36C25019B0021-0001003.pdf
PDF 4 MB Posted
- Attached to
- 538-19-2-6983-0006 Upgrade IT Infrastructure to Support VoIP Phone System (VA-19-00037275)
- Solicitation number
- 36C25019B0021
About this file
36C25019B0021 0001 Chillicothe VA IT Upgrades_Drawings Bid Set.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25019B0021-0005001.pdf | ||
| 36C25019B0021-0005000.docx | DOCX document | |
| 36C25019B0021-0005002.pdf | ||
| 36C25019B0021-0004000.docx | DOCX document | |
| 36C25019B0021-0003000.docx | DOCX document | |
| 36C25019B0021-0002000.docx | DOCX document | |
| 36C25019B0021-0001002.docx | DOCX document | |
| 36C25019B0021-017.pdf | ||
| 36C25019B0021-015.docx | DOCX document | |
| 36C25019B0021-016.docx | DOCX document | |
| 36C25019B0021-018.pdf | ||
| 36C25019B0021-006.docx | DOCX document | |
| 36C25019B0021-000.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION PLAN
LOCATION MAP
VA MEDICAL CENTER
CHILLICOTHE, OHIO
UPGRADE IT INFRASTRUCTURE TO SUPPORT VOIP PHONE SYSTEM
G-001
DRAWING TITLE
TITLE SHEET / DRAWING INDEX
DRWG NO.
SHEET NO.
DRAWING INDEX
NAVFAC NO.
E101-01
--------4
BUILDING 01 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
E101-18
E101-24
E101-26
E101-27
E101-30
E101-31
E101-35
E101-210--------
E101-211
BUILDING 18 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
BUILDING 24 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
BUILDING 26 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
BUILDING 27 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
BUILDING 30 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
BUILDING 31 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
BUILDING 35 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
BUILDING 210 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
BUILDING 211 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL--------
E-501 DETAILS - ELECTRICAL
E-001 GENERAL INFORMATION - ELECTRICAL--------
12 --------
E102-31
E102-35
BUILDING 31 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
BUILDING 35 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
E101-03 BUILDING 03 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
--------18
E101-28 BUILDING 28 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL
E101-212 BUILDING 212 OVERALL FLOOR PLANS AND ENLARGED PLANS - ELECTRICAL--------17
OWNER
CHILLICOTHE VA MEDICAL CENTER
JERRY SINCLAIR (COR)
PROJECT ENGINEER
PHONE: (740) 773-1141 EXT. 6887
EMAIL: JERRY.SINCLAIR@VA.GOV
MEP DESIGNER
ADVANCED ENGINEERING CONSULTANTS
DAN JAMES
PROJECT MANAGER
8606 ALLISONVILLE ROAD, SUITE 270
INDIANAPOLIS, IN 46250
PHONE: (317) 413-5724
DIRECT: (317) 222-7871
EMAIL: DANJ@AECMEP.COM
PROJECT TEAM
Drawing Title
Reviewed for Concept Only
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of
Construction and Facilities
Management
JPA Project No.
Revision
Date
UPGRADE IT INFRASTRUCTURE
TO SUPPORT
VOIP PHONE SYSTEM
September 28, 2018
15005.00
#538-19-209
Chillicothe, Ohio
A DVANCED
E NGINEERING
C ONSULTANTS
Mechanical | Electrical | Plumbing | Fire Protection
8606 Allisonville Road, Suite 270 Tel: (317) 413-5724
Indianapolis, Indiana 46256 Fax: (614) 486-4082
BID SET
DJ AJ
TITLE SHEET/
DRAWING INDEX
G-001
AutoCAD SHX Text N
AutoCAD SHX Text O H I O
AutoCAD SHX Text
OHIO
AutoCAD SHX Text
RIVER
AutoCAD SHX Text
CHILLICOTHE VA MEDICAL CENTER
AutoCAD SHX Text
KENTUCKY
AutoCAD SHX Text
WEST
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
CINCINNATI
AutoCAD SHX Text
COLUMBUS
AutoCAD SHX Text
INDIANA
AutoCAD SHX Text
PENNSYLVANIA
AutoCAD SHX Text
CLEVELAND
AutoCAD SHX Text
TOLEDO
AutoCAD SHX Text
DAYTON
AutoCAD SHX Text
SPRINGFIELD
AutoCAD SHX Text
ZANESVILLE
AutoCAD SHX Text
AKRON
AutoCAD SHX Text
CANTON
AutoCAD SHX Text
LIMA
AutoCAD SHX Text
ATHENS
AutoCAD SHX Text
HAMILTON
AutoCAD SHX Text
YOUNGSTOWN
AutoCAD SHX Text
SANDUSKY
AutoCAD SHX Text
MICHIGAN
AutoCAD SHX Text No 10708835
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
ABBREVIATIONS
NOTE: NOT ALL ABBREVIATIONS MAY BE USED.
PHASE
(A) EXISTING TO BE ABANDONED
(D) EXISTING TO BE DEMOLISHED
(E) EXISTING TO REMAIN
(F) FUTURE
(R) EXISTING TO BE RELOCATED
A AMPERE
AC ALTERNATING CURRENT OR AIR CONDITIONER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC AMPS INTERRUPTING CAPACITY
ANNC ANNUNCIATOR
AWG AMERICAN WIRE GAUGE
BPS BOLTED PRESSURE SWITCH
C CONDUIT
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CM CONSTRUCTION MANAGER
DC DIRECT CURRENT
DP DISTRIBUTION PANELBOARD
DTT DOUBLE TWIN TUBE
EB ELECTRONIC BALLAST
EC ELECTRICAL CONTRACTOR
EM EMERGENCY
EMT ELECTRICAL METAL TUBING
EWC ELECTRIC WATER COOLER
FA FIRE ALARM
FLA FULL LOAD AMPS
G GROUND
GC GENERAL TRADES CONTRACTOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GEN GENERATOR
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HPC HIGH PRESSURE CONTACT SWITCH
HZ HERTZ
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCD INCANDESCENT
KVA KILOVOLT AMPERE
KW KILOWATT
LTG LIGHTING OR LIGHT
LRA LOCKED ROTOR AMPS
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MLO MAIN LUGS ONLY
MOCP MAXIMUM OVERCURRENT PROTECTION
MSB MAIN SWITCHBOARD
MH METAL HALIDE
MTS MANUAL TRANSFER SWITCH
NAC NOTIFICATION APPLIANCE CIRCUIT
NC NORMALLY CLOSED
NO NORMALLY OPEN
NF NON-FUSED
OCC OCCUPANCY
PA PUBLIC ADDRESS
PB PULL BOX OR PUSH BUTTON
PH PHASE
PVC POLYVINYL CHLORIDE (PLASTIC PIPE)
PWR POWER
RECPT RECEPTACLE
STP SHIELDED, TWISTED PAIR
TC TIME CLOCK
TCC TEMPERATURE CONTROLS CONTRACTOR
TCP TEMPERATURE CONTROL PANEL
TRT TRIPLE TUBE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UTP UNSHIELDED, TWISTED PAIR
V VOLT
W WATT
WAP WIRELESS ACCESS POINT
WH WATTHOUR
WP WEATHERPROOF, NEMA 3R UNO
XFMR TRANSFORMER
Z IMPEDANCE
F,C
F,C
X Y Z
M
J
VFD
CP
SPD
HH
POWER SYMBOLS
NOTE: NOT ALL SYMBOLS MAY BE USED.
20A DUPLEX RECEPTACLE WITH COVER PLATE:
X=TYPE, Y"=NON-STANDARD MOUNTING HEIGHT,
U=WITH DUAL USB PORTS, (18" AFF TYPICAL)
U X Y
FLOOR OR CEILING MOUNTED DUPLEX
RECEPTACLE: F=FLOOR, C=CEILING
DUPLEX RECEPTACLE: ABOVE COUNTER (48"
AFF TYPICAL)
DOUBLE-DUPLEX RECEPTACLE WITH SINGLE
COVER PLATE, PROVIDE DEEP J-BOX
SIMPLEX RECEPTACLE WITH COVER PLATE
WALL MOUNTED SPECIAL RECEPTACLE: REFER
TO PLANS FOR ADDITIONAL INFORMATION
FLOOR OR CEILING MOUNTED SPECIAL
RECEPTACLE: F=FLOOR, C=CEILING REFER
TO PLANS FOR ADDITIONAL INFORMATION
SURFACE MOUNTED RACEWAY
STANDARD DISCONNECT SWITCH:
X=DISCONNECT SIZE, Y=NUMBER OF POLES
X Y Z
STANDARD FUSED DISCONNECT SWITCH:
X=DISCONNECT SIZE, Y=FUSE SIZE, Z=NUMBER
OF POLES
X Y Z
MOTOR STARTER: X=STARTER SIZE,
Y=NUMBER OF POLES
X Y Z
COMBINATION MOTOR STARTER/DISCONNECT
SWITCH: X=STARTER SIZE, Y=FUSE SIZE,
Z=NUMBER OF POLES
MOTOR (BY OTHERS): PROVIDE POWER AS
INDICATED
UTILITY METER
FRACTIONAL HORSEPOWER MANUAL MOTOR
STARTER
JUNCTION BOX
TRANSFORMER
HANDHOLE/POLE BOX: SEE DETAILS FOR
ADDITIONAL INFORMATION
CONTROL PANEL
SURGE PROTECTIVE DEVICE
PANELBOARD
AUTOMATIC TRANSFER SWITCH
VARIABLE FREQUENCY DRIVE (BY DIVISION 23)
PUSH BUTTON
POWER POLE
CORD REEL
GROUND ROD
DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT
WITH COVER PLATE: X=TYPE,
Y"=NON-STANDARD MTG HEIGHT, Z=SPECIAL
DESIGNATION, (18" AFF TYPICAL)
X Y Z
M
POKE THROUGH SERVICE FITTING: X=TYPEPT X
WEATHER RESISTANT DUPLEX RECEPTACLE,
GROUND FAULT CIRCUIT INTERRUPTING WITH
IN-USE COVER
WP
ATS
GENERAL NOTES
X WALL MOUNTED DATA OUTLET: X=# OF PORTS
A. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED
LABOR, MATERIAL, EQUIPMENT, AND CONTRACTOR SERVICES
NECESSARY TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED IN
FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE
FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE IN EVERY
DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE
SYSTEM.
B. ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE
STATE AND LOCAL CODES, ORDINANCES, UTILITY COMPANY
REGULATIONS AND NATIONALLY ACCEPTED CODES AND STANDARDS.
THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN
CORRECTING ANY NONCOMPLIANCE WITH THE REQUIREMENTS OF
APPLICABLE CODES.
C. ELECTRICAL CONTRACTOR SHALL COORDINATE ANY ELECTRICAL OR
LIGHTING REQUIREMENTS OF MILLWORK WITH ARCHITECTURAL
WOODWORK/CASEWORK CONTRACTOR AS NECESSARY.
D. DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS.
STAGGER AS REQUIRED TO MINIMIZE SOUND TRANSMISSION.
E. CONTRACTOR SHALL UPDATE ALL PANEL SCHEDULES MODIFIED.
F. ALL MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE OR
CENTER OF OPERABLE PORTION.
G. WHERE MULTIPLE DEVICES ARE LINED UP ON A WALL, THE TOP OF
THE BOXES' FINISH PLATES SHALL ALL LINE UP. THE ELEVATION
SHALL BE AS NOTED FOR THE GENERAL PURPOSE DEVICES.
H. PAINT ALL EXPOSED CONDUITS AND BOXES IN FINISHED AREAS.
I. PROTECT AND MAINTAIN PROPER CLEARANCE AROUND THE
TELECOMMUNICATIONS INFRASTRUCTURE BEFORE AND AFTER
CONSTRUCTION.
J. RECEPTACLES SHALL NOT BE WIRED BACK TO BACK BETWEEN
SEPARATE ROOMS. RECEPTACLE CIRCUITS SHALL BE EXTENDED UP
TO ABOVE CEILING AT EACH DEVICE LOCATION.
K. MINIMUM CONDUCTORS SIZE SHALL BE #12 AND MUST COMPLY WITH
TABLE 310.16 OF NATIONAL ELECTRICAL CODE (NFPA70, LATEST
EDITION). WHERE CIRCUIT RUNS EXCEED 100' THE CONTRACTOR
SHALL INCREASE THE WIRE SIZE TO THE NEXT NOMINAL VALUE TO
ACCOUNT FOR VOLTAGE DROP.
L. REFER TO DRAWINGS AND SPECIFICATIONS OF OTHER TRADES FOR
ADDITIONAL WORK REQUIRED BY THE DIVISION 26 THRU 28
CONTRACTORS.
M. CONTRACTOR SHALL PROVIDE A NEAT AND ORDERLY
PROFESSIONAL INSTALLATION. ALL LOCAL CODES SHALL BE
STRICTLY ADHERED TO AS A MINIMUM. ALL REQUIREMENTS OF THE
LATEST APPROVED ADDITION OF NFPA 70E SHALL BE FOLLOWED.
N. ALL CIRCUITS SHALL HAVE A SEPARATE NEUTRAL PER OVER
CURRENT PROTECTION DEVICE HANDLE.
O. MAXIMUM FILL FOR A 3/4" CONDUIT SHALL BE SIX CURRENT
CARRYING CONDUCTORS.
P. CONDUITS INSTALLED IN EXPOSED CEILINGS TO BE RUN PARALLEL
AND PERPENDICULAR TO BUILDING FRAME. ALL CIRCUITS TO BE IN
CONDUIT.
Q. SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS WITH FIRE
STOP TO MAINTAIN ASSEMBLY RATING.
R. EXTRA DEEP OUTLET BOXES MUST BE USED WHERE RECEPTACLES
WITH USB PORTS ARE INSTALLED.
S. ALL EMPTY CONDUIT SYSTEMS SHALL HAVE PULL WIRE WITH PULL
BOXES EVERY 2ND 90 DEGREE TURN (OR ACCUMULATION OF 180
DEGREES IN TURNS), ON EACH SIDE OF FLOOR OR WALL
PENETRATIONS, AND EVERY 100'.
T. ELECTRICAL/DATA OUTLET LOCATIONS TO BE COORDINATED PRIOR
TO ROUGH-IN. ALL LOCATIONS TO BE VERIFIED WITH FURNITURE
PLACEMENT. ALL VOICE/DATA AND AV OUTLETS SHALL BE WITHIN 12"
OF A POWER OUTLET.
U. ELECTRICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF
ALL NEW SWITCHES, LIGHT FIXTURES, BALLASTS, EXIT, AND
EMERGENCY LIGHTS AND OUTLETS AND SHALL REPLACE ANY
NON-OPERATIONAL UNITS.
V. DO NOT SCALE DRAWINGS. ALL DIMENSIONS GIVEN ARE TO BE
ADHERED TO UNLESS FIELD CONDITIONS DEEM OTHERWISE. ANY
CONFLICTS THAT MAY EXIST WITH NEW CONSTRUCTION MUST BE
REVIEWED BY ENGINEER PRIOR TO CONSTRUCTION OF WORK. DO
NOT CIRCUMVENT DIMENSIONS BY ATTACHING RECEPTACLES TO
NEAREST STUD.
W. ALL EQUIPMENT FEEDERS SHALL INCLUDE A NEUTRAL UNLESS
NOTED OTHERWISE.
X. CONTRACTOR SHALL PROVIDE ELECTRICAL CONNECTIONS TO ALL
EQUIPMENT, COORDINATE REQUIREMENTS ACROSS ALL TRADES.
Y. RIGID CONDUIT SHALL BE USED TO TRANSITION THRU FLOORS,
WALLS, AND ROOF. MINIMUM CONDUIT SIZE SHALL BE 3/4".
Z. CONDUIT SHALL BE EMT. MC OR AC CABLE IS NOT PERMITTED.
X
C,F
X
C,F
X
C,F
TELECOMM SYMBOLS
NOTE: NOT ALL SYMBOLS MAY BE USED.
WALL MOUNTED PHONE OUTLET (42" AFF): SEE
TELECOM OUTLETS DETAIL
CEILING OR FLOOR MOUNTED PHONE OUTLET:
SEE CEILING / FLOOR BOX SCHEDULE
WALL MOUNTED DATA OUTLET (18" AFF): SEE
TELECOM OUTLETS DETAIL
SURFACE MOUNTED RACEWAY
CABLE TRAY
EQUIPMENT RACK
TELEPHONE TERMINAL BOARD/PLYWOOD
BACKBOARD: REFER TO PLANS FOR ACTUAL
LENGTHS
CEILING OR FLOOR MOUNTED DATA OUTLET:
SEE CEILING / FLOOR BOX SCHEDULE
WALL MOUNTED PHONE/DATA OUTLET (18" AFF):
SEE TELECOM OUTLETS DETAIL
CEILING OR FLOOR MOUNTED PHONE/DATA:
SEE CEILING / FLOOR BOX SCHEDULE
WIRELESS ACCESS POINT ROUGH IN. PROVIDE
(1) DATA JACK IN SINGLE GANG BOX /
FACEPLATE. ACCESS POINT BY OWNER.
TGB TELEPHONE GROUND BAR
Drawing Title
Reviewed for Concept Only
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of
Construction and Facilities
Management
JPA Project No.
Revision
Date
UPGRADE IT INFRASTRUCTURE
TO SUPPORT
VOIP PHONE SYSTEM
September 28, 2018
15005.00
#538-19-209
Chillicothe, Ohio
A DVANCED
E NGINEERING
C ONSULTANTS
Mechanical | Electrical | Plumbing | Fire Protection
8606 Allisonville Road, Suite 270 Tel: (317) 413-5724
Indianapolis, Indiana 46256 Fax: (614) 486-4082
BID SET
DJ AJ
GENERAL INFORMATION -
ELECTRICAL
E-001
AutoCAD SHX Text No 10708835
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
Tele Clos
T M
G B
2-ELN-4
M
(G) (G)
(E)
(E)
2 3
Tele Clos
T M
G B
2-ELS-31
M
(G) (G)
(E)
(E)
Tele Clos
T M
G B
2-ELN-6
2-ELN-12
M
(E) 4
(G) (G)
3Comm Clos
T M
G B
2-ELS-32 7
(E)
(G) (G)
DN
DN
DN
UP UP
UP
Risk
Manager
Performance
Measure
Coordinator
Patient
Safety
Contracting
Liason Office
Female Toilet
Elec Clos
Staff Toilet
Voucher
Examiner &
Employee
Travel
Contract
Specialist
Contract
Spec Intern
Supply Tech
Chief
Acquisitions/
Contracting
Contract
Liason
Contract
Specialist
Contract
Specialists
Admin
Support
Assist
Chief
Logistics
Inventory
Management
Spec
Item
Manager
Item
Manager
Item
Manager
Xerox/supplies
Staff Toilet
Files Storage
Tele Clos
Filing
Supplies
Utilization
Nurse
Hac
Performance
Measure
Coordinator
Program
Support
Assistant
Systems
Design
Coordinator
Hac
Copy Room
Tele Clos
Male Toilet
Female Toilet
Tele Closet
Hrm
Resource
Room
Resident
Intern
Program
Outreach
Assistant
Coordinator
Public Affairs
Offices
Aa To Ad
Credentials &
Pc
Aa To Cos
Credentials
Priveleging
Assistant
Director's
Conference
Chief Of Staff
Secretary
Chief Of Staff
Management
Asst
Exec Asst
For
Operation
Secretary
Medical Ctr
Dir
Medical
Center
Director
Assoc
Director
Secretary A
Director
Stor/coat Rm
Coffee Rm
A.d. Patient
Care Svcs
Ad/pcs
Library
Secretary, Ad/pcs
Elec Clos
Eeo Manage
Quality
Improvement
Facilitator
Quality
Manager
QI Program
Asst
Toilet
169A
Lobby/waiting
Area
1L001
Corridor
1C002
Corridor
1C006
Corridor
1C005
Corridor
1C010
Corridor
1C009
External
Review
Manager
Male Toilet
Accounting
Accounting
Chief
Accountant
Assistant
Finance
Officer
Chief Fiscal
Secretary, Fiscal Svc
Budget
Analysts
Xerox Files
Payroll Techs
Conference
Rooms
Chief
Inventory
Supply
Support
Break Room
Employee
Benefits
Section
Punlic Affairs
Specialist
Tele Conf
Rm
Waiting Area
1L002
Corridor
1C007
Stair
S2-1
Stair
S1-1
Corridor
1C003
UP
UP
UPUP
UP
DN
Training
Room
BB103
Bowling Alley
BC100B
Game Room
BC100
Tele
Equipment
BB105
Records
Storage
BA110
Mds Records
Storage
BA112
Admin Office
Academic
Affairs
BA114
Admin Officer
Gecl
BA111
Palliative
Care
BA109
Associate
Chief Nurse
BA107
Palliative
Care
Coordination
BA105
Community
Health Nurse
BA103
Comm Social
Worker
BA108
Corridor
CB3
Pharmacist
BA101A
Nursing
Storage
BA102
Elec Clos
BC100F
Elec Clos
BC100E
Vestibule
BC100D
Stair
S1-0
Corridor
CB5
Mech
Equipment
BB106
Mens Toilet
BB107
Corridor
CB4
HAC
BA100
Stair
S2-0
Corridor
CB1
Storage
BB101A
Vet Director
Coordinator
BA101B
Gecl Clinical
Liason/ Non
Va Case Rn
BA101C
Women
BA104
Corridor
CB2
Pin Setting
Equip
BC100C
Game Room
BC100A
Supply Room
BC100G
Rec Storage
BB102
Cio
Equipment
Storage
BB101
Dep Cos
BA116
Ao Rehab
Services
BA113
Corridor
CB6
Engineering
Room
BB104
Tele Clos
BB104A
Storage
BB100
Men
BA106
Tele Clos
BA102A
Crawl Space Crawl Space
DN
UP
DN
UP
E101-01
E101-01
E101-01
E101-01
2-ELS
PANELS:
2-LN
2-ELN
2-LS
2-LN
2-ELN
PANELS:
2-ELS
2-LS
Health
Systems
Spec Pcs
Emergency
Preparedness
Coordinator
Patient
Business
Intern
Assistant
Patient
Business
Manager
Customer
Service
Coordinator
Female Toilet
Male Toilet
Elec Clos
Piv Room
File Room
Hrm
Specialist
Hrm Assist
Hrm
Specialist
Admin Asst
Chief Hrm
Assistant
Hrm Officer
Storage
Hrm
Specialist
Hrm
Specialist
Conference
Room
Security
Specialist
Regional
Counsel Conf
Regional
Counsel
Library
Hr Assistants
Copy/mail
Room
Hrm Office
Intern Office
Hrm Office
Resource
Room
Hrm
Specalists
Vet Pro
Hrm Office
Hrm Office
Hrm Office
Tele Clos
Employee
Resources
Hrm
Assistant
Dss Liason
Interior
Designer
Conference/training
Facility
Telehealth
Coordinator
Hac/utility
Break Room
Tele Clos
Male Toilet
Female Toilet
Clos
Education
And Training
Hr Officer
Hrm
Assistant
Admin Asst
For Patient
Care
Chief
Education
And Training
Secretary
Education
And Training
Training
Technician
Budget
Technician
Ccht Mental
Health
Video
Conference
Academic
Affiliations
Conference/
Training
Care
Coordination
Nurse
Escorts
Nurse
Educator
Nurse
Educator
Clinic Liason
Nurse
Educator
Nurse
Educator
Care
Coordinator
Care
Coordinator
Care
Coordinator
Nurse
Manager
Nursing Time
Keeper
Staff Toilet
Program
Support
Assistant
Program
Support
Assistant
Xerox/mail/forms
Elec Clos
Nurse
Training
Storage
Training
Room
Training
Room
Corridor
2C008
Corridor
2C007
Corridor
2C009
Corridor
2C4
Regional
Counsel
Office
224A
Corridor
2C5
Regional
Counsel
Office
224B
Patient
Business
Service
Manager
245A
Heart Code
Room
Comm Clos
Corridor
2C003
Corridor
2C002
Corridor
2C001
Corridor
2C006
Stair
S1-2
Stair
S2-2
Drawing Title
Reviewed for Concept Only
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of
Construction and Facilities
Management
JPA Project No.
Revision
Date
UPGRADE IT INFRASTRUCTURE
TO SUPPORT
VOIP PHONE SYSTEM
September 28, 2018
15005.00
#538-19-209
Chillicothe, Ohio
A DVANCED
E NGINEERING
C ONSULTANTS
Mechanical | Electrical | Plumbing | Fire Protection
8606 Allisonville Road, Suite 270 Tel: (317) 413-5724
Indianapolis, Indiana 46256 Fax: (614) 486-4082
BID SET
DJ AJ
BUILDING 01
OVERALL FLOOR PLANS
AND ENLARGED PLANS -
ELECTRICAL
E101-01
8' 16' 32'03/64"=1'-0"1
OVERALL BASEMENT FLOOR PLAN
8' 16' 32'03/64"=1'-0"2
OVERALL FIRST FLOOR PLAN
8' 16' 32'03/64"=1'-0"3
OVERALL SECOND FLOOR PLAN
GENERAL NOTES:
A. CIRCUITS SHOWN ARE SUGGESTIONS, CONTRACTOR MAY
CONNECT TO A DIFFERENT PANEL. CONNECT NEW CIRCUITS
TO LOCAL PANEL WITH AVAILABLE BREAKER SPACE OF
APPROPRIATE SIZE.
B. MECHANICAL EQUIPMENT (EXHAUST FANS AND SPLIT SYSTEMS)
ARE PROVIDED BY OWNER. E.C. SHALL MAKE FINAL ELECTRICAL
CONNECTIONS.
C. CEILING TYPES ARE NOTED IN ROOMS AND HALLWAYS WITH
SCOPE.
(G) = GRID / LAY-IN CEILING
(O) = OPEN CEILING
(GYP) = GYPSUM BOARD CEILING
CODED NOTES:
1. EXHAUST FAN: CONNECT TO 20A/1P CIRCUIT IN LOCAL PANEL.
COORDINATE LOCATION WITH OWNER PRIOR TO ROUGH-IN.
2-#12, 1-#12 G, 3/4" C.
2. EXISTING PLYWOOD BACKBOARD TO REMAIN.
3. EXISTING TELECOM GROUND BAR TO REMAIN.
4. EXISTING OUTLET TO REMAIN.
5. EXISTING TELECOM RACK TO REMAIN.
6. E.C. SHALL INSTALL OWNER PROVIDED MOTOR RATED TOGGLE
SWITCH FOR EXHAUST FAN.
7. NEW RECEPTACLE. CONNECT TO LOCAL 20A/1P CIRCUIT.
N
01/4"=1'-0" 2' 4' 8'6
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'5
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'4
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'7
ENLARGED PLAN - ELECTRICAL
N
N
AutoCAD SHX Text No 10708835
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
Telephone
(E)
(G)
TMGB
(O) (E)
(E)
3-1S-3-48,50
UP
DN
DN
UP
UP
UP
UP
DN
DN
Kitchen/
Dining
106D
Supply
106C
HAC
106E
Toilet
106F
Toilet
106G
Corridor
C1-3
Corridor
C1-1
Vet Rep
107A
Corridor
108E
Book Rehab
108A
Book Rehab
108D
Toilet
108G
Conf./Classroom
108C
Marketing &
Service Rep
108B
Day
Treatment
Office
Program
Assistant
Forms
Storage
110A
Elec Closet
111A
Staff Toilet
Telephone
Office
Incentive
Therapy
Vestibule
Conference
101L
Toilet
114B
Toilet
114C
Sports
Imaging
Classroom
114D
Office
101J
Office
101H
Mechanical
101E
Office
101G
Women's
100K
Office
100G
Office
100E
Office
100F
Office
100J
Shared
Waiting
Office
100I
Stair
S2-1
Stair
S1-1
Elec.
100A
Office
101F
Office
101P
Office
101K
Office
101M
Office
100H
Office
100D
Supply
100B
Office
100C
Men's
100MOffice
101I
Office
100L
Corridor
Corridor
101D
Clos.
101B
Existing Day
Treatment
Clinic
Supply
106I
Storage
106J
Group Room
106N
Existing Dark
Room
106A
Waiting
Corridor
106B
HAC
101C
Veteran's
Industries
Marketing
Storage
106K
Storage
106L
Closet
114E
Mechanical
Room
106M
Corridor
C1-2
Closet
108H
Classroom
114A
E101-03
3-1N-2
PANELS:
3-1N-1 3-1N-2
3-1N-1
PANEL:
3-1S-3
3-1S-3
Drawing Title
Reviewed for Concept Only
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of
Construction and Facilities
Management
JPA Project No.
Revision
Date
UPGRADE IT INFRASTRUCTURE
TO SUPPORT
VOIP PHONE SYSTEM
September 28, 2018
15005.00
#538-19-209
Chillicothe, Ohio
A DVANCED
E NGINEERING
C ONSULTANTS
Mechanical | Electrical | Plumbing | Fire Protection
8606 Allisonville Road, Suite 270 Tel: (317) 413-5724
Indianapolis, Indiana 46256 Fax: (614) 486-4082
BID SET
DJ AJ
E101-03
BUILDING 03
OVERALL FLOOR PLANS
AND ENLARGED PLANS -
ELECTRICAL
01/4"=1'-0" 2' 4' 8'2
ENLARGED PLAN - ELECTRICAL
N4' 8' 16'03/32"=1'-0"1
OVERALL FIRST FLOOR PLAN
GENERAL NOTES:
A. CIRCUITS SHOWN ARE SUGGESTIONS, CONTRACTOR MAY
CONNECT TO A DIFFERENT PANEL. CONNECT NEW CIRCUITS
TO LOCAL PANEL WITH AVAILABLE BREAKER SPACE OF
APPROPRIATE SIZE.
B. MECHANICAL EQUIPMENT (EXHAUST FANS AND SPLIT SYSTEMS)
ARE PROVIDED BY OWNER. E.C. SHALL MAKE FINAL ELECTRICAL
CONNECTIONS.
C. CEILING TYPES ARE NOTED IN ROOMS AND HALLWAYS WITH
SCOPE.
(G) = GRID / LAY-IN CEILING
(O) = OPEN CEILING
(GYP) = GYPSUM BOARD CEILING
CODED NOTES:
1. SPLIT SYSTEM INDOOR UNIT: COORDINATE LOCATION WITH
OWNER PRIOR TO ROUGH-IN.
2. RECEPTACLE FOR SPLIT SYSTEM CONDENSATE PUMP. MOUNT
AT HEIGHT OF AND WITHIN 1' OF INDOOR UNIT. CONNECT TO
EXISTING LOCAL RECEPTACLE CIRCUIT AS INDICATED.
3. SPLIT SYSTEM OUTDOOR UNIT: COORDINATE LOCATION AND
MOUNTING HEIGHT WITH OWNER PRIOR TO ROUGH-IN.
4. E.C. SHALL PROVIDE 30A/2P, NEMA 3R FUSIBLE DISCONNECT.
5. CONNECT INDOOR AND OUTDOOR UNITS. ROUTE 3-#12, 1-#12 G
IN 3/4" C.
6. EXISTING OUTLET TO REMAIN.
7. NEW TELECOM BUSBAR.
8. EXISTING TELECOM RACK TO REMAIN.
9. EXISTING PLYWOOD BACKBOARD TO REMAIN.
AutoCAD SHX Text No 10708835
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
E101-18
DN
UP
UP
UP
Corridor
Men's
Women's
Locker Room
PIV Office
Court Room
Arms Room
Secretary
Locker Room
Photo ID
Operation
Officer
Watch CMDR
011A
HAC
Elec.
Switchgear
Storage
Corridor
Stairs
Jury Room
005A
Waiting
Room
005B
Police Chief
007A
Mech.
Equipment
007B
LAB
009A
Evidence
011B
Operations
Desk
011C
Mech.
Equipment
011F
Corridor
Telephone
Equipment
012A
Storage
012B
Toilet
012C
Tele
Batteries
012D
Corridor
012E
Corridor
016A
Mech.
Equipment
014A
Interview/
Conference
011G
Tele Ops
Work Room
011D
Storage
012F
Closet
012G
Corridor
012H
Waiting
Lobby
Network/Admin.
Operation
Specialist
Customer
Service
Customer
Support
Manager IT
Operator
Chief
Information
Officer
Advanced
Support
Program
Support
Assistant
Copy Room
Toilet Room
Customer
Support
Coms Closet
OIT Region 3
Manager
Client
Technologies
Applications
Web
Administration
Toilet Room
HAC
Computer
Equipment
Mech.
Applications
Business
Systems
Customer
Support
Server
Administrator
Corridor
Corridor
HAC
111A
Storage
110A
Toilet
107A
Conference
Corridor
Break Room
Office
Program
Analyst CBI
Supervisory
Administrative
Office
Restroom
PPCC
Administrative
Support
Assistant
Secretary
Primary Care
Primary Care
Line Manager
Police
Training
Room
Office
Fire Alarm
Closet
VSN 10
Homeless
Coordinator
Chief HIMS
Courtroom
Waiting
Computer
Training
Mech. Room
Restroom
CBO Field
Office
CBO Field
Office
Information
Security
Officer
Corridor
Corridor
Corridor
Stairs
Office
HAC
205A
WMC HR &
SS A-HRC
Consultant
215A
HAC
217A
E101-18
E101-18
E101-18
EPB-1
B A C
2XX
PANEL:
EPB-1
PANELS:
A B C
1C
PANEL:
1C
EMG-2
PANEL:
EMG-2
GENERAL NOTES:
A. CIRCUITS SHOWN ARE SUGGESTIONS, CONTRACTOR MAY
CONNECT TO A DIFFERENT PANEL. CONNECT NEW CIRCUITS
TO LOCAL PANEL WITH AVAILABLE BREAKER SPACE OF
APPROPRIATE SIZE.
B. MECHANICAL EQUIPMENT (EXHAUST FANS AND SPLIT SYSTEMS)
ARE PROVIDED BY OWNER. E.C. SHALL MAKE FINAL ELECTRICAL
CONNECTIONS.
C. CEILING TYPES ARE NOTED IN ROOMS AND HALLWAYS WITH
SCOPE.
(G) = GRID / LAY-IN CEILING
(O) = OPEN CEILING
(GYP) = GYPSUM BOARD CEILING
CODED NOTES:
1. CONNECT EXISTING TMGB TO RACK.
2. NEW RECEPTACLE. CONNECT TO LOCAL 20A/1P CIRCUIT.
3. EXISTING WIREMOLD TO REMAIN.
4. NEW TELECOM BUSBAR. ANCHOR BUSBAR TO WALL OR TO
LADDER RACK. EXTEND GROUND WIRE TO EACH RACK.
5. EXISTING OUTLET TO REMAIN.
6. EXISTING PLYWOOD BACKBOARD TO REMAIN.
7. EXISTING TELECOM RACK TO REMAIN.
Telephone
Equipment
012A
T M
G B
(E)
(G)
Computer
Equipment
TMGB
(G)
(TYP.)
(G)
Coms Closet
T M
G B
(E) (E)
(E)
5(G)
(G)
2XX
TMGB
EMG-2-6
1 2
(E)
(G) (G)
Drawing Title
Reviewed for Concept Only
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of
Construction and Facilities
Management
JPA Project No.
Revision
Date
UPGRADE IT INFRASTRUCTURE
TO SUPPORT
VOIP PHONE SYSTEM
September 28, 2018
15005.00
#538-19-209
Chillicothe, Ohio
A DVANCED
E NGINEERING
C ONSULTANTS
Mechanical | Electrical | Plumbing | Fire Protection
8606 Allisonville Road, Suite 270 Tel: (317) 413-5724
Indianapolis, Indiana 46256 Fax: (614) 486-4082
BID SET
DJ AJ
E101-18
N
4' 8' 16'03/32"=1'-0"1
OVERALL BASEMENT FLOOR PLAN
4' 8' 16'03/32"=1'-0"2
OVERALL FIRST FLOOR PLAN
4' 8' 16'03/32"=1'-0"3
OVERALL SECOND FLOOR PLAN
BUILDING 18
OVERALL FLOOR PLANS
AND ENLARGED PLANS -
ELECTRICAL
01/4"=1'-0" 2' 4' 8'4
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'7
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'5
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'6
ENLARGED PLAN - ELECTRICAL
N
N
AutoCAD SHX Text No 10708835
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
Tele Clos
124E
TMGB1LE2-26
1L3
(E) (E)
(G) (G)
M
Tele Clos
GB103
T M
G B
4KPE-1,3
(E)
(E)
(G)
(G)
(E)9
Tele Clos
TMGB
12LE2-25
2L3
(E)(E)
6 7
(G)
(G)
88 M
GENERAL NOTES:
A. PANEL NAMES SHOWN FOR NEW CIRCUITS ARE SUGGESTIONS.
CONNECT NEW CIRCUITS TO LOCAL PANEL WITH AVAILABLE
BREAKER SPACE OF APPROPRIATE SIZE.
B. MECHANICAL EQUIPMENT (EXHAUST FANS AND SPLIT SYSTEMS)
ARE PROVIDED BY OWNER. E.C. SHALL MAKE FINAL ELECTRICAL
CONNECTIONS.
C. CEILING TYPES ARE NOTED IN ROOMS AND HALLWAYS WITH
SCOPE.
(G) = GRID / LAY-IN CEILING
(O) = OPEN CEILING
(GYP) = GYPSUM BOARD CEILING
CODED NOTES:
1. EXHAUST FAN: CONNECT TO 20A/1P CIRCUIT IN LOCAL PANEL.
COORDINATE LOCATION WITH OWNER PRIOR TO ROUGH-IN.
ROUTE 3/4"C, 2-#12, 1-#12G.
2. SPLIT SYSTEM INDOOR UNIT: COORDINATE LOCATION WITH
OWNER PRIOR TO ROUGH-IN.
3. RECEPTACLE FOR SPLIT SYSTEM CONDENSATE PUMP. MOUNT
AT HEIGHT OF AND WITHIN 1' OF INDOOR UNIT. CONNECT TO
EXISTING LOCAL RECEPTACLE CIRCUIT AS INDICATED.
4. SPLIT SYSTEM OUTDOOR UNIT: COORDINATE LOCATION AND
MOUNTING HEIGHT WITH OWNER PRIOR TO ROUGH-IN.
5. CONNECT INDOOR AND OUTDOOR UNITS. ROUTE 3-#12, 1-#12 G
IN 3/4" C.
6. EXISTING PLYWOOD BACKBOARD TO REMAIN.
7. NEW TELECOM BUSBAR.
8. EXISTING OUTLET TO REMAIN.
9. EXISTING TELECOM RACK TO REMAIN.
10. E.C. SHALL INSTALL OWNER PROVIDED MOTOR RATED TOGGLE
SWITCH FOR EXHAUST FAN.
11. E.C. SHALL PROVIDE 30A/2P, NEMA 3R FUSIBLE DISCONNECT.
UP
UP
UP
UP
UP
UP
UP
UP
DN
UP
UP
UP
UP
UP
DN
DN
DN
DN
Nourishment
Kitchen
GB120
Elec Clos
GB116B
Cook/Chill
GB116
Dietician /
Food Service
Supervisor
GB118
Mech Equip
GB108
Toilet
GB116A
Emp Break
Room
GB106
Soiled Linen
GB104
Elec
Switchgear
GB102
HAC
GB109
Prosthetics &
Sensory Aids
Service
GB111
Corridor
GBC1
Prosthetics
Check In
GB111A
Break
Room/Storage
GB111B
Chief of
Prosthetics
GB113
Stairs
GBS1
EMS Stor
GB107
EMS Office
GB105
Housekeeping
Supervisor
GB105A
Linen
Storage
GB103A
Tele Clos
GB103
Vending
Room
GB101
Mech
Equipmt
GB101A
HAC
GB121
Rec Stor
GA101
Mech
Equipmt
GA100
Mech
Equipmt
GA102
Stairs
GSD1
Mech
Equipmt
GA103
Female
Locker/Toilet
GA104
Male Toilet
GA105
Cart Wash
GC106A
Men
Locker/Toilet
GC105
Corridor
GCC1
SPS
Decontamination
GC106
Mech
Equipmt
GC106B
SPD
Sterilization
GC108A
Sterilization
Room
GC108
Stairs
GCS1
Quality Room
GC109B
Assistant
Chief SPS
GC110
SPS Chief
GC111
Mech
Equipmt
GC112
Storage
GC113
GC113B
GC113A
Elev Lobby
GAC1
Elec Clos
GC115
Elec Clos
GC114
Elec Clos
GB117
SPD
Distribution
GC109
GC109A
HAC
GB109A
Emergency
Generator
GA100A
Toilet/Shower
213A
Bed Room
213B
Bed Room
213C
Entry
Toilet/Shower
214A
Entry
Bed Room
214B
Bed Room
214C
Corridor
2C3
Bed Room
215A
Bed Room
215B
Entry
Toilet/Shower
215C
Bed Room
Toilet/Bath
216A
Physician
Assist/Exam
Laundry
Room
Soiled Linen
219A
Linen Chute
Crash Carts
Stor
221A
Addiction
Therapist
Tele Clos
Day
Rm/Training
Corridor
2C4
Staff Toilet
Stairs
2S1
Addiction
Therapist
Visitor Room
Ice/Water
Kitchenette
Stor
Clean Linen
Staff
Restroom
Aftercare
Coordinator
Psychology
Technician
Stairs
2S2
Addiction
Therapist
Addiction
Therapist
Bed Room
Bed Room
239C
Entry
Bed Room
239A
Toilet/Shower
239B
Corridor
2C7
Bed Room
238C
Toilet/Shower
238B
Elec Clos
HAC
Toilet/Bath
232A
Clinical
Social
Worker
Clinical
Social
Worker
Clinical
Psychologist
Office
Physician
Interview
Room
Bed Room
Toilet/Shower
233A
Entry
Bed Room
233C
Bed Room
234A
Entry
Bed Room
234B
Bed Room
233B
Toilet/Shower
234C
Entry
Toilet/Shower
235C
Bed Room
235B
Bed Room
235A
Equip Room
Med Room
201A
ARS
Coordinator
Social
Worker
Detox
Coordinator
Stairs
2S3
Bed Room
206A
Toilet/Shower
206B
Bed Room
207A
Toilet/Shower
207B
Entry
Bed Room
207C
Bed Room
208A
Toilet/Shower
208B
Elec Clos
Library
HAC
Entry
Bed Room
238A
Entry
Bed Room
206C
Entry
Bed Room
208C
Corridor
2C2
Corridor
2C1
Nurse Station
Corridor
2C6
Corridor
2C5
Day Rm
Bathroom
217A
Day Room
Toilet/Shower
112A
Bed Room
112B
Bed Room
112C
Entry
Toilet/Shower
113A
Bed Room
113B
Bed Room
113C
Entry
Corridor
1C4
Bed Room
114A
Bed Room
114B
Entry
Toilet/Shower
114C
Bed Room
Toilet/Shower
115A
HAC
MHRRTP
Screener
Psychologist
Library
Bed Room
108C
Toilet/Shower
108B
Elec Clos
Bed Room
106A
Entry
Bed Room
107C
Bed Room
107A
Toilet/Shower
107B
Stairs
1BS1
Dietician
Interview
Room
Staff Work
Room
Equip Rm
Med Room
101A
Stor
120A
Linen Chute
Laundry
Room
Toilet/Shower
122A
Toilet
Nurse
Manager
Corridor
Visitor Room
Cleaning
Crash Cart
Storage
Supplies
Public
Toilet
Social
Science
Techs
Corridor
1C5
Tele Clos
Conference
Room
124A
Entry
Staff Lockers
124C
Staff Toilet
124D
Stairs
1AS1
Staff Lounge
124B
Kitchen
Associate
Chief Nurse
MHCL
Therapy Tub
/ Storage
Toilet
128A
Toilet/Shower
129A
Bed Room
Bed Room
130B
Bed Room
130C
Entry
Toilet/Shower
130A
Bed Room
131A
Bed Room
131B
Entry
Toilet/Shower
131C
Entry
Bed Room
132A
Bed Room
132B
Toilet/Shower
132C
Corridor
1C7
SUD/HCHV
Outreach
Social
Worker
HAC
Stairs
1CS1
Elec Clos
Bed Room
137A
Bed Room
139C
Toilet/Shower
139B
Toilet/Shower
137B
Entry
Bed Room
138C
Bed Room
138A
Toilet/Shower
138B
Entry
Entry
Bed Room
108A
Bed Room
106C
Entry
Bed Room
137C
Bed Room
139A
Entry
Nurse Station
Day Room
Corridor
1C3
Corridor
1C2
Corridor
1C1
Corridor
1C6
Day Rm
Corridor
1C8
Toilet/Shower
106B
Tele Clos
124E
Tele Clos
Storage
Stair
3S1
E101-24
E101-24
E101-24
KP
-2
KP
-3
KP
E-
BLE-1 BL-1
1L21
1LE2
1L22
2L21
2LE2
2L22
1L3
PANEL:
BLE-1
PANELS:
KPE-1
KP2
KP3
PANEL:
BL-1
PANEL:
1L3
PANELS:
1LE2
1L21 1L22
PANELS:
2LE2
2L21 2L22
PANEL:
2L3
2L3
Drawing Title
Reviewed for Concept Only
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of
Construction and Facilities
Management
JPA Project No.
Revision
Date
UPGRADE IT INFRASTRUCTURE
TO SUPPORT
VOIP PHONE SYSTEM
September 28, 2018
15005.00
#538-19-209
Chillicothe, Ohio
A DVANCED
E NGINEERING
C ONSULTANTS
Mechanical | Electrical | Plumbing | Fire Protection
8606 Allisonville Road, Suite 270 Tel: (317) 413-5724
Indianapolis, Indiana 46256 Fax: (614) 486-4082
BID SET
DJ AJ
E101-24
8' 16' 32'03/64"=1'-0"1
OVERALL BASEMENT FLOOR PLAN
8' 16' 32'03/64"=1'-0"2
OVERALL FIRST FLOOR PLAN
8' 16' 32'03/64"=1'-0"3
OVERALL SECOND FLOOR PLAN
N
8' 16' 32'03/64"=1'-0"4
OVERALL THIRD FLOOR PLAN
BUILDING 24
OVERALL FLOOR PLANS
AND ENLARGED PLANS -
ELECTRICAL
01/4"=1'-0" 2' 4' 8'5
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'6
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'7
ENLARGED PLAN - ELECTRICAL
N
N
N
AutoCAD SHX Text No 10708835
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
CIO
T M
G B
1 M
(O) (G)
5 7
(E)
(E) 6
BS-17
DN
UP
UP
UP
UP
DN
UP
UP UP
DN
DN
DN
UP
DN
DN
Break Room
Social
Worker
Physician
Corridor
100H
Staff Locker
Room
Staff Toilet
111A
Stair
S1-1
1 Bed Room
Toilet/
Shower
110A
1 Bed Room
HAC Stor
Corridor
100G
1 Bed Room
Nurse Station
Tub/ Laundry
Room
2 Bed Room
Storage
2 Bed Room
Storage
2 Bed Room
Storage
1 Bed Room
Linen Chute
Visitor's
Room
Staff Toilet
Exam &
Interview
SPD
Storage
Signal
Closet
Clean Linen
Signal
Closet
Telephone
Closet
Patient
Dining Room
Stair
S5-1
Patient Toilet
2 Bed Room
2 Bed Room
1 Bed Room
Storage
2 Bed Room
Storage
2 Bed Room
Storage
2 Bed Room
1 Bed Room
Ante
Room
Soiled Utility
Ante
Room
1 Bed Room
Treatment
Team Room
Treatment
Team Room
Social
Worker
Psychiatrist
Storage
Social
Worker
Psychiatrist
Social
Worker
PA Office
HAC
Elec Closet
2 Bed Room
1 Bed Room
Patient
Lounge
Toilet/
Shower
137A
Toilet/
Shower
139A
Toilet/
Shower
143A
Toilet/
Shower
147A
Toilet/
Shower
162A
Corridor
100E
Corridor
100I
Corridor
100J
Stair
S4-1
Corridor
100B
Kitchenette
Corridor
100C
Corridor
100D
Vestibule
Nurse Station
Med Carts
Nurse
Manager
1 Bed Room
1 Bed Room
Elec Closet
HAC
Corridor
100F
Toilet/
Shower
118A
Toilet/
Shower
122A
Toilet
117A
Toilet/
Shower
115A
Stair
S2-1
Med Prep
101A
Toilet/
Shower
104A
Toilet
126A
Toilet
128A
Corridor
100A
Patient
Telephones
Stair
S3-1
Storage
148A
Storage
116A
Closet
107A
Break Room
Nurse Station
Nourishment
Kitchen
Exam Room
MIT
Bed Room
Elec Closet
HAC
Storage
Bed Room
Bed Room
Bed Room
Bed Room
Linen
Storage
Congregate
Toilet
Soiled Utility
Congregate
Bath
Bed Room
Stor
Bed Room
Bed Room
Bed Room
Storage
Stair
S2-2
Linen Chute
Quiet Room
Female Toilet
Physician
Sterile
Supplies
EMS Storage
Telephone
Closet
Day Room
Break Room
Nurse
Manager
Bed Room
Stair
S3-2
Female
Shower
Bed Room
Bed Room
Bed Room
Stor
Conference
Room
Congregate
Bath
Soiled Utility
Congregate
Toilet
Bed Room
Linen Room
Bed Room
Bed Room
Bed Room
Storage
HAC
Elec Closet
Bed Room
Storage
Bed Room
Bed Room
Staff Toilet
Toilet
256A
Toilet
211A
Toilet
210A
Toilet
209A
Toilet
205A
Congregate
Shower
216A
Toilet
217A
Toilet
220A
Toilet
225A
Toilet
227A
Stair
S5-2
Stair
S4-2
Stair
S1-2
Med Prep
201A
Toilet
231A
Toilet
238A
Toilet
239A
Congregate
Shower
242A
Toilet
248A
Toilet
249A
Toilet
253A
Toilet
255A
Toilet
245A
Corridor
200J
Corridor
200I
Corridor
200E
Corridor
200A
Corridor
200B
Corridor
200D
Corridor
200K
Corridor
200F
Corridor
200C
Telephone
Closet
Elec Closet
BN P-EBN
UP
UPUP
UP
UP UP
UP
Storage
4C
Craft
4B
Recreation
Clinic
Stair
S1-0
Toilet
4A
Elec Closet
EMS Storage
EMS Storage
HAC
Linen
Stair
S2-0
Linen
Storage
EMS
Supervisor
MER
CIO
P1
Equipment
Mechanical
Room
Equipment
9A
Tele
27A
EMR
Canteen
Storage
Employee
Health
MER
Canteen
Storage
Storage
25A
Toilet
MER
Supply Room
Room
23A
EMS Office
Social Work
Service
Womens
Toilet
Mens Toilet
HAC
Employee
Health Rest
Area
18A
Storage
18B
Occupational
Safety &
Health
Manager
18C
Employee
Health Exam
18D
Employee
Health Phy
Extender
18E
Employee's
Health
Program
Support Clerk
18F
Industrial
Hygenist
18G
GEMS
Coordinator
18H
Safety
Program
Support
Specialist
18I
Stair
S3-0
Stair
S4-0
Stair
S5-0
EMS Storage
24A
Chapel
Recreation
2A
Corridor
Corridor
Room
4D
Room
200L
Room
200M
E101-26
GENERAL NOTES:
A. PANEL NAMES SHOWN FOR NEW CIRCUITS ARE SUGGESTIONS.
CONNECT NEW CIRCUITS TO LOCAL PANEL WITH AVAILABLE
BREAKER SPACE OF APPROPRIATE SIZE.
B. MECHANICAL EQUIPMENT (EXHAUST FANS AND SPLIT SYSTEMS)
ARE PROVIDED BY OWNER. E.C. SHALL MAKE FINAL ELECTRICAL
CONNECTIONS.
C. CEILING TYPES ARE NOTED IN ROOMS AND HALLWAYS WITH
SCOPE.
(G) = GRID / LAY-IN CEILING
(O) = OPEN CEILING
(GYP) = GYPSUM BOARD CEILING
CODED NOTES:
1. EXHAUST FAN: CONNECT TO 20A/1P CIRCUIT IN LOCAL PANEL.
COORDINATE LOCATION WITH OWNER PRIOR TO ROUGH-IN.
ROUTE 3/4"C, 2-#12, 1-#12G.
2. NEW RECEPTACLE. CONNECT TO LOCAL 20A/1P CIRCUIT.
3. E.C. SHALL INSTALL OWNER PROVIDED MOTOR RATED TOGGLE
SWITCH FOR EXHAUST FAN.
4. EXISTING PLYWOOD BACKBOARD TO REMAIN.
5. NEW TELECOM BUSBAR.
6. EXISTING OUTLET TO REMAIN.
7. EXISTING TELECOM RACK TO REMAIN.
E101-26
PANELS:
E2S 2S
E2S
BN
PANEL:
BN
BS
PANEL:
BS
2S
PANELS:
E2N 2N
2N E2N
Telephone
Closet
TMGB
4 5
(E)(E) E2S-17
(E)
(G) (G)
Drawing Title
Reviewed for Concept Only
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of
Construction and Facilities
Management
JPA Project No.
Revision
Date
UPGRADE IT INFRASTRUCTURE
TO SUPPORT
VOIP PHONE SYSTEM
September 28, 2018
15005.00
#538-19-209
Chillicothe, Ohio
A DVANCED
E NGINEERING
C ONSULTANTS
Mechanical | Electrical | Plumbing | Fire Protection
8606 Allisonville Road, Suite 270 Tel: (317) 413-5724
Indianapolis, Indiana 46256 Fax: (614) 486-4082
BID SET
DJ AJ
E101-26
8' 16' 32'03/64"=1'-0"1
OVERALL BASEMENT FLOOR PLAN
8' 16' 32'03/64"=1'-0"2
OVERALL FIRST FLOOR PLAN
8' 16' 32'03/64"=1'-0"3
OVERALL SECOND FLOOR PLAN
N
8' 16' 32'03/64"=1'-0"4
OVERALL THIRD FLOOR PLAN
BUILDING 26
OVERALL FLOOR PLANS
AND ENLARGED PLANS -
ELECTRICAL
01/4"=1'-0" 2' 4' 8'5
ENLARGED PLAN - ELECTRICAL
PANELS:
BN
P-EBN
N
NN
01/4"=1'-0" 2' 4' 8'6
ENLARGED PLAN - ELECTRICAL
AutoCAD SHX Text No 10708835
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
Tele Closet
T M
G B
(E)
(E)
(G)
(G)
E1B-34
M
Tele Closet
TMGB
TMGB
(E)
(G)
(O)
6 45
6(E)
Tele Closet
J
T M
G B
E1B-32
M
(E) (E)
5 46
(G)
(G)
E101-27
UP
UP
UP
UP
Mech Room
Men's Toilet
Women's
Toilet
Mech
Equipment
Chaplin
Service
Soiled Linen
Tele Closet
Elevator
Equpment
Optometry
Waiting
Corridor
Tele Closet
HAC
Mechanical
Equipment
Patient
Waiting
Employee
Lounge
Biomedical
Engineer
Elec Closet
Mech
Equipment
HAC
30A
Men
Toilet/Shower
Elec
Switchgear
Elevator
Equipment
Patient
Waiting
5A
Private
Waiting
5B
Toilet
5Ca
GYN/Triage
Room
5C
Clean
Storage
5F
Patient Toilet
5D
Soiled Utility
5E
Corridor
Procedure
5G
Conference
5H
HAC
5I
Provider
5J
Provider
5K
Exam
5L
Exam
5M
Exam
5N
Corridor
Meds
5P
Corridor
1B
Corridor
1A
Corridor
1C
Vending Area
1D
Physician
Assistant
11A
Chaplain
11B
Physician
Assistant
11D
Storage
11C
Storage
17G
Telephone
17F
MDRO
prevention
Coordinator
17E
Infection
Control
Nurse
17D
Telephone
Triage Nurse
17B
RME
Coordination
Nurse
Educator
17A
MAS
Secretary
17C
Reception
22A
Soiled
22B
EKG/Holter
22C
EKG/Holter
22D
Reading
22E
Pt
Ed/Storage
22F
Servers
22G
Editing
22H
EEG
22I
Linen
22J
ECHO
22K
Female Toilet
32B
Linen Chute
13A
Recept./Nursing
5O
Corridor
1E
Optometry
16A
16B
Stairs
000B
Stairs
000A
Closet
5Q
Stairs
000C
Corridor
1F
Closet
16C
Room
Room
Waiting
Room
Visitor Toliet
Optometry
Exam
Optometry
Exam
Optometry
Exam Room
Toilet Room
Elec Closet
HAC
Optometry
Exam
Optometry
Exam
Optometry
Staff Office
Staff Toilet
Opt Staff
Office
Opt Staff
Office
Resident/Student
Office
Optometry
Exam
Laser Room
SPD
Dialiation
Waiting
Optometry
Visual Field
Intake Nurse
POD Exam
Room
POD Exam
Room
Procedure
Room
Storage
Podiatry
Office
Optometry
Pre-Test
Optometry
Exam Room
Linen Chute
Soil Util
Retinal Exam
Tele Closet
Ice Machine
Pat Ed & Visit
Coor
Patient Toilet
Women's
Veteran
Program
Manager
Breakroom
Conference
Room
Women's
Health
Diagnostic
Coordinator
GECL
Physician's
Assistant
Centeral
Check In
140 Neurology
Soil Util
Derm
Procedure
Pulmonary
Exam Room
Pulmonary
Exam Room
Toilet Room
Ortho
Procedure
Ortho Exam
Room
Derm Exam
Room
Intake Nurse
PAPR
Storage
Location
Intake Nurse
Hematology
Procedure
GYN
Hematology
Clean Utility
GYN Exam
156A
EEG Reading
Room
Neurology
Exam Room
Clean Linen
Ortho GYN
Cardio Clinic
HAC
Elec Closet
Storage
Exam Room
UV Room
Associate
Chief Nurse
Optical Shop
Omnicell
118A
Corridor
100A
Corridor
100B
Corridor
100C
Corridor
100D
Corridor
100E
Corridor
100F
Corridor
100G
Optometry
Student Staff
Offices
100H
Corridor
100I
Corridor
100K
GYN
Department
100L
GYN Exam
156B
Toilet
156D
GYN Exam
156C
Toilet Room
153A
Med Room
150A
Closet
114A
Storage
119A
Corridor
119B
Stairs
001A
Stairs
001B
Storage
143A
Stairs
001D
Stairs
001C
Pain Clinic
Check In
Release of
Information
Pain Clinic
Waiting
Women's
Toilet
Chiropractor
Pain
Coordinator
GI Clerical
Staff Break
Room
GI Storage
Elec Closet
HAC
GI Procedure
GI Med
Room
GI Work
Room
GI Procedure
GI Wake Up
Area/Recovery
Storage
GI Work
Room
Crash Cart
GI Procedure
Clean Utility
& Storage
Medivator
Room
Soiled Utility
Decon Area
Clean Linen
Staff
Toilet/Shower
Exam Room
Exam Room
Exam Room
228 Exam Room
Physician
Office
Nursing
Office
Linen Chute
GI Clinic
Lounge
Tele Closet
EMS Storage
PBS
Kitchenette
Men's Toilet
Exam Room
Pain
Management
Storage
Conference
Room
Psychologist
Clinical
Pharmacist
Physician
Physician
Extender
Physician
Extender
Conference
RN Consult
Coordinator
Quality
Improvement
Facilitator
Physician
Extender
Physician
Extender
Men's Toilet
Women's
Toilet
Staff Break
Room
C & P
Coordinator
Program
Support
Assist
Secretary
MSCL
Storage
MSCL
Manager
Administrative
Assistant
C & P
Program
Manager
Office
Supplies/Copier
Physician
HAC
Elec Closet
MSCL
Storage
Physician
Physician
Staff
Neurologist
VISN 10
Homeless
Coordinator
Corridor
200A
Corridor
200C
Corridor
200B
Corridor
200D
Corridor
200B1
Corridor
200F
Corridor
200E
Corridor
200G
Corridor
200H
Corridor
200B2
Toilet
234A
Toilet
260A
Patient
Changing
Restroom
215A
Stairs
002C
Storage
246A
Stairs
002B
Stairs
002A
Storage
224A
Storage
221A
Room
E101-27
EBB
BB E1B
1B
E101-27
PANELS:
1B
E1BPANELS:
EBB
BB
CODED NOTES:
1. CONNECT RECEPTACLE TO LOCAL CIRCUIT SUCH THAT EACH
RECEPTACLE ON THIS WALL IS ON A DIFFERENT CIRCUIT.
2. EXHAUST FAN: CONNECT TO 20A/1P CIRCUIT IN LOCAL PANEL.
COORDINATE LOCATION WITH OWNER PRIOR TO ROUGH-IN.
ROUTE 3/4"C, 2-#12, 1-#12G.
3. E.C. SHALL INSTALL OWNER PROVIDED MOTOR RATED TOGGLE
SWITCH FOR EXHAUST FAN.
4. EXISTING PLYWOOD BACKBOARD TO REMAIN.
5. NEW TELECOM BUSBAR.
6. EXISTING OUTLET TO REMAIN.
7. EXISTING TELECOM RACK TO REMAIN.
8. EXISTING 208V/2P JUNCTION BOX.
GENERAL NOTES:
A. PANEL NAMES SHOWN FOR NEW CIRCUITS ARE SUGGESTIONS.
CONNECT NEW CIRCUITS TO LOCAL PANEL WITH AVAILABLE
BREAKER SPACE OF APPROPRIATE SIZE.
B. MECHANICAL EQUIPMENT (EXHAUST FANS AND SPLIT SYSTEMS)
ARE PROVIDED BY OWNER. E.C. SHALL MAKE FINAL ELECTRICAL
CONNECTIONS.
C. CEILING TYPES ARE NOTED IN ROOMS AND HALLWAYS WITH
SCOPE.
(G) = GRID / LAY-IN CEILING
(O) = OPEN CEILING
(GYP) = GYPSUM BOARD CEILING
Drawing Title
Reviewed for Concept Only
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of
Construction and Facilities
Management
JPA Project No.
Revision
Date
UPGRADE IT INFRASTRUCTURE
TO SUPPORT
VOIP PHONE SYSTEM
September 28, 2018
15005.00
#538-19-209
Chillicothe, Ohio
A DVANCED
E NGINEERING
C ONSULTANTS
Mechanical | Electrical | Plumbing | Fire Protection
8606 Allisonville Road, Suite 270 Tel: (317) 413-5724
Indianapolis, Indiana 46256 Fax: (614) 486-4082
BID SET
DJ AJ
E101-27
8' 16' 32'03/64"=1'-0"1
OVERALL BASEMENT FLOOR PLAN
8' 16' 32'03/64"=1'-0"2
OVERALL FIRST FLOOR PLAN
8' 16' 32'03/64"=1'-0"3
OVERALL SECOND FLOOR PLAN
N
N
N
BUILDING 27
OVERALL FLOOR PLANS
AND ENLARGED PLANS -
ELECTRICAL
01/4"=1'-0" 2' 4' 8'4
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'6
ENLARGED PLAN - ELECTRICAL
01/4"=1'-0" 2' 4' 8'5
ENLARGED PLAN - ELECTRICAL
AutoCAD SHX Text No 10708835
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
Comm Closet
Closet
201A
T M
G B
(E)
(E)
(G)
(G)
(E)
(E)
(E) (E)
LP2A-14,16
Tank Room
Ladies Toilet
Canteen
Storage
Elevator
Machine
Room
Canteen
Storage
HAC
Men Toilet
Operations
Clerk
Canteen
Chief
Vesitbule
Chief
Canteen
Storage
Canteen
Retail Store
HAC
14A
Storage
13A
Storage
13B
Elec Closet
13C
Mech
Equipment
2A
Money
Room
9A
Corridor
10A
Storage
13D
Stairs
Stairs
Elevator
Lobby
Stairs
DN
Dining
Serving Line
Kitchen
Kitchen
Freezer
Pot/Pan
Room
Storage
Dining
102A
Food Service
Super
102B
Dining
102C
Corridor
103A
Stairs
Elevator
Lobby
Stairs
Stairs
Closet
102D
Comm Closet
Canteen
Salon
CRC Office
Social
Worker
Social
Worker
Supervisor
Canteen
Storage
Women
Toilet
Social Work
Supervisor
Copy/File
Room
Waiting Area
MHICM Case
Manager
Men Toilet
Conference
MHICM Case
Manager
MHICM Case
Manager
MHCIM Case
Manager
CRC/MHICM
Program
Manager
Medical
Foster Home
Coordinator
Closet
210A
Secretary
Social Work
Service
210B
Chief, Social
Worker
Service
210C
CRC/MHICM
Program
Support
Assistant
210D
Closet
201A
Closet
202A
Closet
203A
Closet
204A
Closet
205A
Closet
205B
HAC
207A
Closet
208A
Closet
208B
Closet
209A
Closet
209B
Closet
2011A
Closet
2011B
HAC
212A
Closet
214A
Closet
215A
Closet
216A
Closet
217A
Closet
218A
Corridor
Corridor
200A
Stairs
Stairs
Elevator
Lobby
Stairs
E101-28
LP2B
PANEL:
LP2B
LP2
LP2A
PANELS:
LP2
LP2A
Drawing Title
Reviewed for Concept Only
Location
Building Number
Project Title
Checked DrawnDate
Project No.
Drawing Number
Dwg. of o n e e i g h t h i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t t h r e e i n c h e s o n e f o o t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
VA Project No.
ARCHITECT/ENGINEERS:CONSULTANTS:
Office of
Construction and Facilities
Management
JPA Project No.
Revision
Date
UPGRADE IT INFRASTRUCTURE
TO SUPPORT
VOIP PHONE SYSTEM
September 28, 2018
15005.00
#538-19-209
Chillicothe, Ohio
A DVANCED
E NGINEERING
C ONSULTANTS
Mechanical | Electrical | Plumbing | Fire Protection
8606 Allisonville Road, Suite 270 Tel: (317) 413-5724
Indianapolis, Indiana 46256 Fax: (614) 486-4082
BID SET
DJ AJ
BUILDING 28
OVERALL FLOOR PLANS
AND ENLARGED PLANS -
ELECTRICAL
E101-28
01/4"=1'-0" 2' 4' 8'4
ENLARGED PLAN - ELECTRICAL
N
N
N
4' 8' 16'03/32"=1'-0"1
OVERALL BASEMENT FLOOR PLAN
4' 8' 16'03/32"=1'-0"2
OVERALL FIRST FLOOR PLAN
4' 8' 16'03/32"=1'-0"3
OVERALL SECOND FLOOR PLAN
GENERAL NOTES:
A. CIRCUITS SHOWN ARE SUGGESTIONS, CONTRACTOR MAY
CONNECT TO A DIFFERENT PANEL. CONNECT NEW CIRCUITS
TO LOCAL PANEL WITH AVAILABLE BREAKER SPACE OF
APPROPRIATE SIZE.
B. MECHANICAL EQUIPMENT (EXHAUST FANS AND SPLIT SYSTEMS)
ARE PROVIDED BY OWNER. E.C. SHALL MAKE FINAL ELECTRICAL
CONNECTIONS.
C. CEILING TYPES ARE NOTED IN ROOMS AND HALLWAYS WITH
SCOPE.
(G) = GRID / LAY-IN CEILING
(O) = OPEN CEILING
(GYP) = GYPSUM BOARD CEILING
CODED NOTES:
1. SPLIT SYSTEM INDOOR UNIT: COORDINATE LOCATION WITH
OWNER PRIOR TO ROUGH-IN.
2. RECEPTACLE FOR SPLIT SYSTEM CONDENSATE PUMP. MOUNT
AT HEIGHT OF AND WITHIN 1' OF INDOOR UNIT. CONNECT TO
EXISTING LOCAL RECEPTACLE CIRCUIT AS INDICATED.
3. SPLIT SYSTEM OUTDOOR UNIT: COORDINATE LOCATION AND
MOUNTING HEIGHT WITH OWNER PRIOR TO ROUGH-IN.
4. E.C. SHALL PROVIDE 30A/2P, NEMA 3R FUSIBLE DISCONNECT.
5. CONNECT INDOOR AND OUTDOOR UNITS. ROUTE 3-#12, 1-#12 G
IN 3/4" C.
6. EXISTING OUTLET TO REMAIN.
7. EXISTING PLYWOOD BACKBOARD TO REMAIN.
8. PROVIDE NEW WALL MOUNTED, 4 UNIT RACK FOR EXISTING
SWITCH. EC SHALL MOUNT EXISTING SWITCH IN NEW RACK,
MODIFY EXISTING TELECOM. CABLE AS NECESSARY. RACK
SHALL BE "MIDDLE ATLANTIC" VPM-4 OR EQUAL.
9. NEW TELECOM BUSBAR.
AutoCAD SHX Text No 10708835
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
Elec Tele
Closet
8F
TMGB
EBK-6
M
EBK
EK
9 8
(E)
(E)
(G) (G)
Tele Clos
T M
G B
(E)
(G)
(G)
(E)
Tele Clos
TMGB
(E) (E)
(G) (G)
E401-30
UP
UP
UP
UP
UP
UP
UP
UP
UP
DN
UP
UP
UP
Crawl Space
Crawl Space
Crawl Space
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
PCT Program
4D
PCT Program
4E
Corridor
PCT Program
4F
PCT Program
4C
PCT Program
4B
PCT Program
4G
PCT Program
4A
Electric
Switchgear
Corridor
0B
Corridor
0E
Stair
S7-0
PTSD
VSO Office
1A
VSO Office
1C
Storage
1D
Copy Room
2B
Tele Closet
14A
Mech Equip
Rm
Elev Equip
SCI&D Nurse
13A
Elec Closet
Skin Integrity
Ostomy Care
Coordinator
13B
PT/Spinal
Cord
13C
Dieticians
Office
Decedent
Affairs
10A
Corridor
0C
Toilet
10F
HAC
10G
Stair
S6-0
Oxygen
Storage
9B
PT &
Prosthetics
Orthotic
Clinic
Soiled Linen
8B
Diabetes
Education
8C
Patient Ed
Class Rm
8D
Patient Ed
Storage
8G
Diabetic
Educator
8E
Elec Tele
Closet
8F
Unisex Toilet
8A
Corridor
Autopsy
10D
Storage
10C
Viewing
Affairs
10B
Morgue
Cooler
10E
PCT Waiting
Storage
2A
Corridor
0A
Stair
S3-0
Corridor
0D
Storage
4J
Office
8H
Hallway
10H
PT/Spinal
Chord
13E
Stair
S2-0
Stair
S4-0
Mech Equip
Rm
Canteen
Vending
0F
PT/Spinal
Cord Clinic
Room
0G
Patient Room
Patient Room
Patient Room
Patient Room
Patient Room
Patient Room
Kitchen
1…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.