36C25520R0063-005.pdf

PDF Posted

Attached to
Z1DA--Replace Mechanical Systems in Buildings 18 & 60 PN:657-19-103JB
Solicitation number
36C25520R0063
Issued by

About this file

This document provides a pre-solicitation notice for project 657-19-103JB to replace mechanical systems in Buildings 18 and 60 at the Jefferson Barracks Division VA Medical Center in St. Louis, Missouri. The project cost range is $2-5 million with a NAICS code of 238220 and small business size standard of $16.5 million. The contractor must provide all labor, materials, tools, equipment, supervision and site preparation. The duration is estimated at 426 calendar days from notice to proceed. Award will be made using Best Value Lowest Price Technically Acceptable and the prime contractor must perform at least 25% of construction labor. The solicitation will be posted to FedBizOpps on April 7, 2020 and site visit attendance is encouraged. Questions must be emailed by the response due date and award will be made without discussions unless necessary. The project is a total small business set-aside for Service-Disabled Veteran-Owned Small Businesses.

36C25520R0063 657-19-103JB - Combined Drawings 100PCT_Part3.pdf

View the file

Other files

File Type Posted
36C25520R0063-014.pdf PDF
36C25520R0063-016.pdf PDF
36C25520R0063-011.pdf PDF
36C25520R0063-006.pdf PDF
36C25520R0063-008.pdf PDF
36C25520R0063-015.pdf PDF
36C25520R0063-004.pdf PDF
36C25520R0063-009.pdf PDF
36C25520R0063-002.docx DOCX document
36C25520R0063-013.pdf PDF
36C25520R0063-007.pdf PDF
36C25520R0063-003.pdf PDF
36C25520R0063-010.pdf PDF
36C25520R0063-012.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STAIRWELL NO. 1

S301

CREDENTIALS

SUPERVISOR

CREDENTIALS

OFFICE

TELEHEALTH

SUPERVISOR

TELEHEALTH

SUPPLIES

KITCHEN

HAC

CORRIDOR

H302

CORRIDOR

H303

TOILET, MALE

ELEVATOR LOBBY

TOILET, FEMALE

STAIRWELL NO. 2

S302

OI&T

ELEC. CLOSET

CORRIDOR

H304

OFFICE

305A

OFFICE

CONFERENCE RM.

OFFICE

OFFICE

306A

OFFICE

OFFICE

BREAK RM.

OFFICE

OFFICE

311A

OFFICE

311E

OFFICE

OFFICE

311D

OFFICE

311B

OFFICE

311C

ELEVATOR

E1

VESTIBULE

H304A

STAIRWELL NO. 3

S303

18-ACU-1C

AP

FAP

FAPFEC

FEC

FAP

RAD

RADRAD

RADRADRADRAD

RAD

RAD

RADRADRADRADRADRADRADRADRAD

RAD

RAD

RAD RAD

RAD

RAD RAD

RAD RAD

RAD

RAD

RAD

RADRAD

RAD

RAD

RAD

RAD

RAD RAD RAD RADTELEHEALTH

WORKROOM

CREDENTIALS

SUPPLIES

CORRIDOR

H301A

CORRIDOR

H301

VAV-3-1D

VAV-3-12

VAV-3-14

VAV-3-16VAV-3-18

VAV-3-17 VAV-3-15

VAV-3-13

VAV-3-11

VAV-3-2

VAV-3-4

VAV-3-1C VAV-3-6 VAV-3-8

VAV-3-10

VAV-3-9

VAV-3-7

VAV-3-5

VAV-3-3

VAV-3-1A

VAV-3-1B

12"/12"

10"/12"

18"/12" 24"/12" 26"/14" 22"ø 22"ø 28"/12" 24"/12"

8" /1

2"

CD-1

173 CFM

CD-2

323 CFM

CD-2

245 CFM

CD-2

223 CFM

CD-1

189 CFM

CD-1

188 CFM

CD-1

188 CFM

CD-2

223 CFM

CD-2

223 CFM

CD-2

231 CFM

CD-2

225 CFM

CD-2

224 CFM

CD-1

150 CFM

CD-1

151 CFM

CD-1

150 CFM

CD-2

214 CFM

CD-2

215 CFM

CD-4

220 CFM

CD-4

220 CFM

CD-4

220 CFM

CD-4

220 CFM

CD-2

284 CFM

CD-2

231 CFM

CD-5

398 CFM

CD-4

225 CFM

CD-3

133 CFM

CD-3

133 CFM

CD-4

217 CFM

CD-4

205 CFM

CD-4

218 CFM

CD-3

109 CFM

CD-3

109 CFM

CD-3

110 CFM

CD-4

214 CFM

CD-3

184 CFM

CD-3

183 CFM

CD-3

193 CFM

CD-3

182 CFM

CD-3

185 CFM

CD-3

187 CFM

CD-4

221 CFM

CD-3

185 CFM

CD-5

552 CFM

"x

12"x6"

CD-1

196 CFM

RG-1

173 CFM

RG-2

223 CFM

RG-2

225 CFM

RG-2

224 CFM

RG-1

176 CFM

RG-1

176 CFM

RG-1

176 CFM

RG-1

176 CFM

RG-1

176 CFM RG-4

220 CFM

RG-4

220 CFM

RG-4

220 CFM

RG-4

220 CFM

RG-3

185 CFM

RG-4

221 CFM

RG-3

187 CFM

RG-3

182 CFM

RG-3

182 CFM

RG-3

193 CFM

RG-3

183 CFM

RG-3

184 CFM

RG-4

214 CFM

RG-3

110 CFM

RG-3

109 CFM

RG-3

109 CFM

RG-4

218 CFM

RG-4

205 CFM

RG-4

217 CFM

RG-3

133 CFM

RG-3

133 CFM

RG-4

225 CFM

EG-1

250 CFM

EG-1

300 CFM

RG-2

253 CFM

RG-2

253 CFM

RG-2

253 CFM

RG-2

253 CFM

RG-2

245 CFM

RG-2

323 CFM

EG-2

100 CFM

14"x16"

24"x24" UP

2 2

Plan North True North KEYPLAN th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :5

A

M

18-MH-131

MECHANICAL HVAC PLAN - FLOOR 03

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD RT Drawing # 36 of 77

1/8" = 1'-0"

MECHANICAL HVAC PLAN - FLOOR 03

GENERAL NOTES:

KEYNOTES:

PROVIDE SMOKE DAMPERS AT EACH DUCTWORK

PENETRATION. SEE DETAIL 3 ON SHEET 00-MG-701 FOR SMOKE

DAMPER CONTROL DIAGRAM.

Plan North True North

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION PHASING

REQUIREMENTS.

4. REPLACE THE RETURN AND SUPPLY DUCT DETECTORS ON 18-

AHU-SF AND 18-AHU-RF ON THE NEW DUCT WORK IN THE SAME

LOCATIONS. REPLACE ANY FIRE ALARM CONTROL RELAYS FOR

UNIT SHUTDOWN. COORDINATE WITH ELECTRICAL AND

MECHANICAL CONTRACTOR FOR THE LOCATION OF CONTACTS TO

CONNECT FOR SHUTDOWN. DUCT DETECTOR HOUSING AND

SAMPLING TUBES SHALL BE INSTALLED BY THE MECHANICAL

CONTRACTOR.

5. CLEAN RETURN DUCTWORK. PROVIDE NEW RETURN GRILLE,

CONNECTION, AND DAMPER.

2 PROVIDE PRESSURE TRANSMITTER.

18-EF-4

18"x18"

"x

18"x18"

Plan North True North KEYPLAN th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :5

A

M

18-MH-141

MECHANICAL HVAC PLAN - FLOOR 04

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD RT Drawing # 37 of 77

1/8" = 1'-0"

MECHANICAL HVAC PLAN - FLOOR 04

GENERAL NOTES:

KEYNOTES:

CONNECT NEW EXHAUST DUCTWORK TO EXISTING EXHAUST

FAN. REUSE EXISTING SUPPORTS FOR EXHAUST FAN DURING

INSTALLATION.

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION PHASING

REQUIREMENTS.

4. REPLACE THE RETURN AND SUPPLY DUCT DETECTORS ON 18-

AHU-SF AND 18-AHU-RF ON THE NEW DUCT WORK IN THE SAME

LOCATIONS. REPLACE ANY FIRE ALARM CONTROL RELAYS FOR

UNIT SHUTDOWN. COORDINATE WITH ELECTRICAL AND

MECHANICAL CONTRACTOR FOR THE LOCATION OF CONTACTS TO

CONNECT FOR SHUTDOWN. DUCT DETECTOR HOUSING AND

SAMPLING TUBES SHALL BE INSTALLED BY THE MECHANICAL

CONTRACTOR.

5. CLEAN RETURN DUCTWORK. PROVIDE NEW RETURN GRILLE,

CONNECTION, AND DAMPER.

Plan North True North

18"ø 26"/12"

10"x10"

24"/10"

14"x14" 12"x10"6"ø

"x

"x

52"x36"

"x

64"x24"

64"x24"

48"x55"

53"x44"

"x

42"ø

18-MH-401

43"x48"

18-MP-401

18-AHU-SF

"x

18-AHU-RF-1

36"x52"

42"x36"

48"x32"

"x

4" HOUSEKEEPING PAD. SEE

DETAIL 12/00-MG-502.

18-AHU-SF

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :5

A

M

18-MH-401

MECHANICAL HVAC LARGE-SCALE

VIEWS

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD RT Drawing # 38 of 77

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION PHASING

REQUIREMENTS.

4. REPLACE THE RETURN AND SUPPLY DUCT DETECTORS ON 18-

AHU-SF AND 18-AHU-RF ON THE NEW DUCT WORK IN THE SAME

LOCATIONS. REPLACE ANY FIRE ALARM CONTROL RELAYS FOR

UNIT SHUTDOWN. COORDINATE WITH ELECTRICAL AND

MECHANICAL CONTRACTOR FOR THE LOCATION OF CONTACTS TO

CONNECT FOR SHUTDOWN. DUCT DETECTOR HOUSING AND

SAMPLING TUBES SHALL BE INSTALLED BY THE MECHANICAL

CONTRACTOR.

5. CLEAN RETURN DUCTWORK. PROVIDE NEW RETURN GRILLE,

CONNECTION, AND DAMPER.

GENERAL NOTES:

KEYNOTES:

1/4" = 1'-0"

MECHANICAL HVAC PLAN - MECH. RM. 003

1/2" = 1'-0"

HVAC ELEVATION VIEW - MECH. RM. 003

AIRFLOW MEASURING STATION. SEE 00-MG-702 FOR DETAILED

CONTROLS DIAGRAM.

2 PROVIDE SMOKE DAMPERS AT EACH DUCTWORK PENETRATION.

SEE DETAIL 3 ON SHEET 00-MG-701 FOR DETAILED SMOKE DAMPER

CONTROL DIAGRAM.

VAV-B-1B

125 CFM

VAV-B-1A

1015 CFM

VAV-B-2

685 CFM

VAV-B-4

265 CFM

VAV-B-6

420 CFM

VAV-1-1A

410 CFM

VAV-1-1B

260 CFM

VAV-1-1C

425 CFM

VAV-1-1D

140 CFM

VAV-1-1E

495 CFM

VAV-1-2

360 CFM

VAV-1-3

270 CFM

VAV-1-4

210 CFM

VAV-1-5

360 CFM

VAV-1-6

285 CFM VAV-1-7

420 CFM

VAV-1-8

380 CFM

VAV-1-9

440 CFM

VAV-1-10

830 CFM

VAV-1-11

220 CFM

VAV-1-12

230 CFM

VAV-1-13

210 CFM

VAV-1-14

690 CFM

VAV-1-15

495 CFM

VAV-1-16

670 CFM

VAV-1-17

495 CFM

VAV-1-18

180 CFM

VAV-1-19

210 CFM

VAV-2-1A

425 CFM

VAV-2-1B

285 CFM

VAV-2-1C

550 CFM

VAV-2-1D

645 CFM

VAV-2-2

635 CFM

VAV-2-3

245 CFM

VAV-2-4

340 CFM

VAV-2-5

490 CFM

VAV-2-6

420 CFM

VAV-2-7

420 CFM

VAV-2-8

385 CFM

VAV-2-9

400 CFM

VAV-2-10

365 CFM

VAV-2-11

425 CFM

VAV-2-12

405 CFM

VAV-2-13

680 CFM

VAV-2-14

370 CFM

VAV-2-15

245 CFM

VAV-2-20

380 CFM

VAV-2-17

435 CFMVAV-2-18

370 CFM

VAV-2-19

430 CFM

VAV-3-1A

395 CFM

VAV-3-1B

280 CFM

VAV-3-1C

550 CFM

VAV-3-1D

195 CFM

VAV-3-2

875 CFM

VAV-3-3

485 CFMVAV-3-4

340 CFM

VAV-3-5

635 CFM

VAV-3-6

370 CFM

VAV-3-7

325 CFM

VAV-3-8

370 CFM

VAV-3-9

210 CFM

VAV-3-10

365 CFM

VAV-B-3

310 CFM

VAV-B-5

365 CFM

VAV-3-11

195 CFM

VAV-3-12

195 CFM

VAV-3-13

195 CFM

VAV-3-14

195 CFM

VAV-3-15

195 CFM

VAV-3-16

195 CFM

VAV-3-17

195 CFM

VAV-3-18

195 CFM

18-AHU-RF-1

RG-4

270 CFM

RG-4

265 CFM

RG-3

155 CFM

RG-3

154 CFM

RG-3

154 CFM

RG-3

127 CFM

RG-3

126 CFM RG-3

95 CFM

RG-3

95 CFM

RG-3

95 CFM

RG-3

95 CFM

RG-3

185 CFM

RG-3

185 CFM

RG-3

154 CFM

RG-3

154 CFM

RG-3

156 CFM

RG-4

223 CFM

RG-4

220 CFM

RG-4

223 CFM

RG-4

222 CFM

RG-4

220 CFM

RG-4

570 CFM

RG-4

570 CFM

RG-3

192 CFM

RG-3

191 CFM

RG-3

154 CFM

RG-4

213 CFM

RG-3

116 CFM

RG-3

116 CFM

RG-3

124 CFM

RG-4

213 CFM

RG-3

184 CFM

RG-3

196 CFM

RG-3

140 CFM

RG-4

221 CFM

RG-4

202 CFM

RG-3

200 CFM

RG-4

213 CFM

RG-3

179 CFM

RG-4

228 CFM

RG-4

227 CFM

RG-4

219 CFM

RG-4

208 CFM

RG-4

270 CFM

RG-3

188 CFM

RG-3

187 CFM

RG-3

192 CFM

RG-3

191 CFM

RG-3

187 CFM

RG-3

188 CFM

RG-4

269 CFM

RG-4

276 CFM

RG-3

105 CFM

RG-4

247 CFM

RG-4

341 CFM

RG-3

200 CFM

RG-3

193 CFM

RG-3

194 CFM

RG-1

185 CFM RG-1

185 CFM

RG-2

214 CFM

RG-2

213 CFM

RG-4

202 CFM

RG-4

202 CFM

RG-4

212 CFM

RG-4

212 CFM

RG-3

132 CFM

RG-3

132 CFM

RG-4

230 CFM

RG-4

216 CFM

RG-4

215 CFM

RG-4

219 CFM

RG-4

218 CFM

RG-4

246 CFM

RG-4

208 CFM

RG-4

207 CFM

RG-5

367 CFM

RG-4

225 CFM

RG-3

133 CFM

RG-3

133 CFM

RG-4

217 CFM

RG-4

205 CFM

RG-4

218 CFM

RG-3

109 CFM

RG-3

109 CFM

RG-3

110 CFM

RG-4

214 CFM

RG-3

184 CFM

RG-3

183 CFM

RG-3

193 CFM

RG-3

182 CFM

RG-3

182 CFM

RG-3

187 CFM

RG-4

221 CFM

RG-3

185 CFM

RG-4

220 CFM

RG-4

220 CFM

RG-4

220 CFM

RG-4

220 CFM

RG-2

253 CFM

RG-2

253 CFM

RG-2

253 CFM

RG-2

253 CFM

RG-2

245 CFM

RG-2

323 CFM

RG-1

173 CFM

RG-2

223 CFMRG-2

225 CFM

RG-2

224 CFM

RG-1

176 CFM

RG-1

176 CFM

RG-1

176 CFM

RG-1

176 CFM

RG-1

176 CFM

RG-4

204 CFM

RG-2

223 CFM

RG-1

198 CFM

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :0

A

M

18-MH-601

MECHANCIAL RISER DIAGRAM - HVAC

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD RDT Drawing # 39 of 77

NTS

HVAC RISER DIAGRAM - SUPPLY

NTS

HVAC RISER DIAGRAM - EXHAUST & RETURN

NTS

HVAC RISER DIAGRAM

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. DUCTWORK SHOWN IN HVAC RISER IS DIAGRAMATIC AND FOR

REFERENCE ONLY. SEE HVAC PLAN SHEETS FOR DETAILED VIEWS.

GENERAL NOTES:

BFP

4"ø GCR

4"ø GCS

2"ø HPS

3/4"ø PC

18-MP-401

Plan North True North KEYPLAN th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :0

A

M

18-MP-100

MECHANICAL PIPING PLAN -

SUB-BASEMENT

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD MDR Drawing # 40 of 77

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION PHASING

REQUIREMENTS.

GENERAL NOTES:

KEYNOTES:

Plan North True North1/8" = 1'-0"

MECHANICAL PIPING PLAN - SUB-BASEMENT

NEW STEAM PIPING TO BE INSTALLED WITH A FALL OF 1:100

OVER ALL HORIZONTAL RUNS.

NEW DRAIN PIPE TO BE INSTALLED WITH A SLOPE OF 1/8"

PER FOOT OVER ALL HORIZONTAL RUNS.

UP

UP

UP

UP

UP

T T

T

TTT

T

T

FAP

FAP

FAP

DF

RAD

RAD RAD RAD

RAD

RAD

RAD

RADRADRAD RAD

18-MP-401

PIPE CHASE

Z001

MECH. RM.

002 CORRIDOR

H001

ELEVATOR MACHINE

RM.

STAIRWELL NO. 2

S002

MECH. RM.

003A

OI&T

003B

BREAK RM.

OFFICE

OFFICE, CHIEF

OFFICE

OFFICE

VENDING

H003

OFFICE

MECH. RM.

ELEVATOR LOBBY

ELEVATOR

E1

TOILET, UNISEX

TOILET, FEMALE

HAC

CORRIDOR

H002

18-ACCH-1

DF

RAD

RAD RAD RAD

RAD

RAD

RAD

RADRADRAD RAD

VAV-B-1A

VAV-B-2

VAV-B-3

VAV-B-1B

VAV-B-5

VAV-B-6

VAV-B-4

1 1/4"ø HWR

1 1/4"ø HWS 1"ø HWS

3/4"ø HWS

3/4"ø HWR 1"ø HWR

1 1/4"ø HWR

/2 "ø

H W

R

/2 "ø

H W

S

4"ø GCS 4"ø GCR

1"ø LPS

"ø

H W

S

"ø

H W

R

18-MH-401

18-MP-401

18-AHU-SF

18-AHU-RF-1

3"ø HWR

3"ø HWS

1"ø DRAIN

/4

"ø D

H W

4"ø GCS

4"ø GCR

18-UH-1

Plan North True North KEYPLAN th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :0

A

M

18-MP-101

MECHANICAL PIPING PLAN - FLOOR 00

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD RT Drawing # 41 of 77

1/8" = 1'-0"

MECHANICAL PIPING PLAN - FLOOR 00

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION PHASING

REQUIREMENTS.

GENERAL NOTES:

KEYNOTES:

REMOVE STEAM RADIATOR COVER PANEL AND REPLACE

WITH BLANK PANEL ATTACHED TO RADIATOR.

Plan North True North

1 1 1

2 PROVIDE BLANKED OFF TEE FOR FUTURE CONNECTION.

3 REUSE EXISTING JCI THERMOSTAT/HUMIDISTAT.

INCORPORATE INTO EXISTING DDC SYSTEM.

4 ONICON SYSTEM 10 BTU CHILLED WATER METER

5 VERTICAL UNIT HEATER

6 NEW STEAM PIPING TO BE INSTALLED WITH A FALL OF 1:100

OVER ALL HORIZONTAL RUNS.

7 NEW DRAIN PIPE TO BE INSTALLED WITH A SLOPE OF 1/8"

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

T T T

T TTTT

T

T

T

T

T

T

T

T

T T

T

T

T

T

TT

T

FAP

FAP

FAP

FAP

RAD

RAD

RAD

RADRAD

RADRAD

RADRADRAD

RAD

RAD

RADRAD

RADRADRADRAD

RAD

RADRAD

RAD

RAD

RAD RAD

RAD RAD RAD

RAD

RAD RAD

RAD

RAD

RAD

RAD

RAD

OFFICE

OFFICE

OFFICE

FILE RM.

OFFICE

OFFICE

WORK RM.

STORAGE

TOILET, MALE

ELEVATOR LOBBY

TOILET, FEMALE

STAIRWELL NO. 2

S102CORRIDOR

H102

CORRIDOR

H103

OI&T

OFFICE

CORRIDOR

H101

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

LIBRARY

CORRIDOR

H104

CONFERENCE RM.

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

114A

OFFICE

BREAK RM.

115A

OFFICE, OPEN

OFFICE

OFFICE, CHIEF

113A

OFFICE

OFFICE

OFFICE

CORRIDOR

H105

ELEVATOR

E1

STAIRWELL NO. 3

S103

RECEPTION

STAIRWELL NO. 1

S101

18-ACU-1A

FAP

FAP

FAP

FAP

RAD

RAD

RAD

RADRAD

RADRAD

RADRADRAD

RAD

RAD

RADRAD

RADRADRADRAD

RAD

RADRAD

RAD

RAD

RAD RAD

RAD RAD RAD

RAD

RAD RAD

RAD

RAD

RAD

RAD

RAD

VAV-1-1B

VAV-1-1A

VAV-1-14

VAV-1-16

VAV-1-18

VAV-1-19 VAV-1-17

VAV-1-1E

VAV-1-15

VAV-1-13

VAV-1-12

VAV-1-1D

VAV-1-2

VAV-1-3

VAV-1-4 VAV-1-6

VAV-1-8

VAV-1-1C

VAV-1-10

VAV-1-11

VAV-1-9

VAV-1-7

VAV-1-5

/4

"ø H

W R

/4

"ø H

W S

1 1/4"ø HWR

1"ø HWR 3/4"ø HWS

1"ø HWS

3/4"ø HWR 3"ø HWS

3"ø HWR1 1/4"ø HWR

1 1/4"ø HWS

1"ø HWS1 1/4"ø HWR 1"ø HWR 3/4"ø HWS 3/4"ø HWR

1 1/4"ø HWS

18-ACU-01

1/4"ø R S

1/4"ø R L

1/4"ø RL

1/4"ø RS

1/4"ø RS

1/4"ø RL

1"ø DRAIN

2 2

Plan North True North KEYPLAN th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :1

A

M

18-MP-111

MECHANICAL PIPING PLAN - FLOOR 01

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD RT Drawing # 42 of 77

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION PHASING

REQUIREMENTS.

GENERAL NOTES:

KEYNOTES:

STEAM CONTROL VALVE AND PIPING STEM OF CONVECTION

RADIATOR SHALL BE REMOVED. SEE DETAIL 2 / 00-MG-505.

Plan North True North1/8" = 1'-0"

MECHANICAL PIPING PLAN - FLOOR 01

1 1

1 1 1

11111

2 REUSE EXISTING JCI THERMOSTAT/HUMIDISTAT.

INCORPORATE INTO EXISTING DDC SYSTEM.

3 TWO SUPPLY AND RETURN RISER PIPES FOR REFRIGERANT

LIQUID AND SUCTION LINES

4 THREE SUPPLY AND RETURN PIPES FOR REFRIGERANT

LIQUID AND SUCTION LINES

5 NEW DRAIN PIPE TO BE INSTALLED WITH A SLOPE OF 1/8"

UP

UP

T T

T T

T

T

T

T

T

T

T

T

T

T

T

T T

T

T

T

T

T

T

T

FAP

FAP

FAP

RAD

RAD

RAD

RAD

RAD

RAD

RAD

RADRAD

RADRADRADRADRAD

RADRAD

RAD

RAD RAD

RAD RAD RAD

RAD

RAD

RAD RAD

RAD RAD RAD RAD RAD

RAD

RAD

RAD

RAD

RAD

RADRAD

OFFICE

217C

OFFICE

217D

OFFICE

217E

OFFICE, SUPV.

HAC

OFFICE

215A

OFFICE

OFFICE

OFFICE

217A

OFFICE

217B

STAIRWELL NO. 1

S201

OFFICE

OFFICE

OFFICE

OFFICE

OI&T

ELEC. CLOSET

TOILET, MALE

TOILET, FEMALE

STAIRWELL NO. 2

S202

OFFICE

OFFICE

OFFICE, SUPV.

OFFICE, CHIEF

CORRIDOR

H203

CORRIDOR

H202

ELEVATOR LOBBY

CORRIDOR

H204

OFFICE

207A

OFFICE

207B

OFFICE

OFFICE

210B

OFFICE

210A

OFFICE

205A

CORRIDOR

H201

KITCHENETTE

212A

ELEVATOR

E1

CHASE

CH-2-1

STAIRWELL NO. 3

S203

18-ACU-1B

FAP

FAP

FAP

RAD

RAD

RAD

RAD

RAD

RAD

RAD

RADRAD

RADRADRADRADRAD

RADRAD

RAD

RAD RAD

RAD RAD RAD

RAD

RAD

RAD RAD

RAD RAD RAD RAD RAD

RAD

RAD

RAD

RAD

RAD

RADRAD

VAV-2-1B

VAV-2-1A

VAV-2-13VAV-2-15

VAV-2-17

VAV-2-19

VAV-2-18

VAV-2-20

VAV-2-14

VAV-2-12

VAV-2-1D

VAV-2-2

VAV-2-3

VAV-2-4 VAV-2-6

VAV-2-8 VAV-2-10

VAV-2-11VAV-2-9VAV-2-7VAV-2-1CVAV-2-5

1 1/2"ø HWS

1 1/4"ø HWS 1"ø HWS 3/4"ø HWS 1 1/2"ø HWR

1 1/4"ø HWR

1"ø HWR

3/4"ø HWR

/4

"ø H

W S

/4

"ø H

W R

3"ø HWS

3"ø HWR

1 1/2"ø HWS

1 1/2"ø HWR

1"ø HWS1"ø HWR1 1/4"ø HWR

/4

"ø R

S /4

"ø R

L

Plan North True North KEYPLAN th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :1

A

M

18-MP-121

MECHANICAL PIPING PLAN - FLOOR 02

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD RT Drawing # 43 of 77

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION PHASING

REQUIREMENTS.

GENERAL NOTES:

KEYNOTES:

Plan North True North1/8" = 1'-0"

MECHANICAL PIPING PLAN - FLOOR 02

1 1 1 1 1

1 1 1 1

STEAM CONTROL VALVE AND PIPING STEM OF CONVECTION

RADIATOR SHALL BE REMOVED. SEE DETAIL 2/00-MG-505.

2 REUSE EXISTING JCI THERMOSTAT/HUMIDISTAT.

INCORPORATE INTO EXISTING DDC SYSTEM.

3 NEW DRAIN PIPE TO BE INSTALLED WITH A SLOPE OF 1/8"

T

T

T T T

T

T

TT

T

T

T

T

T

T

T T

T

T

T

T

T

FAP

FAP

FAP

RAD

RADRAD

RADRADRADRAD

RAD

RAD

RADRADRADRADRADRADRADRADRAD

RAD

RAD

RAD RAD

RAD

RAD RAD

RAD RAD

RAD

RAD

RAD

RADRAD

RAD

RAD

RAD

RAD

RAD RAD RAD RAD

STAIRWELL NO. 1

S301

CREDENTIALS

SUPERVISOR

CREDENTIALS

OFFICE

TELEHEALTH

SUPERVISOR

TELEHEALTH

SUPPLIES

TELEHEALTH

WORKROOM

CORRIDOR

H301

KITCHEN

HAC

CORRIDOR

H302

CORRIDOR

H303

TOILET, MALE

ELEVATOR LOBBY

TOILET, FEMALE

STAIRWELL NO. 2

S302

OI&T

ELEC. CLOSET

CORRIDOR

H304

OFFICE

305A

OFFICE

CONFERENCE RM.

OFFICE

OFFICE

306A

OFFICE

OFFICE

BREAK RM.

OFFICE

OFFICE

311A

OFFICE

311E

OFFICE

OFFICE

311D

OFFICE

311B

OFFICE

311C

ELEVATOR

E1

VESTIBULE

H304A

STAIRWELL NO. 3

S303

18-ACU-1C

FAP

FAP

FAP

RAD

RADRAD

RADRADRADRAD

RAD

RAD

RADRADRADRADRADRADRADRADRAD

RAD

RAD

RAD RAD

RAD

RAD RAD

RAD RAD

RAD

RAD

RAD

RADRAD

RAD

RAD

RAD

RAD

RAD RAD RAD RAD

CORRIDOR

H301A

CREDENTIALS

SUPPLIES

VAV-3-1D

VAV-3-12VAV-3-14VAV-3-16

VAV-3-18

VAV-3-17 VAV-3-15 VAV-3-13 VAV-3-11

VAV-3-2

VAV-3-4

VAV-3-1C VAV-3-6

VAV-3-8 VAV-3-10

VAV-3-9

VAV-3-7

VAV-3-5VAV-3-3

VAV-3-1A

VAV-3-1B

3"ø HWS

2"ø HWR

/4

"ø H

W S 3

/4 "ø

H W

R

1 1/2"ø HWS

1 1/2"ø HWR

1 1/4"ø HWS 1"ø HWR 1 1/4"ø HWR 3/4"ø HWS

1 1/4"ø HWS

1 1/4"ø HWR3/4"ø HWR1"ø HWS

3/4"ø HWS

1"ø HWR

/4

"ø R

L

/4

"ø R

S

"ø

D R

A

IN

Plan North True North KEYPLAN th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :2

A

M

18-MP-131

MECHANICAL PIPING PLAN - FLOOR 03

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD RT Drawing # 44 of 77

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION PHASING

REQUIREMENTS.

GENERAL NOTES:

KEYNOTES:

Plan North True North1/8" = 1'-0"

MECHANICAL PIPING PLAN - FLOOR 03

1 1 1 1 1

1 1

1 1 1

STEAM CONTROL VALVE AND PIPING STEM OF CONVECTION

RADIATOR SHALL BE REMOVED. SEE DETAIL 2 / 00-MG-505.

2 REUSE EXISTING JCI THERMOSTAT/HUMIDISTAT.

INCORPORATE INTO EXISTING DDC SYSTEM

3 NEW DRAIN PIPE TO BE INSTALLED WITH A SLOPE OF 1/8"

BFP

(N)18-CRP-1

18-DWH-1

18-PRV-1A/B 2

"ø

H P

S

3"ø HWR

3"ø HWS

18-HHW-P-2

18-HHW-P-1

18-ET-01

"ø

H W

R

"ø

H W

S

"ø

L P

S

3/4"ø DHW

1"ø LPS

1"ø DRAIN

1"ø DCW

/4

"ø D

H W

R

18-HX-1A

/4

"ø P

C

18-MP-401

18-HX-1B

/4

"ø L

P R

18-MP-401

1"ø GCR

1"ø DCW

1"ø HPS

1"ø HWR

18-GMP-01

18-ET-02

1"ø LPS

4"ø LPS

"ø

H W

R

/4

"ø D

H W

R

/4

"ø D

H W

3"ø HWS

18-HHW-P-2

18-HHW-P-1

18-HX-1B

18-HX-1A18-PRV-1A/B

18-DWH-1

4" HOUSEKEEPING PAD. SEE

DETAIL 12/00-MG-502.

1"ø DCW

4"ø GCR 4"ø GCS

"ø

L P

S

/2 "ø

H W

S

/2 "ø

H W

R

"ø

H W

S "ø

H W

R

1 1/4"ø HWR

1 1/4"ø HWS

"ø

D R

A

IN

18-AHU-SF

PROVIDE CAPPED

CHS/CHR PIPE FOR

FUTURE CONNECTION

18-PRV-1A/B

18-HX-1A

18-HHW-P-2

18-ET-01

(N)18-CRP-1

18-HX-1B

1"ø LPS

"ø

H W

S

"ø

H W

R

2"ø HPS

3/4"ø PC 3"ø HWR

3"ø HWS

4" HOUSEKEEPING PAD. SEE DETAILS

12/00-MG-502 & 6/00-MG-505.

"ø

G C

R "ø

H W

R

1"ø GCR

18-GMP-01

18-ET-02

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :2

A

M

18-MP-401

MECHANICAL PIPING LARGE-SCALE

VIEWS

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD MDR Drawing # 45 of 77

1/2" = 1'-0"

MECHANICAL PIPING PLAN - MECH. RM. 002

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION PHASING

REQUIREMENTS.

GENERAL NOTES:

KEYNOTES:

SEE DETAIL 6 ON 00-MG-505 FOR ELEVATION VIEW AND SUPPORT

DETAIL OF STACKED HOT WATER HEAT EXCHANGER. SEE DETAIL 5

ON 00-MG-504 FOR CONNECTION DETAILS OF STACKED HOT

WATER HEAT EXCHANGER.

1/2" = 1'-0"

PIPING ELEVATION VIEW - MECH. RM. 002 (N)

1/4" = 1'-0"

MECHANICAL PIPING PLAN - MECH. RM. 003

1/2" = 1'-0"

PIPING ELEVATION VIEW - MECH. RM. 002 (W)

2 VENT PIPING NOT SHOWN. SIZE PER EQUIPMENT REQUIREMENTS

AND REUSE EXISTING VENTING PENETRATIONS.

3 CONDENSATE COOLER.

18-DWH-1

18-PRV-1A/B

(N)18-CRP-1

18-ACU-1A

18-ACU-1B

18-ACU-1C

VAV-B-1B

0.3 GPM

VAV-B-1A

1.6 GPM

VAV-B-2

0.8 GPM

VAV-B-4

1.0 GPM

VAV-B-6

0.7 GPM

VAV-1-1A

0.7 GPM

VAV-1-1B

0.7 GPM

VAV-1-1C

0.7 GPM

VAV-1-1D

0.3 GPM

VAV-1-1E

0.7 GPM

VAV-1-2

0.8 GPM

VAV-1-3

0.5 GPM

VAV-1-4

0.4 GPM

VAV-1-5

1.1 GPM

VAV-1-6

1.1 GPM

VAV-1-7

0.8 GPM

VAV-1-8

1.1 GPM

VAV-1-9

0.6 GPM

VAV-1-10

3.1 GPM

VAV-1-11

0.4 GPM

VAV-1-12

0.3 GPM

VAV-1-13

0.4 GPM

VAV-1-14

3.6 GPM

VAV-1-15

0.7 GPM

VAV-1-16

2.3 GPM

VAV-1-17

2.6 GPM

VAV-1-18

0.3 GPM

VAV-1-19

0.0 GPM

VAV-2-1A

0.7 GPM

VAV-2-1B

0.9 GPM

VAV-2-1C

0.8 GPM

VAV-2-1D

4.7 GPM

VAV-2-2

1.7 GPM

VAV-2-3

0.4 GPM

VAV-2-4

0.6 GPM

VAV-2-5

1.0 GPM

VAV-2-6

4.2 GPM

VAV-2-7

0.9 GPM

VAV-2-8

1.5 GPM

VAV-2-9

0.7 GPM

VAV-2-10

1.4 GPM

VAV-2-11

1.2 GPM

VAV-2-12

2.0 GPM

VAV-2-13

1.1 GPM

VAV-2-14

1.2 GPM

VAV-2-15

0.4 GPM

VAV-2-20

1.4 GPM

VAV-2-17

0.6 GPM

VAV-2-18

4.9 GPM

VAV-2-19

2.6 GPM

VAV-3-1A

0.6 GPM

VAV-3-1B

0.9 GPM

VAV-3-1C

0.8 GPM

VAV-3-1D

0.4 GPM

VAV-3-2

6.9 GPM

VAV-3-3

1.1 GPM

VAV-3-4

1.1 GPM

VAV-3-5

1.8 GPM

VAV-3-6

1.1 GPM

VAV-3-7

1.3 GPM

VAV-3-8

1.2 GPM

VAV-3-9

0.4 GPM

VAV-3-10

2.6 GPM

VAV-B-3

1.8 GPM

VAV-B-5

0.7 GPM

VAV-3-11

0.7 GPM

VAV-3-12

0.5 GPM

VAV-3-13

2.0 GPM

VAV-3-14

0.8 GPM

VAV-3-15

1.8 GPM

VAV-3-16

0.7 GPM

VAV-3-17

3.0 GPM

VAV-3-18

1.1 GPM

18-HX-1A

18-HX-1B

18-ACU-01

18-DHW-P-1

18-UH-1

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:1 :2

A

M

18-MP-601

MECHANCIAL RISER DIAGRAM - PIPING

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

DD RDT Drawing # 46 of 77

PIPING RISER DIAGRAM

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL SYMBOLS,

ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE COR

BEFORE PROCEEDING WITH WORK.

3. HEATING WATER PIPING SHOWN IN PIPING RISER IS DIAGRAMATIC

AND FOR REFERENCE ONLY. SEE PIPING PLAN SHEETS FOR

DETAILED VIEWS.

GENERAL NOTES:

60-KH-D 60-KH-E 60-KH-F

60-KH-A 60-KH-B 60-KH-C

Plan North

True North

KEYPLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

02/10/2020

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

657-19-103JB

/1

/2

:2 :0

A

M

60-MD-111

MECHANICAL DEMOLITION PLAN -

FLOOR 01

FCA - REPLACE MECHANICAL

SYSTEMS IN BLDG 18 & 60

DD RDT

Drawing # 47 of 77

GENERAL NOTES:

1. REFER TO 00-MG-001 AND 00-MG-002 FOR

MECHANICAL SYMBOLS, ABBREVIATIONS, AND

GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING CONDITIONS AND REPORT ANY

DISCREPANCIES TO THE COR BEFORE

PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION

PHASING REQUIREMENTS.

4. ESTIMATED KITCHEN DOWNTIME IS 4 DAYS.

PROVIDE MINIMUM 3 WEEK PRIOR NOTICE TO

CONTRACTING OFFICER FOR SCHEDULING. ALL

WORK IS TO BE COMPLETED OVER A WEEKEND.

Plan North

True North

1/8" = 1'-0"

MECHANICAL HVAC DEMOLITION FLOOR PLAN

60-MAU-1

60-MAU-2

Plan North

True North

KEYPLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

02/10/2020

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

657-19-103JB

/1

/2

:2 :0

A

M

60-MD-121

MECHANICAL DEMOLITION PLAN -

FLOOR 02

FCA - REPLACE MECHANICAL

SYSTEMS IN BLDG 18 & 60

DD RDT

Drawing # 48 of 77

1/8" = 1'-0"

MECHANICAL HVAC DEMOLTION ROOF PLAN

GENERAL NOTES:

1. REFER TO 00-MG-001 AND 00-MG-002 FOR

MECHANICAL SYMBOLS, ABBREVIATIONS, AND

GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY

ALL EXISTING CONDITIONS AND REPORT ANY

DISCREPANCIES TO THE COR BEFORE

PROCEEDING WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION

PHASING REQUIREMENTS.

4. ESTIMATED KITCHEN DOWNTIME IS 4 DAYS.

PROVIDE MINIMUM 3 WEEK PRIOR NOTICE TO

CONTRACTING OFFICER FOR SCHEDULING. ALL

WORK IS TO BE COMPLETED OVER A WEEKEND.

Plan North

True North

L P

S

/2

D

60-KH-1 60-KH-2 60-KH-3

60-KH-460-KH-560-KH-6

60-MH-111

60-MH-111

16"ø 21"ø

16"ø21"ø

16"x30"

16"x30"

1-1/2"

COIL

NOTES:

1. RUNOUT PIPING FOR CONNECTIONS

TO COIL SHALL BE INSTALLED WITH

SWING JOINTS TO ALLOW FOR

VIBRATION.

2. PIPING SHALL BE INSTALLED IN

SUCH A MANNER THAT IT WILL NOT

BLOCK THE SWING OR USE OF ACCESS

DOORS OR PANELS; NEITHER SHALL IT

BLOCK THE SERVICING OF FILTERS,

VALVES, OR EQUIPMENT.

UNIT CASING

ROOF LINE

1" 1"

1-1/2"

1"

FLOOR 01

0' - 0"

T.O. PARAPET

17' - 0"

60-MH-111

"x

"x

"x

30"x16"

"ø

60-MAU-1 60-MAU-2

60-KH-6 60-KH-5 60-KH-4

FLOOR 01

0' - 0"

T.O. PARAPET

17' - 0"

16"x30"

"x

"ø

"x

60-MAU-1

60-MAU-2

60-KH-1 60-KH-6

Plan North

True North

KEYPLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

02/10/2020

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

657-19-103JB

/1

/2

:2 :0

A

M

60-MH-111

MECHANICAL HVAC PLAN - FLOOR 01 FCA - REPLACE MECHANICAL

SYSTEMS IN BLDG 18 & 60

DD RDT

Drawing # 49 of 77

1/8" = 1'-0"

MECHANICAL HVAC FLOOR PLAN - 01

GENERAL NOTES:

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL

SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL

EXISTING CONDITIONS AND REPORT ANY

DISCREPANCIES TO THE COR BEFORE PROCEEDING

WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION

PHASING REQUIREMENTS.

4. REPLACE THE RETURN AND SUPPLY DUCT DETECTORS

ON 60-MAU-01 AND 60-MAU-02 ON THE NEW DUCTWORK

IN THE SAME LOCATIONS. REPLACE ANY FIRE ALARM

CONTROL RELAYS FOR UNIT SHUTDOWN. COORDINATE

WITH ELECTRICAL AND MECHANICAL CONTRACTOR

FOR THE LOCATION OF CONTACTS TO CONNECT FOR

SHUTDOWN. DUCT DETECTOR HOUSING AND SAMPLING

TUBES SHALL BE INSTALLED BY THE MECHANICAL

CONTRACTOR.

Plan North

True North

NTS

STEAM COIL - PIPING CONNECTIONS

KEYNOTES:

MANUFACTURER PROVIDED HAND-OFF-AUTO SWITCH

FOR KITCHEN HOOD CONTROL.

1/4" = 1'-0"

HVAC ELEVATION 1

1/4" = 1'-0"

HVAC ELEVATION 2

60-MAU-1 60-MAU-2

60-MH-111

60-MH-111

Plan North

True North

KEYPLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

02/10/2020

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

657-19-103JB

/1

/2

:2 :0

A

M

60-MH-121

MECHANICAL HVAC PLAN - FLOOR 02 FCA - REPLACE MECHANICAL

SYSTEMS IN BLDG 18 & 60

DD RDT

Drawing # 50 of 77

GENERAL NOTES:

KEYNOTES:

1 PIPING ROUTED THROUGH THE ROOF SHALL BE

SLEEVED AND PATCHED PER SPECIFICATION SECTION

22 05 11.

Plan North

True North

1/8" = 1'-0"

MECHANICAL HVAC PLAN - 02

1. REFER TO 00-MG-001 AND 00-MG-002 FOR MECHANICAL

SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES.

2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL

EXISTING CONDITIONS AND REPORT ANY

DISCREPANCIES TO THE COR BEFORE PROCEEDING

WITH WORK.

3. REFER TO 00-MG-801 FOR ALL CONSTRUCTION

PHASING REQUIREMENTS.

4. REPLACE THE RETURN AND SUPPLY DUCT DETECTORS

ON 60-MAU-01 AND 60-MAU-02 ON THE NEW DUCTWORK

IN THE SAME LOCATIONS. REPLACE ANY FIRE ALARM

CONTROL RELAYS FOR UNIT SHUTDOWN. COORDINATE

WITH ELECTRICAL AND MECHANICAL CONTRACTOR

FOR THE LOCATION OF CONTACTS TO CONNECT FOR

SHUTDOWN. DUCT DETECTOR HOUSING AND SAMPLING

TUBES SHALL BE INSTALLED BY THE MECHANICAL

CONTRACTOR.

COMMUNICATION GENERAL NOTES:

A. FOR WHEEL CHAIR PATIENT USE MOUNT TELEPHONE OUTLET 35" AFF TO BOTTOM OF OUTLET BOX.

B. DESK PHONES - MOUNT OUTLET 1'-6" AFF

C. PAY PHONES - MOUNT OUTLET 4'-0" AFF

D. HEIGHT OF TELECART OUTLETS SHALL BE AS INDICATED ON BED WALLS OR PBPU DETAILS.

E. SEE VA. BARRIER FREE DESIGN GUIDE PG-18-13

ELECTRICAL GENERAL NOTES - DEMOLITION:

A. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR PHASES OF DEMOLITION AND

CONSTRUCTION. COORDINATE WITH GENERAL CONSTRUCTION.

B. DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND LIGHTING FIXTURES IN DEMOLITION AREAS UNLESS NOTED OTHERWISE. DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO THE OVERCURRENT PROTECTIVE DEVICE. COMPLETELY CUT/CAP CONDUITS IN CONCRETE SLAB AND IN THE AREA OF WORK PERIMETER. DISCONNECT AND REMOVE ALL ABANDONED CIRCUITS AND CONDUITS.

PROVED CONDUIT AND WIRE AS REQUIRED FOR CONTINUITY OF CIRCUITS TO ANY EXISTING DEVICES TO

REMAIN. COORDINATE AND VERIFY REQUIREMENTS WITHIN NEW AREA OF WORK.

C. DISCONNECT AND REMOVE ALL WIRES AND CONDUIT BACK TO THE OVERCURRENT DEVICE AND RELABEL

AS A SPARE.

D. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS PASSING THROUGH

RENOVATED AREAS AND SERVICING UNDISTURBED AREAS.

E. REMOVE ALL ACCESSIBLE ABANDONED WIRING OF ALL TYPES, OR CAP AND LABEL IN JUNCTION BOX FOR

RE-USE, IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE.

F. REPLACE ALL EXISTING MULTI-PHASE BRANCH CIRCUIT BREAKERS WITH HANDLE TIE BREAKERS ON ALL

MULTI-PHASE CIRCUITS.

ELECTRICAL GENERAL NOTES:

A. SPECIFICATIONS TAKE PRECEDENT OVER DRAWINGS.

B. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING FIXTURES SHALL BE OBTAINED FROM THE

ARCHITECTURAL REFLECTED CEILING PLAN.

C. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS. EACH BRANCH CIRCUIT

HOMERUN SHALL HAVE A SEPARATE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR.

D. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY AND NORMAL BRANCH

WIRING DEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.

E. ALL WIRING SHALL BE (3)#12 THWN/THHN COPPER 3/4C" UNLESS OTHERWISE NOTED.

F. MINIMUM SIZE CONDUIT FOR CONTROL CIRCUITS SHALL BE 1/2".

G. CORE DRILL AND SAW CUT, AS REQUIRED, FOR FLOOR AND WALL PENETRATIONS. SEAL REMAINING

ANULUS WITH FIRE CAULK.

H. FURNISH ACCESS DOORS OR PANELS FOR INSTALLATION BY GENERAL CONTRACTOR IN WALLS AND

CEILINGS WHERE ACCESS IS REQUIRED TO CONCEALED ELECTRICAL BOXES AND DEVICES.

I. ARMORED CABLE (AC) MAY BE USED FOR LAY-IN FIXTURE PIGTAILS. ARMORED CABLE (AC) SHALL NOT BE USED FOR BRANCH CIRCUIT HOMERUNS. ARMORED CABLE (AC) SHALL NOT BE USED WHERE MORE THAN THREE CONDUCTORS (PHASE/NEUTRAL/GROUND) ARE REQUIRED, WHERE EXPOSED; OR IN LENGTHS

EXCEEDING 20 FEET EXCEPT FOR TEMPORARY WIRING.

J. PROVIDE ALL ELECTRICAL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE AND

THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION.

K. COORDINATE ALL OUTAGES WITH VA COR PER SPECS PRIOR TO WORK BEING DONE.

L. REUSE ALL EXISTING PANELS.

M. ALL VAV'S TO REUSE EXISTING CIRCUITS. ALL CIRCUITING ON SHEETS IS TO BE UPDATED WITH ONE AS BUILTS WITH CORRECT CIRCUIT AND ALL PANEL SCHEDULES TO BE UPDATED WITH UPDATED VAV

NUMBERS AND BREAKER SIZES AND CIRCUITS.

ELECTRICAL EQUIPMENT AND DISTRIBUTION SYSTEM

(RACEWAYS) 2015 IBC AND ASCE 7-10 NONSTRUCTURAL

SEISMIC RESTRAINT, BRACING AND ANCHORAGE NOTES:

REFERENCE SPECIFICATION: SECTION 13 05 41

SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS

SEISMIC DESIGN DATA FOR ANALYSIS AND DESIGN:

H-18-8 SEISMICITY = HIGH

SEISMIC RISK CATEGORY BASED UPON CRITICAL OCCUPANCY = IV

COMPONENT IMPORTANCE FACTORS:

IP=1.0 FOR NON-ESSENTIAL COMPONENTS NOT REQUIRED FOR CONTINUED OPERATION OR IF ITS

FAILURE WILL NOT IMPAIR THE CONTINUED OPERATION OF THE FACILITY

IP=1.5 FOR LIFE SAFETY AND DESIGNATED SEISMIC SYSTEMS (DSS) AND PERMANENT EQUIPMENT AND

COMPONENTS REQUIRING SPECIAL SEISMIC CERTIFICATION PER H-18-8.

FOR MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS AND DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS: SEE GENERAL STRUCTURAL NOTES AND DESIGN CRITERIA AS SPECIFIED ON

DRAWING NUMBER S-000.

SITE CLASS = C (PER GEOTECHNICAL REPORT)

SEISMIC DESIGN CATEGORY (SDC) = D

NONSTRUCTURAL SEISMIC EXCEPTIONS AND EXEMPTIONS SHALL BE DETERMINED IN ACCORDANCE WITH

H-18-8 AND CHAPTER 13 OF ASCE 7 FOR SDC = D.

H-18-8 EQUIPMENT AND COMPONENTS SPECIAL SEISMIC CERTIFICATION (SSC) REQUIREMENT:

IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY C, D, E, OR F, PERMANENT EQUIPMENT AND COMPONENTS ARE TO HAVE SPECIAL SEISMIC CERTIFICATION IN ACCORDANCE WITH REQUIREMENTSW OF SECTION 13.2.2 OF ASCE 7 EXCEPT FOR EQUIPMENT AND COMPONENTS THAT ARE CONSIDERED RUGGED AS LISTED IN SECTION 2.2 OF OSHPD CODE APPLICATION NOTICE CAN NO. 2-1708A.5, AND SHALL COMPLY WITH

SECTION 13.2.6 OF ASCE 7.

CLARIFICATION OF ASCE 7 "12 INCH RULE" SUSPENDED SEISMIC BRACING CODE EXCEPTION FOR PIPING AND

HVAC DUCTWORK.:

ALL PIPING OR DUCTWORK SUSPENDED BY INDIVIDUAL HANGER RODS 12" OR LESS AS MEASURED FROM THE TOP OF THE PIPING OR DUCTWORK TO THE BOTTOM OF THE SUPPORT WHERE THE HANGER IS ATTACHED. IF THE 12" LIMIT IS EXCEEDED BY ANY HANGER IN THE RUN, SEISMIC BRACING IS REQUIRED FOR THE RUN. A SINGLE SUPPORT LOCATION THAT MEETS THE REQUIREMENT OF THIS EXCEPTION DOES NOT CONSTITUTE A

SEISMIC SWAY BRACE LOCATION.

IN ADDITION, TO MEET THE CODE REQUIREMENTS, ALL OF THE FOLLOWING CONDITIONS MUST ALSO BE

SATISFIED:

1. LATERLA MOTION OF PIPING OR DUCTWORK WILL NOT CAUSE DAMAGING IMPACT WITH SURROUND SYSTEMS (E.G. OTHER CONDUIT, TRAY, PIPE, DUCT, EQUIPMENT, SPRINKLER HEADS ETC.) OR CAUSE LOSS

OF SYSTEM VERTICAL SUPPORT.

2. PIPING OR DUCTWORK MUST BE MADE OF DUCTILE MATERIAL WITH DUCTILE CONNECTIONS.

3. VERTICAL SUPPORT CONNECTIONS CANNOT DEVELOP MOMENTS (E.G. SWIVEL JOINTS, EYE BOLTS, VIBRATION ISOLATION HANGERS, ETC.)

KEY NOTES:

KEY NOTE00

NEW - EXISTING AND DEMO LINE TYPES:

NEW LINE TYPE

EXISTING LINE TYPE

DEMO LINE TYPE

DEMO HATCH

LIGHTING GENERAL NOTES:

A. ALL RECESSED LIGHTING FIXTURE IN LAY-IN CEILINGS SHALL BE INSTALLED WITH 6' LONG FLEXIBLE METAL

CONDUIT.

B. ALL MOUNTING HEIGHTS FOR LIGHTING FIXTURES ARE TO THE BOTTOM OF THE FIXTURES UNLESS

INDICATED OTHERWISE.

C. SEE ARCHITECTURAL EXTERIOR ELEVATIONS FOR MOUNTING HEIGHTS OF EXTERIOR LIGHTING FIXTURES.

D. CIRCUIT WIRING IS NOT SHOWN. SWITCH AND CIRCUITING INTENT SHALL BE AS DESIGNATED AT

EACH LIGHT FIXTURE.

E. PROVIDE PROPER NUMBER OF CONDUCTORS TO ACHIEVE CIRCUITING AND SWITCHING SHOWN.

F. CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD BREAKERS (SEE PANELBOARD

SCHEDULE). BRANCH CIRCUITS SHALL BE SIZED ACCORDING TO THE CIRCUIT BREAKER RATING, UNLESS

INDICATED OTHERWISE ON THE ELECTRICAL EQUIPMENT SCHEDULE.

ELECTRICAL SEISMIC GENERAL NOTES:

A. GC SHALL HAVE SEISMIC-FORCE-RESTRAINT SHOP DRAWINGS AND, CALCULATIONS PREPARED BY PROFESSIONAL STRUCTURAL ENGINEER EXPERIENCED IN THE AREA OF SEISMIC FORCE RESTRAINTS.THE PROFESSIONAL STRUCTURAL ENGINEER SHALL BE REGISTERED IN THE STATE WHERE THE PROJECT IS

LOCATED.

B. SUBMIT DESIGN TABLES AND INFORMATION USED FOR THE DESIGN-FORCE LEVELS, STAMPED AND SIGNED BY A PROFESSIONAL STRUCTURAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS

LOCATED.

C. "DO NOT INSTALL" SEISMIC RESTRAINT UNTIL SUBMITTALS ARE APPROVED BY THE COR. COORDINATE AND INSTALL TRAPEZE OR OTHER MULTI-PIPE HANGER SYSTEMS PRIOR TO CONDUIT INSTALLATION.

D. IN STRUCTURES ASSIGNED TO IBC SEISMIC DESIGN CATEGORY C, D, E, OR F, PERMANENT EQUIPMENTS AND COMPONENTS ARE TO HAVE SPECIAL SEISMIC CERTIFICATION IN ACCORDANCE WITH REQUIREMENTS OF SECTION 13.2.2 OF THE ASCE 7 EXCEPT FOR EQUIPMENT THAT ARE CONSIDERED RUGGED AS LISTED IN SECTION 2.2 OSHPD CODE APPLICATION NOTICE CAN NO. 2-1708A.5 AND SHALL COMPLY WITH SECTION

13.2.6 OF ASCE 7.

E. GC AND EC SHALL REVIEW AND COMPLETE ALL SEISMIC RESTRAINT REQUIREMENTS PER SPECIFICATION

SECTION 13 05 41.

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS: 657-19-103JB

VA Health Care System Approval:

Revision: Date:

ARCHITECT/ENGINEER:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307

WWW.VALHALLAENGINEERING.COM VEG 19.7

100% CONTRACT DOCUMENT SUBMITTAL DRAWINGS

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

02/10/2020

/1

/2

:5 :0

P

M

00-EG-001

ELECTRICAL ABBREVIATIONS AND

GENERAL NOTES

18 & 60

FCA - REPLACE MECHANICAL

SYSTEMS IN BUILDING 18 & 60

TL GG Drawing # 51 of 77

P POLE

PA PUBLIC ADDRESS

PB PULL BOX OR PANEL BOARD

PBPU PREFABRICATED BEDSIDE PATIENT UNIT

PCB POLYCHLORINATED BIPHENYL

PEC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PNL PANEL

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

RCP REFLECTED CEILING PLAN

REC RECESSED

RECPT RECEPTACLE

REQ REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

SCC SHORT CIRCUIT CAPACITY

SD SMOKE DETECTOR

SES SERVICE ENTRANCE SECTION

SF SQUARE FOOT (FEET)

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SPEC SPECIFICATION

SPST SINGLE POLE, SINGLE THROW

SURF SURFACE

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

TEL TELEPHONE

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

UFD UNDERFLOOR DUCT

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

VA VOLT-AMPERE

VAR VOLT-AMPERE REACTIVE

VFD VARIABLE FREQUENCY DRIVE

VOLT VOLTAGE

W WATT

WH WATER HEATER

WP WEATHERPROOF

XFER TRANSFER

XFMR TRANSFORMER

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

EPRF EXPLOSION PROOF

ESMT EASEMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EXST EXISTING

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FABL FIRE ALARM BELL

FABX FIRE ALARM BOX

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FIXT FIXTURE

FLA FULL LOAD AMPS

FLEX FLEXIBLE METALLIC CONDUIT

FLT FLOODLIGHT

FLUOR FLUORESCENT

FLUOR FIXT FLUORESCENT FIXTURE

FOUTT TELEPHONE FLOOR OUTLET

FP FIRE PROTECTION

FT FEET OR FOOT

FU SW FUSED SWITCH

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

G OR GND ELECTRICAL GROUND

GC GENERAL CONTRACTOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GTB GROUND TERMINAL BOX

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HZ HERTZ

IESNA ILLUMINATION ENGINEERING SOCIETY OF NORTH

AMERICA

IMC INTERMEDIATE METAL CONDUIT

INCAND INCANDESCENT

IR INFRARED

IWH INSTANTANEOUS WATER HEATER

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT-AMPERE

KVAH KILOVOLT-AMPERE PER HOUR

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

KWHM KILOWATT HOUR METER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LM LUMEN

LP LIGHT POLE

LPS LOW PRESSURE SODIUM

LRA LOCKED ROTOR AMPS

LT LIGHT

LTG LIGHTING

LTG PNL LIGHTING PANEL

LTNG LIGHTNING

LV LOW VOLTAGE

M MOTOR

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC METAL-CLAD

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MG MOTOR GENERATOR

MH MANHOLE

MIN MINIMUM

MLO MAIN LUGS ONLY

MOCP MAXIMUM OVERCURRENT PROTECTION

MS MOTOR SWITCH

MT MOUNT

MTD MOUNTED

MTG MOUNTING

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

MVA MEGAVOLT-AMPERE

MW MEGAWATT

N NEW

NA NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRIC CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NEUT OR N NEUTRAL

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NS NO SCALE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OL OVERLOAD

1P SINGLE POLE

1PH SINGLE PHASE

2/C TWO-CONDUCTOR

3/C THREE-CONDUCTOR

3PH THREE PHASE

4/C FOUR-CONDUCTOR

4W FOUR WIRE

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT / ENGINEER

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR ARMORED CABLE

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT OR ADJOINING

ADO AUTOMATIC DOOR OPENER

AF AMPERE FRAME OR AMP FUSE

AFC ABOVE FINISHED COUNTER, AUTOMATIC

FREQUENCY CONTROL, OR AVAILABLE FAULT

CURRENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AH AMPERE-HOUR

AHJ AUTHORITY HAVING JURISDICTION

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE

AMB OR A AMBIENT

AMP AMPERE

ARCH ARCHITECT

ASC AMPS SHORT CIRCUIT

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

BAT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISHED FLOOR

BIL BASIC INSULATION LEVEL

BLDG BUILDING

BPIP BOILER PLANT INSTRUMENTATION PANEL

BRKR BREAKER

BYP BYPASS

C CONDUIT

CAB CABINET

CALC CALCULATE

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

CD CANDELA OR CONSTRUCTION DOCUMENTS

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED / CONTRACTOR

INSTALLED

CF/OI CONTRACTOR FURNISHED / OWNER INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CHW CHILLED WATER

CHWP CHILLED WATER PUMP

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CLF CURRENT LIMITING FUSE

CLG CEILING

CMU CONCRETE MASONRY UNIT

CO CONTRACTING OFFICER

COAX COAX CABLE

COMM COMMUNICATION

COMPT COMPARTMENT

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER'S REPRESENTATIVE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CU COPPER

CU FT CUBIC FEET

CUR CURRENT

DB DECIBEL

DC DIRECT CURRENT

DCP DIMMER CONTROL PANEL

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DIAG DIAGRAM

DISC DISCONNECT

DISTR DISTRIBUTION

DISTR PNL DISTRIBUTION PANEL

DMR SW DIMMER SWITCH

DN DOWN

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DRSW DOOR SWITCH

DS DISCONNECT SWITCH

DWG DRAWING

E EXISTING

EL ELEVATION

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMCP EMERGENCY MONITORING CONTROL PANEL

ELECTRICAL ABBREVIATIONS

rwwhe Image

CARD READERBRANCH CIRCUIT HOMERUN. LINES INDICATE NUMBER OF

CIRCUITS,NEUTRAL, AND SWITCH LEG CONDUCTORS. ONE

SEPARATE GREEN GROUNDING CONDUCTOR SHALL BE

PROVIDED FOR EACH HOMERUN; NOT SHOWN

P

A bx

A b x

A b x

A b x

DT

ELECTRICAL SYMBOLS - DIAGRAM COMMUNICATION SYMBOLS: ELECTRICAL SYMBOLS - LIGHTING PLANELECTRICAL SYMBOLS - POWER PLAN

SWITCH, MULTIPOSITION

SWITCH, NORMALLY CLOSED FLOAT

SWITCH, NORMALLY CLOSED FOOT OPERATED

SWITCH, NORMALLY CLOSED LIMIT

SWITCH, NORMALLY CLOSED TIME DELAY

SWITCH, NORMALLY CLOSED TEMPERATURE

ACTIVATED

SWITCH, NORMALLY OPEN FLOAT

SWITCH, NORMALLY OPEN LIMIT

SWITCH, NORMALLY OPEN TEMPERATURE

ACTIVATED

MOTOR, SINGLE-PHASE

MOTOR, THREE-PHASE

DELTA CONNECTION

TRANSFORMER

WYE CONNECTION

PULL BOX

PRESSURE SWITCH-CLOSE ON INCREASE

PRESSURE SWITCH-OPEN ON INCREASE

MANHOLE

TIME CLOCK

VE…

This is the start of the file's text. The full file is on GovTribe.