About this file

This document is a Sources Sought Notice for a Request for Information (RFI) regarding a Transcranial Magnetic Stimulator, Solicitation Number 36C24W24Q0142. The Department of Veterans Affairs is seeking information on the MagPro X100 Stimulator, a high-performance magnetic stimulator primarily for research use. The desired system must include specific components such as the MagPro X100 with MagOption, coil, arm, monitor option, isolation transformer, and trolley. The stimulator is intended for diagnostic use to assess and monitor diseases of the central and peripheral nervous system, as well as therapeutic use for the treatment of major depressive disorder. Responses should include company information, small business status, socioeconomic category, authorization to distribute, and detailed product descriptions. The response deadline is July 12, 2024 at 2:00 PM Central Time. The project is for the VA San Diego Spinal Cord Injury and Community Living Center.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
MAGPRO X100 STIMULATOR / Transcranial Magnetic Stimulator Request For Information (RFI)

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
95652
SOLICITATION NUMBER*
36C24W24Q0142
RESPONSE DATE/TIME/ZONE
07-12-2024 2:00 CENTRAL TIME, CHICAGO, USA
ARCHIVE
5 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
Regional Procurement Office West (RPOW)

3237 Peacekeeper Way Building 200 Suite 204 McClellan Park CA 95652

POINT OF CONTACT*

Contract Specialist Sonja Fields sonja.fields@va.gov

PLACE OF PERFORMANCE

ADDRESS
VA San Diego Spinal Cord Injury and Community Livi

3350 La Jolla Village Drive, San Diego CA

POSTAL CODE
92161

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

RFI/Sources Sought, Brand Name or Equal To.

RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION:

- Company name and SAM.gov UEI number.

- Point of contact name, phone number, and e-mail address.

- Are you a small business manufacturer?

- Socio-economic category of your company.

- Verification if your company is an authorized distributor/reseller (Manufacturer Letter of Authorization to distribute is required. Must be dated within past 12 months).

- Detailed information/description for items you are capable and authorized to provide.

NAICS Code 339112 is applicable to determine business size standard. Any questions or concerns may be directed to Sonja Fields via e-mail at Sonja.fields@va.gov. No telephone calls, please.

Project Name: San Diego SCI/CLC Project Location:

Cat Code: VV
JSN: M8173A

Date Prepared: October 26, 2023

Brand Name or Equal Nomenclature: Transcranial Magnetic Stimulator Manufacturer: MagVenture Inc. Model Name: MagPro X100 System Dealer: Model Number: MagPro X100 Email: infousa@magventure.com 3rd Party Install: No Room Nbr(s): See Attached

Phone: 1-888-624-7764

Dimensions: D 16.00 in W 9.00 in H 8.50 in D 406.4 mm W 228.6 mm H 215.9 mm

1: Plumbing: 7: Data: No 2: Electrical: SPECIAL ELECTRICAL REQUIREMENTS 8: Drops:

DC: No EP: No Addl Outlets: Amps: Outlet Type: 9: Warranty: 2 yr 3: Medical Gas: 10: Training: Yes 4: Misc Gas: 11: Weight: 146.00 5: NonMed Gas: 12: Wall Blocking: No 6: Misc:

Salient Characteristics A high performance magnetic stimulator primarily for research. The MagPro X100 with MagOption offers a wide range of stimulation parameters, theta burst and stimulation rates up to 100 Hz, and the possibility to combine waveforms and pulse modes. With the same features as the MagPro X100, it also provides half-sine waveforms, twin and dual pulses up to 50 pps (biphasic) and has a power mode with a 40% increase in intensity and pulse width.

Diagnostic Use: The MagProX100 with MagOption is intended as an electro-physiological aid to assess diagnosis and to monitor diseases of the central and peripheral nervous system, based on the use of Motor Evoked Potentials (MEP).

Therapeutic Use: Treatment of Major Depressive Disorder in adult patients who have failed to achieve satisfactory improvement from two prior antidepressant medications, at or above the minimal effective dose and duration in the current episode.

System must consist of the following items as Basis Of Design (Meet or exceed) for effective treatment:

-P/N 9016E0731: MagPro X100 with MagOption -P/N 9016E0423: Coil MCF-B65 -P/N 9016B0171: Super Flex Arm for Coil Positioning (long) -P/N 9016C0711: MEP Monitor Option (with 1.5mm cable and pack of electrodes) -P/N 9016D0031: Isolation Transformer MagPro X/R System -P/N 9016B0712: XH Trolley for MagPro & coil holder accessories