36C25226Q0168.docx

DOCX document 28 KB Posted

Attached to
6515--578-26-2-969-0082 Prep and Pack Workstations (VA-26-00033788)
Solicitation number
36C25226Q0168
Issued by

About this file

This is a Sources Sought Notice issued by the Department of Veterans Affairs for the Hines VA Medical Center, seeking market research on potential vendors for 12 Coulmed Prep and Pack Workstations (AC1447). The solicitation targets Other than Small Businesses and Small Businesses, including Veteran-Owned Small Businesses (VOSB) and Service-Disabled Veteran-Owned Small Businesses (SDVOSB), under NAICS Code 339112.

The required workstations are highly specialized medical equipment with specific technical requirements, including 72"W x 36"D x 36"-44"H dimensions, stainless steel construction, electrically adjustable height, integrated LED lighting, anti-microbial work surfaces, and multiple storage and accessibility features. Vendors must submit responses by email to Vernise L. Newton by 10:00 am Central Standard Time on 01/15/2026. The workstations will be delivered to the Edward Hines VA Hospital Warehouse (Building 220) and used in Building 200, A025. This is a market research notice and not a formal solicitation, with responses used solely to assess vendor capabilities and interest.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
578-26-2-969-0082 Prep and Pack Workstations (VA-26-00033788)

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
53214-1476
SOLICITATION NUMBER*
36C25226Q0168
RESPONSE DATE/TIME/ZONE
01-15-2026 10:00 am CENTRAL TIME, CHICAGO, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

36C252 115 South 84th Street, Suite 101

Milwaukee WI 53214-1476

POINT OF CONTACT*

PLACE OF PERFORMANCE

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of Other than Small Businesses and/or Small Businesses, including VIP-Verified Veteran-Owned Small Business (VOSB) or Service-Disabled Veteran-Owned Small Business (SDVOSB) prospective contractors relative to the North American Industry Classification System (NAICS) Code 339112.

This sources sought notice is to determine interest and capability of authorized vendors able to fulfill the following requirement:

The Hines VA Medical Center is requesting the following: SPECIAL Pack and Prep WorkStations

Item 0001: PREP AND PACK WORKSTATION 72"W X 36"D X 36"-44'H -LED WORSURFACE LIGHT -FULLY WELDED STAINLESS STEEL CONSTRUCTION -MODULAR DESIGN ALLOWS FOR NULTIPLE CONFIGURATIONS -INTEGRATED FOOTREST -5" CASTERS (2 SWIVEL & 2 LOCKING) -EAH: ELECTRONICAL ADJUSTABLE HEIGHT -OLT: OVERHEAD LIGHT -LS: LOWER SHELF -2SH: ADJUSTABLE FLAT SHELF -DWR: DRAWER -MG: MAGNIFIER -MM: MONITOR MOUNT -KT: KEYBOARD TRAY -ES: ELECTRICAL STRIP -BR: BIN RAIL -3LSB: LARGE PLASTIC STORAGE BINS -2SSB: sMALL PLASTIC STORAGE BINS -RH: SPOOL HOLDER -PB: PEG BOARD

Dimensions: o Overall Length: 72 inches o Overall Depth: 36 inches o Overall Height: Adjustable from 36 inches to 44 inches to accommodate ergonomic needs Construction: o Constructed from high-grade, corrosion-resistant stainless steel for durability and easy cleaning o Heavy-duty frame providing stability and support for routine and extensive use Work Surface: o Anti-microbial work surface to ensure contamination control o Scratch-resistant and non-porous surface to prevent bacterial growth o Smooth, easy-to-clean surface with integrated fluid management features (e.g., drainage channels) o Light incorporated into the tabletop. Adjustability: o Electrically adjustable work surface height with smooth and quiet operation to support ergonomic working postures.

Memory preset function to allow quick adjustments to preferred heights o Tilt functionality for precise positioning and user comfort Integrated Lighting: o Built-in LED tabletop lighting providing uniform, shadow-free illumination of the work area o Adjustable brightness levels to suit different tasks and user preferences Storage and Accessibility: o Multiple storage options, including drawers and shelves, to keep essential tools and supplies organized and within reach o Removable and adjustable drawer dividers for customizable storage o Easy-glide drawers with smooth opening and closing mechanisms Power and Data Integration: o Built-in power outlets and USB ports for convenient charging and operation of electronic devices o Cable management solutions to keep the workspace tidy and free of clutter 9. Mobility: o Heavy-duty locking casters for easy mobility and secure positioning o Ergonomic handles for effortless movement and transport of the workstation Utilities: o Utility hooks and hangers for organized storage of commonly used tools Additional Features: o Compatibility with a wide range of accessories and add-ons, such as monitor arms, instrument racks, and task lights Compliance and Safety: o Meets applicable safety and performance standards, including [specific standards if applicable] o Designed to facilitate compliance with relevant infection control and sterilization protocols.

STATEMENT OF WORK

Coulmed Prep and Pack Workstation - AC1447

Background Due to the catastrophic event in SPS, the workstations in this area were deemed beyond repair. The Prep and Pack Workstations are critical in our ability to maintain essential sterilization processes critical for healthcare facility operations.

Selection Criteria The Prep and Pack Workstation AC1447 shall stand out with its robust construction, advanced ergonomic features, and comprehensive integration of lighting and storage solutions. Competitors offer similar features, the AC1447 shall provide a balanced combination of essential functionalities, making it a strong contender in the market.

Vendor must meet or exceed all requirements as specified below:

Specifications Dimensions:

Overall Length: 72 inches Overall Depth: 36 inches Overall Height: Adjustable from 36 inches to 44 inches to accommodate ergonomic needs

Work Surface Anti-microbial and scratch-resistant Non-porous for easy cleaning and contamination control

Adjustability:

Electrically adjustable height with memory presets Tilt functionality for ergonomic support Integrated Lighting:

Built-in LED lighting Adjustable brightness levels Place of Performance

· Equipment shall be delivered to the Edward Hines VA Hospital (Warehouse- Bldg. 220) @ 5000 5th Avenue, Hines, IL 60141.

· The 12 Coulmed Prep and Pack Workstations (AC1447) will be used in Building 200, A025.

· Qualifications, capabilities, and experience for providing this product;

· Business size/Socioeconomic status;

· Memo or correspondence from manufacturer to distribute their products.

This is not a Request for Proposal/Quote or an announcement of a solicitation and no solicitation package exists at this time. Responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submissions will not be returned to the sender. VOSBs and SDVOSBs must be registered and verified in VIP for set-aside consideration.

The applicable North American Industry Classification System (NAICS) Code for this requirement is 339112 responses should be submitted by e-mail to Vernise L. Newton at vernise.newton@va.gov. The information requested must be received no later than 10:00 am Central Standard Time on 01/15/2026.

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .