36C25518R0485-016.pdf

PDF 2 MB Posted

Attached to
Demolish Sextro Warehouse, John Cochran 657-CSI-603
Solicitation number
36C25518R0485
Issued by

About this file

36C25518R0485 657-CSI-603JC Dwgs Arch.pdf

View the file

Other files

File Type Posted
36C25518R0485-019.pdf PDF
36C25518R0485-014.pdf PDF
36C25518R0485-012.docx DOCX document
36C25518R0485-020.pdf PDF
36C25518R0485-013.pdf PDF
36C25518R0485-018.pdf PDF
36C25518R0485-017.pdf PDF
36C25518R0485-015.pdf PDF
36C25518R0485-022.pdf PDF
36C25518R0485-021.pdf PDF
36C25518R0485-011.docx DOCX document
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WINDSOR PL.

BELL AVE.

(A

LL

E Y

N . S

P R

IN

G

A V

E

N . S

PR

IN

G A

VE

EXISTING

STRUCTURE

EXISTING VA CAMPUS

EXISTING

STRUCTURE

EXISTING RESIDENCES

N . G

R A

N D

B

LV

D

SEXTRO WAREHOUSE

137,884 SF

AD-003

AD-003

1. DRAWINGS TO BE TAKEN AS PART OF A COMPLETE DOCUMENT

SET. CONTRACTOR TO CONFIRM ALL ITEMS REQUIRED TO BE

DEMOLISHED AND EXTENT OF DEMOLITION BASED UPON THE

OVERALL INTENT OF THE ENTIRE DOCUMENT SET.

2. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGININNG ANY

DEMOLITION WORK TO CONFIRM ACCURACY IN THE DRAWINGS.

REPORT ANY DISCREPANCIES TO CONTRACTING OFFICER.

DO NOT SCALE THE DRAWINGS. ALL DIMENSIONS SHOWN ON

DEMOLITION PLANS ARE APPROXIMATEFIELD VERIFY ALL

DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.

3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS

PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS

AT ALL TIMES. ERECT BARRICADES AND WARNING SIGNS TO

DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION

WORK.

4. DURING DEMOLITION, PROVIDE PROTECTION FOR ALL EXISTING

STRUCTURES AND IMPROVEMENTS TO REMAIN IN PLACE DURING THE

RENOVATION WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND

REPAIR ANY DAMAGE TO ADJACENT FACILITIES TO MATCH EXISTING.

ALL DEBRIS CREATED BY DEMOLITION SHOULD BE CONTAINED TO THE

PROJECT SITE.

5. ANY DAMAGE CAUSED TO THE SURROUNDING BUILDINGS AND

PROPERTY OR OWNER EQUIPMENT SHALL BE REPAIRED OR

REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL

COST TO THE OWNER.

6. ALL ITEMS WITHIN THE BUILDING ENVELOPE SHALL BE REMOVED

IN THEIR ENTIRETY INCLUDING RELATED COMPONENTS.

7. CONTRACTOR TO DEMO ALL FIXTURES, CEILINGS, MECHANICAL,

PLUMBING, ELECTRICAL COMMUNICATIONS, FIRE PROTECTION AND

FIRE ALARM SYSTEMS AS REQUIRED TO COMPLETE THE SCOPE OF

WORK OUTLINED WITHIN THE CONSTRUCTION DOCUMENTS.

8. DISCONNECT ALL UTILITIES AND ELECTRICAL POWER PRIOR TO

DEMOLITION. REF. CIVIL / MEP

GENERAL DEMOLITION NOTES

SPUR DESIGN

320 NW 10TH ST., SUITE A

OKLAHOMA CITY, OK 73103

PHONE: 405.842.6100

CERTIFICATE OF AUTHORITY:

MO #2012034754(ARCHITECTURE)

OATES ASSOCIATES

100 LANTER COURT, SUITE

COLLINSVILLE, IL 62234

PHONE: 618.345.2200

CERTIFICATE OF

AUTHORITY:

MO #001166 (ENGINEERING)

GLASPER PROFESSIONAL SERVICES,

INC.

13100 MANCHESTER RD., SUITE 85

ST. LOUIS, MO 63131

PH: 314.966.9987

CERTIFICATE OF AUTHORITY:

MO #2011027103 (LAND SURVEYING)

SPUR DESIGN

11020 KING ST., SUITE 350

OVERLAND PARK, KS 66210

PH: 913.369.7200

CERTIFICATE OF AUTHORITY:

MO #2014031351

(ENGINEERING)

INTERIM SUBMITTAL

NOT FOR

CONSTRUCTION PURPOSES

o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t

1 2 3 4 5 6 7 8 9

A

VA FORM 08-6231

Veterans

Health

Administration

1 2 3 4 5 6 7 8 9

B

C

D

E

F

A

B

C

D

E

F

BID DOCUMENTS

Drawing Number

Project Number

Date

-OF-

Project Title

Building Number

Location

Checked Drawn

Approved: Project Director

Drawing Title

No.

VASTLHCS DEMOLISH

SEXTRO WAREHOUSE

JOHN COCHRAN DIVISION

657-CSI-603JC

Dwg.

CONSULTANTS: PRIME CONSULTANT:

ARCHITECT:

Date Revisions

CIVIL ENGINEER: LAND SURVEYING:

ST. LOUIS, MO

SETH CAVIN A.I.A.

MO# 2002021688 (ARCH)

04/25/2018

ELECTRICAL ENGINEER:

DEMOLITION SITE PLAN

JEH JEH

30-AD-001

42 54

N

1" = 40'-0"

DEMOLITION SITE PLAN

EXTENTS OF DEMOLITION

SMOKE STACK

P R

O P

E R

T Y

L

IN

E

PROPERTY LINE

P R

O P

E R

T Y

LIN

E

P R

O P

E R

T Y

L

IN

E

UP

DN

DN

DN

DN

UP

UP

DN

H

G

F

E

D

C

B

A

1234567891011121314151819202122

J

K

I

23 1617

37' - 3" 105' - 10 1/2" 42' - 10 1/2" 106' - 3" 191' - 3"

483' - 6"

FURNACE

TYP.

TYP.

M A

T C

H L

IN

E

AD-003

AD-003

DOCK

LOADING

DOCK

LOADING

DOCK

LOADING

DOCK

LOADING

DOCK

H

G

F

E

D

C

B

A

123456789101112131415181920212223242526272829303132

T

S

R

Q

P

O

N

M

L

161734

V

12345678910111213141518192021222324252627282930313233 16173435

1. DRAWINGS TO BE TAKEN AS PART OF A COMPLETE DOCUMENT

SET. CONTRACTOR TO CONFIRM ALL ITEMS REQUIRED TO BE

DEMOLISHED AND EXTENT OF DEMOLITION BASED UPON THE

OVERALL INTENT OF THE ENTIRE DOCUMENT SET.

2. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGININNG ANY

DEMOLITION WORK TO CONFIRM ACCURACY IN THE DRAWINGS.

REPORT ANY DISCREPANCIES TO CONTRACTING OFFICER.

DO NOT SCALE THE DRAWINGS. ALL DIMENSIONS SHOWN ON

DEMOLITION PLANS ARE APPROXIMATEFIELD VERIFY ALL

DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.

3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS

PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS

AT ALL TIMES. ERECT BARRICADES AND WARNING SIGNS TO

DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION

WORK.

4. DURING DEMOLITION, PROVIDE PROTECTION FOR ALL EXISTING

STRUCTURES AND IMPROVEMENTS TO REMAIN IN PLACE DURING THE

RENOVATION WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND

REPAIR ANY DAMAGE TO ADJACENT FACILITIES TO MATCH EXISTING.

ALL DEBRIS CREATED BY DEMOLITION SHOULD BE CONTAINED TO THE

PROJECT SITE.

5. ANY DAMAGE CAUSED TO THE SURROUNDING BUILDINGS AND

PROPERTY OR OWNER EQUIPMENT SHALL BE REPAIRED OR

REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL

COST TO THE OWNER.

6. ALL ITEMS WITHIN THE BUILDING ENVELOPE SHALL BE REMOVED

IN THEIR ENTIRETY INCLUDING RELATED COMPONENTS.

7. CONTRACTOR TO DEMO ALL FIXTURES, CEILINGS, MECHANICAL,

PLUMBING, ELECTRICAL COMMUNICATIONS, FIRE PROTECTION AND

FIRE ALARM SYSTEMS AS REQUIRED TO COMPLETE THE SCOPE OF

WORK OUTLINED WITHIN THE CONSTRUCTION DOCUMENTS.

8. DISCONNECT ALL UTILITIES AND ELECTRICAL POWER PRIOR TO

DEMOLITION. REF. CIVIL / MEP

GENERAL DEMOLITION NOTES

1. REMOVE EXISTING BRICK AND CMU WALLS, CONCRETE FLOOR SLAB, FOOTINGS, AND

ROOF.

2. REMOVE EXISTING WINDOWS, DOORS, AND OTHER OPENINGS THROUGHOUT.

3. REMOVE EXISTING STACK, FURNACE, AND COAL CHUTE.

KEYED NOTES - DEMOLITION

SPUR DESIGN

320 NW 10TH ST., SUITE A

OKLAHOMA CITY, OK 73103

PHONE: 405.842.6100

CERTIFICATE OF AUTHORITY:

MO #2012034754(ARCHITECTURE)

OATES ASSOCIATES

100 LANTER COURT, SUITE

COLLINSVILLE, IL 62234

PHONE: 618.345.2200

CERTIFICATE OF

AUTHORITY:

MO #001166 (ENGINEERING)

GLASPER PROFESSIONAL SERVICES,

INC.

13100 MANCHESTER RD., SUITE 85

ST. LOUIS, MO 63131

PH: 314.966.9987

CERTIFICATE OF AUTHORITY:

MO #2011027103 (LAND SURVEYING)

SPUR DESIGN

11020 KING ST., SUITE 350

OVERLAND PARK, KS 66210

PH: 913.369.7200

CERTIFICATE OF AUTHORITY:

MO #2014031351

(ENGINEERING)

INTERIM SUBMITTAL

NOT FOR

CONSTRUCTION PURPOSES

o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t

1 2 3 4 5 6 7 8 9

A

VA FORM 08-6231

Veterans

Health

Administration

1 2 3 4 5 6 7 8 9

B

C

D

E

F

A

B

C

D

E

F

BID DOCUMENTS

Drawing Number

Project Number

Date

-OF-

Project Title

Building Number

Location

Checked Drawn

Approved: Project Director

Drawing Title

No.

VASTLHCS DEMOLISH

SEXTRO WAREHOUSE

JOHN COCHRAN DIVISION

657-CSI-603JC

Dwg.

CONSULTANTS: PRIME CONSULTANT:

ARCHITECT:

Date Revisions

CIVIL ENGINEER: LAND SURVEYING:

ST. LOUIS, MO

SETH CAVIN A.I.A.

MO# 2002021688 (ARCH)

04/25/2018

ELECTRICAL ENGINEER:

LEVEL 1A DEMOLITION PLAN

JEH JEH

30-AD-002

43 54

N

1/16" = 1'-0"

LEVEL 1A DEMOLITION PLAN

1/64" = 1'-0"

KEY PLAN 1A

1/64" = 1'-0"

SOUTH KEY ELEVATION 1A

UP

UP

UP

UP

H

G

F

E

D

C

B

A

1819202122

J

K

I

23242526272829303132

T

S

R

Q

P

O

N

M

L

V

30-AD-004

30-AD-004

EXISTING COAL CHUTE

FURNACE

585' - 4 1/2"

63' - 5"

42' - 4 1/2" 101' - 6" 74' - 6" 260' - 9" 106' - 3"

TYP.

TYP.

M A

T C

H L

IN

E

LOADING

DOCK

LOADING

DOCK

LOADING

DOCK

LOADING

DOCK

H

G

F

E

D

C

B

A

1234567891011121314151819202122

J

K

I

23242526272829303132

T

S

R

Q

P

O

N

M

L

161734

V

12345678910111213141518192021222324252627282930313233 16173435

1. DRAWINGS TO BE TAKEN AS PART OF A COMPLETE DOCUMENT

SET. CONTRACTOR TO CONFIRM ALL ITEMS REQUIRED TO BE

DEMOLISHED AND EXTENT OF DEMOLITION BASED UPON THE

OVERALL INTENT OF THE ENTIRE DOCUMENT SET.

2. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGININNG ANY

DEMOLITION WORK TO CONFIRM ACCURACY IN THE DRAWINGS.

REPORT ANY DISCREPANCIES TO CONTRACTING OFFICER.

DO NOT SCALE THE DRAWINGS. ALL DIMENSIONS SHOWN ON

DEMOLITION PLANS ARE APPROXIMATEFIELD VERIFY ALL

DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.

3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS

PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS

AT ALL TIMES. ERECT BARRICADES AND WARNING SIGNS TO

DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION

WORK.

4. DURING DEMOLITION, PROVIDE PROTECTION FOR ALL EXISTING

STRUCTURES AND IMPROVEMENTS TO REMAIN IN PLACE DURING THE

RENOVATION WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND

REPAIR ANY DAMAGE TO ADJACENT FACILITIES TO MATCH EXISTING.

ALL DEBRIS CREATED BY DEMOLITION SHOULD BE CONTAINED TO THE

PROJECT SITE.

5. ANY DAMAGE CAUSED TO THE SURROUNDING BUILDINGS AND

PROPERTY OR OWNER EQUIPMENT SHALL BE REPAIRED OR

REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL

COST TO THE OWNER.

6. ALL ITEMS WITHIN THE BUILDING ENVELOPE SHALL BE REMOVED

IN THEIR ENTIRETY INCLUDING RELATED COMPONENTS.

7. CONTRACTOR TO DEMO ALL FIXTURES, CEILINGS, MECHANICAL,

PLUMBING, ELECTRICAL COMMUNICATIONS, FIRE PROTECTION AND

FIRE ALARM SYSTEMS AS REQUIRED TO COMPLETE THE SCOPE OF

WORK OUTLINED WITHIN THE CONSTRUCTION DOCUMENTS.

8. DISCONNECT ALL UTILITIES AND ELECTRICAL POWER PRIOR TO

DEMOLITION. REF. CIVIL / MEP

GENERAL DEMOLITION NOTES

1. REMOVE EXISTING BRICK AND CMU WALLS, CONCRETE FLOOR SLAB, FOOTINGS, AND

ROOF.

2. REMOVE EXISTING WINDOWS, DOORS, AND OTHER OPENINGS THROUGHOUT.

3. REMOVE EXISTING STACK, FURNACE, AND COAL CHUTE.

KEYED NOTES - DEMOLITION

SPUR DESIGN

320 NW 10TH ST., SUITE A

OKLAHOMA CITY, OK 73103

PHONE: 405.842.6100

CERTIFICATE OF AUTHORITY:

MO #2012034754(ARCHITECTURE)

OATES ASSOCIATES

100 LANTER COURT, SUITE

COLLINSVILLE, IL 62234

PHONE: 618.345.2200

CERTIFICATE OF

AUTHORITY:

MO #001166 (ENGINEERING)

GLASPER PROFESSIONAL SERVICES,

INC.

13100 MANCHESTER RD., SUITE 85

ST. LOUIS, MO 63131

PH: 314.966.9987

CERTIFICATE OF AUTHORITY:

MO #2011027103 (LAND SURVEYING)

SPUR DESIGN

11020 KING ST., SUITE 350

OVERLAND PARK, KS 66210

PH: 913.369.7200

CERTIFICATE OF AUTHORITY:

MO #2014031351

(ENGINEERING)

INTERIM SUBMITTAL

NOT FOR

CONSTRUCTION PURPOSES

o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t

1 2 3 4 5 6 7 8 9

A

VA FORM 08-6231

Veterans

Health

Administration

1 2 3 4 5 6 7 8 9

B

C

D

E

F

A

B

C

D

E

F

BID DOCUMENTS

Drawing Number

Project Number

Date

-OF-

Project Title

Building Number

Location

Checked Drawn

Approved: Project Director

Drawing Title

No.

VASTLHCS DEMOLISH

SEXTRO WAREHOUSE

JOHN COCHRAN DIVISION

657-CSI-603JC

Dwg.

CONSULTANTS: PRIME CONSULTANT:

ARCHITECT:

Date Revisions

CIVIL ENGINEER: LAND SURVEYING:

ST. LOUIS, MO

SETH CAVIN A.I.A.

MO# 2002021688 (ARCH)

04/25/2018

ELECTRICAL ENGINEER:

LEVEL 1B DEMOLITION PLAN

JEH JEH

30-AD-003

44 54

N

1/16" = 1'-0"

LEVEL 1B DEMOLITION PLAN

1/64" = 1'-0"

DEMOLITION KEY PLAN 1B

1/64" = 1'-0"

SOUTH KEY ELEVATION 1B

LEVEL 1A

100' - 0"

12345678910111213141518192021222324252627282930313233 1617

LEVEL 1B

88' - 0"

30-AD-004

LEVEL 1A

100' - 0"

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 3316 17

LEVEL 1B

88' - 0"

34 35

1. DRAWINGS TO BE TAKEN AS PART OF A COMPLETE DOCUMENT

SET. CONTRACTOR TO CONFIRM ALL ITEMS REQUIRED TO BE

DEMOLISHED AND EXTENT OF DEMOLITION BASED UPON THE

OVERALL INTENT OF THE ENTIRE DOCUMENT SET.

2. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGININNG ANY

DEMOLITION WORK TO CONFIRM ACCURACY IN THE DRAWINGS.

REPORT ANY DISCREPANCIES TO CONTRACTING OFFICER.

DO NOT SCALE THE DRAWINGS. ALL DIMENSIONS SHOWN ON

DEMOLITION PLANS ARE APPROXIMATEFIELD VERIFY ALL

DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.

3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS

PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS

AT ALL TIMES. ERECT BARRICADES AND WARNING SIGNS TO

DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION

WORK.

4. DURING DEMOLITION, PROVIDE PROTECTION FOR ALL EXISTING

STRUCTURES AND IMPROVEMENTS TO REMAIN IN PLACE DURING THE

RENOVATION WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND

REPAIR ANY DAMAGE TO ADJACENT FACILITIES TO MATCH EXISTING.

ALL DEBRIS CREATED BY DEMOLITION SHOULD BE CONTAINED TO THE

PROJECT SITE.

5. ANY DAMAGE CAUSED TO THE SURROUNDING BUILDINGS AND

PROPERTY OR OWNER EQUIPMENT SHALL BE REPAIRED OR

REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL

COST TO THE OWNER.

6. ALL ITEMS WITHIN THE BUILDING ENVELOPE SHALL BE REMOVED

IN THEIR ENTIRETY INCLUDING RELATED COMPONENTS.

7. CONTRACTOR TO DEMO ALL FIXTURES, CEILINGS, MECHANICAL,

PLUMBING, ELECTRICAL COMMUNICATIONS, FIRE PROTECTION AND

FIRE ALARM SYSTEMS AS REQUIRED TO COMPLETE THE SCOPE OF

WORK OUTLINED WITHIN THE CONSTRUCTION DOCUMENTS.

8. DISCONNECT ALL UTILITIES AND ELECTRICAL POWER PRIOR TO

DEMOLITION. REF. CIVIL / MEP

GENERAL DEMOLITION NOTES

1. REMOVE EXISTING BRICK AND CMU WALLS, CONCRETE FLOOR SLAB, FOOTINGS, AND

ROOF.

2. REMOVE EXISTING WINDOWS, DOORS, AND OTHER OPENINGS THROUGHOUT.

3. REMOVE EXISTING STACK, FURNACE, AND COAL CHUTE.

KEYED NOTES - DEMOLITION

LEVEL 1A

100' - 0"

LEVEL 1B

88' - 0"

F

IE

L D

V E

R

IF

Y

F

IE

L D

V E

R

IF

Y

SPUR DESIGN

320 NW 10TH ST., SUITE A

OKLAHOMA CITY, OK 73103

PHONE: 405.842.6100

CERTIFICATE OF AUTHORITY:

MO #2012034754(ARCHITECTURE)

OATES ASSOCIATES

100 LANTER COURT, SUITE

COLLINSVILLE, IL 62234

PHONE: 618.345.2200

CERTIFICATE OF

AUTHORITY:

MO #001166 (ENGINEERING)

GLASPER PROFESSIONAL SERVICES,

INC.

13100 MANCHESTER RD., SUITE 85

ST. LOUIS, MO 63131

PH: 314.966.9987

CERTIFICATE OF AUTHORITY:

MO #2011027103 (LAND SURVEYING)

SPUR DESIGN

11020 KING ST., SUITE 350

OVERLAND PARK, KS 66210

PH: 913.369.7200

CERTIFICATE OF AUTHORITY:

MO #2014031351

(ENGINEERING)

INTERIM SUBMITTAL

NOT FOR

CONSTRUCTION PURPOSES

o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t

1 2 3 4 5 6 7 8 9

A

VA FORM 08-6231

Veterans

Health

Administration

1 2 3 4 5 6 7 8 9

B

C

D

E

F

A

B

C

D

E

F

BID DOCUMENTS

Drawing Number

Project Number

Date

-OF-

Project Title

Building Number

Location

Checked Drawn

Approved: Project Director

Drawing Title

No.

VASTLHCS DEMOLISH

SEXTRO WAREHOUSE

JOHN COCHRAN DIVISION

657-CSI-603JC

Dwg.

CONSULTANTS: PRIME CONSULTANT:

ARCHITECT:

Date Revisions

CIVIL ENGINEER: LAND SURVEYING:

ST. LOUIS, MO

SETH CAVIN A.I.A.

MO# 2002021688 (ARCH)

04/25/2018

ELECTRICAL ENGINEER:

DEMO ELEVATIONS

JEH JEH

30-AD-004

45 54

1" = 30'-0"

SOUTH ELEVATION

1" = 30'-0"

NORTH ELEVATION

1/8" = 1'-0"

SOUTH ELEVATION - SMOKESTACK

_01_65~1
_02_65~1
1 HA-01
Sheets and Views
1 HA-01
PLOT
2 HA-02
Sheets and Views
2 HA-02
3 HA-03
Sheets and Views
3 HA-03
PLOT
4 HA-04
Sheets and Views
4 HA-04
5 HA-05
Sheets and Views
5 HA-05
6 HA-06
Sheets and Views
6 HA-06
PLOT
7 HA-07
Sheets and Views
7 HA-07
8 HA-08
Sheets and Views
8 HA-08
PLOT
9 HA-09
Sheets and Views
9 HA-09
_03_65~1
12_657-CSI-603JC C0.1
13_657-CSI-603JC C0.2
14_657-CSI-603JC C1.1
15_657-CSI-603JC C2.1
16_657-CSI-603JC C3.1
17_657-CSI-603JC C3.1A
18_657-CSI-603JC C3.2
19_657-CSI-603JC C3.3
20_657-CSI-603JC C3.4
21_657-CSI-603JC C3.5
22_657-CSI-603JC C3.6
23_657-CSI-603JC C3.7
24_657-CSI-603JC C3.8
25_657-CSI-603JC C4.1
26_657-CSI-603JC C4.2
27_657-CSI-603JC C4.3
28_657-CSI-603JC C4.4
29_657-CSI-603JC C5.1
30_657-CSI-603JC C5.2
31_657-CSI-603JC C5.3
32_657-CSI-603JC C6.1
33_657-CSI-603JC C7.1
34_657-CSI-603JC C8.1
35_657-CSI-603JC C8.2
_04_65~1
36_657-CSI-603JC SD0.1
37_657-CSI-603JC SD1.1
38_657-CSI-603JC SD1.2
39_657-CSI-603JC SD1.3
40_657-CSI-603JC SD1.4
41_657-CSI-603JC SD1.5
_05_65~1
Sheets
30-AD-001 - DEMOLITION SITE PLAN
30-AD-002 - LEVEL 1A DEMOLITION PLAN
30-AD-003 - LEVEL 1B DEMOLITION PLAN
30-AD-004 - DEMO ELEVATIONS
_06_VA~1
46_30-ES000-Electrical Legend
47_30-ED101-Electrical Site Demolition Plan
48_30-ES101-Electrical Site Plan
49_30-ES501-Electrical Details
50_30-ES601-Electrical One-Line Diagram
_07_VA~1
51_30-TS000-Technology Legend
52_30-TS101-Technology Site Plan
53_30-TS501-Technology Details
54_30-TS601-Technology Riser Diagrams

File details come from the government source that posted it.