This document contains a federal contract opportunity and related modification notice for architectural and engineering services. The Department of Veterans Affairs is seeking proposals by October 20, 2022 for design of a centralized chilled water plant and associated infrastructure at the Robert J. Dole VA Medical Center in Wichita, Kansas. The estimated $27.5 million contract will be awarded as a 100% service-disabled veteran-owned small business set-aside. The selected firm must complete final construction documents within 385 calendar days of the notice to proceed and provide Revit models, 2D drawings, and secure file sharing throughout the project. Proposals exceeding 50 pages will be deemed non-responsive. Evaluation criteria include professional qualifications, experience, capacity, past performance, and location within 500 miles of the medical center.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25522R0108.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Modification to a Previous Notice Modification to a Previous Notice
| SUBJECT* |
| 589A7-21-131, TF - Construct Centralized Chilled Water Plant & Associated Infrastructure and Controls |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 66048 |
| SOLICITATION NUMBER* |
| 36C25522R0108 |
BASE NOTICE TYPE
| RESPONSE DATE/TIME/ZONE |
| 10-20-2022 2:00PM CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 90 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| C1EB |
| NAICS CODE* |
| 541330 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway
Leavenworth KS 66048
POINT OF CONTACT*
Contracting Officer Sean Jackson sean.jackson@va.gov 913-946-1126
PLACE OF PERFORMANCE
ADDRESS
POSTAL CODE
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
| AGENCY CONTACT’S EMAIL ADDRESS |
| sean.jackson@va.gov |
| EMAIL DESCRIPTION |
| Sean Jackson |
DESCRIPTION
Amendment 001 to Request for SF330 36C25522R0108:
The request for SF330’s from eligible Architect/Engineering firms for Project 589A7-21-131 – Construct Centralized Chilled Water Plant and Associated Infrastructure and Controls Systems is amended as follows:
1. All references to kitchen design are removed from the requirement.
2. Architectural Prime Contractors whose primary (i.e. headquarters, primary corporate office, main office) physical business address is within a 1,000 mile radius from the Wichita VA Medical Center located at 5500 E. Kellogg, Wichita Kansas 67218 and resides within the borders of the United States of America may receive a higher score on evaluations.
3. Architectural Prime Contractors whose primary physical business address is outside a 1,000 mile radius from the Wichita VA Medical Center located at 5500 E. Kellogg, Wichita Kansas 67218 and resides within the borders of the United States of America may receive a lesser score on evaluations.
4. Architectural Prime Contractors are required to verify the primary physical business address (described above) as part of the SF330 response. If the information cannot be verified as required, the SF330 will be found to be nonresponsive and will not receive further consideration.
5. SF 330 submissions from companies located outside the borders of the United States of America shall not be considered.
6. SF330 submission packages which exceed 50 pages will be considered non-responsive and shall be excluded from further consideration. The only exclusions to the 50 page limit as listed in the solicitation are: table of contents, title page, and divider pages. Title page shall not exceed more than one (1) page. Table of contents shall only contain the information necessary to define the contents of the document. Divider pages may contain a maximum of one (1) line of description. All other conditions required are in the original posting of 36C25522R0108.