Presolicitation Notice Presolicitation Notice
| SUBJECT* |
| GREEN BAY VENTILATOR (Brand Name or Equal) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 53214-1476 |
| SOLICITATION NUMBER* |
| 36C25223Q0620 |
| RESPONSE DATE/TIME/ZONE |
| 06-15-2023 15:00 CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339112 |
| PLACE OF PERFORMANCE |
| Milo C. Huempfner Green Bay Health Care Center |
Green Bay VA Warehouse
2851 University Ave
Green Bay WI
| POSTAL CODE |
| 54311 |
| COUNTRY |
| USA |
CONTACT INFORMATION
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
GLAC (69D)
115 South 84th Street, Suite 101
Milwaukee WI 53214-1476
POINT OF CONTACT*
Contract Specialist Waymon McNeal waymon.mcnealjr@va.gov waymon.mcnealjr@va.gov
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
The VA Great Lakes Acquisition Center intends to solicit an open market unrestricted solicitation for Brand Name or Equal Hamilton MR1 Ventilator to the Milo C. Huempfner Green Bay Health Care Center Green Bay, WI 54311-5855.
ITEM INFORMATION-Brand Name
| ITEM NUMBER |
| DESCRIPTION OF SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1.00 |
| EA |
| _________ |
| _________ |
HAMILTON-MR1 Ventilator
PRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing PRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies
MANUFACTURER PART NUMBER (MPN): 1610100
| 1.00 |
| EA |
| _________ |
| ________ |
CLININCAL TRAINING
MANUFACTURER PART NUMBER (MPN): 59600
| 1.00 |
| EA |
| ________ |
| ________ |
HAMILTON-MR1 Service Training Tuition
LOCAL STOCK NUMBER: 59202MR1
| 1.00 |
| EA |
| ________ |
| ________ |
HAMILTON-MR1 Adult/Pediatric Configuraton
MANUFACTURER PART NUMBER (MPN): 10102162
| 1.00 |
| EA |
| ________ |
| ________ |
HAMILTON-MR1 US Power Cord
MANUFACTURER PART NUMBER (MPN): 355271
| 1.00 |
| EA |
| ________ |
| ________ |
HAMILTON-MR1 TROLLEY (WITH INTELLIBRAKE)
MANUFACTURER PART NUMBER (MPN): 161160
| 1.00 |
| EA |
| ________ |
| ________ |
DISS CONNECTOR 02-PLATFORM C
MANUFACTURER PART NUMBER (MPN): 160470
| 1.00 |
| EA |
| ________ |
| ________ |
HAMILTON MRI 02 CELL INITAL ORDER
MANUFACTURER PART NUMBER (MPN): 10103232
| 1.00 |
| EA |
| ________ |
| ________ |
HAMILTON-MRI LI-ION BATTERIES 2 PIECE
MANUFACTURER PART NUMBER (MPN): 10103230
| 1.00 |
| EA |
| ________ |
| ________ |
HAMILTON-MR1 English Language Kit
MANUFACTURER PART NUMBER (MPN): 10102404
| 1.00 |
| EA |
| ________ |
| ________ |
HAMILTON-MR1 USA Customization
MANUFACTURER PART NUMBER (MPN): 10102167
| 1.00 |
| EA |
| ________ |
| ________ |
HAMILTON-MR1 OPTION NIV/NIV-ST
MANUFACTURER PART NUMBER (MPN): 161073
ITEM INFORMATION- Equal Salient Characteristics Characteristics
Characteristics: Ventilator must meet the below minimum requirements
Technical and Functional Specifications
1. Device must be a comprehensive ICU ventilator for use in the MRI department.
2. Must be capable of withstanding a static magnetic field of up to 50 mT, allowing users to get close to the MRI scanner with the ventilator as needed.
3. Device must have an MR Conditional clearance of 1.5 and 3.0 Tesla static magnetic field.
4. Ventilator must be able to remain close to patient even during MRI scans.
5. Device must have a minimum battery life of 500 minutes.
6. Device must be portable, with the use of a roll stand.
7. Roll stand must have a locking system, preventing trolley from accidentally rolling towards the MRI scanner.
8. Ventilator must allow for volume-controlled and pressure-controlled ventilation modes.
9. Must have adaptive ventilation features with ASV.
10. Must have noninvasive ventilations modes
11. Must be capable of high slow nasal cannula therapy.
12. Ventilator must have an MR safety alarm system(gaussmeter), alarming users of safe distance measures to the MRI scanner.
13. Must include both visual and audible signal alarms.
This procurement is being conducted in accordance with FAR Part 12, 13, and 19. Contract will be firm fixed price and the corresponding NAICS Code 339112. This shall be open market unrestricted solicitation.
Please see Request for Quote (RFQ) document 36C25223Q0620 for details in the near future. This RFQ will be posted on or around Thursday, June 8, 2023. Offers will be due no later than 15:00. Local Time on Thursday, June 15, 2023.