36C25026Q0027 0001.docx
DOCX document 45 KB Posted
- Attached to
- H946--SPS Water Testing Indianapolis Federal contract opportunity
- Solicitation number
- 36C25026Q0027
About this file
This document is an Amendment to a Solicitation/Modification of Contract for water and steam testing services at the Richard L. Roudebush VA Medical Center in Indianapolis. The contract requires a contractor to perform comprehensive water quality testing in compliance with AAMI ST108 standards, including utility water, critical water, bacteria, endotoxin, and steam testing. Specific requirements include monthly and quarterly testing frequencies, with 6 utility water tests, 16 critical water chemistry tests, 296 bacteria tests, 296 endotoxin tests, and 6 steam conductivity tests per year.
The contract is structured with a base year and four option years, each running from November 15 to November 14, with multiple line items for different testing services. The contractor must provide all necessary labor, materials, and equipment, calibrate the government-owned resistivity meter, provide 260 pH hardness dipsticks annually, and deliver detailed written reports within 5 business days of each analysis. The testing will be performed in the Sterile Processing department, Reverse Osmosis mechanical room, and GI Decontamination processing areas, with the contractor responsible for training VA personnel on testing protocols and AAMI ST108 requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25026Q0027.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
36C25026Q0027 0001
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 583-26-1-669-0009 None Department of Veterans Affairs Network Contracting Office (NCO) 10 6100 Oak Tree Blvd., Suite 490 Independence OH 44131 Department of Veterans Affairs Network Contracting Office (NCO) 10 6100 Oak Tree Blvd., Suite 490 Independence OH 44131 To all Offerors/Bidders
36C25026Q0027 10-03-2025
X X X See CONTINUATION Page 583-3660162-669-854100-2543 010055590 X One (1) The purpose of this amendment to answer Contractor questions, update price/cost schedule, and update the Statement of Work (SOW).
The hour and date specified for receipt of offers remains unchanged.
Kristina L. Peart Contracting Officer
Contractor Questions and Answers
1. The solicitation states: “Lab shall be within one hour driving distance of VAMC to allow for emergency sample drop-off if needed by facility personnel.“ Is there any leeway in this requirement?
a. The lab utilized by the contractor shall have the ability to respond/process samples same day.
2. Could the government clarify how many samples will be collected by VA personnel versus how many will be the responsibility of the contractor?
a. The Contractor is responsible for all sample collection as VA staff shall not collect samples.
3. The solicitation notes: “Contractor shall provide training to SPS and Engineering personnel on AAMI ST108 requirements and responsibilities within one (1) week of contract award.” Could the government clarify the nature of this training? Specifically should the training be delivered virtually or on-site, and should it cover sampling protocols, interpretation of results, or other areas?
a. Training shall occur on-site during sampling. Training shall cover ongoing suggestions of sampling protocol, training on reading results, and training on any changes to the AAMI ST 108 standard.
4. The solicitation states: “Contractor shall provide pH hardness color metric dipsticks to the Richard L. Roudebush VAMC.” Can you confirm if these are the only supplies the contractor is required to furnish, and, if so, how many are expected annually?
a. Contractor shall provide 260 dipsticks annually, and vendor would be responsible for all collection supplies.
5. The solicitation states: “Contractor shall calibrate the government-owned resistivity meter monthly during their testing visit and provide a calibration certification.” Could the government clarify what type of certification is required in this context?
a. Calibration sticker and documentation on what standard or method was used to calibrate.
6. Could the government clarify which tests must be performed on-site and which should be completed at the laboratory?
a. Conductivity, PH and Resistivity could be performed on site during testing however all other tests must be resulted in a lab.
7. How many samples for bacteria and endotoxin will be taken each month?
a. 23 Endotoxin and 23 bacteria samples shall be taken each month.
8. The SOW lists Steam Conductivity as a testing parameter. Are we to test the Steam Conductivity or was it meant to state “Steam Condensate”?
a. The contractor shall test Steam Condensate Conductivity
9. What is the make and model number of the resistivity meter?
a. Myron Ultrameter 2
A.1 PRICE/COST SCHEDULE
ITEM INFORMATION
| ITEM NUMBER |
| DESCRIPTION OF SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 6.00 |
| EA |
| __________________ |
| __________________ |
Utility Water Chemistry Test Contract Period: Base POP Begin: 11-15-2025 POP End: 11-14-2026 PRINCIPAL NAICS CODE: 238220 - Plumbing, Heating, and Air-Conditioning Contractors PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 16.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Chemistry Test
POP Begin: 11-15-2025 POP End: 11-14-2026
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Bacteria Test
POP Begin: 11-15-2025 POP End: 11-14-2026
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Endotoxin Test
POP Begin: 11-15-2025 POP End: 11-14-2026
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 6.00 |
| EA |
| __________________ |
| __________________ |
Steam Water Chemistry Test
POP Begin: 11-15-2025 POP End: 11-14-2026
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 6.00 |
| EA |
| __________________ |
| __________________ |
Utility Water Chemistry Test Contract Period: Option 1 POP Begin: 11-15-2026 POP End: 11-14-2027
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 16.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Chemistry Test
POP Begin: 11-15-2026 POP End: 11-14-2027
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Bacteria Test
POP Begin: 11-15-2026 POP End: 11-14-2027
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Endotoxin Test
POP Begin: 11-15-2026 POP End: 11-14-2027
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 6.00 |
| EA |
| __________________ |
| __________________ |
Steam Water Chemistry Test
POP Begin: 11-15-2026 POP End: 11-14-2027
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 6.00 |
| EA |
| __________________ |
| __________________ |
Utility Water Chemistry Test Contract Period: Option 2 POP Begin: 11-15-2027 POP End: 11-14-2028
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 16.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Chemistry Test
POP Begin: 11-15-2027 POP End: 11-14-2028
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Bacteria Test
POP Begin: 11-15-2027 POP End: 11-14-2028
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Endotoxin Test
POP Begin: 11-15-2027 POP End: 11-14-2028
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 6.00 |
| EA |
| __________________ |
| __________________ |
Steam Water Chemistry Test
POP Begin: 11-15-2027 POP End: 11-14-2028
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 6.00 |
| EA |
| __________________ |
| __________________ |
Utility Water Chemistry Test Contract Period: Option 3 POP Begin: 11-15-2028 POP End: 11-14-2029
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 16.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Chemistry Test
POP Begin: 11-15-2028 POP End: 11-14-2029
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Bacteria Test
POP Begin: 11-15-2028 POP End: 11-14-2029
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Endotoxin Test
POP Begin: 11-15-2028 POP End: 11-14-2029
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 6.00 |
| EA |
| __________________ |
| __________________ |
Steam Water Chemistry Test
POP Begin: 11-15-2028 POP End: 11-14-2029
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 6.00 |
| EA |
| __________________ |
| __________________ |
Utility Water Chemistry Test Contract Period: Option 4 POP Begin: 11-15-2029 POP End: 11-14-2030
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 16.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Chemistry Test
POP Begin: 11-15-2029 POP End: 11-14-2030
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Bacteria Test
POP Begin: 11-15-2029 POP End: 11-14-2030
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 296.00 |
| EA |
| __________________ |
| __________________ |
Critical Water Endotoxin Test
POP Begin: 11-15-2029 POP End: 11-14-2030
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| 6.00 |
| EA |
| __________________ |
| __________________ |
Steam Water Chemistry Test
POP Begin: 11-15-2029 POP End: 11-14-2030
PRODUCT/SERVICE CODE: H946 - Other Quality Control, Testing, and Inspection - Water Purification and Sewage Treatment Equipment
| GRAND TOTAL |
| __________________ |
Base Year
Option Year One (1)
Option Year Two (2)
Option Year Three (3)
Option Year Four (4)
Aggregate Total (Base + Options, if exercised)
A.2 STATEMENT OF WORK
SOW Title: Sterile Processing Service (SPS) Water and Steam Testing Background: The medical center is required to complete testing on all water and steam systems utilize in the reprocessing of reusable medical devices. Water impurities can have adverse effects on medical devices and patient outcomes. The requirements of Association for the Advancement of Medical Instrumentation (AAMI) ST108: Water for the Processing of Medical Devices are intended to mitigate the risks associated with water identified to be in improper quality.
Scope: The Richard L Roudebush VA Medical Center, Indianapolis requires water quality testing to meet the criteria of AAMI ST108 for reprocessing of reusable medical equipment. This is located at the Richard L Roudebush VA Medical Center, located at 1481 W. 10th Street, Indianapolis, IN 46202. Services shall be in accordance with the terms, conditions, provisions and schedule of the contract.
Specific Tasks For Testing-Deliverable Product:
1. Contractor shall provide all labor, materials, equipment, transportation, lodging and supervision necessary to collect appropriate samples and deliver to a lab meeting requirement for processing of AAMI ST108.
2. Contractor shall provide training to SPS and Engineering personnel on AAMI ST108 requirements and responsibilities. This shall occur on an as needed basis when contractor is on-site for sampling and shall include ongoing suggestions for sampling protocol, training on reading results, and training on any new changes to the AAMI ST108 standard.
3. Contractor shall provide same tester each time to avoid the need of an escort. Escort shall be provided for first month of testing.
4. Tester shall be proficient in AAMI ST108 testing methods and procedures and documentation of training shall be provided.
5. Lab shall be within a close enough distance of VAMC to allow for emergency sample drop-off if needed by facility personnel and shall be able to process samples the same day.
6. Contractor shall provide pH hardness color metric dipsticks to the Richard L Roudebush VAMC – a quantity of 260 dipsticks annually.
7. Contractor shall calibrate the government owned resistivity meter monthly during their testing visit and provide a calibration certification with this visit as part of the report.
8. Contractor shall provide a detailed site-specific operation manual and training to the Richard L Roudebush VAMC SPS personnel and Engineering staff as well as training on use, results analysis, and mitigation of the tests performed.
Utility Water Testing
| Utility Water Quality Measurement |
| Utility Testing Frequency |
| Total Utility Tests Required for the year |
| AAMI ST108 Chemical Analysis (pH, Alkalinity, TOC, Aluminum, Conductivity, Hardness, Copper, Iron, Manganese, Nitrate, Phosphate, Sulfate, Silicate, Chloride & Zinc) |
| Quarterly/As Needed Retesting |
| 6 (including retests) |
Critical Water Testing
| Critical Water Quality Measurement |
| Critical Testing Frequency |
| Total Critical Tests Required for the year |
| AAMI ST108 Chemical Analysis (pH, Alkalinity, TOC, Aluminum, Conductivity, Hardness, Copper, Iron, Manganese, Nitrate, Phosphate, Sulfate, Silicate, Chloride & Zinc) |
| Monthly/As Needed Retesting |
| 16 (including retests) |
| Bacteria |
| Monthly/As Needed Retesting |
| 296 (including retests) |
| Endotoxin |
| Monthly/As Needed Retesting |
| 296 (including retests) |
Steam Testing
| Steam Quality Requirements |
| Steam Testing Frequency |
| Total Steam Tests Required for the year |
| Steam Conductivity |
| Quarterly/As Needed Retesting |
| 6 tests (includes 2 retests) |
Performance: The Government shall document performance. Any report shall become a part of the supporting documentation for any contractual action.
General Requirements
1. All on site work shall be coordinated with the Contracting Officer Representative (COR), at least seven (7) days prior to performance of services.
2. For testing services performed during normal work hours, 7:30 a.m. to 4:00 p.m. (Not including Federal holidays) at the Richard L Roudebush VA Medical Center, contractor’s tester shall report to Sterile Processing Services Administrative Officer, Building 1, RM A-B109, 317-955-9845.
3. Federal Holidays - The eleven holidays observed by the Federal Government are New Year’s Day, Birthday of Martin Luther King, Jr., Washington’s Birthday, Memorial Day, Juneteenth National Independence Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day. Also, any other day declared by the President of the United States to be a national holiday.
4. The contractor shall respond to routine communications within 48 hours.
5. The contractor shall provide emergency response, including a site visit if requested, within 4 hours of the request, 24 hours a day, and 365 days per year.
6. Situations requiring more frequent analysis and/or special testing other than the specified requirements may arise. Contractor shall not perform any extra cost work without written authorization from the contracting officer.
7. Any deficiencies or problems noted with VA test results or with the water treatment system test results are to be reported immediately to the COR. If problems are identified, the contractor shall recommend corrective actions immediately.
Deliverables
1. The contractor shall provide complete written reports within 5 business days after each analysis and inspection.
a. The reports shall include all test results, the date of the test, testing parameters, recommendations, and a review with the COR.
b. Each report shall highlight the results with a green for pass and red for fail, indicating whether the results pass or fail the parameters specified in AAMI ST108.
c. For any products utilized in the testing process, the following shall be documented on the report: name, ingredients, control range, test procedures, physical state (liquid, powder, etc.), container size, method of delivery, compatibility with present materials being used, catalog data, Material Safety Data Sheets (MSDS) sheets.
2. The reports shall be sent to the COR.
Security and Safety Requirements:
1. Contractor shall not have access to VA Sensitive Information, patient records, or data. The Contractor's employees shall wear visible identification and company uniforms approved by the COR at all times while on the premises of the VAMC.
2. It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police Section or from the COR. The VAMC will not invalidate or make reimbursement for parking violations of the Contractor under any conditions.
3. Smoking is prohibited inside any buildings at the VAMC.
4. Possession of weapons is prohibited.
5. Enclosed containers, including tool kits, shall be subject to search.
6. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court.
7. The Certification and Accreditation (C&A) requirements do not apply, and a Security Accreditation Package is not required.
8. Contractor personnel must follow all VA policies on personal protective equipment (PPE), cleanliness, and area restoration following maintenance.
Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI): The Richard L Roudebush VA Medical Center shall furnish a resistivity meter but will not furnish parts and/or any other test equipment for the performance of this contract. It is the responsibility of the contractor to bring the appropriate equipment; and/or supplies necessary to complete the work as required per this contract.
Other Pertinent Information or Special Considerations: All work shall be performed by personnel qualified to work on the specific equipment. All work performed shall be compliant with AAMI ST108 guidelines and shall be designed to assure that the Richard L Roudebush VA Medical Center is providing the best possible water to process reusable medical equipment.
Place of Performance: The Richard L Roudebush Department of Veterans Affairs Medical Center located at 1481 W. 10th Street, Indianapolis, IN 46202. AAMI ST108 testing shall take place in Sterile Processing department, Reverse Osmosis mechanical room, and GI Decontamination processing.
RLRVAMC SPS Water Testing
File details come from the government source that posted it. Updated .