36C25020B0065.docx
DOCX document 22 KB Posted
- Solicitation number
- 36C25020B0065
About this file
This document provides details for a federal contract opportunity to upgrade the fire alarm system at the Louis Stokes Cleveland VA Medical Center. The project will be conducted in two phases, with the first involving installation of a new campus fiber loop and fire alarm control panels, and the second rewiring existing field devices and reprogramming them to correspond to the appropriate control panels. The project magnitude is between $2,000,000 and $5,000,000 and work must be completed within 425 calendar days of receiving the notice to proceed. Interested parties should register at SAM.gov by November 24, 2020 to receive solicitation documents and amendments. Questions are due by the specified cutoff prior to bid opening scheduled for approximately 30 days after solicitation posting. The contracting agency is the Department of Veterans Affairs Veterans Health Administration.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract Opportunity Presolicitation Notice
PRODUCT SERVICE CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE
DATE/TIME/ZONE
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
Required Field Contract Opportunity Presolicitation Notice
Z2BG
PROJECT 541-18-101: UPGRADE FIRE ALARM SYSTEM
(CONSTRUCTION) - LOUIS STOKES VA MEDICAL CENTER (VAMC) -
CLEVELAND, OH
**NOTE: UNRESTRICTED - FULL AND OPEN
COMPETITION
43219-1834 36C25020B0065 N 238210 Department of Veterans Affairs VA Healthcare System Network contracting Office (NCO) 10 2780 Airport Dr, Suite 340 Columbus OH 43219-1834 Contract Specialist Shelton Beasley shelton.beasley@va.gov
USE EMAIL ONLY
614-257-5829 Department of Veterans Affairs Veterans Health Administration Louis Stokes Cleveland VA Medical Center 10701 East Boulevard Cleveland OH 44106
USA
Project # 541-18-101: Upgrade Fire Alarm System. This is a multi-phased project at the Louis Stokes Veterans Affairs Medical Center (VAMC) located in Cleveland, OH. This multi-phased project that will upgrade the existing fire alarm system at the facility. Upon project completion, the VA will have addressed all deficiencies with the current fire alarm system. The upgraded system is designed to meet all NFPA codes and current guidelines.
Phase 1: The contractor will install the new campus fiber loop and all of the new Notifier® head end units. During this phase, all of the new head end equipment will be fully tested and ready for use prior to proceeding to phase two.
Phase 2: The contractor will trace out conduits and wiring of the existing field devices, i.e. strobe, horn/strobes, pull stations, smoke detectors, etc. and rewiring them as necessary so that they are reporting back to the head end unit contained within the appropriate smoke compartment/zone. This rewiring effort corrects that type of issue so that only the code required areas will be initiated. In addition to the rewiring of all of the devices, all of the devices will need to be re-programmed as well so that they report and are associated with the correct Notifier® control panel.
At project conclusion, each smoke compartment/zone will have its own Notifier® control panel and all of the devices associated to the panel will be contained within the smoke zone it is installed in.
All employees of general contractor and subcontractors shall comply with VA security management program and obtain permission of the VA police, be identified by project and employer, and restricted from unauthorized access.
SET-ASIDE INFORMATION: There is no set-aside for this solicitation. Large, medium and small businesses of all types are welcome to submit a bid. However, all bidders MUST be registered and verified in the following websites: https://beta.sam.gov, to be eligible for award. Bidders MUST ensure registration in this website is accurate, complete and have not expired prior to bid opening date. Project magnitude is between $2,000,000.00 and $5,000,000.00. The NAICS code is 238210. Duration of the project shall not exceed 425 calendar days from receipt of the Notice to Proceed (NTP).
BONDS in form of Bid, Payment and Performance will be required.
SITE VISIT: a one-time only site visit will be scheduled and that information will be in the solicitation package. The solicitation documents will be posted at https://beta.sam.gov on or about November 24, 2020, with bid opening approximately 30 days later. Dissemination of the solicitation, specifications and drawings is limited to electronic medium. All interested Bidders (primes & subcontractors) should register at https://beta.sam.gov so others will know of your interest in participating in this procurement and for automatic receipt of updates or amendments. A Bidder's mailing list WILL NOT be prepared nor distributed by the Contracting Officer, as it is the Bidders responsibility to register at the https://beta.sam.gov website.
SOLICITATION AMENDMENTS: Amendments to the solicitation will be posted at https://beta.sam.gov. Paper copies of the amendment will NOT be individually mailed. By registering to this opportunity, you will be notified by e-mail of any new amendments that have been issued and posted. No other notification amendment will be provided. Bidders are reminded that they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers as prescribed by FAR 52.214-3, Amendments to Invitation for Bids. Bidders should re-visit the Website periodically to look for updates. All requests for information are required to be in writing to the Contracting Officer and shall be received within the time specified in the solicitation documents; no telephone inquiries will be accepted. It is the interested bidders’ responsibility to be sure your questions were actually received in the contracting office for a response, prior to the cut off period. Questions received after the cut off period will not receive responses. Questions may be emailed to shelton.beasley@va.gov. with the heading – “Project # 541-18-101 Upgrade Fire Alarm System.” The Contracting Officer cannot guarantee that a response to e-mailed questions will be received.