36C24825Q1022_2.docx

DOCX document 19 KB Posted

Attached to
Z2LZ--Replace Parking Lot Gates for Fisher House
Solicitation number
36C24825Q1022
Issued by

About this file

This document is an Amendment to a Combined Solicitation for replacing parking lot gates at the James A. Haley Veterans' Hospital Fisher House in Tampa, Florida. The Department of Veterans Affairs Network Contracting Office 8 is seeking a contractor to replace existing parking lot gates, which includes installing new gates, bollards, and a card reader integrated with the CCure 9000 security system. The solicitation (RFQ# 36C24825Q1022) is unrestricted and open to all qualified businesses, with a preference for Service-Disabled Veteran Owned Small Businesses (SDVOSB).

Key technical details include installing two safety yellow bollards (6-inch diameter, 5 feet tall) to protect gate pedestals, integrating a PIV card-compatible reader with 200-bit Federal Agency Smart Credential Number encryption, and routing approximately 150 feet of power and 300 feet of control panel cabling using existing pathways. The quote response is due by August 18, 2025, at 15:00 Eastern Time, with quotes to be submitted via email to the Contract Officer Walida Moore-Saintil. The solicitation uses NAICS code 812930 for Parking Lots and Garages, with a small business size standard of $47.0 Million, and requires vendors to be registered in the System for Award Management (SAM).

View the file

Other files

File Type Posted
Architectural - Bldg 53 first.pdf PDF
Magnetic parking-pro-brochure.pdf PDF
Final SOW FisherHouse Parking Gate.docx DOCX document
36C24825Q1022.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment to a Previous Combined Solicitation

Amendment to a Previous Combined Solicitation

SUBJECT*
Replace Parking Lot Gates for Fisher House

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
33637
SOLICITATION NUMBER*
36C24825Q1022
RESPONSE DATE/TIME/ZONE
08-18-2025 15:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
Z2LZ
NAICS CODE*
812930
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 8 (NCO 8)

8875 Hidden River Pkwy Suite 525 Tampa FL 33637

POINT OF CONTACT*

Contract Officer Walida Moore-Saintil Walida.MooreSaintil@va.gov 813-631-2856

PLACE OF PERFORMANCE

ADDRESS
Department of Veterans Affairs

James A. Haley Veterans' Hospital

Fisher House

13000 Bruce B. Downs Blvd.

Tampa FL

POSTAL CODE
33612
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov/plo/about/saos.asp
URL DESCRIPTION
NCO 8
AGENCY CONTACT’S EMAIL ADDRESS
Walida.MooreSaintil@va.gov
EMAIL DESCRIPTION
Walida Moore-Saintil

DESCRIPTION

VENDOR QUESTIONS & ANSWERS (Q&As) Fisher House Gates (RFQ# 36C24825Q1022) Amendment 0001

The following questions were asked of the Government relating to the subject requirement which are hereby posted and responded to.

Q&As:

1) All cabling must be included.

Question:

Answer:

a. How far away is the power source? Approximately 150 ft.

b. How far is the control panel away from the barriers? Approximately 300 ft.

c. Is there pathways available to use for new cabling or will new conduit and trenching be needed in order to pull cabling? There are pathways available. Existing wire may be used if verified working with no shorts in circuit.

d. Are there any drawings of the site for reference? Yes, I will attach a drawing to this email.

2) Bollards must be installed to protect the arms from vehicle damage.

Question:

Answer:

a. Are there any specifications for these bollards? Diameter, height, color, style, manufacturer. I don’t have any specs on the bollards. I would say equivalent to what is there. Diameter is about 6 in., height is about 5 ft., color is safety yellow, style is tough, no specific manufacturer.

b. How many are required per arm? Two bollards total. One in front of the pedestal and one behind the pedestal. They are to protect the pedestal that the card reader is on. We also need the pedestal to be replaced.

3) Card reader must be tied to CCure 9000 security system.

Question:

Answer:

a. We are not an access control company so will we be terminating to the existing system or will the access control company perform that effort? Relay and card reader wire currently exists at location. Contractor will be required to make terminations into system. Electronics will be available to identify wiring.

b. Do you have any other specifications on the type of card reader? Needs to have 200-bit Federal Agency Smart Credential Number (FASC-N) card format encryption and compatible with C-Cure. Current examples used at our facility are Wave Lynx ET20-3PS and HID pivCLASS RP40-H.

c. What type of card should the reader use? PIV card.

d. Do we need account for any cards? No.

e. Who will be responsible for programming current badges to the system? VA staff will be responsible for programming.

4) Question: Extension of due date and attached blueprint.

Answer: Quotes must be emailed to Walida.MooreSaintil@va.gov and received No Later Than Monday, August 18th, 2025, by 15:00 pm EST on the close date.

See attached document: Architectural - Bldg 53 first.

*= Required Field
Amendment to a Previous Combined Solicitation

Page 1 of

Amendment to a Previous Combined Solicitation

File details come from the government source that posted it. Updated .