This is a Sources Sought Notice for market research purposes regarding the procurement of a Hobart flight-type dishwashing machine and related installation services at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin, operated by the Veterans Integrated Services Network (VISN) 12 under the Department of Veterans Affairs. The solicitation seeks authorized distributors of Original Equipment Manufacturers (OEM) equipment classified under NAICS code 335220 (Major Household Appliance Manufacturing) and Product Service Code 7320. The specific requirements include: one Hobart Model No. FT1000e Base flight-type dishwasher with automatic soil removal capability (Item 0001), installation of the FT1000e dishwashing machine (Item 0002), and installation of a Hobart WS80 water softener or equal (Item 0003).
To qualify as a small business seller, respondents must meet the requirements of 13 CFR 121.406 (b)(1)(i), (b)(1)(ii), and (b)(1)(iii). The Government explicitly states this Sources Sought Notice is for informational and planning purposes only and does not constitute a solicitation, obligation, or commitment. No compensation will be provided for responses, and information submitted will be used for market research purposes without public release. This notice represents preliminary market research; contractor participation does not guarantee future business opportunities.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice
| SUBJECT* |
| Dish Machine AP: 36C252-26-AP-2771 PR: 695-26-3-969-0241 |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 53214-1476 |
| SOLICITATION NUMBER* |
| 36C25226Q0591 |
| RESPONSE DATE/TIME/ZONE |
| 07-17-2026 10:00am CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 15 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 7320 |
| NAICS CODE* |
| 335220 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
36C252 115 South 84th Street, Suite 101 Milwaukee WI 53214-1476
POINT OF CONTACT*
Contracting Officer Rebecca Picchi rebecca.picchi@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Clement J. Zablocki VAMC |
5000 W. National Ave
Milwaukee, WI
| POSTAL CODE |
| 53295 |
DESCRIPTION
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government. This notice is intended strictly for market research. The purpose of this Sources Sought Notice is to obtain information from qualified sources with special interest relative to the North American Industry Classification Code (NAICS) 335220 Major Household Appliance Manufacturing.
The Government will not pay for information received in response to this Sources Sought, nor will the Government compensate any respondent for any cost incurred in developing the information provided. This Sources Sought does not constitute a commitment by the Government. Information provided in response to this market survey will be used for informational purposes only and will not be released. Contractor participation is not a promise of future business with the Government.
Requirement The VA Great Lakes Health Care System, Veterans Integrated Services Network (VISN) 12, Clement J. Zablocki VAMC in Milwaukee, WI is seeking authorized distributors to the Original Equipment Manufacturers (OEM) the equipment listed below. The VAMC is seeking businesses who are authorized distributors of the equipment under NAICS 335220 and Product Service Code (PSC) of 7320. In order to qualify as a small business seller your company must meet the requirements of 13 CFR 121.406 (b)(1)(i), (b)(1)(ii) and (b)(1)(iii).
| Items |
| Item Number |
| Description |
| Qty |
| 0001 |
| Hobart Model No. FT1000e Base or equal |
| Dishwasher Flight Type |
| 1 |
| 0002 |
| Hobart Flight Type Dishmachine or equal, Model No. FT1000e Installation |
| Installation |
| 1 |
| 0003 |
| Hobart WS80 Water Softener Installation or equal |
| Installation of Water Softener |
| 1 |
Details and Salient Characteristics:
1 ea Hobart Flight Type Dishmachine, Model No. FT1000e Base
· SEF-1011-01 Automatic Soil Removal- qty 1
· SEF-1011-03 Complete Delime- qty 1
· FT1000E-LPF25S 2.5’ Load Platform- qty 1
· FT1000E-DRYSYES with Dual Rinse- qty 1
· FT1000E-CTRSPL Split Center with 3’ Wash and 5’ Power Rinse joined with Dual Rinse
· FT1000E-UNL11S 11’ Unload Section Split Pack (5.5’) and (5.5’)- qty 1
· FT1000E-DRYYES Blower Dryer- qty 1
· FT1000E-HTESCL Steam Coil- qty 1
· FT1000E- CBRSHW SHW- with Circuit Breaker, Steam, High Voltage- qty 1
· FT1000E-BST120 120 Steam Booster- qty 1
· FT1000E-DRNUNL Drain in unload- qty 1
· WS80 Hobart Water Softening System- qty 1
· Additional 6-month warranty- qty 1 Salient characteristics:
· Steam-heat, standard/base model, compatible with or adaptable to existing electrical (480v/50/3 ph)
· Automatic deliming system with sensor to notify when delime required
· Digital control panel with visible cycle temperature display and machine diagnostics
· Sections for Loading, Automatic Soil Removal, Pre-Wash, Wash, Power Rinse, Dual Rinse, Blower Dryer, and Unloading
· Hinge Doors on all sections
· Wash cycle temperature ≥150°F
· Rinse cycle temperature ≥180°F
· NSF Certification
1 ea Hobart WS80 Water Softener Installation – Milwaukee, WI
· Install Water Softener on hot water line- qty 1
· Provide and install filter- qty 1
· Provide ≥ 1 bag of salt pellets- qty 1 Salient characteristics:
· Treat water to specifications required by Dishmachine (≤3 grains hardness)
1 ea Hobart Flight Type Dishmachine, Model No. FT1000e Installation – Milwaukee, WI
· Service Labor Hours for Base- qty 32 hrs
· Must include all required Electrical, Plumbing, Steam and HVAC work.
· Service Labor Hours for Center Split- qty 1 hr
· Service Labor Hours for Split Unloads- qty 1 hr
· Service Labor Hours for Blower Dryer- qty 4 hrs
It is the responsibility of the interested source to demonstrate to the government the interested party is an authorized distributor of the Original Equipment Manufacturer.
In addition to confirming status as an authorized distributor of the OEM you must include the following information:
1. Company name, address, point of contact, SAM.gov UEID and email address.
2. Size status and representation/s of the company (i.e., Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.). Any SDVOB or VOSB must be certified.
3. Is the company considered a small business under the NAICS code 335220?
4. If the company has a current federal contract, are the products being offered available on the contract?
5. Please include the country of manufacture and business size of the manufacturer.
6. Companies may propose more than one brand meeting the salient characteristics.
Questions should be sent to Rebecca Picchi at Rebecca.picchi@va.gov.
Responses to this source sought must be received no later than July 17, 2026 at 10:00am.
As a reminder, this is a Sources Sought announcement only. There is no guarantee, expressed or implicit, that the market research for this acquisition will result in a particular set-aside or sole source award, or any other guarantee of award strategy. All information is to be provided on a voluntary basis at no charge to the Government.
Interested vendors are reminded that in accordance with FAR 4.1102(a) Offerors and quoters are required to be registered in SAM at the time an offer or quotation is submitted in order to comply with the annual representations and certifications requirements. Registration is available at www.sam.gov.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .