36C25226Q0657.docx

DOCX document 26 KB Posted

Attached to
6525--IsoPoint System and Software Intent to Sole Source
Solicitation number
36C25226Q0657
Issued by

About this file

This is a Notice of Intent to Sole Source document issued by the Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office 12 in Milwaukee, Wisconsin. The VA intends to award a firm fixed price purchase on a sole source basis to AKTINA CORP., located at 360 N Route 9W, Congers, NY 10920-1420, for the acquisition of the isoPoint Isocenter Characterization System. This procurement supports the Clement J. Zablocki VA Medical Center's Stereotactic Radiosurgery (SRS) Program located in Milwaukee, Wisconsin.

The isoPoint system is a proprietary optical tracking and 3D mechanical isocenter analysis solution consisting of stereo camera pods, tracking modules, precision mechanical markers, and specialized software capable of 3D characterization, mechanical axis assessment, collimator and couch analysis, and beam-to-target error computation. The system will enhance quality assurance accuracy and efficiency for the facility's Elekta Versa HD LINAC by providing real-time 3D mechanical data with sub-0.01mm mechanical precision—capabilities not achievable through existing Winston Lutz methodologies. Aktina Medical is identified as the sole manufacturer and exclusive provider of this system, as it is the only known system capable of conducting direct mechanical rotational axis measurements of LINAC subsystems and generating a full 3D error matrix. Other quality assurance tools rely on image-based estimation and lack the ability to perform subsystem-specific mechanical characterization. This notice of intent is not a request for competitive proposals, no solicitation document is available, and no requests for quotes will be issued.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Special Notice Special Notice

SUBJECT*
IsoPoint System and Software Intent to Sole Source

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
53214-1476
SOLICITATION NUMBER*
36C25226Q0657
RESPONSE DATE/TIME/ZONE
08-18-2026 5:00pm EASTERN TIME, NEW YORK, USA
ARCHIVE
5 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
PRODUCT SERVICE CODE*
6525
NAICS CODE*
334517
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 12

115 South 84th Street, Suite 101 Milwaukee WI 53214-1476

POINT OF CONTACT*

Contracting Officer Stacy Massey Stacy.Massey@va.gov

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS
Stacy.Massey@va.gov
EMAIL DESCRIPTION
Procurement Point of Contact

DESCRIPTION

Intent to Sole Source The Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 12 in Milwaukee, WI, intends to award a firm‑fixed‑price purchase on a sole source basis to:

AKTINA CORP.

360 N ROUTE 9W

CONGERS, NY 10920-1420

This action is for the acquisition of the isoPoint™ Isocenter Characterization System. This procurement supports the Clement J. Zablocki VA Medical Center, Stereotactic Radiosurgery (SRS) Program, located at 5000 W. National Avenue, Milwaukee, WI 53295.

This notice of intent is not a request for competitive proposals. No solicitation document is available, and no request for quotes will be issued.

The Government requires the isoPoint™ Isocenter Characterization System, a proprietary optical tracking and 3D mechanical isocenter analysis solution used for precision quality assurance of stereotactic radiosurgery operations.

The system consists of:

· Stereo‑camera pod

· Tracking modules

· Precision mechanical markers

· Software capable of 3D characterization, mechanical axis assessment, collimator and couch analysis, and beam‑to‑target error computation The isoPoint™ system will enhance the accuracy and efficiency of quality assurance for the facility’s Elekta Versa HD LINAC, providing real‑time 3D mechanical data not achievable through existing Winston–Lutz methodologies. The system’s capability to achieve sub‑0.01 mm mechanical precision is critical to maintaining clinical standards for the SRS program.

Aktina Medical is the sole manufacturer and exclusive provider of the isoPoint™ Isocenter Characterization System. The isoPoint™ is the only known system capable of conducting direct mechanical rotational axis measurements of LINAC subsystems and generating a full 3D error matrix.

Other QA tools rely on image‑based estimation and lack the ability to perform subsystem‑specific mechanical characterization. Only Aktina Medical’s isoPoint™ system meets the clinical, technical, and operational requirements necessary to safely support the facility’s stereotactic radiosurgery program.

Interested parties may submit a capability statement that demonstrates the ability to provide an item equal to or exceeding the functional characteristics of the required isoPoint™ system. Responses must include:

· Technical specifications showing equivalency

· Proof of manufacturing authorization

· Evidence of ability to meet sub‑0.01 mm mechanical precision and full 3D mechanical axis characterization

· Delivery and installation capability Responses are due: August 18, 2026 at 5:00pm Email responses to: Stacy.Massey@va.gov Include: “Intent to Sole Source – isoPoint™” in the subject line.

No telephone inquiries will be accepted. If no responses meeting the Government’s requirements are received, the VA will proceed with the sole‑source procurement.

*= Required Field
Special Notice

Special Notice

File details come from the government source that posted it. Updated .