This is a Sources Sought Notice for market research purposes issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 12 (Jesse Brown VA Medical Center in Chicago, IL). The contracting office is located in Milwaukee, Wisconsin (53214-1476), and the solicitation number is 36C25227Q0100. The Government is conducting market research to determine interest and capability among Other Than Small Businesses, Small Businesses, VetCert-certified Veteran-Owned Small Businesses (VOSB), and Service-Disabled Veteran-Owned Small Businesses (SDVOSB) to supply a Power Assisted Lipoplasty Device (PAL-750) on a brand name or equal basis.
The requirement includes two line items: (1) two units of PAL-750 Power Assisted Lipoplasty Device in Blue, and (2) one PAL Synergy Kit for 7020 without cart. Key specifications include maximum frequency of 3,800 cycles per minute, speed range of 4,000-5,000 cycles per minute, standard liposuction cannula compatibility with five cannulas included, 2-liter fat collection bottle, AC 110V/220V power supply at 50-60Hz frequency, console weight of 1.2 kilograms, and ergonomic handpiece design for surgical liposuction and medical aesthetic fat removal applications in hospital and clinic settings. Interested vendors must submit email responses to Patrick Trzeciak (patrick.trzeciak@va.gov, 830-500-1133) by November 20, 2026, at 3:00 p.m. Central Time, delineating qualifications, capabilities, experience, business size/socioeconomic status, manufacture location, product availability (Federal Supply Schedule or open market), and distributor authorization documentation if applicable. This notice is strictly for market research and does not constitute a solicitation or Government commitment. VOSBs and SDVOSBs must be VetCert-registered and verified for set-aside consideration.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| Power Assisted Lipoplasty Device and the Synergy KIT |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 53214-1476 |
| SOLICITATION NUMBER* |
| 36C25227Q0100 |
| RESPONSE DATE/TIME/ZONE |
| 11-20-2026 3:00 PM CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339112 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
36C252 115 South 84th Street, Suite 101
Milwaukee WI 53214-1476
POINT OF CONTACT*
Patrick Trzeciak patrick.trzeciak@va.gov 830-500-1133
PLACE OF PERFORMANCE
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of Other than Small Businesses and Small Businesses, including VetCert-certified Veteran-Owned Small Business (VOSB) or Service-Disabled Veteran-Owned Small Business (SDVOSB).
The Jesse Brown VA Medical Center in Chicago, IL has the requirement for a brand name or equal PAL-750, Power Assisted Lipoplasty Device and the Synergy KIT. The Government is requesting that Other Than Small Businesses and Small Businesses, including VetCert-certified VOSB or SDVOSB sources respond if it can meet the description below on a brand name or equal basis (PAL-750, Power Assisted Lipoplasty Device and the Synergy KIT):
| CLIN |
| Item |
| Description |
| Qty |
| Unit |
| 0001 |
| PAL-750 |
| Power Assisted Lipoplasty Device, Blue |
| 2 |
| EA |
| 0002 |
| SYNERGY-KIT |
| PAL SYNERGY KIT FOR 7020, NO CART |
| 1 |
| EA |
Salient Characteristics
- Max Frequency up to 3800 cycles/min
- Max Speed: 4,000 - 5,000 cycles/min
- Cannula Compatibility: Standard liposuction cannulas.
- Number of Cannulas: 5 suction cannulas included in standard config.
- Fat Collection: 2 L collection bottle.
- Power Supply - AC 110V/220V
- Frequency: 50-60HZ (standard medical equipment)
- Weight/Size:750 console weight - 1.2kg, handpiece 0.7kg.
- Vibration Stability: Stable frequency for smooth aspiration.
- Ergonomics: Hand piece design to reduce physical strain.
- Applications: Surgical liposuction, medical aesthetic fat removal, hospital/clinic use.
Interested Other Than Small Businesses and Small Businesses including VetCert-certified VOSBs and SDVOSBs are required to submit an e-mail delineating:
· Qualifications, capabilities, and experience for providing this product;
· Business size/Socioeconomic status;
· Manufacture location;
· If the product is on the Federal Supply Schedule or the Open Market; and
· Memo or correspondence which authorizes distributor to distribute the manufacturer’s products (if applicable).
This is not a Request for Proposal or an announcement of a solicitation and no solicitation currently exists. Your responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submissions will not be returned to the sender. VOSBs and SDVOSBs must be registered and verified in VetCert for set-aside consideration.
Responses are to be submitted by e-mail to Patrick Trzeciak at patrick.trzeciak@va.gov. The information requested must be received no later than 3:00 p.m. CDT on 11/20/2026.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .