Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice

SUBJECT*
667-22-2-502-0169, Facility Domestic & Fire Water Pipe Repair/Support (VA-22-00037537)

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
39157
SOLICITATION NUMBER*
36C25622Q0460
RESPONSE DATE/TIME/ZONE
03-08-2022 10:00 CENTRAL TIME, CHICAGO, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
4510
NAICS CODE*
238220
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

G.V. (Sonny) Montgomery VAMC

715 S. Pear Orchard Ridgeland, MS 39157

POINT OF CONTACT*

Marcia Stewart marcia.stewart1@va.gov

PLACE OF PERFORMANCE

ADDRESS
Overton Brooks VA Medical Center

510 Stoner Avenue

Shreveport LA

POSTAL CODE
71101

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

See attached document: Combined Synopsis-1646.

See attached document: 36C25622Q0460-1646.

STATEMENT OF WORK

Pipe Replacement Restraint and Support

The Contractor shall furnish all labor, materials, tools, and equipment necessary to repair/restrain 10-inch water piping joints located in the sub-basement crawlspace of building 1, Overton Brooks VA Medical Center, 510 E. Stoner Avenue, Shreveport, LA in accordance with all terms, conditions, provisions, schedules, and specifications of this statement of work.

Scope of Work RRAC will make repairs to 10-inch domestic water line at leaking joint in sub-basement crawlspace. Pipe will need to be repaired at location of leak in order to seal which will need repair clamps as well as restraints. Restrain only all joints on the existing 10-inch domestic and fire mains located in the sub-basement crawlspace. Also block and change 10-inch MJ quarter bend that blew out at joint. This would be approximately 40 locations to restrain and build sway brackets to hold the piping in line while operational.

Additional guidance

· All work activities during this work shall be authorized by the COR. All work shall be in accordance with the Statement of Work (SOW).

· Contractor shall adhere to the schedule for all work outlined in the Statement of Work (SOW) and established by the COR.

· Contractor shall always ensure the safety and protection of VA staff, equipment, and property.

· Contractor shall ensure all OSHA and VA safety precautions are in place before, during & after work.

· Prior to start of work, the contractor shall coordinate with the COR date(s) of repair.

· The C&A requirements do not apply, and a Security Accreditation Package is not required for this procurement.

· All work will be performed during hours scheduled with the COR.

The following are federal holidays:

New Year’s DayLabor Day
Martin Luther King Jr.’s BirthdayColumbus Day
President’s DayVeteran’s Day
Memorial Day
Juneteenth National Independence DayThanksgiving Day
Independence DayChristmas Day

See attached document: Wage Determinination-1646.

See Attached Combined Synopsis/Solicitation

End of Document