5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 36C255 Department of Veterans Affairs Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway Leavenworth
KS
66048 36C255 Department of Veterans Affairs Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway Leavenworth
KS
66048 To all Offerors/Bidders
36C25521Q0437 06-17-2021
X X X
11:00 PM, 7/5/2021
The purpose of this modification is to modify the Statementof Work and add a document with the hood model and serial numbers.
1. The Statement of work is updated to remove the words: Clean Rooms and Barrier Isolators
2. A document has been added listing the hood and cabinet model and/or serial numbers
3. The closing date of this solicitation has been amended to end on 7/5/21 at 23:00
4. All contract clauses and provisions remain unchanged.
HOOD CERTIFICATION/MAINTENANCE
STATEMENT OF WORK - RESEARCH SERVICE
589-21-3-8101-0282
1. The C&A Requirements do not apply and a Security Accreditation Package is not required.
2. Contractor shall provide all parts, tools, test equipment, software, labor, travel and equipment necessary to provide inspections, perform preventive maintenance (including cleaning) and certifications of Chemical Fume Hoods, Class II Biological Safety Cabinets (Type A and Type B), and Laminar Flow Units in Research Service at the Kansas City VA Medical Center. This work shall be accomplished on a semi-annual basis.
3. Contractor shall ensure that equipment services by this contract functions in compliance with the most up-to-date published edition of the applicable standards including the NSF 49, ANSI/SEFA, ASHRAE 110, USP 797, CETA CAG-002, NIH EPA, JCAHO, UL, OSHA, CDRH and VA standards. The contractor will be responsible to ensure that Contractor Employees providing work on this contract are fully trained, NSF accredited and completely competent to perform the required work. Equipment used in performance of the contract by Contractor Employees will function in conformance with the latest published edition of the applicable standards including the NSF 49, ANSI/SEFA, ASHRAE 110, USP 797, CETA CAG-002, NIH EPA, JCAHO, UL, OSHA, CDRH and VA standards. All equipment tested shall be properly labeled/tagged after certification completion prior to leaving site.
4. Semi-Annual on site certifications for Biological Safety Cabinets (BSCs) must be accomplished in accordance with the most current National Sanitation Foundation/ American National Standards Institute (NSF/ANSI) Standard 49 Class II (laminar flow) Biosafety Cabinetry. The list of tests includes, but is not limited to:
a. Downflow Velocity and Volume Test
b. HEPA filter leak test
c. Cabinet leak test
d. Inflow velocity test to include exhaust airflow volume rate
e. Airflow Smoke pattern test
f. Electrical leakage and ground circuit resistance and polarity tests
g. Lighting intensity test
h. Vibration test
i. Noise level test
j. Ultraviolet (UV) lamp test Laminar Flow Unit Certifications must be accomplished in accordance with the most current version of the National Sanitation Foundation/American National Standards Instituted (NSF/ANSI) Standard 49 class II Bio-Safety Cabinet.
Fume hoods certifications must be accomplished in accordance with the most current version of the American Conference of Government Industrial Hygienists (ACGIH), Industrial Ventilation: A Manual of Recommended Practice.
Halogen Leak Test must be performed in accordance with VHA Handbook 1106.1 “Pathology and Laboratory Medicine Service Procedures”. A copy of the handbook may be found at https://www1.va.gov/vhapublications/ViewPublication.asp?pub_ID=1779
5. Contractor Check-in – The contractor’s representative will schedule all work for Research Service in conjunction with the work done for the Kansas City VA Hospital Facilities. Contractor’s representative will contact the Budget Analyst in Research at 816-861-4700 ext 57062 or 52755 prior to performance of the services. Contractor will report all issues to the Contracting Officer’s Technical Representative (COTR) for Research Service while performing work for Research Service Kansas City VA Medical Center. The contractor must furnish a detailed field service report or equivalent showing work completed, listing all repairs and/or repair parts used to maintain operating efficiency of the equipment. This report must be delivered to the COTR (or designee) as the contractor signs out and leaves the facility or sent via email within 3 business days. Payment will be withheld pending receipt of this report. The service report from the contractor must contain, at a minimum, the following information:
a. Date and time of the contractor’s arrival on station
b. Site or serial number(s) of equipment on which maintenance was performed.
c. Total time spent performing maintenance, including travel time.
d. Detailed narrative description of the malfunction or PM action required.
e. Complete list of parts replaced.
f. Comments as to the cause of the malfunction when applicable
g. Date and time the repair or Pm was completed.
6. The contractor’s filed service employee shall wear visible identification at all times while on the premises of the VA Medical Center. Smoking is prohibited inside of buildings and only allowed in designated areas. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search, Violation of the VA regulation may result in citation answerable in the United States (Federal) District Court.
7. All vehicles will be locked and the keys removed while performing service on the Medical Center’s property. This is intended to protect the contractor’s property and provide for safety of the Medical Center’s personnel. Vehicle(s) shall be identified. Parking in the appropriate designated parking areas is expected. Information on parking is available from the on-site VA Police. The VA Medical Center will not invalidate or make reimbursement for parking violations of the contractor for any condition.
8. In performance of this contract, the contractor shall take such safety precautions as the Contracting Officer or designee may determine to be reasonably necessary to protect the lives and health of the occupants of any building. The Contracting Officer or designee will notify the contractor of any non-compliance with the foregoing provisions and action to be taken.
9. There is a potential for exposure to blood-borne or other infectious material with equipment throughout the hospital. All maintenance persons must use the “Universal Precautions” (i.e. decontamination of medical equipment, wearing protective gloves, aprons, and goggles) during the cleaning and maintenance/repair procedures required by this contract. BSCs that have been used for work involving infectious materials must be decontaminated before HEPA filters are changed or internal repair work is done. The contractor shall post signs at the door to the laboratory indicating that decontamination is in progress and entry is limited. In addition, a warning sign should also be displayed at the face of the BSC during the decontamination procedure.
10. The contractor does not require services that involve connection of one or more contractor-owned IT devices (such as a laptop computer or remote connection from a contractor system) to a VA internal trusted (i.e., non-public) network.
KCVA - RESEARCH HOODS LIST
Updated 10/13/20
2nd floor
10/5/2020
| Hood Type |
| Model |
| Location - Rm # |
| Quantity |
| Notes |
| BSL- Tissue culture or Laminar flow hood. |
| Kewaunee (Biosafety cabinet airflow) The Interceptor - INT-1400 |
| F2-102A |
| 1 |
| S/N 00592 |
| BSL- Tissue culture or Laminar flow hood. |
| Kewaunee (Biosafety cabinet airflow) The Interceptor - INT 1400 |
| F2-105A |
| 1 |
| S/N 00583 |
| BSL- Tissue culture or Laminar flow hood. |
| Kewaunee (Biosafety cabinet airflow) The Interceptor - INT-1400 |
| F2-126A |
| 1 |
| S/N 00584 |
| Chemical fume hood. |
| H05 Kewaunee Scientific Corp |
| F2-102 |
| 2 |
| Kewaunee Supreme Air |
| chemical fume hood. |
| H05 Kewaunee Scientific Corp |
| F2-105 |
| 2 |
| Kewaunee Supreme Air |
| Chemical fume hood. |
| H05 Kewaunee Scientific Corp |
| F2-126 |
| 2 |
| Kewaunee Supreme Air |
Total
3rd Floor
10/5/2020
| Hood Type |
| Model |
| Location - Rm # |
| Quantity |
| Notes |
| Fume Hood |
| H05 |
| F3-105 |
| 1 |
| 5-190220-14 |
| Fume Hood |
| H05 |
| F3-105 |
| 1 |
| 5-190220-15 |
| Biological Safety Cabinet |
| INT-1400-2; Type Class II A2 |
| F3-105A |
| 1 |
| S/N 00591 |
| Fume Hood |
| H05 |
| F3-102 |
| 1 |
| 5-190220-16 |
| Fume Hood |
| H05 |
| F3-102 |
| 1 |
| 5-190220-17 |
| Biological or Safety Cabinet |
| INT-1400-2; Type Class II A2 |
| F3-102A |
| 1 |
| INT -1400-2 S/N 00594 BSL |
| Fume Hood |
| H05 |
| F3-126 |
| 1 |
| PNL F3-122 CKT#27 |
| Fume Hood |
| H05 |
| F3-126 |
| 1 |
| PNL F3-122 CKT#29 |
| Biological or Safety Cabinet |
| INT-1400-2; Type Class II A2 |
| F3-126B |
| 1 |
| INT-1400-2 S/N 00589 BSL |
Total
4th Floor
10/5/2020
| Hood Type |
| Model |
| Location - Rm # |
| Quantity |
| Notes |
| Biological Hood |
| ESCO |
| F4-124 |
| 1 |
| S/N 2003-6202 |
| Biological Hood |
| VBM400/6640-0402 |
| F4-124 |
| 1 |
| S/N SP5210V BSL |
| Biological Hood |
| ESCO Class II Type A2 |
| F4-125 |
| 1 |
| S/N 2007-27974 BSL |
| Fume Hood |
| 6640-0403 |
| F4-125 |
| 1 |
| Biological Hood |
| ESCO Class II Type A2 |
| F4-105 |
| 1 |
| LA2-3A2 S/N 2006-19172 |
Fume Hood
| F4-105 |
| 1 |
| We did not find the model. - |
| Fume Hood |
| 6640-0404 |
| F4-120 |
| 1 |
| No Banerjee - |
| Fume Hood |
| 6640-0413 |
| F4-103 |
| 1 |
| No Banerjee - |
| Fume Hood |
| 640-0406 |
| F4-110 |
| 1 |
| No Banerjee - |
Total
5th floor
10/5/2020
| Hood Type |
| Model |
| Location - Rm # |
| Quantity |
| Notes |
| Biological or Safety cabinet hood |
| K-Cabinet: Fume hood |
| F5-105 |
| 1 |
| Biosafety cabinet |
| LABCONCO A2 |
| F5-105 |
| 1 |
| SN130575753 |
| Chemical fume hood |
| LABCONCO500 - |
| F5-112 |
| 2 |
| Chemical fume hood |
| K-Laboratory hood |
| F5-112 |
| 1 |
| Chemical fume hood |
| LABCONCO500 |
| F5-120 |
| 1 |
| CatNo: 2246300; Serial: 121065335D |
| Biological or Biosafety cabinet |
| LABCONCO A2 |
| F5-120 |
| 1 |
| Biological or Safety cabinet hood |
| LABCONCO - fume hood |
| F5-120 |
| 1 |
| SN:121065335 |
| Biosafety cabinet |
| The Baker Company (VBM400) |
| F5-121 |
| 1 |
| SN: SP5211V; Model VBM400 |
| Biological or Safety hood |
| KC-Oven/laboratory - fume hood |
| F5-121 |
| 1 |
| SN406000124 |
| Biological or Biosafety cabinet |
| LABCONCO |
| F5-130 |
| 1 |
| SN:1305766018 |
Animal Facility
10/5/2020
| Hood Type |
| Model |
| Location - Rm # |
| Quantity |
| Notes |
| ESCO - Biological Safety Cabinet |
| Sentinel-Gold |
| F6-194 |
| 1 |
| Biological Safety cabinet |
| Labconco - Biological Safety Cabinet |
| Purifier Vertical Clean Bench |
| F6-195A, 6-193 |
| 2 |
| Biological Safety cabinet |
| Labconco - Biological Safety Cabinet |
| A2 Logict |
| F6-160 |
| 0 |
| Biological Safety cabinet (NOT IN USE) NOT CERTIFIED |
| Labconco - Fume Hood |
| Did not find |
| F6-133 |
| 1 |
| Fume hood (made 1973-1983) |
| Labgard - Biological Safety Cabinet |
| NU-408FM-400 |
| F6-163 |
| 1 |
| Biological Safety cabinet |
| Fume hood |
| 47716 |
| F6-162 |
| 1 |
| S/N 35655 |
| Ancare Waste disposal |
| Class I BSL |
| F6-186 |
| 1 |
| Animal charge hood S/N 001988 |
| GRAND TOTAL |
| 45 |