36C24824Q0567_1.docx

DOCX document 34 KB Posted

Attached to
6640--Supply: Coagulation Testing Federal contract opportunity
Solicitation number
36C24824Q0567
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

This pre-solicitation notice and related federal contract opportunity document provide details for an upcoming coagulation testing services procurement by the Department of Veterans Affairs. The VA intends to issue a request for quote seeking a contractor to provide four coagulation analyzers and associated equipment, services, and supplies to three VA medical facilities. The analyzers must be able to perform various coagulation assays and have minimum throughput capacities of 240 and 100 tests per hour. The solicitation number is 36C24824Q0567 and is anticipated to be posted on February 23, 2023 with a response due date of February 29, 2023. The procurement will provide two analyzers each to the James A. Haley VA Hospital and New Port Richey VA Outpatient Clinic, and one analyzer to the Lakeland VA Outpatient Clinic, along with printers, uninterruptible power supplies, and maintenance services. Estimated annual testing volumes and a list of required reagents and supplies for one year are also included.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice Presolicitation Notice

SUBJECT*
Supply: Coagulation Testing

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
33637
SOLICITATION NUMBER*
36C24824Q0567
RESPONSE DATE/TIME/ZONE
02-14-2024 10:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE

SET-ASIDE

PRODUCT SERVICE CODE*
6640
NAICS CODE*
334516
PLACE OF PERFORMANCE
James A. Haley Veterans Hospital

Pathology & Laboratory

13000 Bruce B. Downs, Blvd.

Tampa FL.

POSTAL CODE
33612
COUNTRY
USA

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 8 (NCO 8)

8875 Hidden River Pkwy Suite 525 Tampa FL 33637

POINT OF CONTACT*

Contract Specialist Leonora Simmons leonora.simmons@va.gov 813-972-7592

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov
URL DESCRIPTION
VA Website

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Pre-Solicitation This is a Pre-Solicitation for commercial items prepared in accordance with the format in Subpart 12.6 as supplemented with additional information included in this notice. THIS PRE-SOLICITATION NOTICE IS NOT A REQUEST FOR A QUOTE (RFQ). VENDORS SHOULD NOT SUBMIT FORMAL QUOTES UNTIL THE RFQ IS POSTED ON THIS WEBSITE. This notice is not to be construed as a commitment by the Government nor will the Government pay for the information resulting from this posting.

The Department of Veterans Affairs (VA), Veterans Integrated Service Network (VISN 8), James A. Haley Veterans’ Hospital (JAHVH), Tampa, FL, intends to issue a Request for Quote (RFQ), brand name or equal to WerFen instrumentation Laboratory ACL TOPs), including service & maintenance, supplies/consumables included in the price of reagents. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 334516-Analytical Laboratory Instrument Manufacturing with 1000 employees.

See below specifications: Brand name or equal.

EQUIPMENT:

The Contractor shall provide four (4) name brand (Instrumentation Laboratory ACL TOPSs) or equivalent Coagulation analyzers that FDA-approved, fully automated, and integrated analyzer testing systems, printers, computers, uninterruptable power supplies (UPS) for all analyzers, and accessories required for equipment usage.

Below are the salient characteristics of the FDA-approved, fully automated, and integrated analyzer testing systems, printers, computers, uninterruptable power supplies (UPS) for all analyzers, and accessories required for equipment usage. The proposal shall provide descriptive literature that meets the following specifications for the testing systems and assay requirements:

General instrument characteristics include the ability to run FDA-approved patient testing for PT, PTT, INR, Fibrinogen, D-dimer, Lupus Panel, Heparin anti-Xa (generic for all types of heparin), HIT, and Ristocetin, Factor Assays and special coagulation testing to including but not limited to mixing studies.

•Coagulation Analyzers: (Locations: JAHVH, JAH New Port Richey VA Outpatient Clinic, and JAH Lakeland VA Outpatient Clinic).

•General instrument characteristics include continuous operation including continuous sample and reagent loading without interruption of testing in progress.

•Instrument systems include integrated data management system, external printer, and UPS.

•All systems must utilize the same operating system and user interface.

•Instruments must offer extensive test menus capable of performing assays for screening, monitoring, and diagnosis of bleeding and thrombotic risks.

•Instruments must have STAT processing capabilities without disrupting other testing in progress.

•Instrument must include integrated sample and reagent barcode readers capable of reading multiple barcode symbologies.

•Instrument should be capable of performing preanalytical testing to detect tube-fill height issues, flag abnormal sample aspiration due to the presence of clots, as well as detecting interference for hemolysis, lipemia, and bilirubin.

•Data management capability for the purpose of checking QC, calibration, and other quality control options.

•Physical Characteristics include NTE 350 pounds and 60” x 32” x 30”. Must be free standing or include instrument cart.

•Electrical Characteristics - 120 V.

NAME BRAND: WerFen (Instrumentation Laboratory ACL TOPs) OR EQUIVALENT Functionality and Performance Specifications:

•The systems (delete should ) be barcode driven, random access, with continuous loading and unloading of samples, reagents, and consumables.

•The systems (delete should ) be flexible, with a minimum throughput of 240 tests per hour for the JAHVH site and 100 tests per hour at other sites.

•The systems (delete should )provide clotting, chromogenic, and turbidimetric testing capabilities to run a complete menu of routine and specialty coagulation assays including, but not limited to, Antithrombin, Protein C & S, Plasminogen, von Willebrand assays, Lupus Anticoagulant assays, Factor V Leiden screening, Heparin Xa, D-Dimer, HIT, and Factor Assays.

•Application Specialists shall (delete must )must be available for implementing and validating new assays, determining Ex Vivi heparin response curves, and providing statistical analysis for reagent lot correlations.

•The systems shall (delete should ) utilize barcoded reagent tracking consisting of material name, lot number, expiration date, and on-board stability and volume.

•Cap piercing capabilities; Safety features to avoid unnecessary exposure to biohazardous and chemical material.

•Reagents and controls shall (delete must ) have extended stability times. Minimum stability of 7 days for PT, APTT reagents, and minimum stability of 24 hours for routine controls is required.

•The systems shall (delete must ) have repeat and reflex testing capabilities based on user-defined criteria.

•The systems shall (delete should) have a floor drain-compatible waste system.

•The systems must have a quality control program with configurable multi-rules to evaluate the validity and accuracy of testing.

•The Contractor shall provide peer comparison review and evaluation of quality control statistics.

•The systems shall (delete must )have auto-programmable QC based on time, number of tests, and reagent changes.

•The systems shall (delete must ) have clot curves to help troubleshoot abnormal, spurious, and unexpected results, identify factor inhibitors, and provide additional clinical information for patient assessments.

•The systems shall only require minimal maintenance with online maintenance and quality control corrective action.

•The systems must be LIS compatible with a bi-directional or host query interface.

•Instrument-Analyzer software must be able to interface with VA-approved middleware software.

•The systems must improve the overall productivity and efficiency of the Coagulation laboratory. The systems should be 100% walkaway and not require monitoring during the testing process.

•Patient Mean Analysis Quality Control program: Required to have a QC program available on instruments or through middleware to monitor shifts and trends of test methods. Prefer company to have the ability to “see” instruments electronically for troubleshooting instrument and quality control problems.

•Comprehensive on-board QC Program, including Troubleshooting or System Validation QC material. The system must have quality control data storage able to store up to 30 separate QC files at the hospital level with a minimum storage capacity of 6 months of QC files, two lot # of calibration for anti-10a, d-dimer and fibrinogen, and reporting capabilities, the ability to view and print daily and monthly QC results, view and print Levy Jennings graphs, visually alert the operator of QC failures and to document out of range QC. Prefer the ability to submit QC data electronically to the company for peer review and to be able to put in electronic comments to document troubleshooting or review of QC data. The routine quality control should be stable on board the analyzer for up to 24 hours with the ability to program the system to auto-execute QC runs.

DELIVERABLES:

Two (2) coagulation analyzers to include lease/service/maintenance, qty., 12 MO AH NPR VA Outpatient Clinic - One (1) Coagulation Analyzer to include lease/service/maintenance.

JAH Lakeland VA Outpatient Clinic - One (1) Coagulation Analyzer to include lease/service/maintenance.

Printers, one for each testing site.

Uninterruptible power supply (UPS), one for each testing site.

ESTIMATED ANNUAL CPRR TESTING VOLUMES:

FacilityInstrumentsEst qty/year: PTaPTT
JAH VA Hospital (JAHVH), 2 Coagulation Analyzers44,00028,000
JAH NPR VA Outpatient Clinic, 1 Coagulation Analyzer5,0001,000

JAH Lakeland VA Outpatient Clinic, 1 Coagulation Analyzer 5,000 1,000

Estimated Annual CPT Testing Volumes:

ESTIMATED REAGENTS AND SUPPLIES (One Year Estimated Volumes)

Item #
Stock #
Description/Part Number*
Qty
Unit
1
00020302400
HemosIL Rinse solution 4L
578.000
EA
2
00009757600
HemosIL Factor Diluent
143.000
EA
3
00009831700
HemosIL Cleaning Solution (Clean A)
275.000
EA
4
00029401100
CUVETTE WASTE LINER 10 PK, ACL TOP
1.000
EA
5
00027344900
CONTAINER, WASTE, 10 PACK
1.000
EA
6
00020013900
HemosIL Normal Control 1
96.000
EA
7
00020014100
HemosIL Abnormal Control 3
96.000
EA
8
00029403501
CTS FILTER
3.000
EA
9
00020003050
HemosIL RecombiPlasTin 2G (20mL)
100.000
EA
10
00020006800
HemosIL SynthASil
75.000
EA
11
00009832700
HemosIL Cleaning Agent (Clean B)
315.000
EA
12
00029400100
CUVETTES, ACL TOP, 6X100X4
120.000
EA
13
00020012500
HemosIL LA Positive Control
4.000
EA
14
00020012600
HemosIL LA Negative Control
4.000
EA
15
00020301500
HemosIL dRVVT Screen
5.000
EA
16
00020301600
HemosIL dRVVT Confirm
5.000
EA
17
00020004800
HemosIL Silica Clotting Time
10.000
EA
18
00020302602
HemosIL Liquid Anti-Xa
10.000
EA
19
00022550030
HEMOSIL D-DIMER HS 500 CONTROLS
26.000
EA
20
00020301800
HemosIL Q.F.A Thrombin (Bovine, 2mL)
12.000
EA
21
00020500100
HemosIL D-Dimer HS 500
70.000
EA
22
00020004200
HemosIL Low Fibrinogen Control
37.000
EA
23
00020300200
HemosIL LMW Heparin Controls
6.000
EA
24
00020300300
HemosIL UF Heparin Controls
60.000
EA
25
00020300600
HemosIL Heparin Calibrators
2.000
EA
26
00020003700
HemosIL Calibration plasma
2.000
EA

The actual Solicitation #36C24824Q0567 is anticipated to be posted to the Beta.SAM.gov website on or about 02/23/2023, closing date of 02/29/2023 @10am EST. Quoters should continue to monitor Beta.SAM.gov for the RFQ and any subsequent Amendments to that RFQ. All Quoters must be registered in the System for Award Management (SAM) database; see https://www.sam.gov for complete online Reps and Certs. SDVOSBs must be certified and verified in VetBiz.

The point of contact is Leonora Simmons, Contract Specialist, email: leonora.simmons@va.gov