This document is a sources sought notice from the Department of Veterans Affairs seeking information from capable contractors to provide water quality testing services for the G.V. (Sonny) Montgomery VA Medical Center in Jackson, Mississippi. The notice specifies that the contractor shall provide quarterly Legionella and monthly, quarterly, and annual Sterile Processing Service validation testing in accordance with the stated specifications, and report results through an existing web-based data management system. Responses are due by November 12, 2020 and shall include capabilities statements, DUNS numbers, and whether the requirement is on GSA/FSS schedule or open market. The NAICS code is 541620 for environmental consulting services with a size standard of $16.5 million. Preferably, service-disabled veteran-owned small businesses or small businesses will be considered for this requirement.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract Opportunity Sources Sought Notice
PRODUCT SERVICE CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE/TIME/ZONE
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field Contract Opportunity Sources Sought Notice H199 Water Quality Testing Service 39216 36C25621Q0162 11-12-2020 2:00pm
CENTRAL TIME, CHICAGO, USA
N 541620 Department of Veterans Affairs G.V. (Sonny) Montgomery VAMC 1500 E. Woodrow Wilson Dr.
Jackson MS 39216 Department of Veterans Affairs G.V. (Sonny) Montgomery VAMC 1500 E. Woodrow Wilson Dr.
Jackson
MS
39216
USA
jennifer.adams7@va.gov This is a SOURCES SOUGHT NOTICE ONLY.
This SOURCE SOUGHT NOTICE is for the purpose of Market Research. Response to this notice will be used for information and planning purposes. No proposals or quotes are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS or QUOTES and NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall NOT be construed as solicitation or as an obligation on the part of the Department of Veterans Affairs (VA). Responses to this notice is not a request to be added to a prospective bidders list or to receive a copy of the solicitation.
The Network Contracting Office (NCO) 16 is seeking preferably Service-Disabled Veteran Owned Small Businesses, or Small Businesses (but will accept other than small business for market research purposes), capable of performing water quality testing service for the G.V. (Sonny) Montgomery VAMC, Jackson, MS.
See Statement of Work for detailed description of services.
The NAICS code is 541620 Environmental Consulting Services and the Size Standard is $16.5M. Responses must be received by no later than 2:00pm Central Time, Thursday, November 12, 2020. Responses shall be emailed to jennifer.adams7@va.gov . Responses shall include Capabilities Statements, DUNS number, and whether the requirement is on GSA/FSS schedule or Open Market. Facsimile or Telephonic responses will not be accepted.
Note: All interested parties are reminded to be registered, active and verified in the following to be considered for Award.
· SAM: https://sam.gov/SAM/
· VETBIZ: https://www.vip.vetbiz.va.gov/
· Vet 4212 (Veteran owned small Business are reminded of Reporting Requirements) https://www.dol.gov/agencies/vets/progams/vets4212
STATEMENT OF WORK (SOW)
WATER QUALITY TESTING SERVICES
G.V. (SONNY) MONTGOMERY VA MEDICAL CENTER
JACKSON, MS 39216
The contractor shall provide validation testing and report results in the existing Web-based Data Management System in alignment with the requirements of VHA Directive 1061, VHA Directive 1116(2), and AAMI TIR 34: 2014/(R)2017.
Validation Testing
• The contractor shall provide quarterly Legionella validation testing in accordance with the Specifications to ensure that the hazards are controlled as identified in the Water Management Program.
• The contractor shall provide monthly, quarterly, and annual Sterile Processing Service validation testing in accordance with the Specifications to ensure that the hazards are controlled as identified in the Water Management Program.
Web-based Data Management System
• The contractor shall use the existing Web-based Data Management System in accordance with the Specifications to collect, analyze, and store data collected. It will store WMP documents, verification activities, corrective actions, and validation test results in addition to data recorded from Portable Water Analyzer (PWA) systems.
SPECIFICATIONS
1. Validation Testing The contractor will provide all labor, materials, and equipment necessary to complete environmental Validation Testing of the water systems.
The contractor’s laboratory must have a certificate of proficiency from the Centers for Disease Control and Prevention (CDC) Environmental Legionella Isolation Techniques Evaluation (ELITE) program. In addition, the laboratory must have environmental microbiology accreditation by a nationally recognized accrediting body, such as EMLAP, NELAP, etc.
Legionella Testing Legionella environmental testing shall occur at a minimum of once per Federal fiscal year quarter. The laboratory will provide a report indicating the analytical results for each sample submitted. Results will be calculated in terms of colony forming units (CFU/mL). All samples shall be properly preserved and protocol records kept for final QA/QC. Results shall be provided within 10-14 days of sample receipt and shall be immediately uploaded into the web-based data management site and emailed in PDF format to the Contracting Officer Representative (COR).
The contractor shall collect water samples for testing from two (2) buildings (Bldg. 1 Main Hospital; Bldg. 7 Community Living Center). Sample sources are 10 outlets on the hot-water distribution system and 10 outlets on the cold-water distribution system from each building (or a total of 40 samples per quarter and 160 samples per year) and one (1) cooling tower water sample for each quarterly testing cycle. At the time of sampling, the contractor shall test and document the following for each sample: water temperature, level of residual biocide, and pH. The laboratory shall use Legionella 11731 ISO spread plate method for Legionella pneumophila and non-pneumophila species
• Measures L. pneumophila serogroup 1, L. pneumophila serogroup 2-14, and non-pneumophila species
• Inoculated at the laboratory – overnight shipment recommended
• Limit of Detection (CFU/ml) = 1*
• Reports: 10 days after laboratory receives samples
Sterile Processing Service Testing The contractor shall collect samples from five (5) critical water sources and seven (7) utility water sources in accordance with approved laboratory procedures. The contractor shall furnish appropriate shipping containers and shipping labels for the transportation of samples to the laboratory. The laboratory will follow strict chain of custody procedures upon the receipt of the samples.
Validation testing shall occur at the frequencies identified in the table below for each test. The laboratory will provide a report indicating the analytical results for each sample submitted. Results shall be provided within 10 days of sample receipt and shall be immediately uploaded into the web-based data management site and emailed in PDF format to the Contracting Officer Representative (COR). Lower limits of detection will align with AAMI TIR 34: 2014/(R)2017 recommended levels of water quality for medical device reprocessing.
| Frequency |
| Test Panels |
| Monthly |
| SPS Water Quality Panel-Monthly |
· Bacteria - Heterotrophic Plate Count (Spread Plate)
· Total Organic Carbon (TOC)
· pH
· Conductivity (for Resistivity)
· Color
· Turbidity
| Quarterly for one year until 4 consecutive quarters within limits, then Annual |
| SPS Water Quality Panel - Annual |
· Hardness (Total)
· Ionic Contaminants
· Chloride
· Iron
· Copper
· Manganese
| Varies* |
| LAL/Endotoxin |
* Endotoxin frequency is identified by occasion per AAMI TIR 34: 2014/(R)2017: On installation, modification, or repair of the critical water treatment system or when persistent increased microbial levels are detected by heterotrophic plate count, ATP, or TOC. To simplify, the testing frequency of this parameter will align with the annual testing panel (Quarterly for one year until 4 consecutive quarters within limits, then Annual), but the VA may choose to test less frequently.
Non-Routine Testing Upon request, retesting after remediation or other non-routine testing will be performed at the request of the Contracting Officer Representative (COR). Should the quantity listed in the price schedule be exceeded, additional funds may be provided to do additional tests.
2. Web-based Data Management System The web-based data management system shall provide the following functions:
• All information stored in the system is available 24/7 via password-protected access
• WMP-related reports (including validation testing results, meeting minutes, verification reports, and service provider reports) can be stored and available for immediate access by all users
• Customized charts, reports, views, and data entry screens as requested
• Management dashboards with industry benchmarking
• Send text or email alerts for data that is outside of set parameters
• Data collection via tablets and other hand-held devices
• Automated data collection via continuous monitoring equipment (equipment not included)
• Validation test results immediately uploaded into the phiAnalytics site (if samples are analyzed by Phigenics)
• Exportable data to excel and other formats Qualifications.
The contractor selected to perform this work must be an independent provider of water management services engaged in the development and ongoing management of facility and corporate water management programs. To be deemed “independent” and thus avoid commercial conflict of interest, neither the prime contractor nor any partners, subcontractors nor subsidiary companies may sell treatment chemicals, disinfection devices, or remediation services. The sale of water testing services and diagnostic equipment related to determining the safety and quality of the water does not void independence.
The laboratory must have a certificate from the Centers for Disease Control and Prevention (CDC) Environmental Legionella Isolation Techniques Evaluation (ELITE) Program as proficient at performing the culture of Legionella from environmental samples. The laboratory must also have environmental microbiology accreditation by a nationally recognized accrediting body (e.g., EMLAP, NELAP).
End of Document