36C25026Q0820.docx

DOCX document 29 KB Posted

Attached to
H946--Separate RO/DI Requirement Dayton - Services
Solicitation number
36C25026Q0820
Issued by

About this file

This is a Sources Sought Notice issued by the Department of Veterans Affairs Network Contracting Office for the Dayton Veterans Administration Medical Center. The solicitation number is 36C25026Q0820, with a response deadline of August 7, 2026 at 10:00 AM Eastern Time. The contracting office is located in Cincinnati, Ohio (zip code 45219), and the point of contact is Contracting Officer Ronald T. Heidemann (ronald.heidemann@va.gov, 513-559-3708). The product service code is H946 (Maintenance and Repair Services), and the NAICS code is 221310 (Water Supply and Irrigation Systems).

The requirement is to provide preventative maintenance services for reverse osmosis (RO) systems, water softeners, and hemodialysis equipment at the Dayton VAMC located at 4100 West Third Street, Dayton, Ohio 45248. Services include monthly preventative maintenance to RO/DI systems with quarterly and semiannual component changes (prefilter cartridges, carbon exchange tanks, DI tank exchanges, post-DI and UV filter cartridges), annual UV lamp and storage tank vent filter replacements, and chemical/ozone disinfection during non-operating hours. Water softener services include monthly inspection, water hardness testing, repairs as needed, and salt provision. Additionally, hemodialysis and laboratory purification equipment require monthly preventative maintenance service visits with deionized and carbon tank exchanges, filter replacements, and UV component provision. All work must comply with ANSI/AAMI ST108 standards and VHA Directive 1061. Work will be performed Monday through Friday, 8:00 AM to 4:30 PM, with the contract base period plus four option years beginning early October 2026. This Sources Sought notice requests information only from capable firms regarding their socio-economic status, existing contract vehicles, and any alternative NAICS codes; firms should not submit proposals at this stage.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Separate RO/DI Requirement Dayton - Services

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
45219
SOLICITATION NUMBER*
36C25026Q0820
RESPONSE DATE/TIME/ZONE
08-07-2026 10:00 AM EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
H946
NAICS CODE*
221310

CONTRACTING OFFICE ADDRESS

Department of Veterans Affairs Network Contracting Office (NCO) 10 260 E. University Avenue Cincinnati OH 45219

POINT OF CONTACT*

Contracting Officer Ronald T Heidemann ronald.heidemann@va.gov 513-559-3708

PLACE OF PERFORMANCE

ADDRESS
Dayton VA Medical Center

4100 West Third Street

Dayton Ohio

POSTAL CODE
45248
COUNTRY
United States

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.VA.gov
URL DESCRIPTION
Department of Veterans Affairs
AGENCY CONTACT’S EMAIL ADDRESS
ronald.heidemann@va.gov
EMAIL DESCRIPTION
Contracting Officer

DESCRIPTION

The Dayton Veterans Administration Medical Center (VAMC) has a requirement to provide preventative maintenance to all reverse osmosis systems and water softeners.

The intention of this Sources Sought is to obtain information only. Please do not send a proposal.

Requested information:

To aid acquisition planning, we’re seeking capable and interested firms for the information requested. If your firm meets the criteria and would like to take in the selection process please send the point of contract (ronald.heidemann@va.gov) the following, via email:

· Firm’s Name

· Socio-Economic Status

· Whether or not your company has a contract vehicle we can order against

· If your company believes there is an alternative NAICS code…please provide this

· If your company has any questions…please provide.

Contract Title. RO and Water Softener & Hemodialysis Services

Background: Contractor shall provide all parts, material, labor, and supervision, to provide services necessary to provide services within this statement of work.

Scope: Provide preventative maintenance to all reverse osmosis systems and water softeners. Must strictly adhere to latest versions of ANSI/AAMI ST108- Water for Processing Medical Devices and VHA Directive 1061 – Prevention of Health Care Associated Legionella Disease and Scald Injury from Water Systems.

Specific Tasks: Vendor will report to Robert Rhoad (COR) in the engineering department prior before and immediately after completion of services. Worker(s) will wear identification badges provided by VA when working on the VA campus or VA leased property. Keys may be picked up in B-128, room 133A. Keys are to be returned to B-128, room 133A at the end of each day. All service reports will be emailed to Robert.rhoad@va.gov

Reverse Osmosis (RO) and Water Softener Services

Sterile Processing System

· Provide monthly preventative maintenance service to RO/DI system.

· Change RO prefilter cartridge monthly.

· Provide carbon exchange tank semiannually.

· Provide DI tank exchange as needed (based on water usage) for (6) DI tanks.

· Change (5) post DI 5-micron filter cartridges quarterly.

· Change (5) post UV .2-micron filter cartridges quarterly.

· Change UV lamps annually.

· Change storage tank vent filter annually.

· Chemical disinfection of reverse osmosis system and ozone disinfect specific to the water system distribution loop monthly during non-operating hours.

· Reverse Osmosis System: SPS Evoqua Model # M41RSBVVOO3FND

Water Softener Services

· Provide monthly preventative maintenance service to (6) water softeners

· Inspect, test water hardness, note all data, and submit reports monthly. Perform repairs as needed. Recommend upgrades to equipment as needed.

· Provide salt for softeners (Steam Plant not included).

B330-2B100 RO System

· Provide monthly preventative maintenance service to RO system

· Inspect equipment, document equipment readings, supply a report on equipment to Include any recommended repairs.

· Change RO prefilter cartridge monthly.

· Annual Replacement of RO Membranes

Hemodialysis and Lab Purification Equipment Preventative Maintenance

· Monthly Preventative Maintenance Service visits where all operational conditions are all logged and evaluated.

· Provide six (6) Model DI-451447E, Ultra-pure mix-bed deionized exchange tanks. DI Exchange tanks are installed in a primary/secondary arrangement.

· Provide three (6) Model CA-111447E carbon tanks installed in a primary/secondary arrangement.

· Includes making minor adjustments on an “as needed basis” during the service to ensure proper operation of the system.

· Laboratory - Provide two (2) DI-451447E Ultra-pure mix-bed deionized exchange tanks. DI Exchange tanks are installed in a primary/secondary arrangement.

· Provide Model 20-5013 carbon block per-filter to be replaced each time deionizer tank is exchanged. Additional filters will be billed at current price.

· Provide two (2) Model 20-3046 endotoxin post filter and replace every six (6) months.

· Provide replacement UV components.

· Chemical disinfection of reverse osmosis system and ozone disinfect the water system distribution loop monthly during non-operating hours.

· Provide copies of any relevant license or certification.

· Models may be updated or changed in the duration of this contract.

Performance Monitoring: All work will be signed off by COR once completed.

Security Requirements: The C&A requirements do not apply, and a Security Accreditation Package is not required.

Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI). None

Other Pertinent Information or Special Considerations.

a. Identification of Possible Follow-on Work. N/A

b. Identification of Potential Conflicts of Interest (COI). None

c. Identification of Non-Disclosure Requirements. None

d. Packaging, Packing and Shipping Instructions. Any packing slips and shipping labels will include the PO#. If there are equipment/supplies a shipping confirmation should be provided to the COR and delivered to Dayton Veterans Affairs Medical Center 4100 W Third St Building 143, Dayton, OH 45428

e. Inspection and Acceptance Criteria: N/A

Place of Performance: VA Medical Center 4100 W. Third Street Dayton, Ohio 45428

Period of Performance: Base+4 FFP Beginning early October 2026.

Delivery Schedule: All work will be conducted during normal business hours, Monday – Friday, 0800-1630 except on federal holidays.

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .