36C25527R0020_1.docx

DOCX document 19 KB Posted

Attached to
Z2DA--657-27-103JB, FCA Replace Building 51 Roof
Solicitation number
36C25527R0020
Issued by

About this file

This is a Presolicitation Notice for a construction project to replace the roof of Building 51 at the St. Louis Veterans Affairs Medical Center (VAMC) Jefferson Barracks facility. The Department of Veterans Affairs, Network Contracting Office (NCO) 15, is seeking to contract complete construction services to replace approximately 56,000 square feet of designated roofing on Building 51, including projections, entrance roofs, and connecting portions. The project requires installation of a watertight thermoplastic polyolefin (TPO) roofing system in accordance with VA-prepared drawings and specifications, with an estimated project cost range between $2,000,000 and $5,000,000. The work is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under 38 USC 8127(d), with NAICS code 236220 (Commercial and Institutional Building Construction) and a small business size standard of $45.0 million.

The scope includes hazardous materials investigation, selective demolition and removal of existing roofing assemblies, installation of mechanically fastened rigid insulation and fully adhered TPO roofing membrane, replacement of four skylights, roof drain reconfiguration, correction of drainage deficiencies, temporary removal and reinstallation of the lightning-protection system, and replacement of the penthouse roof-access ladder. The contractor must maintain safe access and building operations throughout the 222-calendar-day performance period, as Building 51 operates 24/7. Work is restricted to 7:00 a.m. to 4:30 p.m. local time, and the contractor must submit a phasing plan for VA approval prior to commencing work. The solicitation package should be available for download on or about December 7, 2026, with proposals due on or about January 15, 2027. An organized site visit will be scheduled; only one visit will be held and attendance is strongly encouraged. The contract award will be made using a "Highest technically rated with a fair and reasonable price" approach under Federal Acquisition Regulation Part 15, with award anticipated without discussions. All prospective contractors must be registered in both SAM and the Veteran Small Business Certification databases. Contact is Jennifer Hill, Contracting Officer, at Jennifer.Hill@va.gov or 913-946-1198; email inquiries must include the specific project and solicitation number in the subject line.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice Presolicitation Notice

SUBJECT*
657-27-103JB, FCA Replace Building 51 Roof

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
66048
SOLICITATION NUMBER*
36C25527R0020
RESPONSE DATE/TIME/ZONE
12-07-2026 16:00 CENTRAL TIME, CHICAGO, USA
ARCHIVE
15 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
Z2DA
NAICS CODE*
236220
PLACE OF PERFORMANCE
St. Louis VAMC

Jefferson Barracks

1 Jefferson Barracks Drive

St. Louis MO

POSTAL CODE
63125

COUNTRY

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway

USA

Leavenworth KS 66048

POINT OF CONTACT*

Contracting Officer Jennifer Hill Jennifer.Hill@va.gov 913-946-1198

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Project # 657-27-103JB, FCA Replace Building 51 Roof

The Department of Veterans Affairs, Network Contracting Office (NCO) 15, has a requirement to Replace Building 51 Roof, project number 657-27-103JB, located at the U.S Department of Veterans Affairs, Str. Louis VAMC Jefferson Barracks 1 Jefferson Barracks Drive St. Louis, MO 63125 The following narrative is intended to provide an overview of the scope of work for the proposed project.

Period of Performance 222 calendar days after Notice to Proceed (NTP) Scope of Work Furnish complete construction services to replace all designated Building 51 roofs, including projections, entrance roofs, and connecting portions. The preliminary net roof area is approximately 56,000 square feet, subject to field verification. Provide a watertight thermoplastic polyolefin (TPO) roofing system in accordance with the VA-prepared drawings and specifications. Contractor shall submit shop drawings, product data, and installation details for all proposed materials, equipment, and systems to be installed or replaced under this contract for VA review prior to commencing the associated work. Submittals shall include applicable manufacturer's specifications and required engineering certifications.

Schedule, phasing, and occupied operations: Complete construction and closeout within 222 calendar days after the Notice to Proceed issue date. Building 51 remains occupied and operational 24 hours per day, seven days per week. Work hours are from 7:00 a.m. to 4:30 p.m., local time. Submit a contractor-developed phasing plan for the Contracting Officer's Representative (COR) to review before roofing. Complete both highest penthouse roof platforms first on the original building and the highest roof section first on the addition; either building portion may be started first. Maintain safe access, utilities, and required infection-control and HVAC-intake protection. Provide construction fall protection and keep the building watertight; coordinate service interruptions with the VA.

Investigation and Roofing Requirements:

a. Hazardous Materials: While neither Asbestos Containing Material nor Lead is expected to be encountered within the scope of this project, it will be the responsibility of the contractor to hire an independent 3rd party VPIH to complete the related work if they are to encounter a material that they deem suspicious.

b. Demolition limit: At the original building (Zones 1-7, 13, and 14), remove the existing roofing assembly through the base sheet to the top of the Zonolite lightweight-concrete topping; retain the topping and underlying structural concrete deck. At the addition (Zones 8-12 and 15), remove the existing roofing assembly, including insulation and intervening layers, to the top of the metal roof deck; retain the deck and supporting structure. Clean and inspect retained surfaces, and repair deterioration within specified repair limits. Report differing construction or deterioration beyond those limits to the COR before proceeding with affected work.

c. New roof and mechanical securement: Install mechanically fastened rigid insulation, adhered cover board, and fully adhered 70-mil TPO roofing membrane with continuous hot-air-welded seams. Contractor shall verify that the proposed fastening system is compatible with Building 51's existing roof construction.

d. Parapets, penetrations, and retained metal: Extend new roofing up parapets to the existing flashing. Flash and seal, with the correct system specific boots, all roof penetrations with compatible membrane extending at least 8 inches above the finished roof, or higher where required by applicable VA criteria and manufacturer/warranty requirements. Retain metal flashings, flanges, and coping unless scheduled for replacement, and replace roofing beneath retained metal.

Specific Replacement and Repairs:

e. Associated roof work: Retain rooftop HVAC units in place and replace roofing beneath elevated units and frames and around curbs. Replace old or deteriorated wooden rooftop support blocks with load-rated black rubber blocks compatible with the roofing; retain serviceable recently replaced blocks. Replace roof-drain covers/strainers and recondition retained drains with watertight connections. Reflash existing scuppers and provide new scuppers only where detailed; retain gutters and downspouts unless otherwise indicated. Correct approximately 250 square feet of depressed roof on the original building's middle section north of the penthouse to provide positive drainage. Replace expansion-joint weatherproofing/cover material at two original-building sections, approximately 40 linear feet each. Temporarily remove and reinstall the existing lightning-protection system in its original locations and configuration with new clips securing it; complete specified testing and certification. Repair approximately 150 linear feet of the existing movable stanchion-and-rope warning-line barrier. Replace the penthouse roof-access ladder to meet applicable VA safety requirements and OSHA criteria. Install 3-foot by 3-foot walking pads with 8-inch clear gaps along approximately 600 linear feet of total walkway route, including gaps. Provide positive drainage to roof drains and scuppers throughout all reroofed areas. Standing water shall not remain more than 48 hours after rainfall ends under conditions conducive to drying. Correct low spots and other drainage deficiencies that prevent compliance before final acceptance.

f. Skylights: Replace four skylights: two approximately 85 square feet each and two approximately 40 square feet each. Field-verify openings and provide complete watertight installations. Before fabrication, submit contractor shop drawings and supporting structural calculations signed and sealed by a licensed structural engineer responsible for their design/review.

g. Submittals, record drawings, and closeout: Provide required construction submittals and complete specified testing, inspections, and closeout. Submit a clean, coordinated as-built record drawing set in searchable PDF and editable CAD showing actual installed conditions and accepted changes; redline markups alone are not acceptable. Provide a 20-year no-dollar-limit (NDL) warranty and maintenance information, complete cleanup and restoration, and comply with contract records-management, privacy, and security requirements.

The estimated project cost range to complete this work is Between $2,000,000 and $5,000,000.

Pursuant to 38 USC 8127(d) and in accordance with Public Law 109-461, the Veterans Benefits, Health Care and Information Technology Act of 2006, this construction project will be solicited as a Total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB).

The North American Industry Classification Code (NAICS) for this procurement is 235220 Commercial and Institutional Building Construction, with a small business size standard of $45.0 million.

Contract Type: Firm Fixed. The duration of the project is estimated to be 210 calendar days from Notice to Proceed. This completion period includes final inspection and cleanup of the premises.

Award will be made utilizing Highest technically rated with a fair and reasonable price approach in accordance with Federal Acquisition Regulation Part 15.

Proposal submission instructions will be included in the solicitation package.

The government plans to award without discussions.

The offeror is responsible to monitor and download any amendments from the Contract Opportunities (https:// sam.gov) website, which may be issued to this solicitation.

In accordance with FAR 52.204-7, Required SAM, and in accordance with Veterans Affairs Acquisition Regulation (VAAR) 802.101, prospective contractors must be registered in SAM and in the Veteran Small Business Certification (sba.gov) databases under the applicable NAICS.

Firms may obtain SAM information at http://www.sam.gov and Veteran Small Business Certification (sba.gov) information at https://veterans.certify.sba.gov The solicitation package with project specifications and drawings should be available for download on or about December 7, 2026 and the proposal due date will be on or about January 15, 2027. An organized site visit will be scheduled and specific date and time will be made available at time of solicitation issuance. Only one site visit will be scheduled and interested offerors are highly encouraged to attend. No hard copies of the solicitation or drawings will be provided; and telephone requests or questions will NOT be accepted.

Please email requests or questions to Jennifer.Hill@va.gov and ensure that the subject line reads "FCA Replace Building 51 Roof, Project Number 657-27-103JB; Solicitation Number: 36C25527R0020.

*=Required Field
Presolicitation Notice

Presolicitation Notice