WINDSOR PL.
BELL AVE.
(A
LL
E Y
N . S
P R
IN
G
A V
E
N . S
PR
IN
G A
VE
EXISTING
STRUCTURE
EXISTING VA CAMPUS
EXISTING
STRUCTURE
EXISTING RESIDENCES
N . G
R A
N D
B
LV
D
SEXTRO WAREHOUSE
137,884 SF
AD-003
AD-003
1. DRAWINGS TO BE TAKEN AS PART OF A COMPLETE DOCUMENT
SET. CONTRACTOR TO CONFIRM ALL ITEMS REQUIRED TO BE
DEMOLISHED AND EXTENT OF DEMOLITION BASED UPON THE
OVERALL INTENT OF THE ENTIRE DOCUMENT SET.
2. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGININNG ANY
DEMOLITION WORK TO CONFIRM ACCURACY IN THE DRAWINGS.
REPORT ANY DISCREPANCIES TO CONTRACTING OFFICER.
DO NOT SCALE THE DRAWINGS. ALL DIMENSIONS SHOWN ON
DEMOLITION PLANS ARE APPROXIMATEFIELD VERIFY ALL
DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS
PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS
AT ALL TIMES. ERECT BARRICADES AND WARNING SIGNS TO
DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION
WORK.
4. DURING DEMOLITION, PROVIDE PROTECTION FOR ALL EXISTING
STRUCTURES AND IMPROVEMENTS TO REMAIN IN PLACE DURING THE
RENOVATION WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FACILITIES TO MATCH EXISTING.
ALL DEBRIS CREATED BY DEMOLITION SHOULD BE CONTAINED TO THE
PROJECT SITE.
5. ANY DAMAGE CAUSED TO THE SURROUNDING BUILDINGS AND
PROPERTY OR OWNER EQUIPMENT SHALL BE REPAIRED OR
REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL
COST TO THE OWNER.
6. ALL ITEMS WITHIN THE BUILDING ENVELOPE SHALL BE REMOVED
IN THEIR ENTIRETY INCLUDING RELATED COMPONENTS.
7. CONTRACTOR TO DEMO ALL FIXTURES, CEILINGS, MECHANICAL,
PLUMBING, ELECTRICAL COMMUNICATIONS, FIRE PROTECTION AND
FIRE ALARM SYSTEMS AS REQUIRED TO COMPLETE THE SCOPE OF
WORK OUTLINED WITHIN THE CONSTRUCTION DOCUMENTS.
8. DISCONNECT ALL UTILITIES AND ELECTRICAL POWER PRIOR TO
DEMOLITION. REF. CIVIL / MEP
GENERAL DEMOLITION NOTES
SPUR DESIGN
320 NW 10TH ST., SUITE A
OKLAHOMA CITY, OK 73103
PHONE: 405.842.6100
CERTIFICATE OF AUTHORITY:
MO #2012034754(ARCHITECTURE)
OATES ASSOCIATES
100 LANTER COURT, SUITE
COLLINSVILLE, IL 62234
PHONE: 618.345.2200
CERTIFICATE OF
AUTHORITY:
MO #001166 (ENGINEERING)
GLASPER PROFESSIONAL SERVICES,
INC.
13100 MANCHESTER RD., SUITE 85
ST. LOUIS, MO 63131
PH: 314.966.9987
CERTIFICATE OF AUTHORITY:
MO #2011027103 (LAND SURVEYING)
SPUR DESIGN
11020 KING ST., SUITE 350
OVERLAND PARK, KS 66210
PH: 913.369.7200
CERTIFICATE OF AUTHORITY:
MO #2014031351
(ENGINEERING)
INTERIM SUBMITTAL
NOT FOR
CONSTRUCTION PURPOSES
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM 08-6231
Veterans
Health
Administration
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
BID DOCUMENTS
Drawing Number
Project Number
Date
-OF-
Project Title
Building Number
Location
Checked Drawn
Approved: Project Director
Drawing Title
No.
VASTLHCS DEMOLISH
SEXTRO WAREHOUSE
JOHN COCHRAN DIVISION
657-CSI-603JC
Dwg.
CONSULTANTS: PRIME CONSULTANT:
ARCHITECT:
Date Revisions
CIVIL ENGINEER: LAND SURVEYING:
ST. LOUIS, MO
SETH CAVIN A.I.A.
MO# 2002021688 (ARCH)
04/25/2018
ELECTRICAL ENGINEER:
DEMOLITION SITE PLAN
JEH JEH
30-AD-001
42 54
N
1" = 40'-0"
DEMOLITION SITE PLAN
EXTENTS OF DEMOLITION
SMOKE STACK
P R
O P
E R
T Y
L
IN
E
PROPERTY LINE
P R
O P
E R
T Y
LIN
E
P R
O P
E R
T Y
L
IN
E
UP
DN
DN
DN
DN
UP
UP
DN
H
G
F
E
D
C
B
A
1234567891011121314151819202122
J
K
I
23 1617
37' - 3" 105' - 10 1/2" 42' - 10 1/2" 106' - 3" 191' - 3"
483' - 6"
FURNACE
TYP.
TYP.
M A
T C
H L
IN
E
AD-003
AD-003
DOCK
LOADING
DOCK
LOADING
DOCK
LOADING
DOCK
LOADING
DOCK
H
G
F
E
D
C
B
A
123456789101112131415181920212223242526272829303132
T
S
R
Q
P
O
N
M
L
161734
V
12345678910111213141518192021222324252627282930313233 16173435
1. DRAWINGS TO BE TAKEN AS PART OF A COMPLETE DOCUMENT
SET. CONTRACTOR TO CONFIRM ALL ITEMS REQUIRED TO BE
DEMOLISHED AND EXTENT OF DEMOLITION BASED UPON THE
OVERALL INTENT OF THE ENTIRE DOCUMENT SET.
2. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGININNG ANY
DEMOLITION WORK TO CONFIRM ACCURACY IN THE DRAWINGS.
REPORT ANY DISCREPANCIES TO CONTRACTING OFFICER.
DO NOT SCALE THE DRAWINGS. ALL DIMENSIONS SHOWN ON
DEMOLITION PLANS ARE APPROXIMATEFIELD VERIFY ALL
DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS
PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS
AT ALL TIMES. ERECT BARRICADES AND WARNING SIGNS TO
DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION
WORK.
4. DURING DEMOLITION, PROVIDE PROTECTION FOR ALL EXISTING
STRUCTURES AND IMPROVEMENTS TO REMAIN IN PLACE DURING THE
RENOVATION WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FACILITIES TO MATCH EXISTING.
ALL DEBRIS CREATED BY DEMOLITION SHOULD BE CONTAINED TO THE
PROJECT SITE.
5. ANY DAMAGE CAUSED TO THE SURROUNDING BUILDINGS AND
PROPERTY OR OWNER EQUIPMENT SHALL BE REPAIRED OR
REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL
COST TO THE OWNER.
6. ALL ITEMS WITHIN THE BUILDING ENVELOPE SHALL BE REMOVED
IN THEIR ENTIRETY INCLUDING RELATED COMPONENTS.
7. CONTRACTOR TO DEMO ALL FIXTURES, CEILINGS, MECHANICAL,
PLUMBING, ELECTRICAL COMMUNICATIONS, FIRE PROTECTION AND
FIRE ALARM SYSTEMS AS REQUIRED TO COMPLETE THE SCOPE OF
WORK OUTLINED WITHIN THE CONSTRUCTION DOCUMENTS.
8. DISCONNECT ALL UTILITIES AND ELECTRICAL POWER PRIOR TO
DEMOLITION. REF. CIVIL / MEP
GENERAL DEMOLITION NOTES
1. REMOVE EXISTING BRICK AND CMU WALLS, CONCRETE FLOOR SLAB, FOOTINGS, AND
ROOF.
2. REMOVE EXISTING WINDOWS, DOORS, AND OTHER OPENINGS THROUGHOUT.
3. REMOVE EXISTING STACK, FURNACE, AND COAL CHUTE.
KEYED NOTES - DEMOLITION
SPUR DESIGN
320 NW 10TH ST., SUITE A
OKLAHOMA CITY, OK 73103
PHONE: 405.842.6100
CERTIFICATE OF AUTHORITY:
MO #2012034754(ARCHITECTURE)
OATES ASSOCIATES
100 LANTER COURT, SUITE
COLLINSVILLE, IL 62234
PHONE: 618.345.2200
CERTIFICATE OF
AUTHORITY:
MO #001166 (ENGINEERING)
GLASPER PROFESSIONAL SERVICES,
INC.
13100 MANCHESTER RD., SUITE 85
ST. LOUIS, MO 63131
PH: 314.966.9987
CERTIFICATE OF AUTHORITY:
MO #2011027103 (LAND SURVEYING)
SPUR DESIGN
11020 KING ST., SUITE 350
OVERLAND PARK, KS 66210
PH: 913.369.7200
CERTIFICATE OF AUTHORITY:
MO #2014031351
(ENGINEERING)
INTERIM SUBMITTAL
NOT FOR
CONSTRUCTION PURPOSES
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM 08-6231
Veterans
Health
Administration
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
BID DOCUMENTS
Drawing Number
Project Number
Date
-OF-
Project Title
Building Number
Location
Checked Drawn
Approved: Project Director
Drawing Title
No.
VASTLHCS DEMOLISH
SEXTRO WAREHOUSE
JOHN COCHRAN DIVISION
657-CSI-603JC
Dwg.
CONSULTANTS: PRIME CONSULTANT:
ARCHITECT:
Date Revisions
CIVIL ENGINEER: LAND SURVEYING:
ST. LOUIS, MO
SETH CAVIN A.I.A.
MO# 2002021688 (ARCH)
04/25/2018
ELECTRICAL ENGINEER:
LEVEL 1A DEMOLITION PLAN
JEH JEH
30-AD-002
43 54
N
1/16" = 1'-0"
LEVEL 1A DEMOLITION PLAN
1/64" = 1'-0"
KEY PLAN 1A
1/64" = 1'-0"
SOUTH KEY ELEVATION 1A
UP
UP
UP
UP
H
G
F
E
D
C
B
A
1819202122
J
K
I
23242526272829303132
T
S
R
Q
P
O
N
M
L
V
30-AD-004
30-AD-004
EXISTING COAL CHUTE
FURNACE
585' - 4 1/2"
63' - 5"
42' - 4 1/2" 101' - 6" 74' - 6" 260' - 9" 106' - 3"
TYP.
TYP.
M A
T C
H L
IN
E
LOADING
DOCK
LOADING
DOCK
LOADING
DOCK
LOADING
DOCK
H
G
F
E
D
C
B
A
1234567891011121314151819202122
J
K
I
23242526272829303132
T
S
R
Q
P
O
N
M
L
161734
V
12345678910111213141518192021222324252627282930313233 16173435
1. DRAWINGS TO BE TAKEN AS PART OF A COMPLETE DOCUMENT
SET. CONTRACTOR TO CONFIRM ALL ITEMS REQUIRED TO BE
DEMOLISHED AND EXTENT OF DEMOLITION BASED UPON THE
OVERALL INTENT OF THE ENTIRE DOCUMENT SET.
2. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGININNG ANY
DEMOLITION WORK TO CONFIRM ACCURACY IN THE DRAWINGS.
REPORT ANY DISCREPANCIES TO CONTRACTING OFFICER.
DO NOT SCALE THE DRAWINGS. ALL DIMENSIONS SHOWN ON
DEMOLITION PLANS ARE APPROXIMATEFIELD VERIFY ALL
DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS
PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS
AT ALL TIMES. ERECT BARRICADES AND WARNING SIGNS TO
DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION
WORK.
4. DURING DEMOLITION, PROVIDE PROTECTION FOR ALL EXISTING
STRUCTURES AND IMPROVEMENTS TO REMAIN IN PLACE DURING THE
RENOVATION WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FACILITIES TO MATCH EXISTING.
ALL DEBRIS CREATED BY DEMOLITION SHOULD BE CONTAINED TO THE
PROJECT SITE.
5. ANY DAMAGE CAUSED TO THE SURROUNDING BUILDINGS AND
PROPERTY OR OWNER EQUIPMENT SHALL BE REPAIRED OR
REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL
COST TO THE OWNER.
6. ALL ITEMS WITHIN THE BUILDING ENVELOPE SHALL BE REMOVED
IN THEIR ENTIRETY INCLUDING RELATED COMPONENTS.
7. CONTRACTOR TO DEMO ALL FIXTURES, CEILINGS, MECHANICAL,
PLUMBING, ELECTRICAL COMMUNICATIONS, FIRE PROTECTION AND
FIRE ALARM SYSTEMS AS REQUIRED TO COMPLETE THE SCOPE OF
WORK OUTLINED WITHIN THE CONSTRUCTION DOCUMENTS.
8. DISCONNECT ALL UTILITIES AND ELECTRICAL POWER PRIOR TO
DEMOLITION. REF. CIVIL / MEP
GENERAL DEMOLITION NOTES
1. REMOVE EXISTING BRICK AND CMU WALLS, CONCRETE FLOOR SLAB, FOOTINGS, AND
ROOF.
2. REMOVE EXISTING WINDOWS, DOORS, AND OTHER OPENINGS THROUGHOUT.
3. REMOVE EXISTING STACK, FURNACE, AND COAL CHUTE.
KEYED NOTES - DEMOLITION
SPUR DESIGN
320 NW 10TH ST., SUITE A
OKLAHOMA CITY, OK 73103
PHONE: 405.842.6100
CERTIFICATE OF AUTHORITY:
MO #2012034754(ARCHITECTURE)
OATES ASSOCIATES
100 LANTER COURT, SUITE
COLLINSVILLE, IL 62234
PHONE: 618.345.2200
CERTIFICATE OF
AUTHORITY:
MO #001166 (ENGINEERING)
GLASPER PROFESSIONAL SERVICES,
INC.
13100 MANCHESTER RD., SUITE 85
ST. LOUIS, MO 63131
PH: 314.966.9987
CERTIFICATE OF AUTHORITY:
MO #2011027103 (LAND SURVEYING)
SPUR DESIGN
11020 KING ST., SUITE 350
OVERLAND PARK, KS 66210
PH: 913.369.7200
CERTIFICATE OF AUTHORITY:
MO #2014031351
(ENGINEERING)
INTERIM SUBMITTAL
NOT FOR
CONSTRUCTION PURPOSES
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM 08-6231
Veterans
Health
Administration
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
BID DOCUMENTS
Drawing Number
Project Number
Date
-OF-
Project Title
Building Number
Location
Checked Drawn
Approved: Project Director
Drawing Title
No.
VASTLHCS DEMOLISH
SEXTRO WAREHOUSE
JOHN COCHRAN DIVISION
657-CSI-603JC
Dwg.
CONSULTANTS: PRIME CONSULTANT:
ARCHITECT:
Date Revisions
CIVIL ENGINEER: LAND SURVEYING:
ST. LOUIS, MO
SETH CAVIN A.I.A.
MO# 2002021688 (ARCH)
04/25/2018
ELECTRICAL ENGINEER:
LEVEL 1B DEMOLITION PLAN
JEH JEH
30-AD-003
44 54
N
1/16" = 1'-0"
LEVEL 1B DEMOLITION PLAN
1/64" = 1'-0"
DEMOLITION KEY PLAN 1B
1/64" = 1'-0"
SOUTH KEY ELEVATION 1B
LEVEL 1A
100' - 0"
12345678910111213141518192021222324252627282930313233 1617
LEVEL 1B
88' - 0"
30-AD-004
LEVEL 1A
100' - 0"
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 3316 17
LEVEL 1B
88' - 0"
34 35
1. DRAWINGS TO BE TAKEN AS PART OF A COMPLETE DOCUMENT
SET. CONTRACTOR TO CONFIRM ALL ITEMS REQUIRED TO BE
DEMOLISHED AND EXTENT OF DEMOLITION BASED UPON THE
OVERALL INTENT OF THE ENTIRE DOCUMENT SET.
2. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGININNG ANY
DEMOLITION WORK TO CONFIRM ACCURACY IN THE DRAWINGS.
REPORT ANY DISCREPANCIES TO CONTRACTING OFFICER.
DO NOT SCALE THE DRAWINGS. ALL DIMENSIONS SHOWN ON
DEMOLITION PLANS ARE APPROXIMATEFIELD VERIFY ALL
DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS
PROJECT SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS
AT ALL TIMES. ERECT BARRICADES AND WARNING SIGNS TO
DIVERT AND WARN PASSERS-BY OF THE CONSTRUCTION
WORK.
4. DURING DEMOLITION, PROVIDE PROTECTION FOR ALL EXISTING
STRUCTURES AND IMPROVEMENTS TO REMAIN IN PLACE DURING THE
RENOVATION WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FACILITIES TO MATCH EXISTING.
ALL DEBRIS CREATED BY DEMOLITION SHOULD BE CONTAINED TO THE
PROJECT SITE.
5. ANY DAMAGE CAUSED TO THE SURROUNDING BUILDINGS AND
PROPERTY OR OWNER EQUIPMENT SHALL BE REPAIRED OR
REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL
COST TO THE OWNER.
6. ALL ITEMS WITHIN THE BUILDING ENVELOPE SHALL BE REMOVED
IN THEIR ENTIRETY INCLUDING RELATED COMPONENTS.
7. CONTRACTOR TO DEMO ALL FIXTURES, CEILINGS, MECHANICAL,
PLUMBING, ELECTRICAL COMMUNICATIONS, FIRE PROTECTION AND
FIRE ALARM SYSTEMS AS REQUIRED TO COMPLETE THE SCOPE OF
WORK OUTLINED WITHIN THE CONSTRUCTION DOCUMENTS.
8. DISCONNECT ALL UTILITIES AND ELECTRICAL POWER PRIOR TO
DEMOLITION. REF. CIVIL / MEP
GENERAL DEMOLITION NOTES
1. REMOVE EXISTING BRICK AND CMU WALLS, CONCRETE FLOOR SLAB, FOOTINGS, AND
ROOF.
2. REMOVE EXISTING WINDOWS, DOORS, AND OTHER OPENINGS THROUGHOUT.
3. REMOVE EXISTING STACK, FURNACE, AND COAL CHUTE.
KEYED NOTES - DEMOLITION
LEVEL 1A
100' - 0"
LEVEL 1B
88' - 0"
F
IE
L D
V E
R
IF
Y
F
IE
L D
V E
R
IF
Y
SPUR DESIGN
320 NW 10TH ST., SUITE A
OKLAHOMA CITY, OK 73103
PHONE: 405.842.6100
CERTIFICATE OF AUTHORITY:
MO #2012034754(ARCHITECTURE)
OATES ASSOCIATES
100 LANTER COURT, SUITE
COLLINSVILLE, IL 62234
PHONE: 618.345.2200
CERTIFICATE OF
AUTHORITY:
MO #001166 (ENGINEERING)
GLASPER PROFESSIONAL SERVICES,
INC.
13100 MANCHESTER RD., SUITE 85
ST. LOUIS, MO 63131
PH: 314.966.9987
CERTIFICATE OF AUTHORITY:
MO #2011027103 (LAND SURVEYING)
SPUR DESIGN
11020 KING ST., SUITE 350
OVERLAND PARK, KS 66210
PH: 913.369.7200
CERTIFICATE OF AUTHORITY:
MO #2014031351
(ENGINEERING)
INTERIM SUBMITTAL
NOT FOR
CONSTRUCTION PURPOSES
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
VA FORM 08-6231
Veterans
Health
Administration
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
BID DOCUMENTS
Drawing Number
Project Number
Date
-OF-
Project Title
Building Number
Location
Checked Drawn
Approved: Project Director
Drawing Title
No.
VASTLHCS DEMOLISH
SEXTRO WAREHOUSE
JOHN COCHRAN DIVISION
657-CSI-603JC
Dwg.
CONSULTANTS: PRIME CONSULTANT:
ARCHITECT:
Date Revisions
CIVIL ENGINEER: LAND SURVEYING:
ST. LOUIS, MO
SETH CAVIN A.I.A.
MO# 2002021688 (ARCH)
04/25/2018
ELECTRICAL ENGINEER:
DEMO ELEVATIONS
JEH JEH
30-AD-004
45 54
1" = 30'-0"
SOUTH ELEVATION
1" = 30'-0"
NORTH ELEVATION
1/8" = 1'-0"
SOUTH ELEVATION - SMOKESTACK
| _01_65~1 |
| _02_65~1 |
| 1 HA-01 |
| Sheets and Views |
| 1 HA-01 |
| PLOT |
| 2 HA-02 |
| Sheets and Views |
| 2 HA-02 |
| 3 HA-03 |
| Sheets and Views |
| 3 HA-03 |
| PLOT |
| 4 HA-04 |
| Sheets and Views |
| 4 HA-04 |
| 5 HA-05 |
| Sheets and Views |
| 5 HA-05 |
| 6 HA-06 |
| Sheets and Views |
| 6 HA-06 |
| PLOT |
| 7 HA-07 |
| Sheets and Views |
| 7 HA-07 |
| 8 HA-08 |
| Sheets and Views |
| 8 HA-08 |
| PLOT |
| 9 HA-09 |
| Sheets and Views |
| 9 HA-09 |
| _03_65~1 |
| 12_657-CSI-603JC C0.1 |
| 13_657-CSI-603JC C0.2 |
| 14_657-CSI-603JC C1.1 |
| 15_657-CSI-603JC C2.1 |
| 16_657-CSI-603JC C3.1 |
| 17_657-CSI-603JC C3.1A |
| 18_657-CSI-603JC C3.2 |
| 19_657-CSI-603JC C3.3 |
| 20_657-CSI-603JC C3.4 |
| 21_657-CSI-603JC C3.5 |
| 22_657-CSI-603JC C3.6 |
| 23_657-CSI-603JC C3.7 |
| 24_657-CSI-603JC C3.8 |
| 25_657-CSI-603JC C4.1 |
| 26_657-CSI-603JC C4.2 |
| 27_657-CSI-603JC C4.3 |
| 28_657-CSI-603JC C4.4 |
| 29_657-CSI-603JC C5.1 |
| 30_657-CSI-603JC C5.2 |
| 31_657-CSI-603JC C5.3 |
| 32_657-CSI-603JC C6.1 |
| 33_657-CSI-603JC C7.1 |
| 34_657-CSI-603JC C8.1 |
| 35_657-CSI-603JC C8.2 |
| _04_65~1 |
| 36_657-CSI-603JC SD0.1 |
| 37_657-CSI-603JC SD1.1 |
| 38_657-CSI-603JC SD1.2 |
| 39_657-CSI-603JC SD1.3 |
| 40_657-CSI-603JC SD1.4 |
| 41_657-CSI-603JC SD1.5 |
| _05_65~1 |
| Sheets |
| 30-AD-001 - DEMOLITION SITE PLAN |
| 30-AD-002 - LEVEL 1A DEMOLITION PLAN |
| 30-AD-003 - LEVEL 1B DEMOLITION PLAN |
| 30-AD-004 - DEMO ELEVATIONS |
| _06_VA~1 |
| 46_30-ES000-Electrical Legend |
| 47_30-ED101-Electrical Site Demolition Plan |
| 48_30-ES101-Electrical Site Plan |
| 49_30-ES501-Electrical Details |
| 50_30-ES601-Electrical One-Line Diagram |
| _07_VA~1 |
| 51_30-TS000-Technology Legend |
| 52_30-TS101-Technology Site Plan |
| 53_30-TS501-Technology Details |
| 54_30-TS601-Technology Riser Diagrams |
File details come from the government source that posted it.