This document includes specifications for a chain link fence and gate installation project. The project involves upgrading an outdoor 480V transformer and electrical system at a Department of Veterans Affairs medical center to feed a 480V switchgear, correct wiring deficiencies in CAT scan rooms, and move electrical feeds for several air handlers and associated chilled water pumps and controls to emergency power circuits. The specifications provide requirements for chain link fabric, fence framework, fittings, gates, accessories, finishes, and installation. Materials include hot-dipped galvanized steel for fabric, round steel pipe and rail for framework, and galvanized or polymer-coated steel and fittings. Swing gates must comply with ASTM standards and be hot-dipped galvanized or powder coated steel. Installation must follow standard practices for layout, posts, fabric, gates and meet specified clearances and structural requirements.

View the file

Other files for this federal contract opportunity

Other files attached to Upgrade 480V Electrical System, newest first.
File Type Posted
KY20210093 Wage Determination.pdf PDF
Pad-mount Med V Xforms.pdf PDF
36C24921R0084 0003.pdf PDF
36C24921R0084_1.pdf PDF
36C24921R0084 0002.pdf PDF
36C24921R0084 0001.pdf PDF
265600 Ext Lighting.pdf PDF
312011 Earthwork.pdf PDF
260526 Grounding and Bonding.pdf PDF
260533 Raceway and Boxes.pdf PDF
262413 Distribution Switchboard.pdf PDF
260513 Med Voltage Cables.pdf PDF
018113 Sustainable Construction Requirements.pdf PDF
040516 Masonry Grouting2.pdf PDF
14.10_EP101 - FIRST FLOOR ELECTRICAL PLAN.pdf PDF
14.14_EP400 - OVERALL FOURTH FLOOR PLAN.pdf PDF
14.05_EP0001 - SUB-BASEMENT ELECTRICAL PLAN.pdf PDF
14.19_EP900 - OVERALL NINTH FLOOR PLAN.pdf PDF
14.12_EP201 - SECOND FLOOR ELECTRICAL PLAN.pdf PDF
14.01_E500 - SCHEDULES, DETAILS AND SINGLE-LINE DIAGRAM.pdf PDF
260511 Req Electric.pdf PDF
033053 Cast in Place Conrete.pdf PDF
013216-15 Schedules 2.pdf PDF
013323 Shop Drawings.pdf PDF
014219 Ref Standards.pdf PDF
14.20_ES100 - ELECTRICAL SITE PLAN.pdf PDF
14.18_EP800 - OVERALL EIGHT FLOOR PLAN.pdf PDF
14.15_EP500 - OVERALL FIFTH FLOOR PLAN.pdf PDF
14.09_EP100 - OVERALL FIRST FLOOR PLAN.pdf PDF
14.17_EP700 - OVERALL SEVENTH FLOOR PLAN.pdf PDF
14.08_EP001B - BASEMENT ELECTRICAL PLAN-B.pdf PDF
14.00_E001 - LEGEND.pdf PDF
S15-PPQ-Template (Project 603-20-505) Upgrade 480V Electrical System.pdf PDF
010000 Gen Requirments Rev 2.pdf PDF
000115 List Drawing.pdf PDF
040513 Masonry Mortaring.pdf PDF
042000 Unit Masonry.pdf PDF
017419 Const Waste Management.pdf PDF
000110 TOC.pdf PDF
00.00_GI000 - COVER SHEET AND SHEET INDEX.pdf PDF
14.07_EP001A - BASEMENT ELECTRICAL PLAN-A.pdf PDF
07.00_AE101 - SCREEN WALL DETAILS.pdf PDF
14.06_EP000 - OVERALL BASEMENT ELECTRICAL PLAN.pdf PDF
14.02_E501 - PARTIAL MEDIUM VOLTAGE SINGLE-LINE DIAGRAM.pdf PDF
S02-36C24921R0084_1.pdf PDF
263623 ATS.pdf PDF
264313 Surge Prot Dev.pdf PDF
260541 Underground Elec Const.pdf PDF
262416 Panelboards.pdf PDF
S03-Successful FBO Posting-36C24921R0084 (603-20-505).pdf PDF
Show all 50

Upgrade 480V Electrical System has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Louisville KY - Robley Rex VAMC – Upgrade 480V Electrical System

Project #: 603-20-505

05-01-18

32 31 13 - 1

SECTION 32 31 13

CHAIN LINK GATES

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Chain link fence, gates and accessories.

1.2 RELATED REQUIREMENTS

A. Temporary Construction Fence: Section 01 00 00, GENERAL REQUIREMENTS.

B. Fence Color: Galvanized steel

1.3 APPLICABLE PUBLICATIONS

A. Comply with references to extent specified in this section.

B. ASTM International (ASTM):

1. A121-13 - Metallic Coated Carbon Steel Barbed Wire.

2. A392-11a - Zinc-Coated Steel Chain-Link Fence Fabric.

3. A491-11 - Aluminum Coated Steel Chain Link Fence Fabric.

4. A817-12 - Metal-Coated Steel Wire for Chain-Link Fence Fabric and

Marcelled Tension Wire.

5. B429 - Aluminum-Alloy Extruded Structural Pipe and Tube.

6. F567-14a - Installation of Chain-Link Fence.

7. F626-14 - Fence Fittings.

8. F668-11 - Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated

Steel Chain Link Fence Fabric.

9. F900-11 - Industrial and Commercial Swing Gates.

10. F1184-16 - Industrial and Commercial Horizontal Slide Gates.

11. F1664-08(2013) - Polyvinyl Chloride (PVC) and Other Conforming

Organic Polymer Coated Steel Tension Wire used with Chain Link

Fence.

12. F1665-08(2013) - Polyvinyl Chloride (PVC) and Other Conforming

Organic Polymer Coated Steel Barbed Wire used with Chain Link Fence.

13. F2200-14 - Automated Vehicular Gate Construction.

14. F1043-16 - Strength and Protective Coatings on Steel Industrial

Fence Framework.

15. F1083-16 - Pipe, Steel, Hot-Dipped Zinc-Coated (Galvanized) Welded, for Fence Structures.

C. Chain Link Fence Manufacturing Institute (CLFMI):

1. Product Manual.

05-01-18

32 31 13 - 2

D. Federal Specifications (Fed. Spec.):

1. FF-P-110J - Padlock, Changeable Combination.

E. Master Painters Institute (MPI):

1. No. 18 - Primer, Zinc Rich, Organic.

1.4 SUBMITTALS

A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

B. Submittal Drawings:

1. Show size, configuration, and fabrication and installation details.

C. Manufacturer's Literature and Data:

1. Description of each product.

2. Installation instructions.

D. Certificates: Certify products comply with specifications.

1. Fence alignment.

2. Zinc-coating.

E. Qualifications: Substantiate qualifications comply with specifications.

1. Manufacturer.

2. Installer.

1.5 QUALITY ASSURANCE

A. Manufacturer Qualifications:

1. Regularly manufactures specified products.

2. Manufactured specified products with satisfactory service on five similar installations for minimum three years.

B. Installer Qualifications:

1. Regularly installs specified products.

2. Installed specified products with satisfactory service on five similar installations for minimum three years.

C. Welders and Welding Procedures Qualifications: AWS D1.1/D1.1M. or

AWS D1.3/D1.3M.

1.6 DELIVERY

A. Deliver products in manufacturer's original sealed packaging.

B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, production run number, and manufacture date.

C. Before installation, return or dispose of products within distorted, damaged, or opened packaging.

05-01-18

32 31 13 - 3

1.7 STORAGE AND HANDLING

A. Protect products from damage during handling and construction operations.

1.8 WARRANTY

A. Construction Warranty: FAR clause 52.246-21, "Warranty of

Construction."

PART 2 - PRODUCTS

2.1 PRODUCTS - GENERAL

A. Basis of Design: Section 09 06 00, SCHEDULE FOR FINISHES.

B. Provide fences and gates from one manufacturer.

2.2 CHAIN-LINK FENCING AND GATES

A. General: Conform to CLFMI Product Manual.

B. Chain Link Fabric: 50 mm (2 inch) mesh, 3.76 mm(0.15 inches), As indicated on Drawings.

1. Zinc-Coated Steel Fabric: ASTM A392, hot dipped galvanized before or after weaving.

a. Class 1 - 366 g/sq. m (1.2 oz/sq. ft.).

b. Class 2 - 610 g/sq. m (2.0 oz/sq. ft.).

2. Fabric Selvage: K&T, Knuckle finish at one end, twist at other.

a. Fabric less than 1.8 m (72 inches) width, knuckle finish top and bottom.

C. Fence Framework:

1. Round Steel Pipe and Rail: ASTM F1043, Group IA Heavy Industrial

Fence Framework, ASTM F1083 schedule 40 galvanized pipe.

a. Line post: 60 mm (2.375 inch) diameter.

b. End, Corner, Pull post: 60 mm (2.375 inch) diameter.

c. Brace rails, top, bottom, and intermediate rails, 42 mm

(1.660 inch) diameter, 3.38 kg/m (2.27 lb./ft.).

2.3 FITTINGS

A. General: ASTM F626.

B. Tension and Brace Bands: Galvanized pressed steel.

C. Terminal Post Caps, Line Post Loop Tops, Rail and Brace Ends, Boulevard

Clamps, Rail Sleeves: Pressed steel galvanized.

D. Truss Rod Assembly: Steel truss rod with a pressed steel tightener.

05-01-18

32 31 13 - 4

E. Tension Bars: Galvanized steel one-piece length 50 mm (2 inches) less than the fabric height.

F. Polymer Coated Color Fittings: Polymer coating minimum thickness

0.15 mm (0.006 inches) fused and adhered to zinc coated fittings and match color to fence system.

2.4 TIE WIRE and HOG RINGS

A. Galvanized: Minimum zinc coating 366 g/sq. m (1.20 oz./sq. ft.);

3.76 mm (0.148 inch) diameter steel wire.

B. Polymer coated; match coating, class and color to that of the chain link fabric.

2.5 GATES

A. Swing Gates: ASTM F900 or ASTM F2200 double swing type.

1. Galvanized steel:

a. Frame: ASTM F1043 and ASTM F1083 Group IA schedule 40 pipe or

Group IC pipe 48.3 mm (1.900 inches) OD. Apply galvanized repair paint on welded joints.

b. Hardware:

1) Hinges: 180 degree gate hinges per leaf.

2) Positive locking gate latch, 7.9 mm (5/16 inches) thick by

44 mm (1 3/4 inches).

3) Padlocks: By VA.

2.6 CONCRETE

A. Concrete: As specified in Section 03 30 00, Cast-in-Place Concrete.

2.7 FINISHES

A. Steel Paint Finish:

1. Powder-Coat Finish: Manufacturer's standard two-coat finish system as follows:

a. One coat primer.

b. One coat thermosetting topcoat.

c. Dry-film Thickness: 0.05 mm (2 mils) minimum.

d. Color: Refer to Section 09 06 00, SCHEDULE FOR FINISHES.

B. Finish exposed surfaces after fabrication.

2.8 ACCESSORIES

A. Primers:

B. Barrier Coating: ASTM D1187/D1187M.

C. Welding Materials: AWS D1.1/D1.1M, type to suit application.

05-01-18

32 31 13 - 5

D. Galvanizing Repair Paint: MPI No. 18.

E. Touch-Up Paint: Match shop finish.

PART 3 - EXECUTION

3.1 PREPARATION

A. Examine and verify substrate suitability for product installation.

B. Protect existing construction and completed work from damage.

C. Apply barrier coating to steel surfaces in contact with dissimilar metals and cementitious materials to minimum 0.7 mm (30 mils) dry film thickness.

3.2 INSTALLATION

A. Layout fence and locate position of post.

B. Installation:

1. General: Comply with ASTM F567.

2. Framework:

a. Posts: Set plumb in concrete footings with 600 mm (24 inches) minimum depth.

1) Minimum Footing Diameter: Four times largest cross section of post, up to 100 mm (4 inches) O.D. and three times largest cross section of post greater than 100 mm (4 inches). O.D.

2) Provide larger footings for gate posts. Top of post concrete footing, at grade crowned to shed water away from the post.

3) Space line posts not exceeding 3 m (10 ft.) on center.

b. Top rail: Install 6.4 m (21 ft.) lengths of rail continuous thru line post or barb arm loop top. Splice rail using top rail sleeves minimum 150 mm (6 inches) long.

1) Secure rail to terminal post by brace band and rail end.

2) Field cut and secure bottom rail or intermediate rail to line posts with boulevard bands or rail ends and brace bands.

3) Provide mid rail for fences 3.7 m (12 feet) high or higher.

c. Terminal posts: Brace and truss end, corner, pull and gate posts for fence 1.8 m (6 ft.) and higher and for fences 1.5 m (5 ft.)

in height without top rail.

C. Chain Link Fabric:

1. Install fabric inside of the framework with ground clearance of

50 mm (2 inches) maximum.

2. Stretch fabric between terminal posts and secure with tension bar.

05-01-18

32 31 13 - 6

D. Gate:

1. Swing Gates: Comply with ASTM F567. Outward swing. Gates plumb in closed position with 75 mm (3 inches) bottom clearance.

E. Nuts and Bolts:

1. Bolts: Install carriage bolts with head on the secure side of the fence. Peened over all bolts shall be to prevent removal of the nut.

F. Touch up damaged factory finishes.

1. Repair galvanized surfaces with galvanized repair paint.

2. Repair painted surfaces with touch up primer.

3.3 CLEANING

A. Clean exposed fence surfaces. Remove contaminants and stains.

3.4 PROTECTION

A. Protect fence from traffic and construction operations.

B. Repair damage.

- - - E N D - - -