This Sources Sought Notice is issued by the LTC Charles S. Kettles VA Medical Center in Ann Arbor, Michigan, seeking qualified vendors to provide Pharmacy Biologic Safety Cabinet (BSC) Hood Replacement Services from September 15, 2025 to March 15, 2026. The project involves installing two Baker Sterigard Model SG404 biologic safety cabinets weighing 582 lbs each, which require unpacking, transportation to room DB21B, stand assembly, and initial certification in accordance with CETA CAG-003-2006 and United States Pharmacopeia (USP) Chapter 797 requirements.
Interested businesses are invited to submit responses by July 21, 2025 at 3:00 PM Eastern Time, with details including business name, contact information, SAM UEI, NAICS code (811210), business size, business type, and GSA/FSS contract number. The solicitation (36C25025Q0736) is seeking potential sources for the service, with the possibility of future set-asides. Respondents must have or employ personnel certified by CETA National Board Testing (CNBT) to perform the required equipment certification. The project is being conducted by the Department of Veterans Affairs Veterans Health Administration.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| Pharmacy BSC Hood Replacement LTC Charles S. Kettles VA Medical Center (Ann Arbor, MI) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 48105 |
| SOLICITATION NUMBER* |
| 36C25025Q0736 |
| RESPONSE DATE/TIME/ZONE |
| 07-21-2025 3:00pm EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| J065 |
| NAICS CODE* |
| 811210 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Ann Arbor Healthcare System Network Contracting Office 10 2215 Fuller Road Ann Arbor MI 48105
POINT OF CONTACT*
Contracting Officer Alexis S. Alexander Alexis.Alexander1@va.gov 734-222-7169
PLACE OF PERFORMANCE
| ADDRESS |
| LTC Charles S. Kettles VA Medical Center |
2215 Fuller Rd.
Ann Arbor MI
| POSTAL CODE |
| 48105 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/ann-arbor-health-care/ |
| URL DESCRIPTION |
| LTC Charles S. Kettles VA Medical Center |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Alexis.Alexander1@va.gov |
| EMAIL DESCRIPTION |
| Alexis S. Alexander |
DESCRIPTION
This Sources Sought/Market Survey Notice is being conducted by LTC Charles S. Kettles VA Medical Center, 2215 Fuller Rd., Ann Arbor, MI 48105 to identify all sources that are capable of providing Pharmacy BSC Hood Replacement Services for the period of September 15, 2025 – March 15, 2026, at the discretion of the Government in strict accordance with all schedules, specifications, terms, conditions and provisions of any resulting contract.
Pharmacy Sterile Compounding Hood Replacement and Certification
1. INTRODUCTION
Pharmacy Service is replacing sterile medication compounding equipment that has reached end of service life. Two (2) biologic safety cabinets (BSC) have been procured and require additional services to assemble/install and certify within Pharmacy cleanroom DB21B.
2. BACKGROUND
BSC’s are a type of primary engineering control (PEC) that create a near air particle free environment supportive of aseptic compounding of sterile medication products. These cabinets are often referred to as “hoods” and weight >500 lbs. New equipment is shipped on a pallet and requires transport to the location of installation. The unit must then be lifted and placed on a stand that requires assembly. Once installed initial certification must be conducted per regulatory requirements prior to use. Per VHA Directive 1108.12, equipment must be certified per Controlled Environment Testing Association (CETA) CAG-003-2006. Certification must be performed by a qualified contractor which is CETA National Board Testing (CNBT) registered or employs at least one employee with this credential.
3. SCOPE OF WORK
The Contractor shall:
a. Unpack and transport BSC cabinets from onsite storage location to final installation location of room DB21B.
b. Assemble cabinet stand with casters and place unit onto of stand per manufacturer instructions. Hardware and instructions provided by manufacturer. Set stand height per VA Pharmacy selection.
c. Perform initial certification of BSC equipment per CETA CAG-003-2006. Verify compliance with United States Pharmacopeia (USP) Chapter 797 requirements.
4. TECHNICAL REQUIREMENTS
Baker Sterigard Model SG404 biologic safety cabinet Cabinet weight: 582 lbs Exterior Dimensions: 53 ¾ x 30 11/16 x 61 ¾ inches (installed height on stand is 92 ¼ in)
If this is a service your business can provide, respond to this Sources Sought by Monday, July 21, 2025; 3:00 P.M. Eastern time. Responses should include: (1) Business Name and Address (2) Point of Contact Name, Phone Number, and E-mail Address (3) SAM UEI and NAICS code (4) Business Size SMALL or LARGE (5) Type of Business SERVICE DISABLED VETERAN OWNED, VETERAN OWNED, 8A, HUBZone, WOMEN-OWNED etc. (6) Applicable GSA/FSS Contract Number (if applies). All businesses eligible to provide this service are encouraged to reply as this information may be used to determine potential set-asides for the above noted service. E-mail responses to: Alexis Alexander, at Alexis.Alexander1@va.gov. (Note: This is NOT A REQUEST FOR QUOTE or an announcement of a solicitation.)