36C25021Q0171.docx

DOCX document 15 KB Posted

Attached to
4510-- Anti-Ligature Shower Wall Mount
Solicitation number
36C25021Q0171
Issued by

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Opportunity Sources Sought Notice

PRODUCT SERVICE CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

RESPONSE DATE/TIME/ZONE

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field Contract Opportunity Sources Sought Notice Anti-Ligature Shower Wall Mount 45409-1337 36C25021Q0171 12-18-2020

12:00PM

EASTERN TIME, NEW YORK, USA

N

SDVOSBC

332913 Department of Veterans Affairs Network Contracting Office 10 (NCO 10) Dayton VA Medical Center 3140 Governor’s Place Blvd. Suite 210 Kettering OH 45409-1337 Aleshia Hines-Best Aleshia.Hines-Best@va.gov Aleshia.Hines-Best@va.gov 937-262-2185 Northern Indiana Health Care System 1700 E 38th Street Marion

Indiana 46085 United States This Sources Sought/Market Survey Notice is being conducted by Network Contracting Office (NCO) 10, 3140 Governor’s Place Blvd Suite 210, Kettering, OH, 45409 to identify sources that can provide a Ligature-Resistant Surface Mounted Behavioral Wall Shower for the Northern Indiana Health Care System, 1700 East 38th Street, Marion, IN, 46953.

STATEMENT OF NEED

Ligature-Resistant Surface Mounted Behavioral Wall Shower

The NIHCS has a requirement for a brand name or equal for Ligature-Resistant Surface Mounted Behavioral Wall Shower (25). VA plumbers will install new devices in 185 1B acute psyche. Working within the directives required in house to install these units. Wall shower needs to have a ligature resistant temperature valve, ligature resistance push buttons, flow rate of 2.5 GPM, and a ligature resistant shower head.

If your business can provide the above required equipment and installation, please respond to this Sources Sought inquiry by Friday, December 18, 2020 at 12:00 P.M. EST.

Emails only accepted that reference subject:

RFI 36C25021Q0171 SOURCES SOUGHT – Ligature-Resistant Surface Mounted Behavioral Wall Shower

Responses should include:

(1) Business name, SEWP contract number (if applicable) and address

(2) Point of contact name, phone number, and E-mail address

(3) DUNS number and NAICS code

(4) Business size, i.e. SMALL or LARGE

(5) Type of business, i.e. Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), 8A, HUB Zone, Women Owned Small Business (WOSB), etc.

(6) Capability statement

All businesses capable of providing the required products and installation are encouraged to reply to this request for information as this may be used to determine potential set-asides for this request.

E-mail responses to:

Aleshia Hines-Best Aleshia.Hines-Best@va.gov

(Note: This is NOT A REQUEST FOR QUOTE or an announcement of a solicitation.)

File details come from the government source that posted it. Updated .