This document contains information for a federal contract opportunity with the Department of Veterans Affairs to upgrade interior signage and wayfinding at the Main Hospital building 1 of the Veterans Health Administration Veterans Integrated Service Network 8. The solicitation number is 36C24823R0115 and is a pre-solicitation notice for a project to develop program requirements for wayfinding, identify points of interest, develop messaging for new and existing signage, demo old signage, and manufacture and install new signage. This is a 100% set-aside for Service Disabled Veteran Owned Small Businesses. Interested parties should review the attached statement of work for more detailed project and response information.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

30% SCHEMATIC

DESIGN

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DISCIPLINE:

FARNSWORTH GROUP

223 WILLOW STREET

FORT COLLINS, CO 80524

970-484-7477

FIRM CONTACT: JULIE SASS

EMAIL: JSASS@F-W.COM

UPGRADE INTERIOR SIGNAGE

AND WAYFINDING

548-23-105

WEST PALM BEACH, FLORIDA

JDP01/13/2023

A u to d e s k D o c s /V

C I W e s t P a lm

B e a c h F a c ili ty /A

V

C I

W e s t

P a lm B e a c h W a y fi n d in g

.0

R

V T

.r v t

/1

/2

:3

:4

A

M

G-001

COVER

JP

DRAWING LIST

ARCHITECTURAL

G-001 COVER

ARCHITECTURAL

A-100 OVERALL PLAN - BASEMENT FLOOR

A-100-A.1 PARTIAL BASEMENT FLOOR PLAN AREA A - NORTH

A-100-A.2 PARTIAL BASEMENT FLOOR PLAN AREA A - SOUTH

A-100-B.1 PARTIAL BASEMENT FLOOR PLAN AREA B - NORTH

A-100-B.2 PARTIAL BASEMENT FLOOR PLAN AREA B - SOUTH

A-100-B.2.1 PARTIAL BASEMENT FLOOR PLAN AREA B - SOUTH SCHEDULE

A-100-C.1 PARTIAL BASEMENT FLOOR PLAN AREA C - NORTH

A-100-C.2 PARTIAL BASEMENT FLOOR PLAN AREA C - SOUTH

A-100-C.2.1 PARTIAL BASEMENT FLOOR PLAN AREA C - SOUTH SCHEDULE

A-100-D PARTIAL BASEMENT FLOOR PLAN AREA D

A-100-E PARTIAL BASEMENT FLOOR PLAN AREA E

A-101 OVERALL PLAN - 1ST FLOOR

A-101-A.1 PARTIAL 1ST FLOOR PLAN AREA A - NORTH

A-101-A.1.1 PARTIAL 1ST FLOOR PLAN AREA A - NORTH SCHEDULE

A-101-A.2 PARTIAL 1ST FLOOR PLAN AREA A - SOUTH

A-101-B.1 PARTIAL 1ST FLOOR PLAN AREA B - NORTH

A-101-B.2 PARTIAL 1ST FLOOR PLAN AREA B - SOUTH

A-101-B.2.1 PARTIAL 1ST FLOOR PLAN AREA B - SOUTH SCHEDULE

A-101-C.1 PARTIAL 1ST FLOOR PLAN AREA C - NORTH & AREA G

A-101-C.1.1 PARTIAL 1ST FLOOR PLAN AREA C - NORTH & AREA G SCHEDULE

A-101-C.2 PARTIAL 1ST FLOOR PLAN AREA C - SOUTH

A-101-C.2.1 PARTIAL 1ST FLOOR PLAN AREA C - SOUTH SCHEDULE

A-102 OVERALL PLAN - 2ND FLOOR

A-102-A.1 PARTIAL 2ND FLOOR PLAN AREA A - NORTH

A-102-A.2 PARTIAL 2ND FLOOR PLAN AREA A - SOUTH

A-102-A.2.1 PARTIAL 2ND FLOOR PLAN AREA A - SOUTH SCHEDULE

A-102-B.1 PARTIAL 2ND FLOOR PLAN AREA B - NORTH

A-102-B.2 PARTIAL 2ND FLOOR PLAN AREA B - SOUTH

A-102-B.2.1 PARTIAL 2ND FLOOR PLAN AREA B - SOUTH SCHEDULE

A-102-C.1 PARTIAL 2ND FLOOR PLAN AREA C - NORTH

A-102-C.2 PARTIAL 2ND FLOOR PLAN AREA C - SOUTH

A-102-C.2.1 PARTIAL 2ND FLOOR PLAN AREA C - SOUTH SCHEDULE

A-103 OVERALL PLAN - 3RD FLOOR

A-103-A PARTIAL 3RD FLOOR PLAN AREA A

A-103-A.1 PARTIAL 3RD FLOOR PLAN AREA A SCHEDULE

A-103-B PARTIAL 3RD FLOOR PLAN AREA B

A-103-B.1 PARTIAL 3RD FLOOR PLAN AREA B SCHEDULE

A-103-C PARTIAL 3RD FLOOR PLAN AREA C

A-103-C.1 PARTIAL 3RD FLOOR PLAN AREA C SCHEDULE

A-104 OVERALL PLAN - 4TH FLOOR

A-104-A PARTIAL 4TH FLOOR PLAN AREA A

A-104-A.1 PARTIAL 4TH FLOOR PLAN AREA A SCHEDULE

A-104-B PARTIAL 4TH FLOOR PLAN AREA B

A-104-B.1 PARTIAL 4TH FLOOR PLAN AREA B SCHEDULE

A-104-C PARTIAL 4TH FLOOR PLAN AREA C

A-104-C.1 PARTIAL 4TH FLOOR PLAN AREA C SCHEDULE

A-105 OVERALL PLAN - 5TH FLOOR

A-105-A PARTIAL 5TH FLOOR PLAN AREA A

A-105-A.1 PARTIAL 5TH FLOOR PLAN AREA A SCHEDULE

A-105-B PARTIAL 5TH FLOOR PLAN AREA B

A-105-B.1 PARTIAL 5TH FLOOR PLAN AREA B SCHEDULE

A-105-C PARTIAL 5TH FLOOR PLAN AREA C

A-106 OVERALL PLAN - 6TH FLOOR

A-106-A PARTIAL 6TH FLOOR PLAN AREA A

A-106-A.1 PARTIAL 6TH FLOOR PLAN AREA A SCHEDULE

A-106-B PARTIAL 6TH FLOOR PLAN AREA B

A-107 OVERALL PLAN - 7TH FLOOR

A-107-A PARTIAL 7TH FLOOR PLAN AREA A

A-107-B PARTIAL 7TH FLOOR PLAN AREA B

A-107-B.1 PARTIAL 7TH FLOOR PLAN AREA B SCHEDULE

A-108 OVERALL PLAN - 8TH FLOOR

A-108-A PARTIAL 8TH FLOOR PLAN AREA A

A-108-A.1 PARTIAL 8TH FLOOR PLAN AREA A SCHEDULE

A-108-B PARTIAL 8TH FLOOR PLAN AREA B

A-108-B.1 PARTIAL 8TH FLOOR PLAN AREA B SCHEDULE

A-109 OVERALL PLAN - 9TH FLOOR

A-109-A PARTIAL 9TH FLOOR PLAN AREA A

A-109-B PARTIAL 9TH FLOOR PLAN AREA B

A-109-B.1 PARTIAL 9TH FLOOR PLAN AREA B SCHEDULE

A-601 SIGNAGE PRODUCT SCHEDULE

A-602 MANDATORY VA POLICY SIGNS ELEVATIONS AND DETAILS

A-603 CODE AND LIFE SAFETY SIGNS ELEVATIONS AND DETAILS

A-604 INTERIOR SIGNS ELEVATIONS AND DETAILS

A-605 INTERIOR SIGNS ELEVATIONS AND DETAILS

SITE

WEST PALM BEACH VETERANS AFFAIRS

HEALTH CARE SYSTEM -

WAYFINDING AND INTERIOR SIGNAGE

PROJECT INFORMATION

OWNER / DEVELOPER

ARCHITECT

ELECTRICAL

MECHANICAL / PLUMBING

DEPARTMENT OF VETERANS AFFAIRS

ARCHITECT

FARNSWORTH GROUP

223 WILLOW STREET

FORT COLLINS, COLORADO

PHONE: (970) 484-7477

CONTACT: JULIE SASS

EMAIL: JSASS@F-W.COM

1. REFER TO LIFE SAFETY SHEETS FOR LIFE SAFETY INFORMATION.

2. PROJECTS SHALL REMAIN IN COMPLIANCE WITH ALL ASPECTS OF ALL GOVERNING

CODES AND ORDINANCES DURING THE COURSE OF CONSTRUCTION INCLUDING, BUT

NOT LIMITED TO, EXITING, FIRE ALARM SYSTEM(S) SMOKE/FIRE DETECTION

SYSTEM(S), SPRINKLER SYSTEM(S).

3. ALL AREAS TO BE DEMOLISHED OR DISTURBED BY ANY PRODUCT REPLACEMENT

ARE TO BE PATCHED AND PAINTED (OR PREPARED FOR OTHER SCHEDULED FINISH).

IF PAINTING IS REQUIRED, ENTIRE WALL SHALL RECEIVE PAINT TO AVOID MISMATCH

OF COLOR.

4. AT CONSTRUCTION ACCESS, CONTRACTOR TO PROVIDE LABOR AND MATERIALS TO

REPAIR ALL DISTURBED ELEMENTS.

5. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO PROVIDE COMPLETE WORKING

SYSTEMS FOR ALL NEW ELEMENTS AND TO COORDINATE THEIR WORK WITH ALL

OTHER TRADES.

6. STORE MATERIALS IN SUCH A MANNER AS NOT TO OVERSTRESS, OVERLOAD, OR

OTHERWISE PUT AN UNSAFE LOAD ON ANY STRUCTURE DURING CONSTRUCTION.

7. INSTALL ALL WORK IN ACCORDANCE WITH CURRENT APPLICABLE CODES,

PUBLISHED STANDARDS, AND ACCEPTABLE CONSTRUCTION STANDARDS.

8. DETAILS ARE GENERALLY TYPICAL AND ARE NOT TO BE CONSTRUED AS LIMITED TO

THOSE AREAS SPECIFICALLY INDICATED. REVIEW ANY QUESTIONS OR CONFLICTING

INFORMATION WITH THE DESIGN PROFESSIONAL PRIOR TO FABRICATION OR

INSTALLATION.

9. CONTRACTOR SHALL VERIFY DIMENSIONS IN FIELD PRIOR TO BEGINNING

CONSTRUCTION.

10. ALL CONTRACTORS SHALL PROVIDE NEW, UNDAMAGED MATERIALS UNLESS

OTHERWISE SPECIFIED.

11. EACH CONTRACTOR SHALL COORDINATE THEIR WORK WITH ALL OTHER TRADES.

12. DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONS. IF A REQUIRED DIMENSION

IS NOT INDICATED, CONTACT THE ARCHITECT FOR DETERMINATION.

13. EXISTING CONDITION INFORMATION SHOWN WITHIN THE PROJECT AREA IS BASED

ON FIELD OBSERVATION AND EXISTING DRAWING DOCUMENTATION. ALL EXISTING

CONDITION INFORMATION SHOWN OUTSIDE THE PROJECT AREA IS PROVIDED FOR

REFERENCE ONLY AND HAS NOT BEEN FIELD VERIFIED. CONTRACTOR IS

RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS PRIOR TO BEGINNING ANY

NEW WORK AND SHALL BRING AND DISCREPANCIES TO THE ATTENTION OF THE

ARCHITECT/ENGINEER PRIOR TO DEMOLITION AND CONSTRUCTION.

14. REFER TO GENERAL INFORMATION SHEETS FOR SYMBOLS AND ABBREVIATIONS.

15. STORAGE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS IS UNDERSTOOD TO NOT

BE WITHIN THE BUILDING. STORAGE OF ANY MATERIAL IS TO BE IN COMPLIANCE

WITH ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION.

GENERAL NOTESPROJECT LOCATION DRAWING LIST

Revisions: Date:

PHARMACY SERVICE

S-1

S-2

S-3

S-4

S-5

LIFT 1

LIFT 2

LIFT 3

P - 1

P - 2

P - 3 P - 4

P - 5

P - 6

S-9

BB -123

CONFERENCE

ROOM

BB-121

BB-125

BB-121BB-111

BB-116

BB-118

BB-C1

BB-239

BB-253

BB-115BB-104BB-102

BB-113

BB-111

BB-111

BB-112BB-111

BB-251

BB-C1

BB-C1

BB-C1

BB-213

BB-212

BB-212A

BB-C1

BB-212BBB-215

BB-237

BB-217A

BB-217

BB-251

BB-251

BB-255

TELECOMM

BB-263

BB-257

BB-251

BB-252

BB-241

BC-247

BB-248

BB-245

BB-243A

BB-249

BB-254

BB-251

BB-251 BB-259

BB-258

BB-256

BB-338

BB-336

BB-334BB-332

BB-C3

BB-324A

BB-235

BB-219B

BB-219

BB-C2

OFFICE

BB-219A

BB-233

BB-251

BB-232

BB-234

BB-251

BB-236 BB-238

BB-242

BB-241

BB-243

BB-225BB-223BB-221ABB-221

BB-322

BB-C3

BB-324

BB-312

BB-314

BB-312ABB-307

BB-316BB-309

CHIEF

CORR.CORR.

CORR.

MEAT REFRIGERATOR

FREEZER

DRUG

INFOR

SERVICE

CONTROL

SUBSTANCE

DISPENSING

FOOD PROCESSING/

PREPARATION

FOOD SERVICE

COORDINATION

CENTER

STAFF

TOILET

ELEV.

HAC

S-9 MACH.

RM.

LIFT 6

MACH. RM.

STAIR

# 1

LIFT

VESTIBULE

ELEV.

ELEV.

ELEV.

PUBLIC

ELEV

LOBBY

ELEV.

ELEV.

ELEV.

ELEC.

CLOS

TELE

SWITCH

CREDIT UNION

TELLER

AUTO

VALET

ALCOVE

UNIFORM ROOM

CREDIT

UNION

OFFICE

POISON

CONTROL

RECEIVING

CRT

CORR.

CORR.

SUPERVISOR, TECH,

AND CLERKS

CHIEF

LOGISTICS

CORR.

NOURISHMENT

PREPARATION

COOK

FOREMAN

CART

WASH

WARE WASHING

VEST.

ASSISTANT

CHIEF

CORR.

CORR.

N & FS

SUPERVISOR

ADMIN

OFFICER

NUTRITION

& FOOD

SERVICE CHIEF

CAN WASH N & FS TRAINING

MATERIAL

MANAGEMENT

SEAMSTRESS

ELEV.

ELEV.

ELEV.

MECHANICAL

CLEAN

SERVICE

LOBBY

ELEV.

ELEV.

CORR.ELEC.

HACTELE.

CORR.

MACHINE

REPAIR

SHOP

STAIR

# 15

STAIR

# 14

STAIR

#13

DOCK #4

PEST

CONTRO-

LLER

VEST IBULE

CLEANING

EQUIPMENT

ROOM

FOOD

STORAGE

BLAST

CHILLER

CART STORAGE

HAC

SANITARY

SUPPLY

CORR.

DAIRY COOLER

GENERAL COOLER

CORR.

POT WASHING

CORR.

NON-FOOD

STORAGE

PROGRAM

SUPPORT

BATTERY

CHARGE

STAIR

# 6

N O T E

ELECTRICAL

SHOP

COMPUTER

ROOM

SWITCH BOARD

COMPUTER

ROOM

TOOLS

SHOP

SUPER

CARPENTARY

SHOP

WORKROOM

ELEC.

CLOS.

TELE.

UPS

ROOM

EQUIP

TECH.

WORK

BIOMEDICAL

ENGINEERING

BREAK RM

STORAGE

MECHANICAL

BC-314B

TELE.

BC-316

ELECT.

BC-324

MECHANICAL

BC-314A

BIOMEDICAL

ENGINEERING

BC-312

LIFT 8

FUTURE

LIFT 7

CLEAN

SERVICE

LOBBY

ELEV.

S-6

ELEV.

S-7

ELEV.

S-8

STAIR

# 8

CORR.

BB -C4

LAPTOP

SUPPORT

BC - 304

EMS SUPPLY

BC - 302

CORR.

BB-C3

CORR.

BC-C3

ELEVATOR LOBBY

BC- C3

BC- 202A

BC- 218

BC - 261

BC - 202

BIOMEDICAL

ENGINEER

BC - 212

BC-203 A

ADMIN

OFF./

SEC'Y

BC - 203

STAFF

TLT.

BC - 261 A

PHARMACY

ADMIN.

BB - 121

VEST.

BC - C1

STAIR

# 7

VEST.

BC - C1

MALE

LOCKERS

BC - 101

CORR.

BC - C1

FEMALE

TOILET

BC - 103 A

MALE

TLT.

BC - 101 A

FEMALE

LOCKER

BC - 103

WORKBENCH

ELECTRONIC SHOP

BC - 211

BC - 213

BC - 213 A

BC - 213 B

BC-211A

BC - 242

BC - 202(B)

BC - 216

BC - 214

BIO.MED.

REPAIR AND

DEVELOPMENT

BC- 215

BC- 215 A

BC- 231D BC- 231E

TRANSPORTATION

BC - 322

FEMALE

TOILET

BC - 334

LOCKSMITH

SHOP

BC - 336

T/S

BC- 240A

ELEC.

CLOSET

BC- 240

SIGN SHOP

BC - 338

MALE

TOILET

BC - 340 VESTIBULE

BC - C3

DOCK

# 6

STOR.

BC - 360 B

WORKBENCH

BC - 360 A

STORAGE

BC - 360

BC - 352

EMS

SUPER.

BC - 351

CHIEF

EMS

BC - 354

AO

EMS

BC - 356

EMS

ASST. CHIEF

BC - 358

PSA

EMS

BC - 257

EOC

BC - 255

BC - 264

INTERIOR

DESIGN

BC - 253

SAFETY

SUPERVISOR

BC - 239

HAC

BC - 251

SAFETY OFFICE

BC - 250

CORR.

BC - C3

COMPUTER

TRAINING

BC - 248

SAFETY OFFICE

BC - 247

RECREATION

THERAPY

BC - 262

BC - 245

BC - 246

VOLUNTEER

RECRUITMENT

BC - 244

BC - 243

REFRIG.

BC -241 B

FREEZER

BC -241 A

SUPPLIES/

VOL.

SERVICE

BC-260

OUTDOOR

RECREATION

STORAGE

BC -261

COMP.

TRAINING

BC -263

CORR.

BC - C6

CORR.

BC - C4

FREEZER

BC -241

CORR.

BC - C6

CORR.

BC - C4

ELEV.

P - 7

FUTURE

ELEVATOR

LOBBY

BC- C1

ELEV.

P - 8

ELEV.

P - 9

ELEV.

P - 10

SUPV I.T.

SPEC.

BC - 115

I.T.

BC - 111

I.R.M.S.

TELE.

BC - 111

INFORMATION

SECURITY

OFFICER

BC - 112

CORR.

BC - C1

CORR.

BC - C3

CORR.

CB -44

STAIR

# 9

CORR.

BC - C2

OPERATIONS STORAGE

N2 MANIFOLD

N2O MANIFOLD

FIRE PUMP RM.

STAIR

# 22

STAIR

# 23

MECHANICAL

AIR COMPRESSOR

& VACUUM PUMPS

BD - 120

BE - 104

DOMESTIC

WATER

PUMP RM.

BE - 103

MECHANICAL

BD - 123

BE - 123

BOILER ROOM

BE - 121

CONF/TRAINING

ROOM

BE - 116

CONTROL

ROOM

BE - 111

OFFICE

BE - 113

LOCKERS

BE - 114

LOCKERS

BE - 112

M TLT

BE - 112A

F TLT

BE - 114A

GENERATOR RM.

BE - 142

FPL

SWITCH

ROOM

BE - 144

ELECTRICAL

SWITCH GEAR ROOM

BE - 141

CHILLER ROOM

BE - 102

A/C SHOP

BE - 131

BE - 136

BE - 134

BE - 132

CORR.

BE - 110

MECHANICAL

BD-102

LIQUID

SUPPLY

SYSTEM

BD-102

ELECT

BD-108

HAC

BD-106

STORAGE

BD-104

CART WASHER

AREA

BD-101

RECEIVING

BD-101

PROCESSING

AREA

BD-101

SORTING & WASHING AREA

BD-101

FOREMAN

BD-119

BD-119

TEXTILE

CARE

BD-119B

ASS'T

MNGR

BD-119A

REST & LUNCH AREA

BD-117

HAC

BD-111

MEN'S

LOCKER

BD-113

WOMEN'S

LOCKER

BD-115

ASSEMBLY

DISTRIBUTION

BD-101

CORR.

BD-C1

CORRIDOR

BD-117

CORRIDOR

BD-C1

CORR.

CORR.

BD-C1

CORR.

BD-101

VEST.

BD-113 BD-115

CORR.

BD-101

LINEN

HOLED

BD-101

LOADING

DOCKS #7

DOCK 7

LOADING

DOCK 8

SEAMSTRESS

PEST

CONTRO-

LLER

EMERGENCY

DOOR

ADMIN.

SUPP.

ASSIST.

MECH. ROOM

BD-101A

LAUNDRY

STORAGE

ASSOC.

CHIEF

BB - 122

CHIEF

INFO.

OFFICE

BC-111A

CHIEF

VOL. REC

THERAPY

PAINT

SHOP

BC - 342

COMPUTER

TRAINING

RECREATION

THERAPY

BC - 245A

ASST. CHIEF

REC THERAPY

VOLUNTARY

SERVICE

MECH.

CLOSET

BE - 314

EMS

REPAIR

AREA BC-318

BIOMEDICAL

ENGINEERING

WELDING

DEPT.

LOW

WALL

OFFICE

BC - 114B

STORAGE

BC - 114A

IRMS

STOR.

ELEC

CLOSET

BC-114D

BC - 114 IRMS (IT)

(MEZZANINE ABOVE)

(MEZZANINE ABOVE)

(MEZZANINE ABOVE)

OFFICE

BE -111A

STORAGE BAY 1

STORAGE BAY 2STORAGE BAY 3STORAGE BAY 4STORAGE BAY 5

MEZZANINE STORAGE BAYS 4 & 5

FACILITY

MANAGEMENT

SERVICE

(LANDING)

FENCED AREA

OFFICE OFFICE

OFFICE OFFICE

MEZZANINE STORAGE BAY 3 MEZZANINE STORAGE BAY 1

MEZZANINE STORAGE BAY 2

SEE PLANS FOR

NURSING HOME

CARE UNIT

GENERATOR CONTROL

BE - 150

MEZZANINE ABOVE

MEDICAL

GAS ROOM

DOMESTIC

WATER ROOM

BC- 231

BC- 231CBC- 231B

BC- 231A

BC - 266

FACILITY

PLANNER

OFFICE

HAC

BA-229

SPS

LOANER

DELIVERY

BA-232

FEMALE

LOCKERS

BA-234

MALE

LOCKERS

BA-233

MALE

TOILET

BA-233A

FEMALE

TOILET

BA-234A

MALE

LOCKERS

BA-235

MALE

TOILET

BA-235A

CLEAN

RECEIVING &

BREAKOUT

BA-241

ANTE/

GOWNING

RM.

BA-242

FEMALE

TOILET

BA-243A

FEMALE

LOCKERS

BA-243

HAC

BA-249

SPS

ASSISTANT

CHIEF

BA-245

QA

SPECIALIST

BA-244

SPS

ASSISTANT

CHIEF

BA-246

SPS CHIEF

BA-252

LOGISTICS

OFFICE

BA-254

LOGISTICS

OFFICE

BA-254A

PIV

COORD.

BA-261B

PROPERTY

MANAGEMENT

BA-212

LOGISTICS

PROPERTY

MANAGEMENT

BA-208

ASST

CHIEF

HIMS

BA-118

CHIEF

AMBULATORY

CARE

BA-120

ASST.

CHIEF

AMBULATORY

CARE

BA-107

ASST.

CHIEF

MAS

BA-105

VTP

MANAGER

BA-121

BENEFICIAL

TRAVEL

BA-101

PHARM

SUPERVISOR

BB - 121A

ELEC

CLOSET

BG-130

CORRIDOR

BG - 126

PREP RM

BG - 113

PREP RM

BG - 112

PREP RM

BG - 111

EXIT CORRIDOR

BG - 110

WAITING

ROOM

BG - 109

CLEAN

UTIL.

BG - 115

PATIENT

TOILET

BG - 114

CHIEF

TECH.

BG - 117

CORRIDOR

BG - 107

HOLD

ROOM

BG - 118

HOLD

ROOM

BG - 119

READING

ROOM

BG - 120

MRI

CONTROL

ROOM

BG - 121

MRI

SCANNING

ROOM

BG - 122

MRI

SCANNING

ROOM

BG - 123

RECOVERY

AND

SCREENING

BG - 128

LINEN

ALCOVE

BG - 127

HAC

BG - 129

MRI

SYSTEM

COMPONENT

ROOM

BG - 106

CHIEF

HIMS

BA-119

DOCK

LIFT

RECEIVING AND

SHIPPING DOCK

DOCK 1

STAIR 11

DOCK

LEVELER

DOCK

LEVELER

ARCH

ABOVE

OFFICE

STORE-

KEEPER

BA-210

ROLL-UP

DOOR SIZE

10'-0"WX10'-0"H

STORAGE

BA-206

STAFF

TLT.

BA-204

BA-202

DIALYSIS

STORAGE

HAC

SPACE

BA-203

MECHANICAL

BA-302

MED GAS

BA-303

MED GAS

UNPOSTED STOCK

HOLDING AREA

WAREHOUSE

RECEIVING

BA-201

RECEIVING AND

ISSUE AREA

SUBSISTENCE

STORAGE

WAREHOUSE

STORAGE

BA-201

MEDICAL/

GENERAL

STORAGE

STAIR 3

MAIL ROOM

BA-215A

BIOMED

WORKSTATION

BA-201A

DOCK 2

ANTE-

ROOM

BA-304

REFRIGERATED

BODY

HOLDING

BA-304A

LAB/PATH

BA-310

EMS STORAGE

BA-312

CORR.

BA-C4

MECHANICAL

BB-304

CHIEF

LOGISTIC

BB-306

STAIR 5

SOILED

SERVICE

LOBBY

BB-302

PNEUMATIC

TUBE

FAN ROOM

BB-302A

CORR.

BA-C3

VEST.

BA-271

FEMALE

LOCKERS

BA-271

VEST.

BA-271

FEMALE

TOILETS

SHOWERS

BA-271A

VEST.

BA-272

MALE

LOCKERS

BA-272

MALE TLTS.

SHOWERS

BA-272A

VEST.

BA-272

BA-261A

CORR.

BA-C1

BA-108

MATERIAL

MANAGEMENT

BA-106

PROGRAM

COORDINATOR

BA-106A

HIMS/MAS

BA-104

CONSOLE ROOM

BB-206

OPERATIONS

ROOM BB-204

EVIDENCE

STORAGE

BB-204A

SECURITY

ROOM

BB-202

CORR.

BB-201STORAGE

BB-209

MANAGEMENT

BA-106B

MAS

ADMIN

SUPERV

BA-103

OFFICE

BB-207

OFFICE

BB-205 INTERVIEW

BB-203

OFFICE

BA-109

BA-102

SUPPLY/EQUIP.

STORAGE

BA-251

MACHINE

BA-110

TELEPHONE

SWITCHGEAR

BA-112

ELECT

ROOM

BA-114

E.T.O. CYLINDER

STORAGE

BA-223

PREPARATION

ASSEMBLY

BA-251A

ETO

VESTIBULE

BA-223

AUTO

CART

WASH

BA-225

MANUAL

EQUP.

WASH

BA-227

CORR.

BA-221

DECONTAMINATION

ROOM

BA-221

MACH.

ROOM

BA-215B

CORR.

BA-C3

CORR.

BA-C2

AUTO

CART

DRYING

CANTEEN RECEIVING

CORR.

TRASH

CHUTE

ABOVE

PIV

OPERATIONS

BA-261

MEDICAL

RESEARCH

STORAGE

LLTS

CORR.

CB-7

V.P.

DN

CORR.

RECEIVING

HAC

WAITING

SERVICE

OFFICE

BA-261C

MATERIAL

STAIR #2

STAIR 4

ETO

VESTIBULE

BA-223

BA-308

BA-95 BA-97 BA-99

MAIL ROOM

ADMIN

OFFICER

BA-115

ADMIN

OFFICER

BA-116

SUPERVISOR

BA-117

HOLDING

BB-203

BA-301

ADMINISTRATIVE

REFRIG.

BIOMED

EQUIP.

STORAGE

(NO ROOM

LABEL OR

SIGNAGE)

CONF.

WAITING

RECEPTION

BREAK ROOM

BA-263

BA-1024

LOGISTICS

BA-215

ELEV.

MACH.

EMS

STORAGE

BA-306

VESTIBULE

BA-312A

MAS

ADMIN. OFFICES/CUBICLES

CONFERENCE

BA-111

STERILE/

NON-STERILE

STORAGE

AREA

BB-C1

CORR.

BB-111A

STORAGE

STORAGE BAY 5

IV

COMPOUND

BB-117

IV

COMPOUND

ANTE-ROOM

BB-120

CHEMO

COMPOUND

ANTE-ROOM

BB-119

CHEMO

COMPOUND

BB-121

IV &

CHEMO

PREP

SUPV I.T.

SPEC.

BC - 113

BC- 231F

OFFICE

BC- 231G

BE - 104

BC-114C

K-4386ANGLESEY C_TOILETS VITREOUS CHINA

K-3544HIGHLINE C_TOILETS VITREOUS CHINA

K-3544HIG

HLINE

C_TO

ILETS

VITREO

US CHINA

K-3544HIGHLINE C_TOILETS VITREOUS CHINA

K-3544HIGHLINE C_TOILETS VITREOUS CHINA

T RA VE L DI ST AN CE

I NF O RM ATI O N

T1

T3

T2

T5

T4

T6

T8

T7

T9

T10

T11

T12

T13

D1

D2

D3

D4

X2

X1

X3

TO TAL TR AVEL D ISTAN C E TO EXIT = 198'- 0" < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 174'- 1" < 200 FT.

TR AVEL IN SU ITE TO EXIT AC C ESS = 67'- 5" < 100 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 124'- 0" < 200 FT.

TR AVEL IN SU ITE TO EXIT AC C ESS = 98'- 9" < 100 FT.

TR AVEL IN SU ITE TO EXIT ACC ESS = 98'- 10" < 100 FT.

TO TAL TR AVEL D ISTAN CE TO EXIT = 89'- 5" + X2 < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 168'- 9" < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 147'- 4" < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 171'- 0" < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 116'- 10" < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 164'- 9" < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 153'- 4" < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 164'- 5" < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 157'- 3" < 200 FT.

TO TAL TR AVEL D ISTAN C E TO EXIT = 98'- 10" < 200 FT.

D EAD EN D CO R RIDO R = 32'- 9" < 50 FT.

D EAD EN D CO R RIDO R = 22'- 0" < 50 FT.

D EAD EN D CO R RIDO R = 41'- 5" < 50 FT.

D EAD EN D CO R RIDO R = 22'- 8" < 50 FT.

1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.

2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.

SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED

IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.

3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER

MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA

STANDARDS ON NEAREST ADJACENT WALL.

4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH

STAKEHOLDERS PRIOR TO ORDER AND INSTALL.

5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES

AND VARIATIONS OF SIGN TYPES.

SHADING DENOTES AREAS NOT IN CONTRACT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

30% SCHEMATIC

DESIGN

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DISCIPLINE:

FARNSWORTH GROUP

223 WILLOW STREET

FORT COLLINS, CO 80524

970-484-7477

FIRM CONTACT: JULIE SASS

EMAIL: JSASS@F-W.COM

UPGRADE INTERIOR SIGNAGE

AND WAYFINDING

548-23-105

WEST PALM BEACH, FLORIDA

JDP01/13/2023

A u to d e s k D o c s /V

C I W e s t P a lm

B e a c h F a c ili ty /A

V

C I

W e s t

P a lm B e a c h W a y fi n d in g

.0

R

V T

.r v t

/1

/2

:3

:5

A

M

A-100

OVERALL PLAN - BASEMENT

FLOOR

GENERAL SHEET NOTES

N O

R T H

TRUE

NORTH

PLAN

P - 1

P - 2

P - 3 P - 4

P - 5

P - 6

BB-C1

BB-C2

ELEV.

ELEV.

ELEV.

PUBLIC

ELEV

LOBBY

ELEV.

ELEV.

ELEV.

CORR.

EMERGENCY

DOOR

ASST

CHIEF

HIMS

BA-118

CHIEF

AMBULATORY

CARE

BA-120

ASST.

CHIEF

AMBULATORY

CARE

BA-107

ASST.

CHIEF

MAS

BA-105

VTP

MANAGER

BA-121

BENEFICIAL

TRAVEL

BA-101

CHIEF

HIMS

BA-119

DIALYSIS

STORAGE

SPACE

BA-203

SUBSISTENCE

STORAGE

WAREHOUSE

STORAGE

BA-201

MEDICAL/

GENERAL

STORAGE

STAIR 3

VEST.

BA-272

CORR.

BA-C1

BA-108

MATERIAL

MANAGEMENT

BA-106

PROGRAM

COORDINATOR

BA-106A

HIMS/MAS

BA-104

CONSOLE ROOM

BB-206

OPERATIONS

ROOM BB-204

EVIDENCE

STORAGE

BB-204A

SECURITY

ROOM

BB-202

CORR.

BB-201STORAGE

BB-209

MANAGEMENT

BA-106B

MAS

ADMIN

SUPERV

BA-103

OFFICE

BB-207

OFFICE

BB-205 INTERVIEW

BB-203

OFFICE

BA-109

BA-102

SUPPLY/EQUIP.

STORAGE

BA-251

MACHINE

BA-110

TELEPHONE

SWITCHGEAR

BA-112

ELECT

ROOM

BA-114

E.T.O. CYLINDER

STORAGE

BA-223

PREPARATION

ASSEMBLY

BA-251A

ETO

VESTIBULE

BA-223

AUTO

CART

WASH

BA-225

MANUAL

EQUP.

WASH

BA-227

AUTO

CART

DRYING

MEDICAL

RESEARCH

STORAGE

MATERIAL

STAIR #2

ETO

VESTIBULE

BA-223

BA-95 BA-97 BA-99

ADMIN

OFFICER

BA-115

ADMIN

OFFICER

BA-116

SUPERVISOR

BA-117

HOLDING

BB-203

ADMINISTRATIVE

BA-1024

LOGISTICS

MAS

ADMIN. OFFICES/CUBICLES

CONFERENCE

BA-111

STERILE/

NON-STERILE

STORAGE

AREA

TRAVEL DISTANCE

INFORMATION

T1

T3

T2

T5

T4

T6

T8

T7

T9

T10

T11

T12

T13

D1

D2

D3

D4

X2

X1

X3

T O TAL T R AVEL D ISTAN C E TO EXI T = 198 '- 0" < 200 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 174 '- 1" < 200 FT.

T R AVEL IN SU ITE T O EXIT A C C ESS = 67'- 5" < 100 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 124 '- 0" < 200 FT.

T R AVEL IN SU ITE T O EXIT A C C ESS = 98'- 9" < 100 FT.

T R AVEL I N SU ITE TO EXI T AC C ES S = 98' - 10" < 100 FT.

T O TAL TR AVEL D IS TAN C E T O EXIT = 89'- 5" + X2 < 200 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 168 '- 9" < 200 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 147 '- 4" < 200 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 171 '- 0" < 200 FT.

T O TAL T R AVEL D ISTAN C E TO EXIT = 116'- 1 0" < 2 00 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 164 '- 9" < 200 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 153 '- 4" < 200 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 164 '- 5" < 200 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 157 '- 3" < 200 FT.

T O TAL T R AVEL D ISTAN C E TO EXI T = 98' - 10" < 200 FT.

D EAD EN D C O R R ID O R = 32'- 9" < 50 FT.

D EAD EN D C O R R ID O R = 22'- 0" < 50 FT.

D EAD EN D C O R R ID O R = 41'- 5" < 50 FT.

D EAD EN D C O R R ID O R = 22'- 8" < 50 FT.

1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.

2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.

SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED

IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.

3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER

MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA

STANDARDS ON NEAREST ADJACENT WALL.

4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH

STAKEHOLDERS PRIOR TO ORDER AND INSTALL.

5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES

AND VARIATIONS OF SIGN TYPES.

SHADING DENOTES AREAS NOT IN CONTRACT

DOOR PERM. OPEN

IN-04.03

IN-04.03

IN-04.03IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03 IN-04.03

IN-01.10

IN-04.03IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-01.15-.24

IN-04.03

IN-04.03

IN-04.03

IN-15

IN-01.01.01

IN-01.31

IN-01.31

IN-01.15-.24

IN-01.31

IN-01.15-.24

IN-01.31

IN-15

IN-04.03

IN-01.15-.24

IN-04.03

IN-01.15-.24

IN-01.26-.30

IN-01.26-.30

IN-01.11

IN-08.02

IN-01.01.01

IN-15

IN-02.08

IN-15

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

30% SCHEMATIC

DESIGN

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DISCIPLINE:

FARNSWORTH GROUP

223 WILLOW STREET

FORT COLLINS, CO 80524

970-484-7477

FIRM CONTACT: JULIE SASS

EMAIL: JSASS@F-W.COM

UPGRADE INTERIOR SIGNAGE

AND WAYFINDING

548-23-105

WEST PALM BEACH, FLORIDA

JDP01/13/2023

A u to d e s k D o c s /V

C I W e s t P a lm

B e a c h F a c ili ty /A

V

C I

W e s t

P a lm B e a c h W a y fi n d in g

.0

R

V T

.r v t

/1

/2

:3

:5

A

M

A-100-A.1

PARTIAL BASEMENT FLOOR PLAN

AREA A - NORTH

GENERAL SHEET NOTES

0 4 8 16 KEY PLAN

SCALE: NOT TO SCALE

D E

A

A B

B

C

C

SIGNAGE - BASEMENT AREA A - NORTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION Count

BASEMENT NORTH A BA-101 IN-04.03 - 1

BASEMENT NORTH A BA-101 IN-04.03 - 1

BASEMENT NORTH A BA-102 IN-01.15-.24 NEAR STAIR 2 1

BASEMENT NORTH A BA-102 IN-01.31 NEAR BA-109 1

BASEMENT NORTH A BA-102 IN-01.31 NEAR STAIR 2 1

BASEMENT NORTH A BA-103 IN-04.03 - 1

BASEMENT NORTH A BA-105 IN-04.03 - 1

BASEMENT NORTH A BA-106A IN-04.03 - 1

BASEMENT NORTH A BA-106B IN-04.03 - 1

BASEMENT NORTH A BA-107 IN-04.03 - 1

BASEMENT NORTH A BA-109 IN-04.03 - 1

BASEMENT NORTH A BA-110 IN-04.03 - 1

BASEMENT NORTH A BA-111 IN-04.03 - 1

BASEMENT NORTH A BA-112 IN-04.03 - 1

BASEMENT NORTH A BA-114 IN-04.03 - 1

BASEMENT NORTH A BA-115 IN-04.03 - 1

BASEMENT NORTH A BA-116 IN-04.03 - 1

BASEMENT NORTH A BA-117 IN-04.03 - 1

BASEMENT NORTH A BA-118 IN-04.03 - 1

BASEMENT NORTH A BA-119 IN-04.03 - 1

BASEMENT NORTH A BA-120 IN-04.03 - 1

BASEMENT NORTH A BA-121 IN-04.03 - 1

BASEMENT NORTH A BA-201 IN-01.01.01 - 1

BASEMENT NORTH A BA-201 IN-01.15-.24 - 1

SIGNAGE - BASEMENT AREA A - NORTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION Count

BASEMENT NORTH A BA-201 IN-01.31 NEAR BA-203 1

BASEMENT NORTH A BA-201 IN-01.31 - 1

BASEMENT NORTH A BA-203 IN-04.03 - 1

BASEMENT NORTH A BA-223 IN-04.03 - 1

BASEMENT NORTH A BA-223 IN-04.03 - 1

BASEMENT NORTH A BA-251A IN-15 - 1

BASEMENT NORTH A BA-1024 IN-01.15-.24 - 1

BASEMENT NORTH A BB-203 IN-04.03 - 1

BASEMENT NORTH A BB-205 IN-04.03 - 1

BASEMENT NORTH A BB-207 IN-04.03 - 1

BASEMENT NORTH A BB-209 IN-04.03 - 1

BASEMENT NORTH A CORR. BB-201 IN-01.15-.24 - 1

BASEMENT NORTH A CORR. BB-201 IN-08.02 - 1

BASEMENT NORTH A CORR. BB-C1 IN-01.01.01 NEAR BA-101 1

BASEMENT NORTH A CORR. BB-C1 IN-02.08 NEAR BA-101 1

BASEMENT NORTH A CORR. BB-C1 IN-15 NEAR BA-101 1

BASEMENT NORTH A CORR. BB-C1 IN-15 NEAR BA-101 1

BASEMENT NORTH A CORR. BB-C1 IN-15 NEAR BA-101 1

BASEMENT NORTH A STAIR 2 IN-01.10 - 1

BASEMENT NORTH A STAIR 2 IN-01.11 - 1

BASEMENT NORTH A STAIR 2 IN-01.15-.24 - 1

BASEMENT NORTH A STAIR 2 IN-01.26-.30 - 1

BASEMENT NORTH A STAIR 2 IN-01.26-.30 - 1

GRAND TOTAL: 47

N O

R T H

TRUE

NORTH

BB-C2

CORR.

HAC

BA-229

SPS

LOANER

DELIVERY

BA-232

FEMALE

LOCKERS

BA-234

MALE

LOCKERS

BA-233

MALE

TOILET

BA-233A

FEMALE

TOILET

BA-234A

MALE

LOCKERS

BA-235

MALE

TOILET

BA-235A

CLEAN

RECEIVING &

BREAKOUT

BA-241

ANTE/

GOWNING

RM.

BA-242

FEMALE

TOILET

BA-243A

FEMALE

LOCKERS

BA-243

HAC

BA-249

SPS

ASSISTANT

CHIEF

BA-245

QA

SPECIALIST

BA-244

SPS

ASSISTANT

CHIEF

BA-246

SPS CHIEF

BA-252

LOGISTICS

OFFICE

BA-254

LOGISTICS

OFFICE

BA-254A

PIV

COORD.

BA-261B

PROPERTY

MANAGEMENT

BA-212

LOGISTICS

PROPERTY

MANAGEMENT

BA-208

DOCK

LIFT

RECEIVING AND

SHIPPING DOCK

DOCK 1

STAIR 11

DOCK

LEVELER

DOCK

LEVELER

ARCH

ABOVE

OFFICE

STORE-

KEEPER

BA-210

ROLL-UP

DOOR SIZE

10'-0"WX10'-0"H

STORAGE

BA-206

STAFF

TLT.

BA-204

BA-202

DIALYSIS

STORAGE

HAC

MECHANICAL

BA-302

MED GAS

BA-303

MED GAS

UNPOSTED STOCK

HOLDING AREA

WAREHOUSE

RECEIVING

BA-201

RECEIVING AND

ISSUE AREA

SUBSISTENCE

STORAGE

MAIL ROOM

BA-215A

BIOMED

WORKSTATION

BA-201A

DOCK 2

ANTE-

ROOM

BA-304

REFRIGERATED

BODY

HOLDING

BA-304A

LAB/PATH

BA-310

EMS STORAGE

BA-312

CORR.

BA-C4

MECHANICAL

BB-304

PNEUMATIC

TUBE

FAN ROOM

BB-302A

CORR.

BA-C3

VEST.

BA-271

FEMALE

LOCKERS

BA-271

VEST.

BA-271

FEMALE

TOILETS

SHOWERS

BA-271A

VEST.

BA-272

MALE

LOCKERS

BA-272

MALE TLTS.

SHOWERS

BA-272A

VEST.

BA-272

BA-261A

CORR.

BA-C1

BA-108

MATERIAL

MANAGEMENT

BA-106

PROGRAM

COORDINATOR

BA-106A

HIMS/MAS

BA-104

CONSOLE ROOM

BB-206

OPERATIONS

ROOM BB-204

EVIDENCE

STORAGE

BB-204A

SECURITY

ROOM

MANAGEMENT

PREPARATION

ASSEMBLY

BA-251A

ETO

VESTIBULE

BA-223

AUTO

CART

WASH

BA-225

MANUAL

EQUP.

WASH

BA-227

CORR.

BA-221

DECONTAMINATION

ROOM

BA-221

MACH.

ROOM

BA-215B

CORR.

BA-C3

CORR.

BA-C2

AUTO

CART

DRYING

CANTEEN RECEIVING

TRASH

CHUTE

ABOVE

PIV

OPERATIONS

BA-261

MEDICAL

RESEARCH

STORAGE

LLTS

CORR.

CB-7

V.P.

DN

OFFICE

BA-261C

STAIR 4

ETO

BA-308

MAIL ROOM

BA-301

BREAK ROOM

BA-263BA-215

EMS

STORAGE

BA-306

VESTIBULE

BA-312A

STERILE/

NON-STERILE

STORAGE

AREA

K-3544HIGHLINE C_TOILETS VITREOUS CHINA

K-3544HIG

HLINE

C_TO

ILETS

VITREO

US CHINA

K-3544HIGHLINE C_TOILETS VITREOUS CHINA

K-3544

HIGHLINE C_TOILETS VITREOUS CHINA

1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.

2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.

SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED

IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.

3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER

MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA

STANDARDS ON NEAREST ADJACENT WALL.

4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH

STAKEHOLDERS PRIOR TO ORDER AND INSTALL.

5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES

AND VARIATIONS OF SIGN TYPES.

SHADING DENOTES AREAS NOT IN CONTRACT

304A ON SIGN

IN-04.03

IN-04.03

IN-02.04

IN-01.10 IN-04.03

IN-04.03

IN-04.03IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-09.01

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-09.01

IN-04.03

IN-09.01

IN-01.15-.24

IN-04.03

IN-15

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03IN-04.03

IN-15

IN-04.03IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-15

IN-04.03

IN-01.01.01

IN-01.01.01

IN-04.03

IN-01.15-.24IN-04.03

IN-15 IN-15

IN-04.03

IN-01.31

IN-04.03IN-04.03

IN-01.15-.24 IN-01.15-.24

IN-01.15-.24 IN-01.15-.24

IN-04.03 IN-01.31

IN-01.15-.24

IN-04.03

IN-09.01

IN-01.26-.30

IN-01.15-.24

IN-09.01

IN-04.03

IN-04.03 IN-04.03

IN-04.03

IN-15

IN-15

IN-01.15-.24

IN-15

IN-01.31

IN-04.03

IN-01.15-.24

IN-01.15-.24

IN-01.15-.24

IN-01.26-.30

IN-02.10

IN-02.08

IN-09.01

IN-09.01

IN-15

IN-01.26-.30

IN-01.26-.30

IN-01.26-.30

IN-01.11

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

30% SCHEMATIC

DESIGN

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DISCIPLINE:

FARNSWORTH GROUP

223 WILLOW STREET

FORT COLLINS, CO 80524

970-484-7477

FIRM CONTACT: JULIE SASS

EMAIL: JSASS@F-W.COM

UPGRADE INTERIOR SIGNAGE

AND WAYFINDING

548-23-105

WEST PALM BEACH, FLORIDA

JDP01/13/2023

A u to d e s k D o c s /V

C I W e s t P a lm

B e a c h F a c ili ty /A

V

C I

W e s t

P a lm B e a c h W a y fi n d in g

.0

R

V T

.r v t

/1

/2

:3

:0

A

M

A-100-A.2

PARTIAL BASEMENT FLOOR PLAN

AREA A - SOUTH

GENERAL SHEET NOTESSIGNAGE - BASEMENT AREA A - SOUTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION Count

BASEMENT SOUTH A BA-10 IN-04.03 - 1

BASEMENT SOUTH A BA-104 IN-01.15-.24 - 1

BASEMENT SOUTH A BA-104 IN-04.03 - 1

BASEMENT SOUTH A BA-106 IN-04.03 - 1

BASEMENT SOUTH A BA-201 IN-01.01.01 - 1

BASEMENT SOUTH A BA-201 IN-01.31 - 1

BASEMENT SOUTH A BA-201A IN-01.01.01 - 1

BASEMENT SOUTH A BA-201A IN-01.15-.24 - 1

BASEMENT SOUTH A BA-201A IN-01.15-.24 - 1

BASEMENT SOUTH A BA-201A IN-01.15-.24 - 1

BASEMENT SOUTH A BA-201A IN-01.15-.24 - 1

BASEMENT SOUTH A BA-201A IN-02.04 - 1

BASEMENT SOUTH A BA-201A IN-04.03 - 1

BASEMENT SOUTH A BA-201A IN-04.03 - 1

BASEMENT SOUTH A BA-202 IN-04.03 - 1

BASEMENT SOUTH A BA-204 IN-09.01 - 1

BASEMENT SOUTH A BA-206 IN-04.03 - 1

BASEMENT SOUTH A BA-208 IN-04.03 - 1

BASEMENT SOUTH A BA-210 IN-04.03 - 1

BASEMENT SOUTH A BA-212 IN-04.03 - 1

BASEMENT SOUTH A BA-215A IN-04.03 - 1

BASEMENT SOUTH A BA-215B IN-04.03 - 1

BASEMENT SOUTH A BA-221 IN-01.15-.24 - 1

KEY PLAN

SCALE: NOT TO SCALE

D E

A

A B

B

C

C

SIGNAGE - BASEMENT AREA A - SOUTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION Count

BASEMENT SOUTH A BA-221 IN-01.26-.30 NEAR BA-229 1

BASEMENT SOUTH A BA-221 IN-04.03 - 1

BASEMENT SOUTH A BA-223 IN-04.03 - 1

BASEMENT SOUTH A BA-225 IN-04.03 - 1

BASEMENT SOUTH A BA-227 IN-04.03 - 1

BASEMENT SOUTH A BA-229 IN-01.15-.24 - 1

BASEMENT SOUTH A BA-232 IN-04.03 - 1

BASEMENT SOUTH A BA-233 IN-04.03 - 1

BASEMENT SOUTH A BA-233A IN-09.01 - 1

BASEMENT SOUTH A BA-234 IN-04.03 - 1

BASEMENT SOUTH A BA-234A IN-09.01 - 1

BASEMENT SOUTH A BA-235 IN-04.03 - 1

BASEMENT SOUTH A BA-235A IN-09.01 - 1

BASEMENT SOUTH A BA-242 IN-04.03 - 1

BASEMENT SOUTH A BA-243 IN-04.03 - 1

BASEMENT SOUTH A BA-243A IN-09.01 - 1

BASEMENT SOUTH A BA-246 IN-04.03 - 1

BASEMENT SOUTH A BA-251 IN-01.15-.24 - 1

BASEMENT SOUTH A BA-251 IN-04.03 - 1

BASEMENT SOUTH A BA-252 IN-04.03 - 1

BASEMENT SOUTH A BA-254 IN-04.03 - 1

BASEMENT SOUTH A BA-254A IN-01.15-.24 - 1

BASEMENT SOUTH A BA-254A IN-01.15-.24 - 1

SIGNAGE - BASEMENT AREA A - SOUTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION Count

BASEMENT SOUTH A BA-254A IN-04.03 - 1

BASEMENT SOUTH A BA-261 IN-01.15-.24 - 1

BASEMENT SOUTH A BA-261 IN-04.03 - 1

BASEMENT SOUTH A BA-261B IN-04.03 - 1

BASEMENT SOUTH A BA-261C IN-04.03 - 1

BASEMENT SOUTH A BA-263 IN-04.03 - 1

BASEMENT SOUTH A BA-271A IN-09.01 - 1

BASEMENT SOUTH A BA-272 IN-04.03 - 1

BASEMENT SOUTH A BA-272A IN-09.01 - 1

BASEMENT SOUTH A BA-302 IN-04.03 - 1

BASEMENT SOUTH A BA-304 IN-01.15-.24 - 1

BASEMENT SOUTH A BA-304 IN-04.03 - 1

BASEMENT SOUTH A BA-304A IN-04.03 - 1

BASEMENT SOUTH A BA-306 IN-04.03 - 1

BASEMENT SOUTH A BA-308 IN-04.03 - 1

BASEMENT SOUTH A BA-308 IN-04.03 - 1

BASEMENT SOUTH A BA-310 IN-04.03 - 1

BASEMENT SOUTH A BA-312 IN-04.03 - 1

BASEMENT SOUTH A BA-312A IN-04.03 - 1

BASEMENT SOUTH A BC-261A IN-04.03 - 1

BASEMENT SOUTH A CORR. BA-C1 IN-15 NEAR BA-106 1

BASEMENT SOUTH A CORR. BA-C1 IN-15 NEAR BA-272 1

BASEMENT SOUTH A CORR. BA-C2 IN-01.31 NEAR BA-251 1

SIGNAGE - BASEMENT AREA A - SOUTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION Count

BASEMENT SOUTH A CORR. BA-C2 IN-15 NEAR BA-261 1

BASEMENT SOUTH A CORR. BA-C3 IN-01.31 NEAR STAIR 4 1

BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR BA-241 1

BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR CORR.

BA-C2 V.P.

BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR CORR.

BA-C2 V.P.

BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR BA-263 1

BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR BA-312A 1

BASEMENT SOUTH A CORR. BA-C4 IN-01.26-.30 - 1

BASEMENT SOUTH A CORR. BA-C4 IN-02.08 - 1

BASEMENT SOUTH A CORR. BA-C4 IN-02.10 - 1

BASEMENT SOUTH A CORR. BA-C4 IN-15 NEAR CORR.

BA-C3

BASEMENT SOUTH A STAIR 4 IN-01.10 - 1

BASEMENT SOUTH A STAIR 4 IN-01.11 - 1

BASEMENT SOUTH A STAIR 4 IN-01.26-.30 - 1

BASEMENT SOUTH A STAIR 4 IN-01.26-.30 - 1

BASEMENT SOUTH A STAIR 4 IN-01.26-.30 - 1

GRAND TOTAL: 85

0 4 8 16 N O

R T H

TRUE

NORTH

PHARMACY SERVICE

P - 4

P - 5

P - 6

S-9

BB -123

CONFERENCE

ROOM

BB-121

BB-125

BB-121BB-111

BB-116

BB-118

BB-C1

BB-239

BB-253

BB-115BB-104BB-102

BB-113

BB-111

BB-111

BB-112BB-111

BB-251

BB-C1

BB-C1

BB-C1

BB-213

BB-212

BB-212A

BB-C1

BB-212BBB-215

BB-237

BB-217A

BB-217

BB-C2

CHIEF

CORR.CORR.

CORR.

MEAT REFRIGERATOR

FREEZER

DRUG

INFOR

SERVICE

CONTROL

SUBSTANCE

DISPENSING

FOOD PROCESSING/

PREPARATION

FOOD SERVICE

COORDINATION

CENTER

STAFF

TOILET

ELEV.

HAC

S-9 MACH.

RM.

LIFT 6

MACH. RM.

STAIR

# 1

LIFT

VESTIBULE

ELEV.

ELEV.

ELEV.

PUBLIC

ELEV

LOBBY

ELEC.

CLOS

TELE

SWITCH

CREDIT UNION

TELLER

AUTO

VALET

ALCOVE

UNIFORM ROOM

CREDIT

UNION

OFFICE

POISON

CONTROL

RECEIVING

CRT

CORR.

CORR.

CORR.

SWITCH BOARD

BC - 261

STAFF

TLT.

BC - 261 A

PHARMACY

ADMIN.

BB - 121

VEST.

BC - C1

STAIR

# 7

ASSOC.

CHIEF

BB - 122

STORAGE BAY 1

STORAGE BAY 2STORAGE BAY 3STORAGE BAY 4STORAGE BAY 5

MEZZANINE STORAGE BAYS 4 & 5 MEZZANINE STORAGE BAY 3 MEZZANINE STORAGE BAY 1

MEZZANINE STORAGE BAY 2

MEZZANINE ABOVE

PHARM

SUPERVISOR

BB - 121A

OPERATIONS

BB-204

EVIDENCE

STORAGE

BB-204A

SECURITY

ROOM

BB-202

INTERVIEW

BB-203

WAITING

HOLDING

BB-C1

CORR.

BB-111A

STORAGE

STORAGE BAY 5

IV

COMPOUND

BB-117

IV

COMPOUND

ANTE-ROOM

BB-120

CHEMO

COMPOUND

ANTE-ROOM

BB-119

CHEMO

COMPOUND

BB-121

IV &

CHEMO

PREP

1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.

2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.

SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED

IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.

3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER

MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA

STANDARDS ON NEAREST ADJACENT WALL.

4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH

STAKEHOLDERS PRIOR TO ORDER AND INSTALL.

5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES

AND VARIATIONS OF SIGN TYPES.

SHADING DENOTES AREAS NOT IN CONTRACT

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-01.10

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-15 IN-02.07

IN-02.08

IN-17.13-.14

IN-17.01-.16

IN-04.03

IN-14.01-.26 IN-01.26-.30 IN-01.26-.30

IN-04.03

IN-15

IN-15

IN-04.03

IN-01.15-.24

IN-01.26-.30

IN-01.31

IN-01.15-.24

IN-04.03

IN-01.15-.24

IN-04.03

IN-04.03

IN-04.03 IN-04.03

IN-15

IN-04.03

IN-01.11

IN-01.26-.30

IN-01.26-.30

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

30% SCHEMATIC

DESIGN

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DISCIPLINE:

FARNSWORTH GROUP

223 WILLOW STREET

FORT COLLINS, CO 80524

970-484-7477

FIRM CONTACT: JULIE SASS

EMAIL: JSASS@F-W.COM

UPGRADE INTERIOR SIGNAGE

AND WAYFINDING

548-23-105

WEST PALM BEACH, FLORIDA

JDP01/13/2023

A u to d e s k D o c s /V

C I W e s t P a lm

B e a c h F a c ili ty /A

V

C I

W e s t

P a lm B e a c h W a y fi n d in g

.0

R

V T

.r v t

/1

/2

:3

:0

A

M

A-100-B.1

PARTIAL BASEMENT FLOOR PLAN

AREA B - NORTH

GENERAL SHEET NOTESSIGNAGE - BASEMENT AREA B - NORTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION Count

BASEMENT NORTH B IN-04.03 - 1

BASEMENT NORTH B BB-111 IN-01.15-.24 - 1

BASEMENT NORTH B BB-111 IN-01.15-.24 - 1

BASEMENT NORTH B BB-111 IN-01.26-.30 - 1

BASEMENT NORTH B BB-111 IN-01.31 - 1

BASEMENT NORTH B BB-111 IN-04.03 - 1

BASEMENT NORTH B BB-111 IN-04.03 - 1

BASEMENT NORTH B BB-111 IN-04.03 - 1

BASEMENT NORTH B BB-111 IN-04.03 - 1

BASEMENT NORTH B BB-112 IN-04.03 - 1

BASEMENT NORTH B BB-113 IN-04.03 - 1

BASEMENT NORTH B BB-115 IN-04.03 - 1

BASEMENT NORTH B BB-116 IN-04.03 - 1

BASEMENT NORTH B BB-118 IN-04.03 - 1

BASEMENT NORTH B BB-118 IN-04.03 - 1

BASEMENT NORTH B BB-121 IN-04.03 - 1

BASEMENT NORTH B BB-121A IN-04.03 - 1

BASEMENT NORTH B BB-122 IN-04.03 - 1

BASEMENT NORTH B BB-123 IN-04.03 - 1

BASEMENT NORTH B BB-125 IN-04.03 - 1

BASEMENT NORTH B BB-125 IN-04.03 - 1

BASEMENT NORTH B BB-212 IN-04.03 - 1

BASEMENT NORTH B BB-213 IN-04.03 - 1

BASEMENT NORTH B CORR. BB-111 IN-01.15-.24 - 1

BASEMENT NORTH B CORR. BB-111 IN-04.03 - 1

SIGNAGE - BASEMENT AREA B - NORTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION Count

BASEMENT NORTH B CORR. BB-C1 IN-02.07 NEAR BB-213 1

BASEMENT NORTH B CORR. BB-C1 IN-02.08 NEAR BB-213 1

BASEMENT NORTH B CORR. BB-C1 IN-15 NEAR CORR.

BB-C2

BASEMENT NORTH B CORR. BB-C1 IN-15 NEAR BB-212 1

BASEMENT NORTH B CORR. BB-C1 IN-15 NEAR BB-111 1

BASEMENT NORTH B CORR. BB-C1 IN-15 NEAR BB-212 1

BASEMENT NORTH B STAIR 1 IN-01.10 - 1

BASEMENT NORTH B STAIR 1 IN-01.11 - 1

BASEMENT NORTH B STAIR 1 IN-01.26-.30 - 1

BASEMENT NORTH B STAIR 1 IN-01.26-.30 - 1

BASEMENT NORTH B VEST. BB-C1 IN-01.26-.30 - 1

BASEMENT NORTH B VEST. BB-C1 IN-01.26-.30 - 1

BASEMENT NORTH B VEST. BB-C1 IN-04.03 - 1

BASEMENT NORTH B VEST. BB-C1 IN-04.03 - 1

BASEMENT NORTH B VEST. BB-C1 IN-14.01-.26 - 1

BASEMENT NORTH B VEST. BB-C1 IN-17.01-.16 - 1

BASEMENT NORTH B VEST. BB-C1 IN-17.13-.14 - 1

GRAND TOTAL: 42

KEY PLAN

SCALE: NOT TO SCALE

D E

A

A B

B

C

C

0 4 8 16 N O

R T H

TRUE

NORTH

S-1

S-2

S-3

S-4

S-5

LIFT 1

LIFT 2

LIFT 3

BB-C1

BB-239

BB-253BB-251

BB-213

BB-212

BB-212A

BB-C1

BB-212BBB-215

BB-237

BB-217A

BB-217

BB-251

BB-251

BB-255

TELECOMM

BB-263

BB-257

BB-251

BB-252

BB-241

BC-247

BB-248

BB-245

BB-243A

BB-249

BB-254

BB-251

BB-251 BB-259

BB-258

BB-256

BB-338

BB-336

BB-334BB-332

BB-C3

BB-324A

BB-235

BB-219B

BB-219

BB-C2

OFFICE

BB-219A

BB-233

BB-251

BB-232

BB-234

BB-251

BB-236 BB-238

BB-242

BB-241

BB-243

BB-225BB-223BB-221ABB-221

BB-322

BB-C3

BB-324

BB-312

BB-314

BB-312ABB-307

BB-316BB-309

CORR.

MEAT REFRIGERATOR

FREEZER

FOOD PROCESSING/

PREPARATION

FOOD SERVICE

COORDINATION

CENTER

ELEC.

CLOS

TELE

SWITCH

CREDIT UNION

TELLER

AUTO

VALET

ALCOVE

UNIFORM ROOM

CREDIT

UNION

OFFICE

CORR.

SUPERVISOR, TECH,

AND CLERKS

CHIEF

LOGISTICS

CORR.

NOURISHMENT

PREPARATION

COOK

FOREMAN

CART

WASH

WARE WASHING

VEST.

ASSISTANT

CHIEF

CORR.

CORR.

N & FS

SUPERVISOR

ADMIN

OFFICER

NUTRITION

& FOOD

SERVICE CHIEF

CAN WASH N & FS TRAINING

MATERIAL

MANAGEMENT

SEAMSTRESS

ELEV.

ELEV.

ELEV.

MECHANICAL

CLEAN

SERVICE

LOBBY

ELEV.

ELEV.

CORR.ELEC.

HACTELE.

CORR.

MACHINE

REPAIR

SHOP

STAIR

# 15

STAIR

# 14

STAIR

#13

DOCK #4

PEST

CONTRO-

LLER

VEST IBULE

CLEANING

EQUIPMENT

ROOM

FOOD

STORAGE

BLAST

CHILLER

CART STORAGE

HAC

SANITARY

SUPPLY

CORR.

DAIRY COOLER

GENERAL COOLER

CORR.

POT WASHING

CORR.

NON-FOOD

STORAGE

PROGRAM

SUPPORT

BATTERY

CHARGE

STAIR

# 6

SWITCH BOARD

EMS SUPPLY

BC - 302

CORR.

BB-C3

CORR.

BC-C3

BC - 261

STAFF

TLT.

BC - 261 A

CORR.

CB -44

CORRIDOR

BD-C1

CORR.

BD-C1

SEAMSTRESS

PEST

CONTRO-

LLER

EMS

REPAIR

AREA

OFFICE OFFICE

OFFICE OFFICE

MANAGER

CHIEF

LOGISTIC

BB-306

STAIR 5

SOILED

SERVICE

LOBBY

BB-302

PNEUMATIC

TUBE

FAN ROOM

BB-302A

VEST.

BA-271

FEMALE

LOCKERS

BA-271

VEST.

BA-271

FEMALE

TOILETS

SHOWERS

BA-271A

VEST.

BA-272

MALE

LOCKERS

BA-272

MALE TLTS.

SHOWERS

BA-272A

VEST.

BA-272

PROGRAM

COORDINATOR

BA-106A

HIMS/MAS

BA-104

CONSOLE ROOM

BB-206

OPERATIONS

ROOM BB-204

EVIDENCE

STORAGE

BB-204A

SECURITY

ROOM

BB-202

CORR.

BB-201STORAGE

BB-209

MANAGEMENT

BA-106B

MAS

ADMIN

SUPERV

BA-103

OFFICE

BB-207

OFFICE

BB-205 INTERVIEW

BB-203

CORR.

LLTS

CORR.

CB-7

CORR.

RECEIVING

HAC

WAITING

SERVICE

MATERIAL

HOLDING

BB-203

REFRIG.

1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.

2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.

SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED

IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.

3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER

MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA

STANDARDS ON NEAREST ADJACENT WALL.

4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH

STAKEHOLDERS PRIOR TO ORDER AND INSTALL.

5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES

AND VARIATIONS OF SIGN TYPES.

SHADING DENOTES AREAS NOT IN CONTRACT

IN-04.03

IN-04.03 IN-04.03

IN-04.03 IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03 IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03 IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03IN-04.03

IN-04.03

IN-04.03

IN-01.10

IN-15

IN-15

IN-15

IN-15

IN-15IN-15

IN-04.03

IN-04.03

IN-04.03

IN-01.10

IN-15

IN-01.10

IN-04.03

IN-04.03

IN-04.03

IN-01.01.01 IN-01.31

IN-15 IN-15

IN-01.15-.24

IN-01.26-.30

IN-15

IN-15

IN-04.03

IN-01.15-.24

IN-15

IN-01.31

IN-01.31

IN-01.01.01

IN-01.01.01 IN-04.03

IN-01.26-.30

IN-01.26-.30

IN-01.31

IN-04.03

IN-01.15-.24

IN-01.31

IN-04.03

IN-01.15-.24

IN-04.03

IN-01.31

IN-01.15-.24

IN-01.31

IN-04.03

IN-04.03

IN-15IN-15

IN-15

IN-01.01.01

IN-04.03

IN-01.31

IN-01.26-.30

IN-01.26-.30

IN-01.26-.30

IN-15

IN-01.15-.24

IN-01.11

IN-01.26-.30

IN-01.26-.30

IN-01.26-.30

IN-01.11

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

30% SCHEMATIC

DESIGN

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DISCIPLINE:

FARNSWORTH GROUP

223 WILLOW STREET

FORT COLLINS, CO 80524

970-484-7477

FIRM CONTACT: JULIE SASS

EMAIL: JSASS@F-W.COM

UPGRADE INTERIOR SIGNAGE

AND WAYFINDING

548-23-105

WEST PALM BEACH, FLORIDA

JDP01/13/2023

A u to d e s k D o c s /V

C I W e s t P a lm

B e a c h F a c ili ty /A

V

C I

W e s t

P a lm B e a c h W a y fi n d in g

.0

R

V T

.r v t

/1

/2

:3

:0

A

M

A-100-B.2

PARTIAL BASEMENT FLOOR PLAN

AREA B - SOUTH

GENERAL SHEET NOTES

KEY PLAN

SCALE: NOT TO SCALE

D E

A

A B

B

C

C

0 4 8 16 N O

R T H

TRUE

NORTH

1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.

2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.

SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED

IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.

3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER

MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA

STANDARDS ON NEAREST ADJACENT WALL.

4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH

STAKEHOLDERS PRIOR TO ORDER AND INSTALL.

5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES

AND VARIATIONS OF SIGN TYPES.

SHADING DENOTES AREAS NOT IN CONTRACT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

30% SCHEMATIC

DESIGN

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DISCIPLINE:

FARNSWORTH GROUP

223 WILLOW STREET

FORT COLLINS, CO 80524

970-484-7477

FIRM CONTACT: JULIE SASS

EMAIL: JSASS@F-W.COM

UPGRADE INTERIOR SIGNAGE

AND WAYFINDING

548-23-105

WEST PALM BEACH, FLORIDA

JDP01/13/2023

A u to d e s k D o c s /V

C I W e s t P a lm

B e a c h F a c ili ty /A

V

C I

W e s t

P a lm B e a c h W a y fi n d in g

.0

R

V T

.r v t

/1

/2

:3

:0

A

M

A-100-B.2.1

PARTIAL BASEMENT FLOOR PLAN

AREA B - SOUTH SCHEDULE

GENERAL SHEET NOTESSIGNAGE - BASEMENT AREA B - SOUTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION COUNT

BASEMENT SOUTH B BA-271 IN-04.03 - 1

BASEMENT SOUTH B BA-271 IN-04.03 - 1

BASEMENT SOUTH B BA-272 IN-04.03 - 1

BASEMENT SOUTH B BB-215 IN-04.03 - 1

BASEMENT SOUTH B BB-217 IN-04.03 - 1

BASEMENT SOUTH B BB-219 IN-04.03 - 1

BASEMENT SOUTH B BB-219A IN-04.03 - 1

BASEMENT SOUTH B BB-219B IN-04.03 - 1

BASEMENT SOUTH B BB-221 IN-04.03 - 1

BASEMENT SOUTH B BB-221A IN-04.03 - 1

BASEMENT SOUTH B BB-223 IN-04.03 - 1

BASEMENT SOUTH B BB-225 IN-04.03 - 1

BASEMENT SOUTH B BB-232 IN-04.03 - 1

BASEMENT SOUTH B BB-233 IN-04.03 - 1

BASEMENT SOUTH B BB-234 IN-04.03 - 1

BASEMENT SOUTH B BB-235 IN-04.03 - 1

BASEMENT SOUTH B BB-236 IN-04.03 - 1

BASEMENT SOUTH B BB-237 IN-04.03 - 1

BASEMENT SOUTH B BB-238 IN-04.03 - 1

BASEMENT SOUTH B BB-239 IN-04.03 - 1

BASEMENT SOUTH B BB-239 IN-04.03 - 1

BASEMENT SOUTH B BB-243 IN-04.03 - 1

BASEMENT SOUTH B BB-245 IN-04.03 - 1

BASEMENT SOUTH B BB-248 IN-04.03 - 1

BASEMENT SOUTH B BB-248 IN-04.03 - 1

BASEMENT SOUTH B BB-251 IN-01.31 NEAR BB-237 1

BASEMENT SOUTH B BB-251 IN-01.31 NEAR CORR. BB-C1 1

BASEMENT SOUTH B BB-253 IN-04.03 - 1

BASEMENT SOUTH B BB-254 IN-04.03 - 1

BASEMENT SOUTH B BB-255 IN-04.03 - 1

BASEMENT SOUTH B BB-256 IN-04.03 - 1

BASEMENT SOUTH B BB-257 IN-04.03 - 1

BASEMENT SOUTH B BB-258 IN-04.03 - 1

BASEMENT SOUTH B BB-259 IN-04.03 - 1

BASEMENT SOUTH B BB-263 IN-01.15-.24 - 1

BASEMENT SOUTH B BB-263 IN-01.15-.24 - 1

BASEMENT SOUTH B BB-263 IN-01.31 - 1

BASEMENT SOUTH B BB-263 IN-01.31 NEAR BC-261 1

BASEMENT SOUTH B BB-263 IN-04.03 - 1

BASEMENT SOUTH B BB-302 IN-01.15-.24 - 1

BASEMENT SOUTH B BB-302 IN-01.26-.30 - 1

BASEMENT SOUTH B BB-302 IN-15 - 1

BASEMENT SOUTH B BB-306 IN-04.03 - 1

BASEMENT SOUTH B BB-307 IN-04.03 - 1

BASEMENT SOUTH B BB-309 IN-04.03 - 1

BASEMENT SOUTH B BB-312 IN-01.26-.30 - 1

BASEMENT SOUTH B BB-312 IN-01.26-.30 - 1

BASEMENT SOUTH B BB-312 IN-01.26-.30 - 1

BASEMENT SOUTH B BB-312 IN-01.31 - 1

BASEMENT SOUTH B BB-312 IN-04.03 - 1

BASEMENT SOUTH B BB-312 IN-15 NEAR CORR. BB-312A 1

BASEMENT SOUTH B BB-314 IN-04.03 - 1

BASEMENT SOUTH B BB-322 IN-04.03 - 1

BASEMENT SOUTH B BB-324 IN-04.03 - 1

BASEMENT SOUTH B BB-332 IN-04.03 - 1

BASEMENT SOUTH B BB-336 IN-01.26-.30 - 1

BASEMENT SOUTH B BB-336 IN-04.03 - 1

BASEMENT SOUTH B BB-338 IN-04.03 - 1

BASEMENT SOUTH B BC-247 IN-04.03 - 1

BASEMENT SOUTH B BC-261 IN-01.15-.24 - 1

BASEMENT SOUTH B BC-261 IN-04.03 - 1

BASEMENT SOUTH B BD-C1 IN-15 - 1

BASEMENT SOUTH B CORR. BA-C3 IN-01.01.01 NEAR BA-271 1

BASEMENT SOUTH B CORR. BB-251 IN-01.01.01 NEAR BB-241 1

BASEMENT SOUTH B CORR. BB-251 IN-01.15-.24 - 1

BASEMENT SOUTH B CORR. BB-251 IN-01.15-.24 - 1

BASEMENT SOUTH B CORR. BB-251 IN-01.31 NEAR BB-252 1

BASEMENT SOUTH B CORR. BB-251 IN-04.03 - 1

BASEMENT SOUTH B CORR. BB-251 IN-04.03 NEAR CORR. CB-7 1

BASEMENT SOUTH B CORR. BB-251 IN-15 NEAR CORR. BB-C3 1

BASEMENT SOUTH B CORR. BB-C1 IN-01.01.01 NEAR BB-251 1

BASEMENT SOUTH B CORR. BB-C1 IN-01.31 NEAR BB-239 1

BASEMENT SOUTH B CORR. BB-C1 IN-15 NEAR BB-237 1

BASEMENT SOUTH B CORR. BB-C1 IN-15 NEAR BB-118 1

BASEMENT SOUTH B CORR. BB-C2 IN-04.03 NEAR BB-217 1

BASEMENT SOUTH B CORR. BB-C2 IN-15 NEAR CORR. BB-201 1

BASEMENT SOUTH B CORR. BB-C2 IN-15 NEAR BB-217 1

BASEMENT SOUTH B CORR. BB-C3 IN-01.01.01 NEAR BB-324 1

BASEMENT SOUTH B CORR. BB-C3 IN-01.31 NEAR STAIR 6 1

BASEMENT SOUTH B CORR. BB-C3 IN-15 NEAR CORR. CB-7 1

BASEMENT SOUTH B CORR. BB-C3 IN-15 NEAR CORR. CB-7 1

BASEMENT SOUTH B CORR. BB-C3 IN-15 NEAR BB-312 1

BASEMENT SOUTH B CORR. BC-C1 IN-15 - 1

BASEMENT SOUTH B CORR. BD-C1 IN-15 NEAR CORR. BB-312A 1

BASEMENT SOUTH B CORR. CB-7 IN-15 NEAR BB-C3 1

BASEMENT SOUTH B CORR. CB-7 IN-15 NEAR CORR. BA-C1 1

BASEMENT SOUTH B CORR. CB-7 IN-15 NEAR CORR. BB-251 1

BASEMENT SOUTH B DOCK #4 IN-01.10 - 1

BASEMENT SOUTH B DOCK #4 IN-04.03 - 1

BASEMENT SOUTH B STAIR 5 IN-01.10 - 1

BASEMENT SOUTH B STAIR 5 IN-01.11 - 1

BASEMENT SOUTH B STAIR 5 IN-01.26-.30 - 1

BASEMENT SOUTH B STAIR 6 IN-01.10 - 1

BASEMENT SOUTH B STAIR 6 IN-01.11 - 1

BASEMENT SOUTH B STAIR 6 IN-01.26-.30 - 1

BASEMENT SOUTH B STAIR 6 IN-01.26-.30 - 1

BASEMENT SOUTH B VEST. BB-C3 IN-01.26-.30 - 1

BASEMENT SOUTH B VEST. BB-C3 IN-04.03 - 1

GRAND TOTAL: 98

BB -123

CONFERENCE

ROOM

BB-125

CHIEF

COMPUTER

ROOM

SHOP

SUPER

CARPENTARY

SHOP

WORKROOMBC-203 A

ADMIN

OFF./

SEC'Y

BC - 203

PHARMACY

ADMIN.

BB - 121

VEST.

BC - C1

STAIR

# 7

VEST.

BC - C1

MALE

LOCKERS

BC - 101

CORR.

BC - C1

FEMALE

TOILET

BC - 103 A

MALE

TLT.

BC - 101 A

FEMALE

LOCKER

BC - 103

WORKBENCH

ELECTRONIC SHOP

BC - 211

BC - 213 B

BC-211A

BC - 242

VOLUNTEER

RECRUITMENT

BC - 244

BC - 243

REFRIG.

BC -241 B

FREEZER

BC -241 A

SUPPLIES/

VOL.

SERVICE

BC-260

OUTDOOR

RECREATION

STORAGE

BC -261

FREEZER

BC -241

CORR.

BC - C6

ELEV.

P - 7

FUTURE

ELEVATOR

LOBBY

BC- C1

ELEV.

P - 8

ELEV.

P - 9

ELEV.

P - 10

SUPV I.T.

SPEC.

BC - 115

I.T.

BC - 111

I.R.M.S.

TELE.

BC - 111

INFORMATION

SECURITY

OFFICER

BC - 112

CORR.

BC - C1

STAIR

# 9

CHIEF

INFO.

OFFICE

BC-111A

CHIEF

VOL. REC

THERAPY

OFFICE

BC - 114B

STORAGE

BC - 114A

IRMS

STOR.

ELEC

CLOSET

BC-114D

BC - 114 IRMS (IT)

SEE PLANS FOR

NURSING HOME

CARE UNIT

ELEC

CLOSET

BG-130

CORRIDOR

BG - 126

PREP RM

BG - 113

PREP RM

BG - 112

PREP RM

BG - 111

EXIT CORRIDOR

BG - 110

WAITING

ROOM

BG - 109

CLEAN

UTIL.

BG - 115

PATIENT

TOILET

BG - 114

CHIEF

TECH.

BG - 117

CORRIDOR

BG - 107

HOLD

ROOM

BG - 118

HOLD

ROOM

BG - 119

READING

ROOM

BG - 120

MRI

CONTROL

ROOM

BG - 121

MRI

SCANNING

ROOM

BG - 122

MRI

SCANNING

ROOM

BG - 123

RECOVERY

AND

SCREENING

BG - 128

LINEN

ALCOVE

BG - 127

HAC

BG - 129

MRI

SYSTEM

COMPONENT

ROOM

BG - 106

BIOMED

EQUIP.

STORAGE

(NO ROOM

LABEL OR

SIGNAGE)

WAITING

RECEPTION

ELEV.

MACH.

SUPV I.T.

SPEC.

BC - 113

BC-114C

K-4386ANGLESEY C_TOILETS VITREOUS CHINA

1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.

2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.

SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED

IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.

3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER

MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA

STANDARDS ON NEAREST ADJACENT WALL.

4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH

STAKEHOLDERS PRIOR TO ORDER AND INSTALL.

5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES

AND VARIATIONS OF SIGN TYPES.

SHADING DENOTES AREAS NOT IN CONTRACT

131 ON SIGN

IN-01.10

IN-04.03

IN-04.03 IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-04.03

IN-01.10

IN-15

IN-01.26-.30

IN-01.31

IN-02.10

IN-17.13-.14

IN-17.01-.16

IN-15 IN-15

IN-01.26-.30

IN-02.08

IN-02.08

IN-01.10 IN-01.10

IN-02.10

IN-02.08

IN-01.26-.30

IN-04.03

IN-07

IN-01.15-.24

IN-04.03 IN-01.26-.30

IN-01.15-.24

IN-01.31

IN-15

IN-01.11

IN-01.26-.30

IN-01.11

IN-01.26-.30

IN-15 IN-17.01-.16 IN-17.13-.14

IN-01.26-.30

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

30% SCHEMATIC

DESIGN

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DISCIPLINE:

FARNSWORTH GROUP

223 WILLOW STREET

FORT COLLINS, CO 80524

970-484-7477

FIRM CONTACT: JULIE SASS

EMAIL: JSASS@F-W.COM

UPGRADE INTERIOR SIGNAGE

AND WAYFINDING

548-23-105

WEST PALM BEACH, FLORIDA

JDP01/13/2023

A u to d e s k D o c s /V

C I W e s t P a lm

B e a c h F a c ili ty /A

V

C I

W e s t

P a lm B e a c h W a y fi n d in g

.0

R

V T

.r v t

/1

/2

:3

:0

A

M

A-100-C.1

PARTIAL BASEMENT FLOOR PLAN

AREA C - NORTH

GENERAL SHEET NOTESSIGNAGE - BASEMENT AREA C - NORTH

FLOOR LEVEL AREA PLAN

ROOM

NUMBER TAG DESCRIPTION Count

BASEMENT NORTH C BC-11A IN-04.03 - 1

BASEMENT NORTH C BC-112 IN-04.03 - 1

BASEMENT NORTH C BC-112 IN-04.03 - 1

BASEMENT NORTH C BC-112 IN-07 - 1

BASEMENT NORTH C BC-113 IN-04.03 - 1

BASEMENT NORTH C BC-114C IN-04.03 - 1

BASEMENT NORTH C BC-114D IN-01.15-.24 - 1

BASEMENT NORTH C BC-114D IN-04.03 - 1

BASEMENT NORTH C BC-115 IN-04.03 - 1

BASEMENT NORTH C BC-131 IN-04.03 - 1

BASEMENT NORTH C BG-130 IN-04.03 - 1

BASEMENT NORTH C CORR. BC-C1 IN-01.26-.30 NEAR CORR. BG-126 1

BASEMENT NORTH C CORR. BC-C1 IN-01.26-.30 NEAR BC-261 1

BASEMENT NORTH C CORR. BC-C1 IN-01.31 NEAR STAIR 9 1

BASEMENT NORTH C CORR. BC-C1 IN-15 NEAR CORR. BG-126 1

BASEMENT NORTH C CORR. BC-C1 IN-15 NEAR STAIR 9 1

BASEMENT NORTH C CORR. BC-C1 IN-15 NEAR CORR. BC-C6 1

BASEMENT NORTH C CORR. BC-C1 IN-17.01-.16 NEAR BC-261 1

BASEMENT NORTH C CORR. BC-C1 IN-17.13-.14 NEAR BC-261 1

BASEMENT NORTH C…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .