Addendum No.1 Description.pdf

PDF 47 KB Posted

Attached to
Y1DZ--Expand MRI Suite Project 541-CSI-103
Solicitation number
36C25020B0043
Issued by

About this file

This addendum provides revisions to specifications and drawings for an expansion of the MRI suite at the Louis Stokes VA Medical Center in Cleveland, Ohio. Mechanical revisions include replacing the systems integration specification section and revising piping and clerical errors on drawings. Electrical revisions consist of adding panelboard schedules and clarifying UPS requirements on drawings, providing circuit breaker information and revising panel descriptions on drawings, and updating cable details on drawings.

A pre-solicitation notice seeks proposals for a construction project to add a third 3T MRI unit north of the existing MRI suite at the Louis Stokes VA Medical Center. The project scope includes renovating connecting areas and surrounding site, landscaping, sidewalks, and physical barriers. The solicitation documents will be posted on June 5, 2020. This is a 100% set-aside for verified Service-Disabled Veteran-Owned Small Businesses. Offerors must be classified as small businesses and registered in VIP and SAM databases. The construction work NAICS code is 236220 with a $39.5 million size standard. The contractor must perform a minimum of 15% of construction work.

View the file

Other files

File Type Posted
25 09 00 - Systems Integration.pdf PDF
Asbestos Report Jun 19 2019.pdf PDF
Revised Drawing M-202 Basement and First Floor HVAC Piping Plans.pdf PDF
Bid Opening Instructions.pdf PDF
Addendum No.1 Description.pdf PDF
Revised Drawing L103 Site Details.pdf PDF
Pre-Bid RFIs and Responses Sep 16 2020 update.pdf PDF
Revised Drawing T-301 Technology Details.pdf PDF
Revised Drawing M-701 Temperature Controls.pdf PDF
Revised Drawing E-301 One-Line Legend and Panelboard Schedules.pdf PDF
Revised Drawing E-302 Radiology One-Line Diagram.pdf PDF
26 33 53 - Static Uninterruptible Power Supply.pdf PDF
36C25020B0043 0001.docx DOCX document
Geotechnical Report Dec 15 2007.pdf PDF
Revised Drawing L100 Site Plans _ Demolition and Layout.pdf PDF
Expand MRI Suite - Site visit sign-in sheet Aug 27 2020.pdf PDF
Revised Drawing T-301 Technology Details.pdf PDF
Asbestos Report Jun 19 2019.pdf PDF
Revised Drawing L100 Site Plans _ Demolition and Layout.pdf PDF
Revised Drawing M-202 Basement and First Floor HVAC Piping Plans.pdf PDF
Pre-Bid RFIs and Responses Sep 16 2020 update.pdf PDF
Revised Drawing L103 Site Details.pdf PDF
Revised Drawing E-301 One-Line Legend and Panelboard Schedules.pdf PDF
Geotechnical Report Dec 15 2007.pdf PDF
Revised Drawing E-302 Radiology One-Line Diagram.pdf PDF
36C25020B0043 0001.docx DOCX document
Bid Opening Instructions.pdf PDF
Expand MRI Suite - Site visit sign-in sheet Aug 27 2020.pdf PDF
Revised Drawing M-701 Temperature Controls.pdf PDF
26 33 53 - Static Uninterruptible Power Supply.pdf PDF
25 09 00 - Systems Integration.pdf PDF
S02. VA MRI Final Volume 2 Drawings (FP,MG,P,M,E,T) Updated.pdf PDF
S02 - RFI Form .pdf PDF
36C25020B0043_1.docx DOCX document
S02. VA MRI Final Volume 1 Specs Updated.pdf PDF
Wage Determination.pdf PDF
S02. VA MRI Final Volume 2 Specs Updated.pdf PDF
36C25020B0043-001 - Site visit 08-27-2020.pdf PDF
S02. VA MRI Final Volume 3 Drawings (GE,PDC,PDC) Updated.pdf PDF
S02. VA MRI Final Volume 1 Drawings (G,V,L,A,I, Q,S) Updated.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

September 15, 2020

Louis Stokes Cleveland VA Medical Center

Cleveland, OH 44106

Attention: Kurt Rothermel

Regarding: MRI Addition

Addendum No. 1

Dear Mr. Rothermel, Please incorporate the following items in the upcoming addendum for the above referenced project.

Mechanical Items

1. Delete Specification Section 23 09 40 SYSTEMS INTEGRATION and replace with the attached

Specification Section 25 09 00 SYSTEMS INTEGRATION. The systems integration shall be the responsibility of the contractor for this project.

2. Refer to attached revised drawing M-202. Corrected graphical error of piping to CUH.

3. Refer to attached revised drawing M-701. Corrected some minor clerical errors.

Electrical Items

1. Refer to attached revised drawing E-301. Added panelboard schedule indicated and clarified UPS requirements in clouded area.

2. Refer to attached revised drawing E-302. Provided additional information regarding circuit breaker features and revised panelboard description indicated.

3. Refer to attached revised drawing T-301. Updated details to latest standard and added cable color detail.

END OF ADDENDUM NO. 1

Please contact me with any questions.

Sincerely yours, Fredrick, Fredrick & Heller Engineers, Inc

Leonard Hendrix, PE

Date 08/17/2020

Attachments:

1. Specification Section 25 09 00 SYSTEMS INTEGRATION.

2. Revised Mechanical Drawings M-202 and M-701.

File details come from the government source that posted it. Updated .