36C25218B0839-0001000.docx
DOCX document 30 KB Posted
- Solicitation number
- 36C25218B0839
About this file
36C25218B0839 0001 36C25218B0839 0001.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25218B0839-008.docx | DOCX document | |
| 36C25218B0839-0002000.docx | DOCX document | |
| 36C25218B0839-0001001.pdf | ||
| 36C25218B0839-005.pdf | ||
| 36C25218B0839-003.docx | DOCX document | |
| 36C25218B0839-007.pdf | ||
| 36C25218B0839-004.pdf | ||
| 36C25218B0839-006.docx | DOCX document | |
| 36C25218B0839-002.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2.
AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE
OF PAGES
10A. MODIFICATION OF
CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV.
11/2016) is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO:
Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITE M 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES
SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR
43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes r eference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS
ENTERED INTO
PURSUANT TO AUTHORITY OF:
D. OTHER
BY
Contractor
16C. DATE SIGNED
14.
DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME
AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS
OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 06-12-2018 676-18-3-6985-0017 676-14-121B 36C252 Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) 115 S 84th Street, Suite 101 Milwaukee WI 53214-1476 36C252 Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) 115 S 84th Street, Suite Milwaukee WI 53214-1476 To all Offerors/Bidders
36C25218B0839 06-11-2018
X X X Monday June 18, 2018 at 11:00 a.m. CST
676-3680162-6985-854200-3220 23NRNR000
X
Amendment A00001 for Solicitation 36C25218R0839.
See page 2 andattachments for sepcific details. Bid opening has been extended to Monday, June 18, 2018 at 11:00 CST.
SOLICITATION 36C25218B0839
AMENDMENT 00001
06/12/2018
| PROJECT: | 676-14-121.B Correct Legionella B402 | |
| LOCATION: | Tomah VA Medical Center in Tomah, WI |
Amendment 00001 hereby incorporates the following change(s) into the solicitation package:
A.) VENDOR QUESTION, 06/01/2018:
1. A DMC50 is specified under Section 2.6 Master Mixing Station Sub-section 1. Also, a DRV50 is specified under Section 2.6 Master Mixing Station Sub-section 1.0. However, Salient Features part B under 2.6 Master Mixing Station sub-section 1.0 lists connections as 1 ½” and the flow as 41GPM @ 7.5ft/sec. This correlates to a DMC40, which uses a DRV40.
Please clarify if the desired Master Mixing Station is a DMC40 or DMC50 for this project?
VA REPLY: The DMC 40 is the proper Master Mixing Station.
B.) VENDOR QUESTIONS, 06/01/2018:
1. The continuous monitoring equipment specification states: “Sample water is circulated back into main water service.” The brand name specified does not have NSF 61 pH, ORP, and free chlorine sensors and therefore water that comes in contact with those sensors should not be circulated back into a potable water system in accordance with the Safe Drinking Water Act. The Phigenics© Potable Water Analytics (PWA) System (proposed brand name equivalent) includes a drain so that water that cannot be recirculated after sensor contact is drained from the system, ensuring full SDWA compliance. We recommend that you do not allow recirculation of water that comes in contact with sensors.
VA REPLY: Water circulated through/across an FCL senor shall be discharged at the nearest sanitary drain and not re-circulated back to the potable water system.
1. Temperature is not listed as salient parameter of the Water Quality Monitoring System, but it is required by Directive 1061. Should temperature also be monitored by the system?
VA REPLY: Temperature of the building incoming water supply shall be monitored see drawing G-3.1 detail 3 notes.
1. An ORP sensor and Free Chlorine (FCL) sensor are listed as salient features for the Water Quality Monitoring System. The ORP is not required by Directive 1061 and is redundant to a Free Chlorine sensor. The ORP unit of measurement is a “mV” value, which is not always meaningful for monitoring oxidant residuals. We recommend that ORP be removed from the list of salient features.
VA REPLY: The ORP sensor is a requirement of the directive (see VHA 1061 appendix A, section 2) but FCL is not; FCL has greater value. This project requires BOTH. This is easily achieved since the majority of COTS (commercial off the shelf) pH sensors have ORP capability.
1. There are different types of sensors that can measure chlorine, but only the DPD Colorimetric method is EPA-accepted. It is recommended that only a DPD colorimetric sensor is permitted for your continuous monitoring system VA REPLY: Noted.
1. One of the salient features of the Water Quality Monitoring System is that it has capability to integrate with BAS system. Are BACnet and/or Modbus acceptable means to transfer this data to the BAS?
VA REPLY: BACnet and/or Modbus is acceptable.
1. Phigenics brand WME-1175 Potable Water Analytics (PWA) Advanced Monitoring System 2.0 is specifically designed to meet the VHA Directive 1061 Continuous Monitoring requirements, uses EPA-accepted DPD colorimetric test method for measuring free chlorine, and is designed in full compliance with the SDWA. The total system is pre-wired and pre-plumbed on a rugged single skid to ensure high quality and a simple installation and requires only one tap from the main water line to provide a continuous sample stream of water to the monitoring system, one water drain for the sample line and is fully powered by a single 110V power supply. (See attached brochure for equipment information). Can you please confirm that you will accept the Phigenics Brand WME-1175 PWA Advanced Monitoring System as an approved equivalent for the continuous monitoring equipment?
VA REPLY: If the above noted system has recirculation capabilities to divert a portion of the sample water then yes, the system is acceptable. If this salient characteristic is not provided, the system is not acceptable.
Attached is a copy of the most current Wisconsin, Monroe County Wage Rates (WI11, WI180011, 05/25/2018). These wage rates replace previously issued wage rates.
If there are any open, un-answered questions a contractor has submitted, please send a follow-up e-mail to Kristi.Kluck3@va.gov.
The date for the public BID OPENING HAS BEEN EXTENDED. Bids are due no later than Monday, June 18, 2018 at 11:00 a.m. CST. The location for the public bid opening has not changed; bid opening is being held at the Honey Creek Business Park - 115 S. 84th Street - Suite 101, Milwaukee, WI 53214-1476.
LIST OF ATTACHMENTS:
See attached document: S06 A00001 Att1 DB Wage Rates 2018.05.25.
File details come from the government source that posted it.