing so Government has basis for making price fair and reasonableness determination, or as alternative, Contractor shall provide a quote provided to another federal agency for similar item for determination purposes. If cost exceeds cost listed for applicable line item in Section B.2 (Price Schedule), the Contracting Officer shall issue a bilateral contract modification.

e. The contractor has ready access to unique and/or high mortality replacement repair parts. If the contractor supplies or acquires parts supplied parts shall be compatible with existing equipment. The contractor shall use only new or rebuilt parts, approved by the OEM, and shall not install used parts or those removed from another system without written COR approval.

V. LOCATION AND DESCRIPTION OF FIRE ALARM SYSTEMS:

a. GCVHCS Joint Ambulatory Care Clinic Pensacola

i. Duct- smoke detectors (18), heat detectors (6), smoke detectors (155), fire alarm pull stations (21), Speakers (354), Strobes (260), Speaker/strobe combination units (213), alarm control panels (2), auxiliary controls (30), door release devices (40), multiplex transponder (4), Alarm annunciator (1), elevator alternate recall (3), elevator primary recall (3), Range Hood (1), supervisory devices (Telephone dialer (1), Door Magnets (21) and Sprinkler Tamper Switches (28), water flow devices (13), power supply (6), Batteries (13), Monaco transmitters (1) and beam detectors (3 sets). This facility has 2 CPU systems Simplex 4100U is located on the 1st floor in the VA Police Office and Simplex 5120-9416 located on the 2nd floor located in room 2B160).

ii. Full device listing is Enclosure A at the end of this document

b. GCVHCS Eglin CBOC

i. Duct- smoke detectors (3), smoke detectors (5), fire alarm pull stations (14), Horns (20), Strobes (8), audio/visual combination units (20), alarm control panels (1), communicator (1), Annunciator (1), power supply (3), Batteries (7), supervisory devices (Telephone dialer (1), Sprinkler Tamper Switches (4), water flow switch (2), Door Release Devices (10), Monaco transmitters (1). The Alarm panel is manufactured by Notifier, model NFS-2-640.

ii. Full device listing is Enclosure B at the end of this document

c. GCVHCS Panama City CBOC

i. Duct- smoke detectors (4), smoke detectors (4), fire alarm pull stations (10), visual circuits (8), speaker/strobe combination units (37), speaker (40) alarm control panels (1), release devices ( ), supervisory devices Telephone dialer (1), Sprinkler Tamper Switches (2), water flow devices (1), power supplies (3), Batteries (9) and Monaco transmitters (1). The Alarm panel is manufactured by Silent Night, model IFP-2000.

ii. Full device listing is Enclosure C at the end of this document

VI. EXCLUSIONS

a. Damage by others. Contractor in applications where results of diagnosis proves damage caused by others, Contractor reserves the right to invoice other parties for time expended by Contractor.

b. Diagnosis and repair under this agreement excludes issues created in or created by any contract project performed by others and systems not a part of the existing campus system at the time of this signing.

c. The provision of any equipment, components and/or cable needed while performing this agreement is excluded and will be provided by the VA or upon request provided and invoiced by Contractor.

d. Sales Tax when/if applicable.

e. 120 VAC electrical circuits for control equipment.

f. LAN/WAN infrastructures.

g. Equipment and devices interfaced to any of the maintained systems within this contract are excluded from service or responsibility of contractor in any way. These devices and connections may include but not limited to fans, elevators, AHU controls, fire pumps, generators, and fence material. Contractor will service and maintain up to the device that is a part of a maintained system, any connections, wiring or service beyond that device to the interfaced equipment is excluded.

h. Damper control functions, restoration of Air Handling Unit Operation once Fire Alarm relay has been restored.

i. Labor for repairs caused by fire, water, lightning, accident, vandalism, tampering or any other act beyond the control of contractor.

j. Central station monitoring and associated fees (price quotes available) Sprinkler water flow, valve tamper or pressure switches and related installation.

k. Battery replacement.

VII. HOURS OF COVERAGE:

a. Normal business hours of coverage are Monday through Friday from 7:00 am to 4:30pm excluding Federal holidays. All service/repairs will be performed during normal hours of coverage unless requested or approved by the COR.

b. Standard nonemergency service response shall typically be same day or within 24 hours.

c. Emergency service available 24/7 including weekends and holidays with a response time of no more than two (2) hours is included in this maintenance support agreement. Any fire protection systems discovered at the time of inspection or added to the above premises after the date of this agreement shall be inspected by Seller and Customer shall pay an additional price commensurate with the usual charges made by Seller and thereafter such systems will be added to the scope of this Agreement at a mutually agreed upon price.

VIII. DOCUMENTATION/REPORTS:

a. The documentation shall include detailed descriptions of the scheduled and unscheduled maintenance procedures performed, including replaced parts and prices, required to maintain the equipment in accordance with conformance standards. Such documentation on shall meet the guidelines as set forth in the above listed Conformance Standards. In addition, each ESR shall at a minimum document the following data legibly and in complete detail:

Name of Contractor Name of FSE who performed services Contractor Service ESR Number/Log Number Date, Time (starting and ending), Equipment Downtime and Hours on Site for service call.

VAGCVHCS PO#(s) covering the call, if outside normal working hours Description of Problem Reported by COTR/User.

Identification of Equipment to be serviced:

Equipment Inventory ID#, Manufacturer's Name, Device Name, Model, Serial#, and any other Manufacturer's identification #s.

Itemized Description of Service Performed (including costs associated with after normal business working hours service), including:

List of Parts (with part #s), Materials and Circu1·t Location of Problem, and Corrective Action taken.

Signatures FSE performing services described.

VA Employee who witnessed service described.

Equipment downtime.

NOTE: ANY ADDITIONAL CHARGES CLAIMED MUST BE APPROVED BY THE COTR IN

ADVANCE BEFORE THE SERVICE IS COMPLETED AND A SEPARATE PURCHASE ORDER ISSUED.

b. Annual inspections shall be performed during the fourth quarter of the fiscal year, coordinated with COR and M&O Supervisor. Inspections will be scheduled at least two weeks in advance.

c. Work performed outside the normal hours of coverage as approved by the COR shall not result in additional charges. Work performed outside normal hours of coverage at the request of the FSE shall be considered service during normal hours of coverage.

IX. COMPETENCIES

a. Prior to commencement of work on this contract, the contract awardee shall provide the VAGCVHCS with a copy of the current calibration certification of all test equipment that is to be used by the contractor on VAGCVHCS' equipment, not later than ten (10) calendar days after contract award.

b. Contractor will provide diagnosis of software and programming related issues on systems in use on the date of signing of this agreement.

c. Each respondent must have an established business, with an office and full-time staff. The staff includes a "fully qualified" FSE and a "fully qualified" FSE who will serve as the backup.

Enclosure A (Pensacola):

Pensacola JACC

Zone/Circuit: 1

Address
Device Type
Location
Type
3
Smoke Detector
1 Mail Room 1A133
3
Smoke Detector
1 Mail Room 1A133
4
Smoke Detector
1 Room 1C101
Photoelectric
5
Smoke Detector
1 Room 1A132
Photoelectric
6
Smoke Detector
1 Reception 1A132
Photoelectric
7
Heat Detector
1 Mech Room 1G101A
8
Smoke Detector
1 Room 1G101A
Photoelectric
9
Pull Station
1 Main Entrance
10
Smoke Detector
1 Lobby By Main Entrance
Photoelectric
11
Smoke Detector
1 Waiting Area 1A116
Photoelectric
12
Smoke Detector
1 Southwest Elevator Lobby
Photoelectric
13
Smoke Detector
1 Lobby By Southwest Elevator
Photoelectric
14
Smoke Detector
1 Southwest Elevator Lobby
Photoelectric
15
Smoke Detector
1 Reception 1A132
16
Smoke Detector
1 Restroom 1C101A
17
Smoke Detector
1 Mail Room 1A133
18
Smoke Detector
1 Room 1A133
19
Smoke Detector
1 Lobby By Restroom 1C101A
24
Smoke Detector
1 Waiting Area 1B112
25
Smoke Detector
1 Room 1B114
26
Smoke Detector
1 Waiting Area 1B112
27
Smoke Detector
1 Waiting Area 1B112
28
Smoke Detector
1 Room 1B111
29
Smoke Detector
1 Lobby 1G101
30
Smoke Detector
1 Room 1B107A
31
Smoke Detector
1 Lobby 1G101
32
Smoke Detector
1 Restroom 1B106
33
Smoke Detector
1 Lobby 1G101
34
Smoke Detector
1 Canteen 1B104
35
Smoke Detector
1 Elect. Room 1B108
Photoelectric
36
Smoke Detector
1 By Elect. Room 1B108
Photoelectric
37
Pull Station
1 Canteen Room 1B104
39
Smoke Detector
1 Corr By Room 1B119
Photoelectric
40
Smoke Detector
1 Corr By Room 1B119
Photoelectric
41
Smoke Detector
1 Reception 1D162
Photoelectric
42
Smoke Detector
1 Lobby 1G103
Photoelectric
43
Smoke Detector
1 Lobby 1G103
Photoelectric
44
Smoke Detector
1 Lobby 1G103
Photoelectric
45
Smoke Detector
1 Room 1D148
Photoelectric
46
Smoke Detector
1 Lobby 1G103
Photoelectric
47
Smoke Detector
1 Waiting Area 1D100
Photoelectric
48
Smoke Detector
1 Lobby 1G102
Photoelectric
49
Smoke Detector
1 Lobby 1G102
Photoelectric
50
Smoke Detector
1 Reception 1F151
Photoelectric
52
Smoke Detector
1 Waiting Area 1F150
Photoelectric
53
Smoke Detector
1 Waiting Area 1F150
Photoelectric
54
Heat Detector
1 Mech Room 1F150A Elevator Mech
55
Smoke Detector
1 Mech Room 1F150A Elevator Mech
Photoelectric
56
Smoke Detector
1 Waiting Area 1F100
Photoelectric
57
Smoke Detector
1 Waiting Area 1F100
Photoelectric
58
Smoke Detector
1 Restroom 1B107
Photoelectric
59
Tamper Switch
1 East Stairs
59
Waterflow Switch
1 Stairs By Main Entrance
61
Tamper Switch
1 Canteen 1A140
64
Smoke Detector
1 Above FACP
Photoelectric
65
Smoke Detector
1 Police Room
Photoelectric
70
Tamper Switch
1 Canteen 1B104
135
Smoke Detector
1 Elect. Room
Photoelectric
136
Smoke Detector
1 Elect. Room 1B180
Photoelectric
137
Smoke Detector
1 Elect. Room 1B180
Photoelectric
138
Smoke Detector
1 Room 1B180
Photoelectric
139
Smoke Detector
1 IT Room 1B138
Photoelectric
140
Smoke Detector
1 Room 1D114
Photoelectric
141
Smoke Detector
1 Elect. Room 147
Photoelectric
142
Smoke Detector
1 Elect. Room 1A115
Photoelectric
143
Smoke Detector
1 IT Room 1A138

Zone/Circuit: 2

4
Smoke Detector
1 Reception 1C175
Photoelectric
5
Smoke Detector
1 Reception
Photoelectric
6
Smoke Detector
1 Waiting Area
Photoelectric
7
Smoke Detector
1 Waiting Area 1C174
Photoelectric
8
Smoke Detector
1 Elect. Room 1C173
Photoelectric
9
Smoke Detector
1 Waiting Area
Photoelectric
10
Smoke Detector
1 Waiting Area
Photoelectric
11
Smoke Detector
1 Lobby 1G103
Photoelectric
12
Smoke Detector
1 Lobby 1G103
Photoelectric
13
Tamper Switch
1 Stairs By Room 1E111
14
Smoke Detector
1 Lobby 1G103
Photoelectric
15
Smoke Detector
1 Restroom 1C136
Photoelectric
16
Smoke Detector
1 Restroom 1C135
Photoelectric
17
Smoke Detector
1 Lobby 1G103
Photoelectric
18
Smoke Detector
1 Lobby 1G102
Photoelectric
19
Smoke Detector
1 Lobby 1G103
Photoelectric
20
Pull Station
1 Corr C1-34
21
Pull Station
1 Corr C1-34 By Stairs
22
Smoke Detector
1 Navy Waiting
Photoelectric
23
Smoke Detector
1 C&P OCC Waiting
Photoelectric
24
Smoke Detector
1 Navy LCPO Reception
Photoelectric
26
Smoke Detector
1 Navy LCPO Reception
Photoelectric
27
Smoke Detector
1 Lobby 1G103
Photoelectric
28
Smoke Detector
1 Elect. Room 1E100
Photoelectric
29
Smoke Detector
1 Restroom 1C209
Photoelectric
30
Smoke Detector
1 Restroom 1C210
Photoelectric
31
Smoke Detector
1 Lobby 1G103
Photoelectric
32
Smoke Detector
1 North Elev. Lobby 1G104
Photoelectric
33
Smoke Detector
1 Lobby 1G104
Photoelectric
34
Smoke Detector
1 Lobby 1G104
Photoelectric
35
Smoke Detector
1 Lobby 1G104
Photoelectric
36
Pull Station
1 Lobby 1G104
37
Tamper Switch
1 Center Atrium Stairs
37
Waterflow Switch
1 Center Atrium Stairs
38
Tamper Switch
1 Corr By 1C173
39
Smoke Detector
1 Comm Room 1C175
Photoelectric
54
Smoke Detector
2 North Elev. Lobby Top Of Shaft
Photoelectric
55
Heat Detector
2 North Elev Top Of Shaft
56
Smoke Detector
2 North Elev. Lobby
Photoelectric
36
Pull Station
1 Lobby 1G104
37
Tamper Switch
1 Center Atrium Stairs
37
Waterflow Switch
1 Center Atrium Stairs
38
Tamper Switch
1 Corr By 1C173
39
Smoke Detector
1 Comm Room 1C175
Photoelectric
54
Smoke Detector
2 North Elev. Lobby Top Of Shaft
Photoelectric
55
Heat Detector
2 North Elev Top Of Shaft
56
Smoke Detector
2 North Elev. Lobby
Photoelectric

Zone/Circuit: 3

1
Pull Station
1 Mech Room 1B179
8
Pull Station
1 Corr C1-89
9
Pull Station
1 Gen Medical 1B172
10
Pull Station
1 Carpentry Room 1B159
11
Tamper Switch
1 MRI Change Room
12
Smoke Detector
1 MRI Room 1D117
Photoelectric
13
Smoke Detector
1 MRI Room 1D117
Photoelectric
14
Tamper Switch
1 Stairs By Elect. Room 1D114
14
Waterflow Switch
1 Stairs By Elect. Room 1D114
15
Smoke Detector
1 Mech Room C1-81A SE Elevator Mech
Photoelectric
16
Heat Detector
1 Mech Room C1-81A SE Elevator Mech
17
Smoke Detector
1 Southeast Elev.Lobby C1-83
Photoelectric
18
Pull Station
1 Corr By Ambulance Vest
19
Pull Station
1 Ambulance Vest
24
Smoke Detector
1 Corr C1-60
Photoelectric
25
Smoke Detector
1 Room 1F101
Photoelectric
26
Pull Station
1 Corr C1-59 By Stairs
27
Pull Station
1 Corr C1-69
28
Waterflow Switch
1 North East Stairs
28
Tamper Switch
2 North East Stairs
29
Tamper Switch
1 Corr By Ambulance Exit
30
Smoke Detector
1 Comm Room 1D178
Photoelectric
38
Waterflow Switch
1 Exterior Pump House
41
Tamper Switch
1 Corr By NE Stairs
42
Duct Detector
1 Housekeeping 1B176
Photoelectric
48
Duct Detector
1 Mech Room 1B179
Photoelectric

Zone/Circuit: 4

1
Smoke Detector
2 Corr C2-78
Photoelectric
2
Smoke Detector
2 Room 2B148
Photoelectric
3
Smoke Detector
2 Waiting Area 2B127
Photoelectric
4
Smoke Detector
2 Passage 2G105
Photoelectric
5
Smoke Detector
2 Elect Room 2D150
Photoelectric
5
Smoke Detector
2 Passage 2G105
Photoelectric
6
Smoke Detector
2 Passage 2G105
Photoelectric
7
Smoke Detector
2 Waiting Area 2B126
Photoelectric
8
Smoke Detector
2 Clerk Room 2B101
Photoelectric
9
Smoke Detector
2 Waiting Area 2B100
Photoelectric
10
Smoke Detector
2 Passage 2G102
Photoelectric
11
Smoke Detector
2 Corr C2-88
Photoelectric
12
Smoke Detector
2 Room 2B157
Photoelectric
13
Smoke Detector
2 Room 2B157
Photoelectric
14
Smoke Detector
2 Room 2B157
Photoelectric
15
Smoke Detector
2 Room 2B157
Photoelectric
16
Pull Station
2 Stairs By Main Entrance
17
Smoke Detector
2 Waiting Area
Photoelectric
20
Smoke Detector
2 Reception 2D102
Photoelectric
21
Smoke Detector
2 Corr 2G108
Photoelectric
22
Smoke Detector
2 Reception 2D102
Photoelectric
23
Smoke Detector
2 Waiting Area 2D100
Photoelectric
24
Smoke Detector
2 Waiting Area 2D100
Photoelectric
25
Smoke Detector
2 Corr C2-77
Photoelectric
26
Smoke Detector
2 Corr C2-76
Photoelectric
27
Pull Station
2 Corr C2-75
28
Smoke Detector
2 Southeast Elev. Top Of Shaft
Photoelectric
29
Heat Detector
2 Southeast Elev Top Of Shaft
30
Smoke Detector
2 Southeast Elev. Lobby C2-76
Photoelectric
33
Smoke Detector
2 Passage 2G111
Photoelectric
34
Smoke Detector
2 Passage 2G111
Photoelectric
35
Smoke Detector
2 Corr C2-61
Photoelectric
36
Smoke Detector
2 Reception 2D154
Photoelectric
37
Smoke Detector
2 Reception 2D154
Photoelectric
38
Smoke Detector
2 Passage 2G109
Photoelectric
39
Smoke Detector
2 Corr C2-67
Photoelectric
40
Pull Station
2 Prep Rec 2D168
41
Duct Detector
3 AHU 3
Photoelectric
42
Duct Detector
3 AHU 8
Photoelectric
43
Duct Detector
3 AHU 3
Photoelectric
46
Duct Detector
3 AHU 5
Photoelectric
48
Duct Detector
3 AHU 2
Photoelectric
49
Tamper Switch
1 Main Entrance
49
Waterflow Switch
3 West Stairs
50
Waterflow Switch
3 Center Stair #7
51
Pull Station
3 Central Stairs
52
Duct Detector
3 AHU 4
Photoelectric
53
Duct Detector
3 AHU 4
Photoelectric
54
Duct Detector
3 AHU 4
Photoelectric
55
Duct Detector
2 Center Lobby AHU 3
Photoelectric
56
Pull Station
3 South Stairs
57
Duct Detector
3 AHU 6
Photoelectric
59
Duct Detector
3 AHU 1
Photoelectric
60
Duct Detector
3rd AHU 9
Photoelectric
67
Duct Detector
2 Center Lobby AHU 2
Photoelectric
68
Duct Detector
2 Center Lobby AHU 4
Photoelectric
69
Duct Detector
2 Center Lobby AHU 1
Photoelectric
70
Tamper Switch
2 By Main Entrance
70
Waterflow Switch
2 Stairs By Main Entrance
71
Tamper Switch
2 Stairs By Ambulance Entrance
71
Waterflow Switch
2 Stairs By Ambulance Exit
72
Smoke Detector
2 Comm Room 2D135
Photoelectric
73
Duct Detector
3 AHU 6
Photoelectric
74
Tamper Switch
1 Corr By Northeast Stairs
66918029
74
Waterflow Switch
2 North East Stairs
130
Smoke Detector
2 IT Room 2B157
Photoelectric
131
Smoke Detector
2 IT Room 2B157
Photoelectric
132
Smoke Detector
2 Elect Room 2B150
Photoelectric
133
Smoke Detector
2 IT Room 2B160
Photoelectric
134
Smoke Detector
2 IT Room 2B160
Photoelectric

Zone/Circuit: 5

1
Smoke Detector
2 Waiting Area 2C100
Photoelectric
2
Smoke Detector
2 Waiting Area 2A136
Photoelectric
3
Beam Detector
South Lobby
4
Beam Detector
Center Lobby
5
Smoke Detector
2 Waiting Area 2C100
Photoelectric
6
Smoke Detector
2 Southwest Elevator Top Of Shaft
Photoelectric
7
Smoke Detector
2 Southwest Elev. Lobby
Photoelectric
8
Heat Detector
2 Southwest Elev Top OF Shaft
9
Smoke Detector
2 Southwest Elev. Lobby
Photoelectric
11
Smoke Detector
2 Waiting Area 2A100A
Photoelectric
12
Beam Detector
North Lobby
15
Pull Station
2 Southwest Stairs
16
Smoke Detector
2 Room 2C172
Photoelectric
17
Smoke Detector
2 Waiting Area 2C127
Photoelectric
18
Smoke Detector
2 Room 2C102
Photoelectric
19
Smoke Detector
2 Room 2C102
Photoelectric
20
Smoke Detector
2 Reception 2C171
Photoelectric
21
Smoke Detector
2 Reception 2C171
Photoelectric
22
Smoke Detector
2 Waiting Area 2C170
Photoelectric
23
Smoke Detector
2 O S Room 2C169
Photoelectric
24
Smoke Detector
2 Elect Room 2C169
Photoelectric
25
Smoke Detector
2 Near Waiting Area 2C128
Photoelectric
27
Smoke Detector
2 Reception 2C101
Photoelectric
28
Smoke Detector
2 Near Reception 2C171
Photoelectric
29
Pull Station
2 Passage 2G107
30
Smoke Detector
2 Waiting Area 2C207
Photoelectric
31
Smoke Detector
2 Waiting Area 2C207
Photoelectric
38
Smoke Detector
2 Waiting Area 2C127
Photoelectric
39
Smoke Detector
2 Waiting Area 2C127
Photoelectric
40
Pull Station
2 Corr C2-36
41
Smoke Detector
2 Reception 2E131A
Photoelectric
42
Smoke Detector
2 Reception 2E131A
Photoelectric
43
Smoke Detector
2 Passage 2G110
Photoelectric
44
Smoke Detector
2 Waiting Area 2E100
Photoelectric
45
Smoke Detector
2 Elect Room 2E101
Photoelectric
46
Smoke Detector
2 Restroom 2C205
Photoelectric
47
Smoke Detector
2 Restroom 2C206
Photoelectric
51
Smoke Detector
2 Passage 2G113
Photoelectric
52
Smoke Detector
2 Waiting Area 2E130
Photoelectric
56
Smoke Detector
2 Waiting Area 2E100
Photoelectric
60
Tamper Switch
2 Atrium Stairs
60
Waterflow Switch
2 Atrium Stairs
61
Smoke Detector
2 Comm Room 2E106
Photoelectric
62
Smoke Detector
2 Restroom 2C129
Photoelectric
63
Smoke Detector
2 Restroom 2C130
Photoelectric
64
Smoke Detector
2 South Lobby
Photoelectric
128
Smoke Detector
2 IT Room 2A137
Photoelectric
129
Smoke Detector
2 Elect Room 1A134
Photoelectric
1042
Releasing Device
1 By 1F101
Door Holder
1043
Releasing Device
1 By 1F156
Door Holder
1044
Releasing Device
1 Canteen
Door Holder
1045
Releasing Device
1 Canteen
Door Holder
1046
Releasing Device
1 Corr C1-82
Door Holder
1047
Releasing Device
1 Corr C1-87
Door Holder
1048
Releasing Device
1 Corr C1-88
Door Holder
1049
Releasing Device
1 Waiting Area 1B112
Door Holder
1050
Releasing Device
1 Lobby By 2D155
Door Holder
1051
Releasing Device
1 Lobby By 2D155
Door Holder
1052
Releasing Device
1 Corr C2-77
Door Holder
1053
Releasing Device
1 Corr C2-76
Door Holder
1054
Releasing Device
1 Vestibule 1B200
Door Holder
1055
Releasing Device
1 Stairs By Vestibule 1B200
Door Holder
1056
Releasing Device
1 Stair By Corr C1-69
Door Holder
1057
Releasing Device
1 Stair By Corr C1-34
Door Holder
1058
Releasing Device
1 Stair By Corr C1-10
Door Holder
1059
Releasing Device
1 Room 1B172
Door Holder
1060
Releasing Device
1 Room 1B161
Door Holder
1061
Releasing Device
1 Room 1B159
Door Holder
1062
Releasing Device
1 2C-102 Eye Clinic India
Door Holder
1063
Releasing Device
1 2B-102 Eye Clinic India
Door Holder
1064
Releasing Device
1 Room 1D-179 Prosthetics
Door Holder
1065
Releasing Device
1 Corr C1-69
Door Holder
1065
Releasing Device
1 Room 1D-112 MRI Sup. Hallway
Door Holder
1066
Releasing Device
1 C2-01 Navy Admin.
Door Holder
1066
Releasing Device
1 Corr C1-10
Door Holder
1067
Releasing Device
1 Corr C1-34
Door Holder
1068
Releasing Device
1 Corr C1-89
Door Holder
1069
Releasing Device
2 Corr C2-61
Door Holder
1070
Releasing Device
2 Room 2D155
Door Holder
1071
Releasing Device
2 Stairwell 2
Door Holder
1072
Releasing Device
2 Corr C2-69 South
Door Holder
1073
Releasing Device
2 Corr C2-69 North
Door Holder
1074
Releasing Device
2 Corr C2-68 West
Door Holder
1075
Releasing Device
2 Corr C2-68 East
Door Holder
1076
Releasing Device
2 Corr C2-67
Door Holder
1077
Releasing Device
2 Reception 2D154
Door Holder
1078
Releasing Device
1 Pharmacy
Door Holder
1079
Releasing Device
2 Room 2B160
Door Holder
1501
Speaker/Strobe
1 Corridor C1-71
1502
Speaker/Strobe
1 Corridor C1-71
1503
Speaker/Strobe
1 Corridor C1-71
1504
Speaker/Strobe
1 Corridor C1-72
1505
Speaker/Strobe
1 Corridor C1-72
1506
Speaker/Strobe
1 Corridor C1-73
1507
Speaker/Strobe
1 Corridor C1-73
1508
Speaker/Strobe
1 Corridor C1-76
1509
Speaker/Strobe
1 Corridor C1-78
1510
Speaker/Strobe
1 Corridor C1-79
1511
Speaker/Strobe
1 Corridor C1-79
1512
Speaker/Strobe
1 Corridor C1-79A
1513
Speaker/Strobe
1 Corridor C1-80
1514
Speaker/Strobe
1 Corridor C1-81
1515
Speaker/Strobe
1 Corridor C1-82
1516
Speaker/Strobe
1 Corridor C1-83
1517
Speaker/Strobe
1 Corridor C1-83
1518
Speaker/Strobe
1 Corridor C1-86
1519
Speaker/Strobe
1 Corridor C1-87
1520
Speaker/Strobe
1 Corridor C1-88
1521
Speaker/Strobe
1 Corridor C1-88
1522
Speaker/Strobe
1 Corridor C1-89
1523
Speaker/Strobe
1 Corridor C1-89
1524
Speaker/Strobe
1 Corridor C1-90
1525
Speaker/Strobe
1 Corridor C1-92
1526
Speaker/Strobe
1 East Stairs Physical Therapy
1527
Speaker/Strobe
1 Exercise 1F156
1528
Speaker/Strobe
1 Exercise 1F156
1529
Speaker/Strobe
1 Exercise 1F156
1530
Speaker/Strobe
1 Exit At Stairs C1-10
1531
Speaker/Strobe
1 Exit By Corr C1-10
1532
Speaker/Strobe
1 Lobby 1G101
1533
Speaker/Strobe
1 OS Canteen Entrance
1534
Speaker/Strobe
1 OS East Exit Of Corr C1-95
1535
Speaker/Strobe
1 OS Room
1536
Speaker/Strobe
1 OS Room 1A101
1537
Speaker/Strobe
1 OS Room 1A107
1538
Speaker/Strobe
1 OS Room 1A109
1539
Speaker/Strobe
1 OS Room 1A118
1540
Speaker/Strobe
1 OS Room 1A119
1541
Speaker/Strobe
1 OS Room 1A121
1542
Speaker/Strobe
1 OS Room 1A123
1543
Speaker/Strobe
1 OS Room 1A132
1544
Speaker/Strobe
1 OS Room 1A134
1545
Speaker/Strobe
1 OS Room 1A137
1546
Speaker/Strobe
1 OS Room 1A144
1547
Speaker/Strobe
1 OS Room 1A146
1548
Speaker/Strobe
1 OS Room 1A149
1549
Speaker/Strobe
1 OS Room 1B107A
1550
Speaker/Strobe
1 OS Room 1B110
1551
Speaker/Strobe
1 OS Room 1B115
1552
Speaker/Strobe
1 OS Room 1B125
1553
Speaker/Strobe
1 OS Room 1B134
1554
Speaker/Strobe
1 OS Room 1B140
1555
Speaker/Strobe
1 OS Room 1B140
1556
Speaker/Strobe
1 OS Room 1B141
1557
Speaker/Strobe
1 OS Room 1B144
1558
Speaker/Strobe
1 OS Room 1B147
1559
Speaker/Strobe
1 OS Room 1C103
1560
Speaker/Strobe
1 OS Room 1C113
1561
Speaker/Strobe
1 OS Room 1C120
1562
Speaker/Strobe
1 OS Room 1C121
1563
Speaker/Strobe
1 OS Room 1C125
1564
Speaker/Strobe
1 OS Room 1C133
1565
Speaker/Strobe
1 OS Room 1C135
1566
Speaker/Strobe
1 OS Room 1C144
1567
Speaker/Strobe
1 OS Room 1C152
1568
Speaker/Strobe
1 OS Room 1C159
1569
Speaker/Strobe
1 OS Room 1C160
1570
Speaker/Strobe
1 OS Room 1C164
1571
Speaker/Strobe
1 OS Room 1C170
1572
Speaker/Strobe
1 OS Room 1C178
1573
Speaker/Strobe
1 OS Room 1C181
1574
Speaker/Strobe
1 OS Room 1C187
1575
Speaker/Strobe
1 OS Room 1D144
1576
Speaker/Strobe
1 OS Room 1E138
1577
Speaker/Strobe
1 OS Room 1E147
1578
Speaker/Strobe
1 Pharmacy Waiting 1B112
1579
Speaker/Strobe
1 Reception 1C131
1580
Speaker/Strobe
1 Reception 1D102
1581
Speaker/Strobe
1 Room 1B100
1582
Speaker/Strobe
1 Room 1B117
1583
Speaker/Strobe
1 Room 1B118
1584
Speaker/Strobe
1 Room 1B124
1585
Speaker/Strobe
1 Room 1B125
1586
Speaker/Strobe
1 Room 1B159
1587
Speaker/Strobe
1 Room 1B159 Exit
1588
Speaker/Strobe
1 Room 1B162
1589
Speaker/Strobe
1 Room 1B172
1590
Speaker/Strobe
1 Room 1B179
1591
Speaker/Strobe
1 Room 1B179
1592
Speaker/Strobe
1 Room 1B179
1593
Speaker/Strobe
1 Room 1B180
1594
Speaker/Strobe
1 Room 1B180A
1595
Speaker/Strobe
1 Room 1D104
1596
Speaker/Strobe
1 Room 1D110
1597
Speaker/Strobe
1 Room 1D110
1598
Speaker/Strobe
1 Secc 1B149
1601
Speaker/Strobe
1 South West Stairs
1602
Speaker/Strobe
1 Stairs By Abulance Vest
1603
Speaker/Strobe
1 Stairs By Corr C1-34
1604
Speaker/Strobe
1 Waiting Area 1C100
1605
Speaker/Strobe
1 Waiting Area 1C174
1606
Speaker/Strobe
1 Waiting Area 1C211
1607
Speaker/Strobe
1 Waiting Area 1E133
1608
Speaker/Strobe
1 Waiting Area 1F150
1609
Speaker/Strobe
1 West Of 1B140
1610
Speaker/Strobe
1 Alcove C1-60A
1611
Speaker/Strobe
1 Corr C1-69
1612
Speaker/Strobe
1 Canteen
1613
Speaker/Strobe
1 Canteen Front Register
1614
Speaker/Strobe
1 Corr C1-12
1615
Speaker/Strobe
1 Corr C1-94
1616
Speaker/Strobe
1 Corr C1-16
1617
Speaker/Strobe
1 Corr C1-29
1618
Speaker/Strobe
1 Corr C1-30
1619
Speaker
1 Corr C1-32
1620
Speaker
1 Corr C1-33
1621
Speaker
1 Corr C1-34
1622
Speaker
1 Corr C1-35
1623
Speaker
1 Corr C1-36
1624
Speaker
1 Corr C1-37
1625
Speaker
1 Corr C1-38
1626
Speaker
1 Corr C1-39
1627
Speaker
1 Corr C1-40A
1628
Speaker
1 Corr C1-41
1629
Speaker
1 Corr C1-60
1630
Speaker
1 Corr C1-60
1631
Speaker
1 Corr C1-60
1632
Speaker
1 Corr C1-61
1633
Speaker
1 Corr C1-62
1634
Speaker
1 Corr C1-64
1635
Speaker
1 Corr C1-64
1636
Speaker
1 Corr C1-66
1637
Speaker
1 Corr C1-67
1638
Speaker
1 Corr C1-68
1639
Speaker
1 Abulance Vest 1B200
1640
Speaker
1 Corr By Main Entrance
1641
Speaker
1 Police Office
1642
Speaker
1 Room 1B100
1643
Speaker
1 Above Main Reception Desk
1644
Speaker
1 Alcove CT-60A
1645
Speaker
1 By North Exit
1646
Speaker
1 Canteen 1B104
1647
Speaker
1 Canteen 1B104
1648
Speaker
1 Carpentry 1B159
1649
Speaker
1 Corr C1-60
1650
Speaker
1 Corr C189
1651
Speaker
1 Corr C189
1652
Speaker
1 Corr C189
1653
Speaker
1 Corr By 1C134
1654
Speaker
1 Corr By R R 1A139
1655
Speaker
1 Corr By R R 1C101A
1656
Speaker
1 Corr By R R 1C210
1657
Speaker
1 Corr By South Elevator
1658
Speaker
1 Corr By Waitng Area 1A116
1659
Speaker
1 Corr By Waitng Area 1A132
1660
Speaker
1 Corr By Waitng Area 1C211
1661
Speaker
1 Corr By Waitng Area 1C100
1662
Speaker
1 Corr C1-03
1663
Speaker
1 Corr C1-08
1664
Speaker
1 Corr C1-11
1665
Speaker
1 Corr C1-12
1666
Speaker
1 Corr C1-13
1667
Speaker
1 Corr C1-14
1668
Speaker
1 Corr C1-15
1669
Speaker
1 Corr C1-15
1670
Speaker
1 Corr C1-17
1671
Speaker
1 Corr C1-18
1672
Speaker
1 Corr C1-19
1673
Speaker
1 Corr C1-19
1674
Speaker
1 Corr C1-21
1675
Speaker
1 Corr C1-22
1676
Speaker
1 Corr C1-23
1677
Speaker
1 Corr C1-23
1678
Speaker
1 Corr C1-23
1679
Speaker
1 Corr C1-24
1680
Speaker
1 Corr C1-26
1681
Speaker
1 Corr C1-26
1682
Speaker
1 Corr C1-28
1683
Speaker
1 Corr C1-28
1684
Speaker
1 Corr C1-29
1685
Speaker
1 Corr C1-29
1686
Speaker
1 Corr C1-30
1687
Speaker
1 Corr C1-31
1688
Speaker
1 Corr C1-31
1689
Speaker
1 Corr C1-32
1690
Speaker
1 Corr C1-32
1691
Speaker
1 Corr C1-32
1692
Speaker
1 Corr C1-33
1693
Speaker
1 Corr C1-34
1694
Speaker
1 Corr C1-35
1695
Speaker
1 Corr C1-37
1696
Speaker
1 Corr C1-38
1697
Speaker
1 Corr C1-38
1698
Speaker
1 Corr C1-39
1699
Speaker
1 Corr C1-40
1700
Speaker
1 Corr C1-41
1701
Speaker
1 Corr C1-42
1702
Speaker
1 Corr C1-42
1703
Speaker
1 Corr C1-42
1704
Speaker
1 Corr C1-42
1705
Speaker
1 Corr C1-60
1706
Speaker
1 Corr C1-60
1707
Speaker
1 Corr C1-60
1708
Speaker
1 Corr C1-60
1709
Speaker
1 Corr C1-62
1710
Speaker
1 Corr C1-62
1711
Speaker
1 Corr C1-62
1712
Speaker
1 Corr C1-64
1713
Speaker
1 Corr C1-64
1714
Speaker
1 Corr C1-64
1715
Speaker
1 Corr C1-66
1716
Speaker
1 Corr C1-68
1717
Speaker
1 Corr C1-68
1718
Speaker
1 Corr C1-69
1719
Speaker
1 Corr C1-70
1720
Speaker
1 Corr C1-70
1721
Speaker
1 Corr C1-70
1722
Speaker
1 Corr C1-71
1723
Speaker
1 Corr C1-71
1724
Speaker
1 Corr C1-71`
1725
Speaker
1 Corr C1-72
1726
Speaker
1 Corr C1-72
1727
Speaker
1 Corr C1-72
1728
Speaker
1 Corr C1-73
1729
Speaker
1 Corr C1-73
1730
Speaker
1 Corr C1-73
1731
Speaker
1 Corr C1-75
1732
Speaker
1 Corr C1-75
1733
Speaker
1 Corr C1-75
1734
Speaker
1 Corr C1-76
1735
Speaker
1 Corr C1-77
1736
Speaker
1 Corr C1-79
1737
Speaker
1 Corr C1-79A
1738
Speaker
1 Corr C1-79A
1739
Speaker
1 Corr C1-80
1740
Speaker
1 Corr C1-80
1741
Speaker
1 Corr C1-82
1742
Speaker
1 Corr C1-82
1743
Speaker
1 Corr C1-83
1744
Speaker
1 Corr C1-83
1745
Speaker
1 Corr C1-84
1746
Speaker
1 Corr C1-84
1747
Speaker
1 Corr C1-87
1748
Speaker
1 Corr C1-88
1749
Speaker
1 Corr C1-90
1750
Speaker
1 Corr C1-92
1751
Speaker
1 Corr C1-95
1752
Speaker
1 Corr OS 1B125
1753
Speaker
1 Corr OS 1C101
1754
Speaker
1 Corr OS 1C130
1755
Speaker
1 Corr OS 1C138
1756
Speaker
1 Corr OS 1C139
1757
Speaker
1 Corr OS 1C140
1758
Speaker
1 Corr OS 1C-87A
1759
Speaker
1 Corr OS Center Stairs
1760
Speaker
1 Corr OS Center Stairs
1761
Speaker
1 Corr OS Comm Room 1A138
1762
Speaker
1 Corr OS R R 1C101A
1763
Speaker
1 Corr OS R R 1C135
1764
Speaker
1 Corr OS R R 1C135
1765
Speaker
1 Corr OS R R 1D105
1766
Speaker
1 Corr OS 1A101
1767
Speaker
1 Corr OS 1A104
1768
Speaker
1 Corr OS 1A108
1769
Speaker
1 Corr OS 1A110
1770
Speaker
1 Corr OS 1A118
1771
Speaker
1 Corr OS 1A119
1772
Speaker
1 Corr OS 1A126
1773
Speaker
1 Corr OS 1A127
1774
Speaker
1 Corr OS 1A129
1775
Speaker
1 Corr OS 1A134
1776
Speaker
1 Corr OS 1A136
1777
Speaker
1 Corr OS 1A146
1778
Speaker
1 Corr OS 1A148
1779
Speaker
1 Corr OS 1B147
1780
Speaker
1 Corr OS 1B160
1781
Speaker
1 Corr OS 1C107
1782
Speaker
1 Corr OS 1C113
1783
Speaker
1 Corr OS 1C116
1784
Speaker
1 Department Mail Room 1A133
1785
Speaker
1 Dining Area
1786
Speaker
1 Dining Area
1787
Speaker
1 Dining Area
1788
Speaker
1 Lobby East
1789
Speaker
1 Lobby East 1D160
1790
Speaker
1 Lobby East 1G102
1791
Speaker
1 Lobby East O S 1B112
1792
Speaker
1 Lobby East O S 1D100
1793
Speaker
1 Lobby East O S 1D102
1794
Speaker
1 Lobby East O S 1D143
1795
Speaker
1 Lobby East O S 1B106A
1796
Speaker
1 Lobby East O S 1B111
1797
Speaker
1 Lobby East O S 1B107
1798
Speaker
1 Lobby West 1G102
1799
Speaker
1 Lobby West By 1E131
1800
Speaker
1 Lobby West By 1E134
1801
Speaker
1 Lobby West By Corr C1-32
1802
Speaker
1 Lobby West O S 1E100
1803
Speaker
1 Operator Room 1B100
1804
Speaker
1 Pharmacy Waiting 1B112
1805
Speaker
1 Reception 1A132
1806
Speaker
1 Reception 1C131
1807
Speaker
1 Reception 1C175
1808
Speaker
1 Reception 1D102
1809
Speaker
1 Room 1A112
1810
Speaker
1 Room 1B117
1811
Speaker
1 Room 1B117
1812
Speaker
1 Room 1B118
1813
Speaker
1 Room 1B118
1814
Speaker
1 Room 1B120
1815
Speaker
1 Room 1B123
1816
Speaker
1 Room 1B124
1817
Speaker
1 Room 1B132
1818
Speaker
1 Room 1B134
1819
Strobe
1 Room 1B136
1820
Strobe
1 Room 1B138
1821
Strobe
1 Room 1B144
1822
Strobe
1 Room 1B155
1823
Strobe
1 Room 1B179
1824
Strobe
1 Room 1B179
1825
Strobe
1 Room 1B180
1826
Strobe
1 Room 1B180A
1827
Strobe
1 Room 1C101
1828
Strobe
1 Room 1E116
1829
Strobe
1 Room 1F156
1830
Strobe
1 Room 1F156
1831
Strobe
1 Room 1F156
1832
Strobe
1 Room 1F156
1833
Strobe
1 Room 1F156
1834
Strobe
1 Room 1F156
1835
Strobe
1 Seating Area 1B140
1836
Strobe
1 Waiting Area 1C100
1837
Strobe
1 Waiting Area 1C134
1838
Strobe
1 Waiting Area 1C174
1839
Strobe
1 Waiting Area 1C211
1840
Strobe
1 Waiting Area 1D100
1841
Strobe
1 Waiting Area 1E131
1842
Strobe
1 Waiting Area 1E134
1843
Strobe
1 Room 1C114
1844
Strobe
1 Room 1C116
1845
Strobe
1 Room 1C117
1846
Strobe
1 Room 1C119
1847
Strobe
1 Room 1C121
1848
Strobe
1 Room 1C122
1849
Strobe
1 Room 1C123
1850
Strobe
1 Room 1C124
1851
Strobe
1 Room 1C125
1852
Strobe
1 Room 1C126
1853
Strobe
1 Room 1C127
1854
Strobe
1 Room 1C128
1855
Strobe
1 Room 1C129
1856
Strobe
1 Room 1C133
1857
Strobe
1 Room 1C142
1858
Strobe
1 Room 1C143
1859
Strobe
1 Room 1C144
1860
Strobe
1 Room 1C145
1861
Strobe
1 Room 1C146
1862
Strobe
1 Room 1C147
1863
Strobe
1 Room 1C148
1864
Strobe
1 Room 1C149
1865
Strobe
1 Room 1C156
1866
Strobe
1 Room 1C161
1867
Strobe
1 Room 1C162
1868
Strobe
1 Room 1C162
1869
Strobe
1 Room 1C163
1870
Strobe
1 Room 1C164
1871
Strobe
1 Room 1C164
1872
Strobe
1 Room 1C165
1873
Strobe
1 Room 1C166
1874
Strobe
1 Room 1C167
1875
Strobe
1 Room 1C168
1876
Strobe
1 Room 1C170
1877
Strobe
1 Room 1C171
1878
Strobe
1 Room 1C172
1879
Strobe
1 Room 1C178
1880
Strobe
1 Room 1C179
1881
Strobe
1 Room 1C180
1882
Strobe
1 Room 1C181
1883
Strobe
1 Room 1C182
1884
Strobe
1 Room 1C183
1885
Strobe
1 Room 1C184
1886
Strobe
1 Room 1C185
1887
Strobe
1 Room 1C187
1888
Strobe
1 Room 1C189
1889
Strobe
1 Room 1C192
1890
Strobe
1 Room 1C193
1891
Strobe
1 Room 1C196
1892
Strobe
1 Room 1C197
1893
Strobe
1 Room 1C198
1894
Strobe
1 Room 1C199
1895
Strobe
1 Room 1C200
1896
Strobe
1 Room 1C201
1897
Strobe
1 Room 1C202
1898
Strobe
1 Room 1C203
1899
Strobe
1 Room 1C204
1900
Strobe
1 Room 1C205
1901
Strobe
1 Room 1D144
1902
Strobe
1 Room 1D164
1903
Strobe
1 Room 1D165
1904
Strobe
1 Room 1D166
1905
Strobe
1 Room 1D166
1906
Strobe
1 Room 1D167
1907
Strobe
1 Room 1D168
1908
Strobe
1 Room 1D169
1909
Strobe
1 Room 1D170
1910
Strobe
1 Room 1D171
1911
Strobe
1 Room 1E101
1912
Strobe
1 Room 1E103
1913
Strobe
1 Room 1E104
1914
Strobe
1 Room 1E105
1915
Strobe
1 Room 1E106
1916
Strobe
1 Room 1E107
1917
Strobe
1 Room 1E108
1918
Strobe
1 Room 1E109
1919
Strobe
1 Room 1E110
1920
Strobe
1 Room 1E112
1921
Strobe
1 Room 1E120
1922
Strobe
1 Room 1E122
1923
Strobe
1 Room 1E123
1924
Strobe
1 Room 1E124
1925
Strobe
1 Room 1E126
1926
Strobe
1 Room 1E127
1927
Strobe
1 Room 1E128
1928
Strobe
1 Room 1E128
1929
Strobe
1 Room 1E136
1930
Strobe
1 Room 1E137
1931
Strobe
1 Room 1E138
1932
Strobe
1 Room 1E139
1933
Strobe
1 Room 1E140
1934
Strobe
1 Room 1E143
1935
Strobe
1 Room 1E144
1936
Strobe
1 Room 1E145
1937
Strobe
1 Room 1E147
1938
Strobe
1 Room 1E148
1939
Strobe
1 Room 1E149
1940
Strobe
1 Room 1E150
1941
Strobe
1 Room 1F114
1942
Strobe
1 Room 1F145
1943
Strobe
1 Room 1F146
1944
Strobe
1 Room 1F148
1945
Strobe
1 Room 1F149
1946
Strobe
1 Room 1F152
1947
Strobe
1 Room 1F153
1948
Strobe
1 Room 1F155
1949
Strobe
1 Room 1B150
1950
Strobe
1 Room By Main FACP
1951
Strobe
1 Room 1C113
1952
Strobe
1 Room R R 1A139
1953
Strobe
1 Room R R 1B107
1954
Strobe
1 Room R R 1B131
1955
Strobe
1 Room R R 1C101A
1956
Strobe
1 Room R R 1C106
1957
Strobe
1 Room R R 1C120
1958
Strobe
1 Room R R 1C135
1959
Strobe
1 Room R R 1C136
1960
Strobe
1 Room R R 1C138
1961
Strobe
1 Room R R 1C139
1962
Strobe
1 Room R R 1C150
1963
Strobe
1 Room R R 1C152
1964
Strobe
1 Room R R 1C160
1965
Strobe
1 Room R R 1C186
1966
Strobe
1 Room R R 1C195
1967
Strobe
1 Room R R 1C206
1968
Strobe
1 Room R R 1C207
1969
Strobe
1 Room R R 1C209
1970
Strobe
1 Room R R 1C210
1971
Strobe
1 Room R R 1D105
1972
Strobe
1 Room R R 1D106
1973
Strobe
1 Room R R 1D107
1974
Strobe
1 Room R R 1D108
1975
Strobe
1 Room R R 1D113
1976
Strobe
1 Room R R 1D126
1977
Strobe
1 Room R R 1D129
1978
Strobe
1 Room R R 1D140
1979
Strobe
1 Room R R 1D141
1980
Strobe
1 Room R R 1D145
1981
Strobe
1 Room R R 1D151
1982
Strobe
1 Room R R 1D173
1983
Strobe
1 Room R R 1E116
1984
Strobe
1 Room R R 1E117
1985
Strobe
1 Room R R 1E118
1986
Speaker/Strobe
1 Room R R 1E119
1987
Speaker/Strobe
1 Room R R 1E142
1988
Speaker/Strobe
1 Room R R 1E151
1989
Speaker/Strobe
1 Room R R 1E153
1990
Speaker/Strobe
1 Room R R 1E154
1991
Speaker/Strobe
1 Room R R 1E155
1992
Speaker/Strobe
1 Room R R 1F103
1993
Speaker/Strobe
1 Room R R 1F107
1994
Speaker/Strobe
1 Room R R 1F115
1995
Speaker/Strobe
1 Room R R 1F136
1996
Speaker/Strobe
1 Room 1A133
1997
Speaker/Strobe
1 Room 1B135
1998
Speaker/Strobe
1 Room 1B137
1999
Speaker/Strobe
1 Room 1B144
2000
Speaker/Strobe
1 Room 1C101
2001
Speaker/Strobe

This is the start of the file's text. The full file is on GovTribe.