36C25524R0013 0002.docx
DOCX document 17 KB Posted
- Solicitation number
- 36C25524R0013
About this file
This document provides an amendment to a previous combined solicitation for architectural and engineering services. The solicitation seeks qualified firms to replace mechanical systems in Building 52 at the St. Louis Jefferson Barracks VA Medical Center located at 1 Jefferson Barracks Road in St. Louis, Missouri. Responses are due by December 5, 2023 at 10:00 AM Central Time.
The amendment replaces the evaluation factors to focus on the qualifications of individuals and teams, specialized experience and technical competence in same-day access clinics and VA medical facility renovations, capacity to accomplish the work within required timelines, past performance on relevant projects in the past three years, and location of the design firm within 500 miles of the medical center. At least 50% of the design work must be performed by employees of the prime contractor or eligible SDVOSB subcontractor/consultant.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25524R0013 0001.docx | DOCX document | |
| 36C25524R0013.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amendment to a Previous Combined Solicitation
Amendment to a Previous Combined Solicitation
| SUBJECT* |
| 657-24-106JB FCA – Replace Mechanical Systems in Building 52 |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 66048 |
| SOLICITATION NUMBER* |
| 36C25524R0013 |
| RESPONSE DATE/TIME/ZONE |
| 12-05-2023 10:00 CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| C1DA |
| NAICS CODE* |
| 541330 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway
Leavenworth KS 66048
POINT OF CONTACT*
Contract Specialist Jennifer Sotomayor Jennifer.Sotomayor@va.gov 913-946-1144
PLACE OF PERFORMANCE
| ADDRESS |
| St. Louis Jefferson Barracks |
1 Jefferson Barracks Drive
St. Louis MO
| POSTAL CODE |
| 63125 |
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
The evaluation factors are replaced as follows.
1. Professional Qualifications: the qualifications of the individuals which will be used for these services will be examined for experience and education and their record of working together as a team. AE firms shall have professional architects, engineers, and consultants who are licensed in the United States of America. License information must be provided. The specific disciplines which will be evaluated are:
Architects, Project Managers, Engineers (to include Electrical, Mechanical, and Fire Protection), and Estimators.
2. Specialized Experience and Technical Competence: specific experience and technical skill in the type and scope of work required for successful design of same-day access clinic for the mental health service line VA medical facilities, redesign of existing space into multiple exam rooms and reception area, and familiarity with VHA directive 1231(2) and VHA handbook 1160.1 and all related requirements. Additionally, experience with renovations and new construction at existing medical facilities, including, where appropriate, renovating space for patient privacy and rehabilitation services, energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team.
3. Capacity to Accomplish the Work: The general workload and staffing capacity of the design office which will be responsible for the majority of the design and the ability to accomplish the work in the required time will be evaluated. In accordance with VAAR 852.219-10(c)(1), prime contractors shall clearly demonstrate how they will meet the requirement that at least 50 percent of the design work be accomplished by employees of the concern or employees of eligible service-disabled veteran owned small business subcontractor/consultant.
4. Past performance: the past performance of projects that are complete (design and construction) that the firm has designed relevant in scope to the advertised project that were accomplished with the Department of Veterans Affairs, other Government agencies, and private industry in terms of cost control, quality of work, and compliance with performance schedules will be examined. Point of Contact information must be provided so past performance can be verified. Project past performances that are older than 3 years will receive a lesser score than those references for projects accomplished within the past 3 years.
5. Location of Design Firm: Per FAR 36.602-1 Selection Criteria: Market research indicates that at least 3 qualified firms exist within a 500 mile radius of the St. Louis Jefferson Barracks VA Medical Center located at 1 Jefferson Barracks Rd, Saint Louis, MO 63125. Architectural Prime Contractors whose physical business address is within a 500 mile radius from the St. Louis Jefferson Barracks VA Medical Center located at1 Jefferson Barracks Rd, Saint Louis, MO 63125 and resides within the borders of the United States of America will receive a higher score on evaluations.
Architectural Prime Contractors whose physical business address is outside a 500 mile radius from the St. Louis Jefferson Barracks VA Medical Center located at 1 Jefferson Barracks Rd, Saint Louis, MO 63125 and resides within the borders of the United States of America will receive a lesser score on evaluations.
Architectural Prime Contractors are required to verify the primary physical business address (described above) as part of the SF330 response. If the information cannot be verified as required, the SF330 will be found to be nonresponsive and will not receive further consideration.
SF 330 submissions from companies located outside the borders of the United States of America shall not be considered.
6. Claims and Terminations: record of significant claims against the firm or terminated contracts because of improper or incomplete architectural and engineering services will be examined.
| *= Required Field |