20600.54 DAYTON VA CHILLER FRAME_2020 09 10 PERMIT.pdf
PDF 344 KB Posted
- Solicitation number
- 36C25020B0076
About this file
This notice provides details for a federal construction contract opportunity to replace an air handler unit at the Dayton VA Medical Center. The Department of Veterans Affairs seeks to replace the pharmacy air handler unit and associated equipment through a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. Offerors must be verified in VIP, SAM, and Dun & Bradstreet databases. The contract value is estimated between $250,000 and $500,000 using NAICS code 236220 with a size standard of $39.5 million. The solicitation will require payment and performance bonds and include a site visit. The contractor must complete all work within 180 days of receiving the notice to proceed. Questions should be directed to the point of contact by the specified date, and amendments will be posted online.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25020B0076 0001.docx | DOCX document | |
| Replace Pharmacy AHU Drawings_Part1.pdf | ||
| Replace Pharmacy AHU Drawings_Part2.pdf | ||
| Replace Pharmacy AHU Drawings_Part3.pdf | ||
| 36C25020B0076_1.docx | DOCX document | |
| Statement of Work.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
D
3.1 3.1
C
X
C10X20
W8X10
C
X
C10X20
W8X10 W
X
W
X
W8X10W8X10
EX
EX
EXEX
EX
EX
E X
E X
E
XE
X
W X
W X
COORD w/UNIT SIZE
C X
C X
C X
C X
C10X20
C X
C10X20
S1
S1
O
PP H
AND
EXISTING STAIRS
S1O
PP H
AND
S1
S1
SIM
C10X20
C10X20
C10X20
UP
FIELD WELD 1/4" SHEAR TAB WITH
(2) 3/4"Ø THRU BOLTS
AT NEW WF TYP
GALVANIZED W-19-4 (1"x3/16") GRATING WITH
STAINLESS STEEL SADDLE CLIPS
G A
L V
A N
IZ
E
D W
-1 -4
(1
"x /1
G R
A T
IN
G
W
IT
H
S T
A
IN
L E
S S
S T
E E
L S
A D
D L
E C
L
IP
S
E Q
E Q
E Q
E Q
EQ EQ EQ
2'-0"
MODIFY EXISTING RAILING AS NEEDED
CUT AND PROVIDE NEW POST WHERE
THE EXISTING MEETS THE NEW
ATTACH RAILING SIMILAR TO
SECTION 2/S120
AT NEW BEAM PROVIDE 1/4" SHEAR TAB
WITH (2) 3/4"Ø THRU BOLTS
RAILING NOT SHOWN FOR CLARITY
L5x3x1/4 L5x3x1/4 L5x3x1/4
'-0
T
Y P
3'-0" 2'-0"
PROVIDE L5x3x1/4 LLV ANGLE
BOLTED TO EXISTING CHANNEL FOR GRATING BEARING
FIELD DRILL, (3) 3/4"Ø THRU BOLTS EVENLY SPACED
EACH ANGLE
OUTLINE OF PROPOSED RTU
REMOVE GRATNG AS NEEDED
VERIFY SIZE PRIOR TO FABRICATION
RAILING NOT SHOWN FOR CLARITY
2'-0" EXISTING C10x20
CHANNEL BEYOND
L3x3x1/4 CLIP ANGLE WITH
(2) 3/4"Ø THRU BOLTS
EACH SIDE
NEW C10x20
CHANNEL
NEW C10x20
CHANNEL
EXISTING BOLTS
COORDINATE HOLE
LOCATION AND BOLT
THRU NEW AND EXISTING
CHANNEL
BAR GRATING TO
MATCH EXISTING
6"
(2) NEW 3/4"Ø THRU
BOLTS AS SHOWN
FIELD DRILL
EXISTING CHANNEL
EXISTING 4"Ø POST
EXISTING C10x20
CHANNEL
* RAILING
NOT SHOWN
(2) NEW 3/4"Ø THRU
BOLTS AS SHOWN
FIELD DRILL
EXISTING CHANNEL
EXISTING
GRATING
3'-0"
2 1/2" EQUAL EQUAL
2'-0"
PIPE RAILING 1 1/2"Ø STANDARD PIPE
MATCH EXISTING HEIGHT AND SPACING
L5x3x1/4" LLV TOP
AND BOTTOM
SHOP WELD
3/8"x5"x0'-6" STEEL
PLATE WITH (2)
3/4"Ø THRU BOLTS
1/4 3"
TYP
EXISTING
GRATING
NEW BAR GRATING
MATCH EXISTING
C10x20 CHANNELL3x3x1/4 CLIP ANGLE
WITH (2) 3/4"Ø THRU
BOLTS EACH LEG
FIELD WELD
EXISTING C10x20 AS
NEEDED
EXISTING
C10x20 CHANNEL
C10x20 CHANNEL
T H
IS
D O C U M E N T A N D
T H E
ID
E A S
A N D
D E S
IG
N S
IN
C O R P O R A T E D
H E R E
IN
,A S
A N
IN
S T R U M E N T
O F
P R O F E S S
IO
N A L
S E R V
IC
E
IS
T H E
P R O P E R T Y
O F
A D V A N T A G E
G R O U P
E N G
IN
E E R S
IN
C
A N D
IS
N O T
T O
B E
U S E D
IN
W H O L E
O R
IN
P A R T F O R
A N Y
O T H E R
P R O J E C T ,W
IT
H O U T
T H E
W R
IT
T E N
A U T H O R
IZ
A T
IO
N
O F A D V A N T A G E
G R O U P
E N G
IN
E E R S
IN
C
C O P Y R
IG
H T
A D V A N T A G E
G R O U P
E N G
IN
E E R S
IN
C A L L
R
IG
H T
R E S E R V E D
Design Team:
Date:
Proj. No.:
Drawing No.
Seal:
D R
A W
IN
G
T
IT
LE
St ru ct u ra l C o n su lt an ts
EN
G
IN
EE
R S, IN
C
A D
V A
N T A
G E
G R
O U
P
M ad is o n R o ad
C in ci n n at i, O h io
P h
-8
S1
CCH / SJ
20600.54 R20
EX
IS
TI
N
G R
TU
F
R A
M E
EX
TE
N
SI
O N
PL
A
NPR
EP
A R
ED
F
O R
D
A
YT
O N
V A
D A
YT
O
N V
A R
TU
F
R A
M
IN
G
08/20/2020
V A
M C
D
A
YT
O N
, O H
IO
SCALE 1/2" = 1'-0"
EXISTING RTU FRAME EXTENSION PLAN
NORTH
PLAN NOTES:
1. CONTRACTOR TO VERIFY EXISTING CONDTIONS ON SITE PRIOR TO CONSTRUCTION.
EXISTING RTU FRAME SHOWN IS BASED ON THE STRUCTURAL DRAWINGS BY TOLAND &
MIZELL ARCHITECTS AND APPLIED ENGINEERING SOLUTIONS, INC. DATED JUNE 17, 2010.
2. THE PROPOSED NEW UNIT SHALL WEIGH NO MORE THAN 2500 lbs AND IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE BEARING LOCATIONS OF THE NEW
UNIT PRIOR TO INSTALLATION.
3. ALL NEW STEEL SHALL BE HOT DIPPED GALAVANIZED AND THEN TOUCHED UP AS NEEDED
IN THE FIELD AFTER INSTALLATION.
4. THE BAR GRATING SHALL MATCH THE EXISTING, 1” x 3/16” ATTACHED TO THE FRAMING WITH
¼” SADDLE CLIPS.
5. NO EXISTING BRACING SHALL BE REMOVED WITHOUT THE WRITTEN CONSENT OF THE
STRUCTURAL ENGINEER UNLESS SHOWN ON THE DRAWINGS.
6. ALL FIELD WELDS SHALL BE TOUCHED WITH GALVANIZING PER GENERAL NOTES.
7. REMOVE EXISTING GRATING AS NEEDED TO INSTALL NEW UNIT.
FRAMING 3D VIEW
SECTION
S1SCALE 3/4" = 1'-0"
SECTION
S1SCALE 3/4" = 1'-0"
GENERAL STRUCTURAL NOTES
COPIES OF PUBLICATIONS REFERENCED IN THESE GENERAL STRUCTURAL NOTES ARE
AVAILABLE FOR REVIEW AT ADVANTAGE GROUP ENGINEERS, INC. CONTRACTORS UNFAMILIAR
WITH THESE PUBLICATIONS MUST REVIEW THEM PRIOR TO CONSTRUCTION.
GOVERNING CODE
OHIO BUILDING CODE – 2017, BASED ON 2015 IBC
CLASSIFICATION OF BUILDING STRUCTURE
RISK CATEGO
DESIGN LOADS
1. EXISTING ROOF LOAD:
A. MINIMUM LIVE LOAD OR SNOW LOAD (Pf): 22 PSF
B. CONCRETE ROOF DECK: 34 PSF
C. STONE PAVERS: 10 PSF
D. COLATERAL DEAD LOAD: 15 PSF
2. SNOW LOAD:
A. GROUND SNOW LOAD, Pg = 20 PSF MODIFIED BY APPLICABLE DRIFT COEFFICIENTS.
B. FLAT ROOF SNOW LOAD, Pf = 17 PSF MODIFIED BY APPLICABLE BUILDING COEFFICIENTS.
C. SNOW LOAD IMPORTANCE FACTOR I = 1.00
D. SNOW EXPOSURE FACTOR Ce = 1.0
E. THERMAL FACTOR, Ct = 1.00
3. WIND LOAD:
A. MAIN WINDFORCE - RESISTING SYSTEM: 120 MPH PER ASCE 7-10 (3-SECOND GUST- LOAD
RESISTANCE FACTORED DESIGN).
B. WIND EXPOSURE C
C. BASIC WIND VELOCITY PRESSURE (COMPONENTS AND CLADDING), qh= 35 PSF.
D. INTERNAL GUST PRESSURE COEFFICIENT GCp = 0.18, ENCLOSED BUILDING.
4. SPECIAL LOADS:
A. HANDRAILS: 200 POUNDS CONCENTRATED LOAD AT ANY POINT IN ANY DIRECTION OR 50
PLF UNIFORM LOAD IN ANY DIRECTION.
B. PROPSOED UNIT WEIGHT = 3200 lbs
5. LIVE LOADS:
RTU FRAME WALKWAYS: 60 PSF
SUBSTITUTIONS, SUBMITTALS, AND RFI'S
1. CONTRACTOR SHALL SUBMIT ALL SUBSTITUTIONS FOR APPROVAL PRIOR TO
CONSTRUCTION WITH THE FOLLOWING INFORMATION:
2. SHOP DRAWING SUBMITTALS SHALL BE SUBMITTED BY THE GENERAL CONTRACTOR IN A
TIMELY MANNER TO PROVIDE AN ADEQUATE AMOUNT OF TIME FOR REVIEW.
A. REVIEW BY STRUCTURAL ENGINEER OF RECORD WILL BE FOR GENERAL COMPLIANCE
WITH THE CONTRACT DOCUMENTS AND CONFORMANCE WITH THE DESIGN CONCEPT.
THIS REVIEW DOES NOT IN ANYWAY RELIEVE THE CONTRACTOR AND/OR THE
CONTRACTOR'S SUBCONTRACTORS FROM RESPONSIBILITY FOR ERRORS OR DEVIATIONS
FROM THE CONTRACT REQUIREMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL
DIMENSIONS, PROPER FIT, QUALITIES OF THE MATERIALS, AND COORDINATION WITH
OTHER TRADES AND SUPPLIERS.
3. REQUESTS FOR INFORMATION (RFI'S) SHALL BE SUBMITTED IN A TIMELY MANNER WHEN
INFORMATION IS MISSING FROM THE CONSTRUCTION DOCUMENTS, INFORMATION IS
CONFLICTING WITHIN THE CONSTRUCTION DOCUMENTS, OR IS AMBIGUOUS.
A. THE CONTRACTOR MUST USE DUE DILIGENCE IN ATTEMPING TO FIND ANY ANSWER
PRIOR TO SUBMITTING AN RFI.
B. IF THE INFORMATION REQUESTED IN AN RFI IS APPARENT FROM FIELD OBSERVATION, IS
CONTAINED IN THE CONSTRUCTION DOCUMENTS, OR IS REASONABLY INFERABLE FROM THE
CONSTRUCTION DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE TO THE OWNER
FOR ALL REASONABLE COSTS CHARGED RELATED TO ADDITIONAL SERVICES INCURRED
DUE TO ANSWERING THE RFI.
CONSTRUCTION AND SAFETY
1. CONTRACTOR SHALL BRACE ENTIRE STRUCTURE AS REQUIRED TO MAINTAIN STABILITY
UNTIL COMPLETE AND FUNCTIONING AS THE DESIGNED UNIT.
2. ENGINEER SHALL NOT BE RESPONSIBLE FOR THE MEANS, METHODS, TECHNIQUES,
SEQUENCES OR PROCEDURES OF CONSTRUCTION SELECTED BY CONTRACTOR.
3. THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF
THE JOB SITE INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF
THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS. WHEN ON SITE, THE ENGINEER IS RESPONSIBLE FOR HIS OWN SAFETY BUT
HAS NO RESPONSIBILITY FOR THE SAFETY OF OTHER PERSONNEL OR SAFETY CONDITIONS AT
THE SITE.
STRUCTURAL STEEL
1. ALL DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO AISC SPECIFICATIONS
FOR "DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", AND
THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES", LATEST
EDITION.
2. NO OPENING OR HOLE SHALL BE PLACED IN ANY STRUCTURAL MEMBER (OTHER THAT WHAT
IS INDICATED ON THE DRAWINGS) UNLESS THE LOCATION HAS BEEN APPROVED IN WRITING BY
THE STRUCTURAL ENGINEER.
3. ALL FLOOR OR ROOF BEAMS SHALL BE FABRICATED WITH THE NATURAL CAMBER UP.
4. FIELD CONNECTIONS SHALL BE BOLTED EXCEPT WHERE WELDED CONNECTIONS ARE
INDICATED ON THE STRUCTURAL DRAWINGS.
5. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS D1.1).
6. MATERIALS:
A. ROLLED WIDE FLANGE SHAPES UNLESS NOTED: ASTM A992 DUAL GRADE, Fy = 50 ksi.
B. ROLLED SHAPES AND PLATES UNLESS NOTED: ASTM A-36.
C. TUBULAR SHAPES: ASTM A500, GRADE B.
D. PIPE SHAPES: ASTM A53, TYPES E OR S GRADE B.
E. BOLTS: ASTM A325-N, 3/4" DIAMETER UNLESS NOTED.
F. ANCHOR RODS: ASTM F1554 – GRADE 36 KSI MATERIAL FULLY THREADED RODS HAVING A
NUT TACK WELDED IN PLACE ON BOTTOM. MINIMUM EMBEDMENT AS NOTED ON THE
DRAWINGS.
G. FIELD WELDS: AWS E70XX, LOW HYDROGEN ELECTRODES.
7. PAINT AND PROTECTION:
A. MEMBERS EXPOSED TO WEATHER IN FINISHED STRUCTURES:HOT DIP GALVANIZE PER
ASTM A123 AFTER FABRICATION. COATING WEIGHT PER PARAGRAPH 5.1 OF ASTM A123
AND A153. FABRICATE ASSEMBLIES PER ASTM A143, A384, AND A385. TOUCH UP AFTER
ERECTION WITH ORGANIC ZINC RICH PAINT COMPLYING WITH DOP-P-21035 OR MIL-
P-26915, MULTIPLE COATS TO DRY FILM THICKNESS OF 8 MILS.
R
E V
IS
IO
N /S
U B
M I S
S
IO
N D a te
F O
R R
E V
IE
W
/C O
N S
T
/1
/ 2
| Sheets |
| S1 - EXISTING RTU FRAME EXTENSION PLAN |
File details come from the government source that posted it. Updated .