This document is a Project Scope section describing a security system upgrade for a VA Medical Center. The project involves replacing an existing Saflok lodging electronic lock system by expanding the RS2 Technologies Access Control System (ACS), which includes installing 28 new proximity card readers and electric strikes on bedroom doors, replacing two existing proximity readers with HID Signo readers, and providing 200 HID Prox II proximity badges.
The document specifies that the VA Medical Center will provide supporting infrastructure like power requirements, network connectivity, servers, workstations, and wall space. The vendor will be responsible for system installation, programming, configuration, and testing. There is a preference for vendors within a 250-mile radius of Indianapolis, IN. For two specific doors (100 and 112), if a new cable cannot be installed, the existing cable will be reused with Open Supervised Device Protocol (OSDP) configuration instead of the Wiegand readers used for other doors.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25025R0077.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Scope
• Once the hardware installation has been completed, the vendor will provide programming and configuration support to test the system.
• If a new cable cannot be installed for Doors 100 and 112, then the existing cable will be reused, and the panels will be wired as Open Supervised Device Protocol
(OSDP) instead of the Wiegand readers configuration, which are one-way communication devices, that the rest of the doors will have.
Not Specified:
The following items provided and completed by VA Medical Center:
• Adequate power requirements (120V)
• Network Connectivity
• Required servers and workstations
• Fire alarm relay and interface as needed
• All servers and workstations that meet or exceed requirements
• Rack space, patch panels, and patch cables
• Required wall space for the mounting enclosure(s)
• Patching, painting, and repair of installation areas
• Adherence and compliance with local codes
Travel Time
Higher preference given to vendors within a 250 mile radius of the Indianapolis, IN