Serranator Characteristics.docx

DOCX document 15 KB Posted

Attached to
6515--Serranator PTA Serration Balloon Catheters
Solicitation number
36C24827Q0117
Issued by

About this file

This document specifies the minimum required features and specifications for Serranator peripheral vascular intervention catheters that the Department of Veterans Affairs, VISN 8, intends to procure through sole source award to Cagent Vascular Inc. The catheters must feature balloon-mounted serration technology to provide controlled mechanical lesion modification during peripheral angioplasty, with indicated uses for dilation of peripheral arterial lesions and treatment of obstructive lesions in native or synthetic arteriovenous dialysis fistulae. All units must be sterile, disposable, single-use devices with over-the-wire catheter design and 150 cm working length, equipped with radiopaque markers for fluoroscopic positioning and manufacturer documentation detailing balloon compliance, nominal inflation pressure, and rated burst pressure.

The procurement requires seven specific product configurations with balloon diameters ranging from 2.0 mm to 4.0 mm, lengths of either 40 mm or 120 mm, and compatibility with either 0.014-inch or 0.018-inch guidewires and 5 Fr or 6 Fr sheaths as specified. Interested parties must submit responses demonstrating interest and supporting literature to the Contracting Officer, Shirley Courtney (shirley.courtney@va.gov), no later than November 11, 2026 at 12:00 PM EST. The North American Industry Classification System (NAICS) code is 339113, and the Government reserves the right to determine whether to conduct competitive procurement based on responses received.

View the file

Other files

File Type Posted
36C24827Q0117_1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Minimum Required Features and Specifications Salient Characteristics

The requested catheters must meet the following requirements for peripheral vascular interventions.

1. Must have balloon-mounted serration that can provide controlled mechanical lesion modification during peripheral angioplasty.

2. Must be indicated for dilation of peripheral arterial lesions and treatment of obstructive lesions in native or synthetic arteriovenous dialysis fistulae.

3. Must be sterile, disposable, and intended for single use.

4. Must have an over-the-wire catheter design and a 150 cm working length.

5. Must have radiopaque markers identifying the balloon’s working length for positioning under fluoroscopy.

6. Must include manufacturer instructions, balloon compliance information, nominal inflation pressure, and rated burst pressure.

7. Must provide the size and compatibility combinations listed below.

Product reference
Balloon diameter × length
Guidewire compatibility
Sheath compatibility
FGS-0682-20040 SL-Pro
2.0 × 40 mm
0.014 inch
5 Fr
FGS-0682-20120 SL-Pro
2.0 × 120 mm
0.014 inch
5 Fr
FGS-0346-25120
2.5 × 120 mm
0.014 inch
6 Fr
FGS-0346-30040
3.0 × 40 mm
0.014 inch
6 Fr
FGS-0346-30120
3.0 × 120 mm
0.014 inch
6 Fr
FGS-0346-35040
3.5 × 40 mm
0.014 inch
6 Fr
FGS-0492-40040
4.0 × 40 mm
0.018 inch
6 Fr

File details come from the government source that posted it. Updated .