36C24824R0178 BB 672-20-602 Replace Boiler 2.docx

DOCX document 24 KB Posted

Attached to
Z2DA--Replace Boiler #2 and Correct Deficiencies at Boiler Plant
Solicitation number
36C24824R0178
Issued by

About this file

This document is a Pre-Solicitation Notice for a federal contract opportunity to replace Boiler #2 and correct other deficiencies at the VA Caribbean Healthcare System (VACHS) Boiler Plant in San Juan, Puerto Rico. The proposed Solicitation Number is 36C24824R0178 and the closing response date is October 16, 2024. This requirement is set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB).

The project includes replacing the existing 350 HP Boiler #2 with a new firetube boiler that uses fuel oil #2 as the primary fuel, as well as providing a new fuel oil pump and distribution system, a new chemistry laboratory, new electrical panels, new economizers on all three boilers, and metering systems for steam, condensate, feedwater, and make-up water. The contractor will also be required to provide a temporary 350 HP boiler for the duration of the project, which has a performance period of 1,095 calendar days from the Notice to Proceed. The magnitude of construction is estimated to be between $2,000,000 to $5,000,000. The solicitation will be issued on or about September 12, 2024 and all information will be posted on the SAM.gov website. Interested SDVOSB firms must be registered in the System for Award Management (SAM.GOV) and listed in the SBA Veteran Certification site.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice Presolicitation Notice

SUBJECT*
Replace Boiler #2 and Correct Deficiencies at Boiler Plant

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
00921-3201
SOLICITATION NUMBER*
36C24824R0178
RESPONSE DATE/TIME/ZONE
10-16-2024 3:30 PM SAN JUAN, PUERTO RICO
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
Z2DA
NAICS CODE*
236220
PLACE OF PERFORMANCE
VA Caribbean Healthcare System (VACHS)

10 Calle Casia

San Juan PR

POSTAL CODE
00921-3201

COUNTRY

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 8 (NCO 8) VA Caribbean HCS (Admin Bldg) #10 Calle Casia Suite #4M440 San Juan PR 00921-3201

POINT OF CONTACT*

Senior Contracting Officer Ana G. Alvarado ana.alvarado@va.gov 939-321-0814

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Pre-Solicitation Notice Date: 08/27/2024, Subject: Replace Boiler #2 and Correct Deficiencies at Boiler Plant (Construction Services). Location: VA Caribbean Healthcare System (VACHS), San Juan, PR. Proposed Solicitation Number: 36C24824R0178. Closing Response Date: 10/16/2024. POC: Ana G. Alvarado, email: ana.alvarado@va.gov. This requirement is set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). General Description: The Department of Veteran Affairs (VA), Veterans Integrated Service Network (VISN) 8, VA Caribbean Healthcare System (VACHS) has a requirement to replace the existing boiler #2 with a new 350 HP firetube boiler and shall correct several identified deficiencies at the Boiler Plant. This new boiler shall use fuel-oil #2 as its primary fuel. The project shall also provide a new fuel oil pump and distribution system, a new chemistry laboratory, new electrical panels, new economizers on all three boilers and metering systems for steam, condensate, feedwater, and make-up water among other boiler plant improvements. Piping Tie-Ins shall be performed during weekends to minimize impact on the hospital operations. Underground fuel-oil piping shall be Glass Fiber Reinforced Plastic (FRP) with secondary containment pipe as per specification 23 10 00 and drawing MS-101. Existing dike (old day tank) lead-based paint shall be properly removed and disposed following state and federal requirements. Utility shutdowns shall be strictly coordinated with the facility, 14 days in advance, to minimize impact to daily operations. Shutdowns shall be performed during nights and weekends. Contractor shall be responsible to obtain all state and federal permits required for construction and waste disposal. The contractor shall provide a temporary boiler for the duration of the project. Boiler capacity shall be 350 HP at a minimum and use fuel oil #2 as the primary fuel. The contractor shall provide all labor, equipment, and materials for a complete temporary boiler installation. The performance period for this project is 1,095 calendar days from the issuance of a Notice to Proceed. The services for this project will include providing all construction related services such as: providing labor, materials and equipment required to complete the project as per contract documents prepared by an independent Architect-Engineer firm. The magnitude of construction is between $2,000,000 to $5,000,000. The solicitation will be issued on or about 09/12/2024. All information for this solicitation will be posted on the SAM.gov website at www.sam.gov. All interested firms must be registered in the System for Award Management (SAM.GOV). Important Notice: Prior to submitting a proposal under SDVOSB set-aside solicitation, offerors must be listed in the SBA Veteran Certification site https://veterans.certify.sba.gov/ as verified SDVOSB.

*=Required Field
Presolicitation Notice

Presolicitation Notice

File details come from the government source that posted it. Updated .