About this file

36C25218B0839 36C25218B0839_1.docx

View the file

Other files

File Type Posted
36C25218B0839-001.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FedBizOpps Sources Sought Notice

CLASSIFICATION CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

RESPONSE DATE (MM-DD-YYYY)

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field FedBizOpps Sources Sought Notice Rev. March 2010 Z Project 676-14-121B Correct Legionella Deficiencies B402 at the Tomah VA Medical Center in Tomah, WI.

53214-1476 36C25218B0839 04-27-2018 N 238220 Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) 115 S 84th Street, Suite 101 Milwaukee WI 53214-1476 Kristi Kluck Kristi.Kluck3@va.gov Tomah VA Medical Center 500 E. Veterans Street Tomah, WI 54660

USA

THIS IS A SOURCES SOUGHT NOTICE ONLY

PROJECT:676-14.121B Correct Legionella Deficiencies
LOCATION:Tomah VA Medical Center
500 E. Veterans Street
Tomah, WI 54660

The purpose of this public notice is to collect information from small business interested in submitting a bid as the prime contractor for the work listed below associated with NAICS 238220 Plumbing, Heating and Air-Conditioning Contractors whereby the business is engaged in installing and servicing plumbing, heating and air-conditioning equipment.

Small Business Administration (SBA) NAICS 238220 size requirement is $15 million.

This project primarily involves furnishing, installing and programming a water quality monitoring system and a packaged hot water mixing station with the related temperature sensors, solenoid valves, DDC controllers, check valves and drain piping. Estimated period of performance is 210 calendar days. Estimated price range for construction is between $100,000 and $250,000. Reference Attachment 1.

Vendors strongly interested in this project as the prime contractor shall respond to this notice and provide the information listed below:

1. Company name, address, point of contact, phone number, DUNS number, and business status.

2. This business meets the following FAR and VAAR small business classifications:

___ Yes / ____No: IAW FAR 52.219-1, this company provides construction services assigned to NAICS 238220 and is a small business under the SBA Program.

___ Yes / ____No: IAW VAAR 852.219-10, this company provides construction services assigned to NAICS 238220 and is a qualified veteran-owned small business concern eligible under the VOSB CVE-VIP Program https://www.vip.vetbiz.gov/.

___ Yes / ____No: IAW VAAR 852.219-10, this company provides construction services assigned to NAICS 238220 and is a qualified service-disabled, veteran-owned small business concern eligible under the SDVOSB CVE-VIP Program https://www.vip.vetbiz.gov/.

___ Yes / ____No: IAW FAR 52.219-1, this company provides construction services assigned to NAICS 238220 and is a woman-owned small business concern eligible under the WOSB Program.

___ Yes / ____No: IAW FAR 52.219-1, this company provides construction services assigned to NAICS 238220 and is an economically disadvantaged woman-owned small business concern eligible under the EDWOSB Program.

___ Yes / ____No: IAW FAR 52.219-1, this company provides construction services assigned to NAICS 238220 and is a historically underutilized business under the HUBZone Small Business program.

___ Yes / ____No: IAW 13 U.S.C. 125.6(a)(4) the prime contractor’s limitations on subcontracting shall be no more than 75% of the amount paid by the government to the prime may be paid to firms that are not similarly situated. Any work that a similarly situated subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. Reference internet links provided in Note 1 below.

4. Provide documentation relating to the business capability of performance. Provide two (2) examples of projects like the above noted project regarding scope, complexity, and cost magnitude.

5. Provide details on how your company will comply with the 75% subcontracting limitations for the specialty plumbing trade.

Total response shall be no more than three (3) pages. Responses shall be submitted via email to Kristi.Kluck3@va.gov no later than 4:30 PM CST, April 27, 2018.

THIS IS NOT A REQUEST FOR PROPOSALS. It is a market research tool being utilized to determine the availability of potential qualified contractors before determining the method of acquisition. In addition, this Sources Sought is not to be construed as a commitment by the government, nor will the government pay for any information solicited or delivered.

NOTE 1:

· https://www.gpo.gov/fdsys/pkg/CFR-2012-title13-vol1/pdf/CFR-2012-title13-vol1-sec125-6.pdf

· https://www.ecfr.gov/cgi-bin/text-idx?SID=50ff66d5d1cc9357d5f4ce114fcc5c79&mc=true&node=pt13.1.125&rgn=div5#se13.1.125_16

Attachment(s) See attached document: P02 MR FBO Sources Sought_Att1 SOW 676.14.121B.

File details come from the government source that posted it.