36C25026Q0807.docx
DOCX document 27 KB Posted
- Attached to
- 6515--Equipment - Ultrasounds - Ann Arbor
- Solicitation number
- 36C25026Q0807
About this file
This is a Sources Sought Notice for ultrasound equipment and related medical devices required by the VA Ann Arbor Healthcare System. The Department of Veterans Affairs Veterans Integrated Service Network 10 is soliciting responses for PICC line placement vasculature positioning devices and accessories under NAICS code 339112 (Medical, Dental, and Surgical Instrument and Supplies Manufacturing). The Contracting Officer is Kellie Konopinski at the VA Network Contracting Office in Kettering, Ohio, with a response deadline of August 5, 2026, at 12:00 p.m. Eastern Time. Responses should be submitted to Kellie.Konopinski@va.gov referencing Acquisition ID 36C25026Q0807.
The specific items required include two units each of: SiteRite 9 Kickstand/Mounting Kit, SiteRite 9 Ultrasound System, SiteRite 9 Ultrasound System CUE Linear Probe, Sherlock 3CG Tip Confirmation Sensor, MER2 Rollstand, and Sony Medical Printer with mounting bracket. The equipment must provide an integrated monitor and ultrasound machine for vein assessment with high-resolution needle tip tracking, integrated software with remote control functionality contained within the ultrasound probe to maintain sterile field conditions, disposable individual ECG electrodes, a Sherlock T-piece tip tracker for chest placement, ECG technology for PICC tip confirmation in the Superior Vena Cava, needle tip tracking technology, and an ambidextrous remote-control design. Interested contractors must register with SAM.gov and include in their response their business information, SAM UEI, NAICS code, business size classification, veteran or small business status if applicable, product information with salient characteristics, country of manufacture, manufacturer details and authorized distributor letters if not the manufacturer, and confirmation of ability to provide all required items. Delivery is to the VA Ann Arbor Healthcare System at 2215 Fuller Road, Ann Arbor, Michigan 48105 on an FOB Destination basis.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| Equipment - Ultrasounds - Ann Arbor |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 45409-1337 |
| SOLICITATION NUMBER* |
| 36C25026Q0807 |
| RESPONSE DATE/TIME/ZONE |
| 08-05-2026 12:00pm EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 99 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339112 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 10 Suite 210 3140 Governors Place Blvd Kettering OH 45409-1337
POINT OF CONTACT*
Contracting Officer Kellie Konopinski Kellie.Konopinski@va.gov 734-222-4330
PLACE OF PERFORMANCE
| ADDRESS |
| VA Ann Arbor Healthcare System |
2215 Fuller Road
Ann Arbor MI
| POSTAL CODE |
| 48105 |
COUNTRY
DESCRIPTION
This is a SOURCES SOUGHT only pertaining to item(s) for the Ann Arbor VA healthcare facility. Information collected during this Sources Sought may be used in a set aside. If a solicitation is issued, the Government will do so in accordance with the Federal Acquisition Regulation (FAR) and applicable VA acquisition policies. The North American Industry Classification System (NAICS) number is 339112. The NAICS size is 1000 employees.
Any contractor that believes they are capable and desires to claim preference for small business status must be registered with the Small Business Administration (SBA) and be able to be located through the SBA Dynamic Small Business Search. Any contractor that believes that they are capable and desires to claim preference for veteran-owned small business status must be registered in SBA at SBA.gov as a Service-Disabled Veteran-Owned Small Business (SDVOSB) or Veteran-Owned Small Business (VOSB).
Contractors who deem themselves capable of meeting the requirement shall provide the information listed below to Kellie Konopinski, Contracting Officer at Kellie.Konopinski@va.gov no later than Wednesday, August 5, 2026, 12:00 p.m. EST., referencing Acquisition ID: 36C25026Q0807.
Responses shall include:
(1) Business Name and Address
(2) Contract number items are covered under, if applicable
(3) Point of Contact name, phone number, and email address
(4) SAM UEI and NAICS code
(5) Business size (Small or Large)
(6) Type of business (SDVOSB, VOSB, 8(a), HUBZone, Woman-Owned, etc.)
(7) Information about the product proposed and identification of any salient characteristics not met
(8) Country of manufacture
(9) If the concern is not the manufacturer, provide the manufacturer’s name, size standard, and an authorized distributor letter
(10) If the concern is the manufacturer and sole distributor, provide documentation to that effect; if the manufacturer has authorized distributors, provide a list of those distributors
(11) Contractor must confirm they can provide ALL required items.
Contractors must be registered with https://www.sam.gov.
To be considered SDVOSB/VOSB, contractors must be registered and certified in SBA.
FOB is destination.
Delivery is to:
VA Ann Arbor Healthcare System 2215 Fuller Rd.
Ann Arbor, MI 48105 Requirements: PICC Line placement vasculature positioning devices and accessories, brand name or equal to the following products:
| ITEM NUMBER |
| DESCRIPTION OF SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| 0001 |
| SITERITE 9 KICKSTAND/MOUNTING KIT |
LOCAL STOCK NUMBER: 9770806
| 2.00 |
| EA |
| 0002 |
| SITERITE 9 ULTRASOUND SYSTEM |
LOCAL STOCK NUMBER: 9770800
| 2.00 |
| EA |
| 0003 |
| SITERITE 9 ULTRASOUND SYSTEM CUE LINEAR PROBE |
LOCAL STOCK NUMBER: 9770803
| 2.00 |
| EA |
| 0004 |
| SHERLOCK 3CG TIP CONFIRMATION SENSOR |
LOCAL STOCK NUMBER: 9770358
| 2.00 |
| EA |
| 0005 |
| MER2 ROLLSTAND |
LOCAL STOCK NUMBER: BAR000360
| 2.00 |
| EA |
| 0006 |
| SONY MEDICAL PRINTER |
LOCAL STOCK NUMBER: UPX898MD
| 2.00 |
| EA |
| 0007 |
| SONY PRINTER BRACK |
LOCAL STOCK NUMBER: BAR000206
| 2.00 |
| EA |
Must meet the following requirements:
1. Integrated monitor and ultrasound machine (one machine for everything/vein access and PICC position) for vein assessment and access. Need a high clear resolution for needle tip tracking.
2. Integrated software program in the ultrasound machine that includes a remote control that has the software contained within the ultrasound probe itself. This helps ensure a sterile procedure field, with only one reach outside the field to grab the probe / remote. A separate remote requires a second reach and adds to expense with additional probe covers and replacements.
3. Disposable, individual ECG electrodes for each patient. (This reduces the potential for infectious pathogens to be spread from patient to patient, and room to room.)
4. A Sherlock T-piece tip tracker for the patient’s chest, to visualize PICC tip entry into the subclavian, and allow for repositioning before procedure ends if needed. (This is useful for Afib and paced patients, who can’t use ECG technology for PICC confirmation, but could still have a malpositioned PICC placement without this component)
5. ECG technology to confirm PICC Tip placement in the Superior Vena Cava all on one screen (No chest x-ray needed.)
6. Needle tip tracking technology to illuminate needle tip during vein cannulation and ensure pathway.
7. A true ambidextrous remote-control design.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .