07 548-23-105 Concept Drawings.pdf
PDF 13 MB Posted
- Solicitation number
- 36C24823R0115
About this file
This document contains information for a federal contract opportunity with the Department of Veterans Affairs to upgrade interior signage and wayfinding at the Main Hospital building 1 of the Veterans Health Administration Veterans Integrated Service Network 8. The solicitation number is 36C24823R0115 and is a pre-solicitation notice for a project to develop program requirements for wayfinding, identify points of interest, develop messaging for new and existing signage, demo old signage, and manufacture and install new signage. This is a 100% set-aside for Service Disabled Veteran Owned Small Businesses. Interested parties should review the attached statement of work for more detailed project and response information.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24823R0115 Award Notice.pdf | ||
| 36C24823R0115 Award Notice.pdf | ||
| Limitations on Subcontracting (2 Pages).pdf | ||
| 15b 548-23-105 VA INFORMATION SYSTEM SECURITY.docx | DOCX document | |
| 36C24823R0115 0001.docx | DOCX document | |
| WD SCA 15-4573 12.27.22 (13 Pages).pdf | ||
| Combatting COVID 19 (2 Pages).pdf | ||
| 02 548-23-105 DBB SOW Rev.docx | DOCX document | |
| 15a 548-23-105 Without Clause No Sensitive Data.docx | DOCX document | |
| Presolicitation with Attachments.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
30% SCHEMATIC
DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
DISCIPLINE:
FARNSWORTH GROUP
223 WILLOW STREET
FORT COLLINS, CO 80524
970-484-7477
FIRM CONTACT: JULIE SASS
EMAIL: JSASS@F-W.COM
UPGRADE INTERIOR SIGNAGE
AND WAYFINDING
548-23-105
WEST PALM BEACH, FLORIDA
JDP01/13/2023
A u to d e s k D o c s /V
C I W e s t P a lm
B e a c h F a c ili ty /A
V
C I
W e s t
P a lm B e a c h W a y fi n d in g
.0
R
V T
.r v t
/1
/2
:3
:4
A
M
G-001
COVER
JP
DRAWING LIST
ARCHITECTURAL
G-001 COVER
ARCHITECTURAL
A-100 OVERALL PLAN - BASEMENT FLOOR
A-100-A.1 PARTIAL BASEMENT FLOOR PLAN AREA A - NORTH
A-100-A.2 PARTIAL BASEMENT FLOOR PLAN AREA A - SOUTH
A-100-B.1 PARTIAL BASEMENT FLOOR PLAN AREA B - NORTH
A-100-B.2 PARTIAL BASEMENT FLOOR PLAN AREA B - SOUTH
A-100-B.2.1 PARTIAL BASEMENT FLOOR PLAN AREA B - SOUTH SCHEDULE
A-100-C.1 PARTIAL BASEMENT FLOOR PLAN AREA C - NORTH
A-100-C.2 PARTIAL BASEMENT FLOOR PLAN AREA C - SOUTH
A-100-C.2.1 PARTIAL BASEMENT FLOOR PLAN AREA C - SOUTH SCHEDULE
A-100-D PARTIAL BASEMENT FLOOR PLAN AREA D
A-100-E PARTIAL BASEMENT FLOOR PLAN AREA E
A-101 OVERALL PLAN - 1ST FLOOR
A-101-A.1 PARTIAL 1ST FLOOR PLAN AREA A - NORTH
A-101-A.1.1 PARTIAL 1ST FLOOR PLAN AREA A - NORTH SCHEDULE
A-101-A.2 PARTIAL 1ST FLOOR PLAN AREA A - SOUTH
A-101-B.1 PARTIAL 1ST FLOOR PLAN AREA B - NORTH
A-101-B.2 PARTIAL 1ST FLOOR PLAN AREA B - SOUTH
A-101-B.2.1 PARTIAL 1ST FLOOR PLAN AREA B - SOUTH SCHEDULE
A-101-C.1 PARTIAL 1ST FLOOR PLAN AREA C - NORTH & AREA G
A-101-C.1.1 PARTIAL 1ST FLOOR PLAN AREA C - NORTH & AREA G SCHEDULE
A-101-C.2 PARTIAL 1ST FLOOR PLAN AREA C - SOUTH
A-101-C.2.1 PARTIAL 1ST FLOOR PLAN AREA C - SOUTH SCHEDULE
A-102 OVERALL PLAN - 2ND FLOOR
A-102-A.1 PARTIAL 2ND FLOOR PLAN AREA A - NORTH
A-102-A.2 PARTIAL 2ND FLOOR PLAN AREA A - SOUTH
A-102-A.2.1 PARTIAL 2ND FLOOR PLAN AREA A - SOUTH SCHEDULE
A-102-B.1 PARTIAL 2ND FLOOR PLAN AREA B - NORTH
A-102-B.2 PARTIAL 2ND FLOOR PLAN AREA B - SOUTH
A-102-B.2.1 PARTIAL 2ND FLOOR PLAN AREA B - SOUTH SCHEDULE
A-102-C.1 PARTIAL 2ND FLOOR PLAN AREA C - NORTH
A-102-C.2 PARTIAL 2ND FLOOR PLAN AREA C - SOUTH
A-102-C.2.1 PARTIAL 2ND FLOOR PLAN AREA C - SOUTH SCHEDULE
A-103 OVERALL PLAN - 3RD FLOOR
A-103-A PARTIAL 3RD FLOOR PLAN AREA A
A-103-A.1 PARTIAL 3RD FLOOR PLAN AREA A SCHEDULE
A-103-B PARTIAL 3RD FLOOR PLAN AREA B
A-103-B.1 PARTIAL 3RD FLOOR PLAN AREA B SCHEDULE
A-103-C PARTIAL 3RD FLOOR PLAN AREA C
A-103-C.1 PARTIAL 3RD FLOOR PLAN AREA C SCHEDULE
A-104 OVERALL PLAN - 4TH FLOOR
A-104-A PARTIAL 4TH FLOOR PLAN AREA A
A-104-A.1 PARTIAL 4TH FLOOR PLAN AREA A SCHEDULE
A-104-B PARTIAL 4TH FLOOR PLAN AREA B
A-104-B.1 PARTIAL 4TH FLOOR PLAN AREA B SCHEDULE
A-104-C PARTIAL 4TH FLOOR PLAN AREA C
A-104-C.1 PARTIAL 4TH FLOOR PLAN AREA C SCHEDULE
A-105 OVERALL PLAN - 5TH FLOOR
A-105-A PARTIAL 5TH FLOOR PLAN AREA A
A-105-A.1 PARTIAL 5TH FLOOR PLAN AREA A SCHEDULE
A-105-B PARTIAL 5TH FLOOR PLAN AREA B
A-105-B.1 PARTIAL 5TH FLOOR PLAN AREA B SCHEDULE
A-105-C PARTIAL 5TH FLOOR PLAN AREA C
A-106 OVERALL PLAN - 6TH FLOOR
A-106-A PARTIAL 6TH FLOOR PLAN AREA A
A-106-A.1 PARTIAL 6TH FLOOR PLAN AREA A SCHEDULE
A-106-B PARTIAL 6TH FLOOR PLAN AREA B
A-107 OVERALL PLAN - 7TH FLOOR
A-107-A PARTIAL 7TH FLOOR PLAN AREA A
A-107-B PARTIAL 7TH FLOOR PLAN AREA B
A-107-B.1 PARTIAL 7TH FLOOR PLAN AREA B SCHEDULE
A-108 OVERALL PLAN - 8TH FLOOR
A-108-A PARTIAL 8TH FLOOR PLAN AREA A
A-108-A.1 PARTIAL 8TH FLOOR PLAN AREA A SCHEDULE
A-108-B PARTIAL 8TH FLOOR PLAN AREA B
A-108-B.1 PARTIAL 8TH FLOOR PLAN AREA B SCHEDULE
A-109 OVERALL PLAN - 9TH FLOOR
A-109-A PARTIAL 9TH FLOOR PLAN AREA A
A-109-B PARTIAL 9TH FLOOR PLAN AREA B
A-109-B.1 PARTIAL 9TH FLOOR PLAN AREA B SCHEDULE
A-601 SIGNAGE PRODUCT SCHEDULE
A-602 MANDATORY VA POLICY SIGNS ELEVATIONS AND DETAILS
A-603 CODE AND LIFE SAFETY SIGNS ELEVATIONS AND DETAILS
A-604 INTERIOR SIGNS ELEVATIONS AND DETAILS
A-605 INTERIOR SIGNS ELEVATIONS AND DETAILS
SITE
WEST PALM BEACH VETERANS AFFAIRS
HEALTH CARE SYSTEM -
WAYFINDING AND INTERIOR SIGNAGE
PROJECT INFORMATION
OWNER / DEVELOPER
ARCHITECT
ELECTRICAL
MECHANICAL / PLUMBING
DEPARTMENT OF VETERANS AFFAIRS
ARCHITECT
FARNSWORTH GROUP
223 WILLOW STREET
FORT COLLINS, COLORADO
PHONE: (970) 484-7477
CONTACT: JULIE SASS
EMAIL: JSASS@F-W.COM
1. REFER TO LIFE SAFETY SHEETS FOR LIFE SAFETY INFORMATION.
2. PROJECTS SHALL REMAIN IN COMPLIANCE WITH ALL ASPECTS OF ALL GOVERNING
CODES AND ORDINANCES DURING THE COURSE OF CONSTRUCTION INCLUDING, BUT
NOT LIMITED TO, EXITING, FIRE ALARM SYSTEM(S) SMOKE/FIRE DETECTION
SYSTEM(S), SPRINKLER SYSTEM(S).
3. ALL AREAS TO BE DEMOLISHED OR DISTURBED BY ANY PRODUCT REPLACEMENT
ARE TO BE PATCHED AND PAINTED (OR PREPARED FOR OTHER SCHEDULED FINISH).
IF PAINTING IS REQUIRED, ENTIRE WALL SHALL RECEIVE PAINT TO AVOID MISMATCH
OF COLOR.
4. AT CONSTRUCTION ACCESS, CONTRACTOR TO PROVIDE LABOR AND MATERIALS TO
REPAIR ALL DISTURBED ELEMENTS.
5. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO PROVIDE COMPLETE WORKING
SYSTEMS FOR ALL NEW ELEMENTS AND TO COORDINATE THEIR WORK WITH ALL
OTHER TRADES.
6. STORE MATERIALS IN SUCH A MANNER AS NOT TO OVERSTRESS, OVERLOAD, OR
OTHERWISE PUT AN UNSAFE LOAD ON ANY STRUCTURE DURING CONSTRUCTION.
7. INSTALL ALL WORK IN ACCORDANCE WITH CURRENT APPLICABLE CODES,
PUBLISHED STANDARDS, AND ACCEPTABLE CONSTRUCTION STANDARDS.
8. DETAILS ARE GENERALLY TYPICAL AND ARE NOT TO BE CONSTRUED AS LIMITED TO
THOSE AREAS SPECIFICALLY INDICATED. REVIEW ANY QUESTIONS OR CONFLICTING
INFORMATION WITH THE DESIGN PROFESSIONAL PRIOR TO FABRICATION OR
INSTALLATION.
9. CONTRACTOR SHALL VERIFY DIMENSIONS IN FIELD PRIOR TO BEGINNING
CONSTRUCTION.
10. ALL CONTRACTORS SHALL PROVIDE NEW, UNDAMAGED MATERIALS UNLESS
OTHERWISE SPECIFIED.
11. EACH CONTRACTOR SHALL COORDINATE THEIR WORK WITH ALL OTHER TRADES.
12. DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONS. IF A REQUIRED DIMENSION
IS NOT INDICATED, CONTACT THE ARCHITECT FOR DETERMINATION.
13. EXISTING CONDITION INFORMATION SHOWN WITHIN THE PROJECT AREA IS BASED
ON FIELD OBSERVATION AND EXISTING DRAWING DOCUMENTATION. ALL EXISTING
CONDITION INFORMATION SHOWN OUTSIDE THE PROJECT AREA IS PROVIDED FOR
REFERENCE ONLY AND HAS NOT BEEN FIELD VERIFIED. CONTRACTOR IS
RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS PRIOR TO BEGINNING ANY
NEW WORK AND SHALL BRING AND DISCREPANCIES TO THE ATTENTION OF THE
ARCHITECT/ENGINEER PRIOR TO DEMOLITION AND CONSTRUCTION.
14. REFER TO GENERAL INFORMATION SHEETS FOR SYMBOLS AND ABBREVIATIONS.
15. STORAGE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS IS UNDERSTOOD TO NOT
BE WITHIN THE BUILDING. STORAGE OF ANY MATERIAL IS TO BE IN COMPLIANCE
WITH ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION.
GENERAL NOTESPROJECT LOCATION DRAWING LIST
Revisions: Date:
PHARMACY SERVICE
S-1
S-2
S-3
S-4
S-5
LIFT 1
LIFT 2
LIFT 3
P - 1
P - 2
P - 3 P - 4
P - 5
P - 6
S-9
BB -123
CONFERENCE
ROOM
BB-121
BB-125
BB-121BB-111
BB-116
BB-118
BB-C1
BB-239
BB-253
BB-115BB-104BB-102
BB-113
BB-111
BB-111
BB-112BB-111
BB-251
BB-C1
BB-C1
BB-C1
BB-213
BB-212
BB-212A
BB-C1
BB-212BBB-215
BB-237
BB-217A
BB-217
BB-251
BB-251
BB-255
TELECOMM
BB-263
BB-257
BB-251
BB-252
BB-241
BC-247
BB-248
BB-245
BB-243A
BB-249
BB-254
BB-251
BB-251 BB-259
BB-258
BB-256
BB-338
BB-336
BB-334BB-332
BB-C3
BB-324A
BB-235
BB-219B
BB-219
BB-C2
OFFICE
BB-219A
BB-233
BB-251
BB-232
BB-234
BB-251
BB-236 BB-238
BB-242
BB-241
BB-243
BB-225BB-223BB-221ABB-221
BB-322
BB-C3
BB-324
BB-312
BB-314
BB-312ABB-307
BB-316BB-309
CHIEF
CORR.CORR.
CORR.
MEAT REFRIGERATOR
FREEZER
DRUG
INFOR
SERVICE
CONTROL
SUBSTANCE
DISPENSING
FOOD PROCESSING/
PREPARATION
FOOD SERVICE
COORDINATION
CENTER
STAFF
TOILET
ELEV.
HAC
S-9 MACH.
RM.
LIFT 6
MACH. RM.
STAIR
# 1
LIFT
VESTIBULE
ELEV.
ELEV.
ELEV.
PUBLIC
ELEV
LOBBY
ELEV.
ELEV.
ELEV.
ELEC.
CLOS
TELE
SWITCH
CREDIT UNION
TELLER
AUTO
VALET
ALCOVE
UNIFORM ROOM
CREDIT
UNION
OFFICE
POISON
CONTROL
RECEIVING
CRT
CORR.
CORR.
SUPERVISOR, TECH,
AND CLERKS
CHIEF
LOGISTICS
CORR.
NOURISHMENT
PREPARATION
COOK
FOREMAN
CART
WASH
WARE WASHING
VEST.
ASSISTANT
CHIEF
CORR.
CORR.
N & FS
SUPERVISOR
ADMIN
OFFICER
NUTRITION
& FOOD
SERVICE CHIEF
CAN WASH N & FS TRAINING
MATERIAL
MANAGEMENT
SEAMSTRESS
ELEV.
ELEV.
ELEV.
MECHANICAL
CLEAN
SERVICE
LOBBY
ELEV.
ELEV.
CORR.ELEC.
HACTELE.
CORR.
MACHINE
REPAIR
SHOP
STAIR
# 15
STAIR
# 14
STAIR
#13
DOCK #4
PEST
CONTRO-
LLER
VEST IBULE
CLEANING
EQUIPMENT
ROOM
FOOD
STORAGE
BLAST
CHILLER
CART STORAGE
HAC
SANITARY
SUPPLY
CORR.
DAIRY COOLER
GENERAL COOLER
CORR.
POT WASHING
CORR.
NON-FOOD
STORAGE
PROGRAM
SUPPORT
BATTERY
CHARGE
STAIR
# 6
N O T E
ELECTRICAL
SHOP
COMPUTER
ROOM
SWITCH BOARD
COMPUTER
ROOM
TOOLS
SHOP
SUPER
CARPENTARY
SHOP
WORKROOM
ELEC.
CLOS.
TELE.
UPS
ROOM
EQUIP
TECH.
WORK
BIOMEDICAL
ENGINEERING
BREAK RM
STORAGE
MECHANICAL
BC-314B
TELE.
BC-316
ELECT.
BC-324
MECHANICAL
BC-314A
BIOMEDICAL
ENGINEERING
BC-312
LIFT 8
FUTURE
LIFT 7
CLEAN
SERVICE
LOBBY
ELEV.
S-6
ELEV.
S-7
ELEV.
S-8
STAIR
# 8
CORR.
BB -C4
LAPTOP
SUPPORT
BC - 304
EMS SUPPLY
BC - 302
CORR.
BB-C3
CORR.
BC-C3
ELEVATOR LOBBY
BC- C3
BC- 202A
BC- 218
BC - 261
BC - 202
BIOMEDICAL
ENGINEER
BC - 212
BC-203 A
ADMIN
OFF./
SEC'Y
BC - 203
STAFF
TLT.
BC - 261 A
PHARMACY
ADMIN.
BB - 121
VEST.
BC - C1
STAIR
# 7
VEST.
BC - C1
MALE
LOCKERS
BC - 101
CORR.
BC - C1
FEMALE
TOILET
BC - 103 A
MALE
TLT.
BC - 101 A
FEMALE
LOCKER
BC - 103
WORKBENCH
ELECTRONIC SHOP
BC - 211
BC - 213
BC - 213 A
BC - 213 B
BC-211A
BC - 242
BC - 202(B)
BC - 216
BC - 214
BIO.MED.
REPAIR AND
DEVELOPMENT
BC- 215
BC- 215 A
BC- 231D BC- 231E
TRANSPORTATION
BC - 322
FEMALE
TOILET
BC - 334
LOCKSMITH
SHOP
BC - 336
T/S
BC- 240A
ELEC.
CLOSET
BC- 240
SIGN SHOP
BC - 338
MALE
TOILET
BC - 340 VESTIBULE
BC - C3
DOCK
# 6
STOR.
BC - 360 B
WORKBENCH
BC - 360 A
STORAGE
BC - 360
BC - 352
EMS
SUPER.
BC - 351
CHIEF
EMS
BC - 354
AO
EMS
BC - 356
EMS
ASST. CHIEF
BC - 358
PSA
EMS
BC - 257
EOC
BC - 255
BC - 264
INTERIOR
DESIGN
BC - 253
SAFETY
SUPERVISOR
BC - 239
HAC
BC - 251
SAFETY OFFICE
BC - 250
CORR.
BC - C3
COMPUTER
TRAINING
BC - 248
SAFETY OFFICE
BC - 247
RECREATION
THERAPY
BC - 262
BC - 245
BC - 246
VOLUNTEER
RECRUITMENT
BC - 244
BC - 243
REFRIG.
BC -241 B
FREEZER
BC -241 A
SUPPLIES/
VOL.
SERVICE
BC-260
OUTDOOR
RECREATION
STORAGE
BC -261
COMP.
TRAINING
BC -263
CORR.
BC - C6
CORR.
BC - C4
FREEZER
BC -241
CORR.
BC - C6
CORR.
BC - C4
ELEV.
P - 7
FUTURE
ELEVATOR
LOBBY
BC- C1
ELEV.
P - 8
ELEV.
P - 9
ELEV.
P - 10
SUPV I.T.
SPEC.
BC - 115
I.T.
BC - 111
I.R.M.S.
TELE.
BC - 111
INFORMATION
SECURITY
OFFICER
BC - 112
CORR.
BC - C1
CORR.
BC - C3
CORR.
CB -44
STAIR
# 9
CORR.
BC - C2
OPERATIONS STORAGE
N2 MANIFOLD
N2O MANIFOLD
FIRE PUMP RM.
STAIR
# 22
STAIR
# 23
MECHANICAL
AIR COMPRESSOR
& VACUUM PUMPS
BD - 120
BE - 104
DOMESTIC
WATER
PUMP RM.
BE - 103
MECHANICAL
BD - 123
BE - 123
BOILER ROOM
BE - 121
CONF/TRAINING
ROOM
BE - 116
CONTROL
ROOM
BE - 111
OFFICE
BE - 113
LOCKERS
BE - 114
LOCKERS
BE - 112
M TLT
BE - 112A
F TLT
BE - 114A
GENERATOR RM.
BE - 142
FPL
SWITCH
ROOM
BE - 144
ELECTRICAL
SWITCH GEAR ROOM
BE - 141
CHILLER ROOM
BE - 102
A/C SHOP
BE - 131
BE - 136
BE - 134
BE - 132
CORR.
BE - 110
MECHANICAL
BD-102
LIQUID
SUPPLY
SYSTEM
BD-102
ELECT
BD-108
HAC
BD-106
STORAGE
BD-104
CART WASHER
AREA
BD-101
RECEIVING
BD-101
PROCESSING
AREA
BD-101
SORTING & WASHING AREA
BD-101
FOREMAN
BD-119
BD-119
TEXTILE
CARE
BD-119B
ASS'T
MNGR
BD-119A
REST & LUNCH AREA
BD-117
HAC
BD-111
MEN'S
LOCKER
BD-113
WOMEN'S
LOCKER
BD-115
ASSEMBLY
DISTRIBUTION
BD-101
CORR.
BD-C1
CORRIDOR
BD-117
CORRIDOR
BD-C1
CORR.
CORR.
BD-C1
CORR.
BD-101
VEST.
BD-113 BD-115
CORR.
BD-101
LINEN
HOLED
BD-101
LOADING
DOCKS #7
DOCK 7
LOADING
DOCK 8
SEAMSTRESS
PEST
CONTRO-
LLER
EMERGENCY
DOOR
ADMIN.
SUPP.
ASSIST.
MECH. ROOM
BD-101A
LAUNDRY
STORAGE
ASSOC.
CHIEF
BB - 122
CHIEF
INFO.
OFFICE
BC-111A
CHIEF
VOL. REC
THERAPY
PAINT
SHOP
BC - 342
COMPUTER
TRAINING
RECREATION
THERAPY
BC - 245A
ASST. CHIEF
REC THERAPY
VOLUNTARY
SERVICE
MECH.
CLOSET
BE - 314
EMS
REPAIR
AREA BC-318
BIOMEDICAL
ENGINEERING
WELDING
DEPT.
LOW
WALL
OFFICE
BC - 114B
STORAGE
BC - 114A
IRMS
STOR.
ELEC
CLOSET
BC-114D
BC - 114 IRMS (IT)
(MEZZANINE ABOVE)
(MEZZANINE ABOVE)
(MEZZANINE ABOVE)
OFFICE
BE -111A
STORAGE BAY 1
STORAGE BAY 2STORAGE BAY 3STORAGE BAY 4STORAGE BAY 5
MEZZANINE STORAGE BAYS 4 & 5
FACILITY
MANAGEMENT
SERVICE
(LANDING)
FENCED AREA
OFFICE OFFICE
OFFICE OFFICE
MEZZANINE STORAGE BAY 3 MEZZANINE STORAGE BAY 1
MEZZANINE STORAGE BAY 2
SEE PLANS FOR
NURSING HOME
CARE UNIT
GENERATOR CONTROL
BE - 150
MEZZANINE ABOVE
MEDICAL
GAS ROOM
DOMESTIC
WATER ROOM
BC- 231
BC- 231CBC- 231B
BC- 231A
BC - 266
FACILITY
PLANNER
OFFICE
HAC
BA-229
SPS
LOANER
DELIVERY
BA-232
FEMALE
LOCKERS
BA-234
MALE
LOCKERS
BA-233
MALE
TOILET
BA-233A
FEMALE
TOILET
BA-234A
MALE
LOCKERS
BA-235
MALE
TOILET
BA-235A
CLEAN
RECEIVING &
BREAKOUT
BA-241
ANTE/
GOWNING
RM.
BA-242
FEMALE
TOILET
BA-243A
FEMALE
LOCKERS
BA-243
HAC
BA-249
SPS
ASSISTANT
CHIEF
BA-245
QA
SPECIALIST
BA-244
SPS
ASSISTANT
CHIEF
BA-246
SPS CHIEF
BA-252
LOGISTICS
OFFICE
BA-254
LOGISTICS
OFFICE
BA-254A
PIV
COORD.
BA-261B
PROPERTY
MANAGEMENT
BA-212
LOGISTICS
PROPERTY
MANAGEMENT
BA-208
ASST
CHIEF
HIMS
BA-118
CHIEF
AMBULATORY
CARE
BA-120
ASST.
CHIEF
AMBULATORY
CARE
BA-107
ASST.
CHIEF
MAS
BA-105
VTP
MANAGER
BA-121
BENEFICIAL
TRAVEL
BA-101
PHARM
SUPERVISOR
BB - 121A
ELEC
CLOSET
BG-130
CORRIDOR
BG - 126
PREP RM
BG - 113
PREP RM
BG - 112
PREP RM
BG - 111
EXIT CORRIDOR
BG - 110
WAITING
ROOM
BG - 109
CLEAN
UTIL.
BG - 115
PATIENT
TOILET
BG - 114
CHIEF
TECH.
BG - 117
CORRIDOR
BG - 107
HOLD
ROOM
BG - 118
HOLD
ROOM
BG - 119
READING
ROOM
BG - 120
MRI
CONTROL
ROOM
BG - 121
MRI
SCANNING
ROOM
BG - 122
MRI
SCANNING
ROOM
BG - 123
RECOVERY
AND
SCREENING
BG - 128
LINEN
ALCOVE
BG - 127
HAC
BG - 129
MRI
SYSTEM
COMPONENT
ROOM
BG - 106
CHIEF
HIMS
BA-119
DOCK
LIFT
RECEIVING AND
SHIPPING DOCK
DOCK 1
STAIR 11
DOCK
LEVELER
DOCK
LEVELER
ARCH
ABOVE
OFFICE
STORE-
KEEPER
BA-210
ROLL-UP
DOOR SIZE
10'-0"WX10'-0"H
STORAGE
BA-206
STAFF
TLT.
BA-204
BA-202
DIALYSIS
STORAGE
HAC
SPACE
BA-203
MECHANICAL
BA-302
MED GAS
BA-303
MED GAS
UNPOSTED STOCK
HOLDING AREA
WAREHOUSE
RECEIVING
BA-201
RECEIVING AND
ISSUE AREA
SUBSISTENCE
STORAGE
WAREHOUSE
STORAGE
BA-201
MEDICAL/
GENERAL
STORAGE
STAIR 3
MAIL ROOM
BA-215A
BIOMED
WORKSTATION
BA-201A
DOCK 2
ANTE-
ROOM
BA-304
REFRIGERATED
BODY
HOLDING
BA-304A
LAB/PATH
BA-310
EMS STORAGE
BA-312
CORR.
BA-C4
MECHANICAL
BB-304
CHIEF
LOGISTIC
BB-306
STAIR 5
SOILED
SERVICE
LOBBY
BB-302
PNEUMATIC
TUBE
FAN ROOM
BB-302A
CORR.
BA-C3
VEST.
BA-271
FEMALE
LOCKERS
BA-271
VEST.
BA-271
FEMALE
TOILETS
SHOWERS
BA-271A
VEST.
BA-272
MALE
LOCKERS
BA-272
MALE TLTS.
SHOWERS
BA-272A
VEST.
BA-272
BA-261A
CORR.
BA-C1
BA-108
MATERIAL
MANAGEMENT
BA-106
PROGRAM
COORDINATOR
BA-106A
HIMS/MAS
BA-104
CONSOLE ROOM
BB-206
OPERATIONS
ROOM BB-204
EVIDENCE
STORAGE
BB-204A
SECURITY
ROOM
BB-202
CORR.
BB-201STORAGE
BB-209
MANAGEMENT
BA-106B
MAS
ADMIN
SUPERV
BA-103
OFFICE
BB-207
OFFICE
BB-205 INTERVIEW
BB-203
OFFICE
BA-109
BA-102
SUPPLY/EQUIP.
STORAGE
BA-251
MACHINE
BA-110
TELEPHONE
SWITCHGEAR
BA-112
ELECT
ROOM
BA-114
E.T.O. CYLINDER
STORAGE
BA-223
PREPARATION
ASSEMBLY
BA-251A
ETO
VESTIBULE
BA-223
AUTO
CART
WASH
BA-225
MANUAL
EQUP.
WASH
BA-227
CORR.
BA-221
DECONTAMINATION
ROOM
BA-221
MACH.
ROOM
BA-215B
CORR.
BA-C3
CORR.
BA-C2
AUTO
CART
DRYING
CANTEEN RECEIVING
CORR.
TRASH
CHUTE
ABOVE
PIV
OPERATIONS
BA-261
MEDICAL
RESEARCH
STORAGE
LLTS
CORR.
CB-7
V.P.
DN
CORR.
RECEIVING
HAC
WAITING
SERVICE
OFFICE
BA-261C
MATERIAL
STAIR #2
STAIR 4
ETO
VESTIBULE
BA-223
BA-308
BA-95 BA-97 BA-99
MAIL ROOM
ADMIN
OFFICER
BA-115
ADMIN
OFFICER
BA-116
SUPERVISOR
BA-117
HOLDING
BB-203
BA-301
ADMINISTRATIVE
REFRIG.
BIOMED
EQUIP.
STORAGE
(NO ROOM
LABEL OR
SIGNAGE)
CONF.
WAITING
RECEPTION
BREAK ROOM
BA-263
BA-1024
LOGISTICS
BA-215
ELEV.
MACH.
EMS
STORAGE
BA-306
VESTIBULE
BA-312A
MAS
ADMIN. OFFICES/CUBICLES
CONFERENCE
BA-111
STERILE/
NON-STERILE
STORAGE
AREA
BB-C1
CORR.
BB-111A
STORAGE
STORAGE BAY 5
IV
COMPOUND
BB-117
IV
COMPOUND
ANTE-ROOM
BB-120
CHEMO
COMPOUND
ANTE-ROOM
BB-119
CHEMO
COMPOUND
BB-121
IV &
CHEMO
PREP
SUPV I.T.
SPEC.
BC - 113
BC- 231F
OFFICE
BC- 231G
BE - 104
BC-114C
K-4386ANGLESEY C_TOILETS VITREOUS CHINA
K-3544HIGHLINE C_TOILETS VITREOUS CHINA
K-3544HIG
HLINE
C_TO
ILETS
VITREO
US CHINA
K-3544HIGHLINE C_TOILETS VITREOUS CHINA
K-3544HIGHLINE C_TOILETS VITREOUS CHINA
T RA VE L DI ST AN CE
I NF O RM ATI O N
T1
T3
T2
T5
T4
T6
T8
T7
T9
T10
T11
T12
T13
D1
D2
D3
D4
X2
X1
X3
TO TAL TR AVEL D ISTAN C E TO EXIT = 198'- 0" < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 174'- 1" < 200 FT.
TR AVEL IN SU ITE TO EXIT AC C ESS = 67'- 5" < 100 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 124'- 0" < 200 FT.
TR AVEL IN SU ITE TO EXIT AC C ESS = 98'- 9" < 100 FT.
TR AVEL IN SU ITE TO EXIT ACC ESS = 98'- 10" < 100 FT.
TO TAL TR AVEL D ISTAN CE TO EXIT = 89'- 5" + X2 < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 168'- 9" < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 147'- 4" < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 171'- 0" < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 116'- 10" < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 164'- 9" < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 153'- 4" < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 164'- 5" < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 157'- 3" < 200 FT.
TO TAL TR AVEL D ISTAN C E TO EXIT = 98'- 10" < 200 FT.
D EAD EN D CO R RIDO R = 32'- 9" < 50 FT.
D EAD EN D CO R RIDO R = 22'- 0" < 50 FT.
D EAD EN D CO R RIDO R = 41'- 5" < 50 FT.
D EAD EN D CO R RIDO R = 22'- 8" < 50 FT.
1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.
2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.
SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED
IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.
3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER
MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA
STANDARDS ON NEAREST ADJACENT WALL.
4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH
STAKEHOLDERS PRIOR TO ORDER AND INSTALL.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES
AND VARIATIONS OF SIGN TYPES.
SHADING DENOTES AREAS NOT IN CONTRACT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
30% SCHEMATIC
DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
DISCIPLINE:
FARNSWORTH GROUP
223 WILLOW STREET
FORT COLLINS, CO 80524
970-484-7477
FIRM CONTACT: JULIE SASS
EMAIL: JSASS@F-W.COM
UPGRADE INTERIOR SIGNAGE
AND WAYFINDING
548-23-105
WEST PALM BEACH, FLORIDA
JDP01/13/2023
A u to d e s k D o c s /V
C I W e s t P a lm
B e a c h F a c ili ty /A
V
C I
W e s t
P a lm B e a c h W a y fi n d in g
.0
R
V T
.r v t
/1
/2
:3
:5
A
M
A-100
OVERALL PLAN - BASEMENT
FLOOR
GENERAL SHEET NOTES
N O
R T H
TRUE
NORTH
PLAN
P - 1
P - 2
P - 3 P - 4
P - 5
P - 6
BB-C1
BB-C2
ELEV.
ELEV.
ELEV.
PUBLIC
ELEV
LOBBY
ELEV.
ELEV.
ELEV.
CORR.
EMERGENCY
DOOR
ASST
CHIEF
HIMS
BA-118
CHIEF
AMBULATORY
CARE
BA-120
ASST.
CHIEF
AMBULATORY
CARE
BA-107
ASST.
CHIEF
MAS
BA-105
VTP
MANAGER
BA-121
BENEFICIAL
TRAVEL
BA-101
CHIEF
HIMS
BA-119
DIALYSIS
STORAGE
SPACE
BA-203
SUBSISTENCE
STORAGE
WAREHOUSE
STORAGE
BA-201
MEDICAL/
GENERAL
STORAGE
STAIR 3
VEST.
BA-272
CORR.
BA-C1
BA-108
MATERIAL
MANAGEMENT
BA-106
PROGRAM
COORDINATOR
BA-106A
HIMS/MAS
BA-104
CONSOLE ROOM
BB-206
OPERATIONS
ROOM BB-204
EVIDENCE
STORAGE
BB-204A
SECURITY
ROOM
BB-202
CORR.
BB-201STORAGE
BB-209
MANAGEMENT
BA-106B
MAS
ADMIN
SUPERV
BA-103
OFFICE
BB-207
OFFICE
BB-205 INTERVIEW
BB-203
OFFICE
BA-109
BA-102
SUPPLY/EQUIP.
STORAGE
BA-251
MACHINE
BA-110
TELEPHONE
SWITCHGEAR
BA-112
ELECT
ROOM
BA-114
E.T.O. CYLINDER
STORAGE
BA-223
PREPARATION
ASSEMBLY
BA-251A
ETO
VESTIBULE
BA-223
AUTO
CART
WASH
BA-225
MANUAL
EQUP.
WASH
BA-227
AUTO
CART
DRYING
MEDICAL
RESEARCH
STORAGE
MATERIAL
STAIR #2
ETO
VESTIBULE
BA-223
BA-95 BA-97 BA-99
ADMIN
OFFICER
BA-115
ADMIN
OFFICER
BA-116
SUPERVISOR
BA-117
HOLDING
BB-203
ADMINISTRATIVE
BA-1024
LOGISTICS
MAS
ADMIN. OFFICES/CUBICLES
CONFERENCE
BA-111
STERILE/
NON-STERILE
STORAGE
AREA
TRAVEL DISTANCE
INFORMATION
T1
T3
T2
T5
T4
T6
T8
T7
T9
T10
T11
T12
T13
D1
D2
D3
D4
X2
X1
X3
T O TAL T R AVEL D ISTAN C E TO EXI T = 198 '- 0" < 200 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 174 '- 1" < 200 FT.
T R AVEL IN SU ITE T O EXIT A C C ESS = 67'- 5" < 100 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 124 '- 0" < 200 FT.
T R AVEL IN SU ITE T O EXIT A C C ESS = 98'- 9" < 100 FT.
T R AVEL I N SU ITE TO EXI T AC C ES S = 98' - 10" < 100 FT.
T O TAL TR AVEL D IS TAN C E T O EXIT = 89'- 5" + X2 < 200 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 168 '- 9" < 200 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 147 '- 4" < 200 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 171 '- 0" < 200 FT.
T O TAL T R AVEL D ISTAN C E TO EXIT = 116'- 1 0" < 2 00 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 164 '- 9" < 200 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 153 '- 4" < 200 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 164 '- 5" < 200 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 157 '- 3" < 200 FT.
T O TAL T R AVEL D ISTAN C E TO EXI T = 98' - 10" < 200 FT.
D EAD EN D C O R R ID O R = 32'- 9" < 50 FT.
D EAD EN D C O R R ID O R = 22'- 0" < 50 FT.
D EAD EN D C O R R ID O R = 41'- 5" < 50 FT.
D EAD EN D C O R R ID O R = 22'- 8" < 50 FT.
1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.
2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.
SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED
IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.
3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER
MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA
STANDARDS ON NEAREST ADJACENT WALL.
4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH
STAKEHOLDERS PRIOR TO ORDER AND INSTALL.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES
AND VARIATIONS OF SIGN TYPES.
SHADING DENOTES AREAS NOT IN CONTRACT
DOOR PERM. OPEN
IN-04.03
IN-04.03
IN-04.03IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03 IN-04.03
IN-01.10
IN-04.03IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-01.15-.24
IN-04.03
IN-04.03
IN-04.03
IN-15
IN-01.01.01
IN-01.31
IN-01.31
IN-01.15-.24
IN-01.31
IN-01.15-.24
IN-01.31
IN-15
IN-04.03
IN-01.15-.24
IN-04.03
IN-01.15-.24
IN-01.26-.30
IN-01.26-.30
IN-01.11
IN-08.02
IN-01.01.01
IN-15
IN-02.08
IN-15
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
30% SCHEMATIC
DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
DISCIPLINE:
FARNSWORTH GROUP
223 WILLOW STREET
FORT COLLINS, CO 80524
970-484-7477
FIRM CONTACT: JULIE SASS
EMAIL: JSASS@F-W.COM
UPGRADE INTERIOR SIGNAGE
AND WAYFINDING
548-23-105
WEST PALM BEACH, FLORIDA
JDP01/13/2023
A u to d e s k D o c s /V
C I W e s t P a lm
B e a c h F a c ili ty /A
V
C I
W e s t
P a lm B e a c h W a y fi n d in g
.0
R
V T
.r v t
/1
/2
:3
:5
A
M
A-100-A.1
PARTIAL BASEMENT FLOOR PLAN
AREA A - NORTH
GENERAL SHEET NOTES
0 4 8 16 KEY PLAN
SCALE: NOT TO SCALE
D E
A
A B
B
C
C
SIGNAGE - BASEMENT AREA A - NORTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION Count
BASEMENT NORTH A BA-101 IN-04.03 - 1
BASEMENT NORTH A BA-101 IN-04.03 - 1
BASEMENT NORTH A BA-102 IN-01.15-.24 NEAR STAIR 2 1
BASEMENT NORTH A BA-102 IN-01.31 NEAR BA-109 1
BASEMENT NORTH A BA-102 IN-01.31 NEAR STAIR 2 1
BASEMENT NORTH A BA-103 IN-04.03 - 1
BASEMENT NORTH A BA-105 IN-04.03 - 1
BASEMENT NORTH A BA-106A IN-04.03 - 1
BASEMENT NORTH A BA-106B IN-04.03 - 1
BASEMENT NORTH A BA-107 IN-04.03 - 1
BASEMENT NORTH A BA-109 IN-04.03 - 1
BASEMENT NORTH A BA-110 IN-04.03 - 1
BASEMENT NORTH A BA-111 IN-04.03 - 1
BASEMENT NORTH A BA-112 IN-04.03 - 1
BASEMENT NORTH A BA-114 IN-04.03 - 1
BASEMENT NORTH A BA-115 IN-04.03 - 1
BASEMENT NORTH A BA-116 IN-04.03 - 1
BASEMENT NORTH A BA-117 IN-04.03 - 1
BASEMENT NORTH A BA-118 IN-04.03 - 1
BASEMENT NORTH A BA-119 IN-04.03 - 1
BASEMENT NORTH A BA-120 IN-04.03 - 1
BASEMENT NORTH A BA-121 IN-04.03 - 1
BASEMENT NORTH A BA-201 IN-01.01.01 - 1
BASEMENT NORTH A BA-201 IN-01.15-.24 - 1
SIGNAGE - BASEMENT AREA A - NORTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION Count
BASEMENT NORTH A BA-201 IN-01.31 NEAR BA-203 1
BASEMENT NORTH A BA-201 IN-01.31 - 1
BASEMENT NORTH A BA-203 IN-04.03 - 1
BASEMENT NORTH A BA-223 IN-04.03 - 1
BASEMENT NORTH A BA-223 IN-04.03 - 1
BASEMENT NORTH A BA-251A IN-15 - 1
BASEMENT NORTH A BA-1024 IN-01.15-.24 - 1
BASEMENT NORTH A BB-203 IN-04.03 - 1
BASEMENT NORTH A BB-205 IN-04.03 - 1
BASEMENT NORTH A BB-207 IN-04.03 - 1
BASEMENT NORTH A BB-209 IN-04.03 - 1
BASEMENT NORTH A CORR. BB-201 IN-01.15-.24 - 1
BASEMENT NORTH A CORR. BB-201 IN-08.02 - 1
BASEMENT NORTH A CORR. BB-C1 IN-01.01.01 NEAR BA-101 1
BASEMENT NORTH A CORR. BB-C1 IN-02.08 NEAR BA-101 1
BASEMENT NORTH A CORR. BB-C1 IN-15 NEAR BA-101 1
BASEMENT NORTH A CORR. BB-C1 IN-15 NEAR BA-101 1
BASEMENT NORTH A CORR. BB-C1 IN-15 NEAR BA-101 1
BASEMENT NORTH A STAIR 2 IN-01.10 - 1
BASEMENT NORTH A STAIR 2 IN-01.11 - 1
BASEMENT NORTH A STAIR 2 IN-01.15-.24 - 1
BASEMENT NORTH A STAIR 2 IN-01.26-.30 - 1
BASEMENT NORTH A STAIR 2 IN-01.26-.30 - 1
GRAND TOTAL: 47
N O
R T H
TRUE
NORTH
BB-C2
CORR.
HAC
BA-229
SPS
LOANER
DELIVERY
BA-232
FEMALE
LOCKERS
BA-234
MALE
LOCKERS
BA-233
MALE
TOILET
BA-233A
FEMALE
TOILET
BA-234A
MALE
LOCKERS
BA-235
MALE
TOILET
BA-235A
CLEAN
RECEIVING &
BREAKOUT
BA-241
ANTE/
GOWNING
RM.
BA-242
FEMALE
TOILET
BA-243A
FEMALE
LOCKERS
BA-243
HAC
BA-249
SPS
ASSISTANT
CHIEF
BA-245
QA
SPECIALIST
BA-244
SPS
ASSISTANT
CHIEF
BA-246
SPS CHIEF
BA-252
LOGISTICS
OFFICE
BA-254
LOGISTICS
OFFICE
BA-254A
PIV
COORD.
BA-261B
PROPERTY
MANAGEMENT
BA-212
LOGISTICS
PROPERTY
MANAGEMENT
BA-208
DOCK
LIFT
RECEIVING AND
SHIPPING DOCK
DOCK 1
STAIR 11
DOCK
LEVELER
DOCK
LEVELER
ARCH
ABOVE
OFFICE
STORE-
KEEPER
BA-210
ROLL-UP
DOOR SIZE
10'-0"WX10'-0"H
STORAGE
BA-206
STAFF
TLT.
BA-204
BA-202
DIALYSIS
STORAGE
HAC
MECHANICAL
BA-302
MED GAS
BA-303
MED GAS
UNPOSTED STOCK
HOLDING AREA
WAREHOUSE
RECEIVING
BA-201
RECEIVING AND
ISSUE AREA
SUBSISTENCE
STORAGE
MAIL ROOM
BA-215A
BIOMED
WORKSTATION
BA-201A
DOCK 2
ANTE-
ROOM
BA-304
REFRIGERATED
BODY
HOLDING
BA-304A
LAB/PATH
BA-310
EMS STORAGE
BA-312
CORR.
BA-C4
MECHANICAL
BB-304
PNEUMATIC
TUBE
FAN ROOM
BB-302A
CORR.
BA-C3
VEST.
BA-271
FEMALE
LOCKERS
BA-271
VEST.
BA-271
FEMALE
TOILETS
SHOWERS
BA-271A
VEST.
BA-272
MALE
LOCKERS
BA-272
MALE TLTS.
SHOWERS
BA-272A
VEST.
BA-272
BA-261A
CORR.
BA-C1
BA-108
MATERIAL
MANAGEMENT
BA-106
PROGRAM
COORDINATOR
BA-106A
HIMS/MAS
BA-104
CONSOLE ROOM
BB-206
OPERATIONS
ROOM BB-204
EVIDENCE
STORAGE
BB-204A
SECURITY
ROOM
MANAGEMENT
PREPARATION
ASSEMBLY
BA-251A
ETO
VESTIBULE
BA-223
AUTO
CART
WASH
BA-225
MANUAL
EQUP.
WASH
BA-227
CORR.
BA-221
DECONTAMINATION
ROOM
BA-221
MACH.
ROOM
BA-215B
CORR.
BA-C3
CORR.
BA-C2
AUTO
CART
DRYING
CANTEEN RECEIVING
TRASH
CHUTE
ABOVE
PIV
OPERATIONS
BA-261
MEDICAL
RESEARCH
STORAGE
LLTS
CORR.
CB-7
V.P.
DN
OFFICE
BA-261C
STAIR 4
ETO
BA-308
MAIL ROOM
BA-301
BREAK ROOM
BA-263BA-215
EMS
STORAGE
BA-306
VESTIBULE
BA-312A
STERILE/
NON-STERILE
STORAGE
AREA
K-3544HIGHLINE C_TOILETS VITREOUS CHINA
K-3544HIG
HLINE
C_TO
ILETS
VITREO
US CHINA
K-3544HIGHLINE C_TOILETS VITREOUS CHINA
K-3544
HIGHLINE C_TOILETS VITREOUS CHINA
1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.
2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.
SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED
IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.
3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER
MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA
STANDARDS ON NEAREST ADJACENT WALL.
4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH
STAKEHOLDERS PRIOR TO ORDER AND INSTALL.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES
AND VARIATIONS OF SIGN TYPES.
SHADING DENOTES AREAS NOT IN CONTRACT
304A ON SIGN
IN-04.03
IN-04.03
IN-02.04
IN-01.10 IN-04.03
IN-04.03
IN-04.03IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-09.01
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-09.01
IN-04.03
IN-09.01
IN-01.15-.24
IN-04.03
IN-15
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03IN-04.03
IN-15
IN-04.03IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-15
IN-04.03
IN-01.01.01
IN-01.01.01
IN-04.03
IN-01.15-.24IN-04.03
IN-15 IN-15
IN-04.03
IN-01.31
IN-04.03IN-04.03
IN-01.15-.24 IN-01.15-.24
IN-01.15-.24 IN-01.15-.24
IN-04.03 IN-01.31
IN-01.15-.24
IN-04.03
IN-09.01
IN-01.26-.30
IN-01.15-.24
IN-09.01
IN-04.03
IN-04.03 IN-04.03
IN-04.03
IN-15
IN-15
IN-01.15-.24
IN-15
IN-01.31
IN-04.03
IN-01.15-.24
IN-01.15-.24
IN-01.15-.24
IN-01.26-.30
IN-02.10
IN-02.08
IN-09.01
IN-09.01
IN-15
IN-01.26-.30
IN-01.26-.30
IN-01.26-.30
IN-01.11
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
30% SCHEMATIC
DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
DISCIPLINE:
FARNSWORTH GROUP
223 WILLOW STREET
FORT COLLINS, CO 80524
970-484-7477
FIRM CONTACT: JULIE SASS
EMAIL: JSASS@F-W.COM
UPGRADE INTERIOR SIGNAGE
AND WAYFINDING
548-23-105
WEST PALM BEACH, FLORIDA
JDP01/13/2023
A u to d e s k D o c s /V
C I W e s t P a lm
B e a c h F a c ili ty /A
V
C I
W e s t
P a lm B e a c h W a y fi n d in g
.0
R
V T
.r v t
/1
/2
:3
:0
A
M
A-100-A.2
PARTIAL BASEMENT FLOOR PLAN
AREA A - SOUTH
GENERAL SHEET NOTESSIGNAGE - BASEMENT AREA A - SOUTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION Count
BASEMENT SOUTH A BA-10 IN-04.03 - 1
BASEMENT SOUTH A BA-104 IN-01.15-.24 - 1
BASEMENT SOUTH A BA-104 IN-04.03 - 1
BASEMENT SOUTH A BA-106 IN-04.03 - 1
BASEMENT SOUTH A BA-201 IN-01.01.01 - 1
BASEMENT SOUTH A BA-201 IN-01.31 - 1
BASEMENT SOUTH A BA-201A IN-01.01.01 - 1
BASEMENT SOUTH A BA-201A IN-01.15-.24 - 1
BASEMENT SOUTH A BA-201A IN-01.15-.24 - 1
BASEMENT SOUTH A BA-201A IN-01.15-.24 - 1
BASEMENT SOUTH A BA-201A IN-01.15-.24 - 1
BASEMENT SOUTH A BA-201A IN-02.04 - 1
BASEMENT SOUTH A BA-201A IN-04.03 - 1
BASEMENT SOUTH A BA-201A IN-04.03 - 1
BASEMENT SOUTH A BA-202 IN-04.03 - 1
BASEMENT SOUTH A BA-204 IN-09.01 - 1
BASEMENT SOUTH A BA-206 IN-04.03 - 1
BASEMENT SOUTH A BA-208 IN-04.03 - 1
BASEMENT SOUTH A BA-210 IN-04.03 - 1
BASEMENT SOUTH A BA-212 IN-04.03 - 1
BASEMENT SOUTH A BA-215A IN-04.03 - 1
BASEMENT SOUTH A BA-215B IN-04.03 - 1
BASEMENT SOUTH A BA-221 IN-01.15-.24 - 1
KEY PLAN
SCALE: NOT TO SCALE
D E
A
A B
B
C
C
SIGNAGE - BASEMENT AREA A - SOUTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION Count
BASEMENT SOUTH A BA-221 IN-01.26-.30 NEAR BA-229 1
BASEMENT SOUTH A BA-221 IN-04.03 - 1
BASEMENT SOUTH A BA-223 IN-04.03 - 1
BASEMENT SOUTH A BA-225 IN-04.03 - 1
BASEMENT SOUTH A BA-227 IN-04.03 - 1
BASEMENT SOUTH A BA-229 IN-01.15-.24 - 1
BASEMENT SOUTH A BA-232 IN-04.03 - 1
BASEMENT SOUTH A BA-233 IN-04.03 - 1
BASEMENT SOUTH A BA-233A IN-09.01 - 1
BASEMENT SOUTH A BA-234 IN-04.03 - 1
BASEMENT SOUTH A BA-234A IN-09.01 - 1
BASEMENT SOUTH A BA-235 IN-04.03 - 1
BASEMENT SOUTH A BA-235A IN-09.01 - 1
BASEMENT SOUTH A BA-242 IN-04.03 - 1
BASEMENT SOUTH A BA-243 IN-04.03 - 1
BASEMENT SOUTH A BA-243A IN-09.01 - 1
BASEMENT SOUTH A BA-246 IN-04.03 - 1
BASEMENT SOUTH A BA-251 IN-01.15-.24 - 1
BASEMENT SOUTH A BA-251 IN-04.03 - 1
BASEMENT SOUTH A BA-252 IN-04.03 - 1
BASEMENT SOUTH A BA-254 IN-04.03 - 1
BASEMENT SOUTH A BA-254A IN-01.15-.24 - 1
BASEMENT SOUTH A BA-254A IN-01.15-.24 - 1
SIGNAGE - BASEMENT AREA A - SOUTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION Count
BASEMENT SOUTH A BA-254A IN-04.03 - 1
BASEMENT SOUTH A BA-261 IN-01.15-.24 - 1
BASEMENT SOUTH A BA-261 IN-04.03 - 1
BASEMENT SOUTH A BA-261B IN-04.03 - 1
BASEMENT SOUTH A BA-261C IN-04.03 - 1
BASEMENT SOUTH A BA-263 IN-04.03 - 1
BASEMENT SOUTH A BA-271A IN-09.01 - 1
BASEMENT SOUTH A BA-272 IN-04.03 - 1
BASEMENT SOUTH A BA-272A IN-09.01 - 1
BASEMENT SOUTH A BA-302 IN-04.03 - 1
BASEMENT SOUTH A BA-304 IN-01.15-.24 - 1
BASEMENT SOUTH A BA-304 IN-04.03 - 1
BASEMENT SOUTH A BA-304A IN-04.03 - 1
BASEMENT SOUTH A BA-306 IN-04.03 - 1
BASEMENT SOUTH A BA-308 IN-04.03 - 1
BASEMENT SOUTH A BA-308 IN-04.03 - 1
BASEMENT SOUTH A BA-310 IN-04.03 - 1
BASEMENT SOUTH A BA-312 IN-04.03 - 1
BASEMENT SOUTH A BA-312A IN-04.03 - 1
BASEMENT SOUTH A BC-261A IN-04.03 - 1
BASEMENT SOUTH A CORR. BA-C1 IN-15 NEAR BA-106 1
BASEMENT SOUTH A CORR. BA-C1 IN-15 NEAR BA-272 1
BASEMENT SOUTH A CORR. BA-C2 IN-01.31 NEAR BA-251 1
SIGNAGE - BASEMENT AREA A - SOUTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION Count
BASEMENT SOUTH A CORR. BA-C2 IN-15 NEAR BA-261 1
BASEMENT SOUTH A CORR. BA-C3 IN-01.31 NEAR STAIR 4 1
BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR BA-241 1
BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR CORR.
BA-C2 V.P.
BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR CORR.
BA-C2 V.P.
BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR BA-263 1
BASEMENT SOUTH A CORR. BA-C3 IN-15 NEAR BA-312A 1
BASEMENT SOUTH A CORR. BA-C4 IN-01.26-.30 - 1
BASEMENT SOUTH A CORR. BA-C4 IN-02.08 - 1
BASEMENT SOUTH A CORR. BA-C4 IN-02.10 - 1
BASEMENT SOUTH A CORR. BA-C4 IN-15 NEAR CORR.
BA-C3
BASEMENT SOUTH A STAIR 4 IN-01.10 - 1
BASEMENT SOUTH A STAIR 4 IN-01.11 - 1
BASEMENT SOUTH A STAIR 4 IN-01.26-.30 - 1
BASEMENT SOUTH A STAIR 4 IN-01.26-.30 - 1
BASEMENT SOUTH A STAIR 4 IN-01.26-.30 - 1
GRAND TOTAL: 85
0 4 8 16 N O
R T H
TRUE
NORTH
PHARMACY SERVICE
P - 4
P - 5
P - 6
S-9
BB -123
CONFERENCE
ROOM
BB-121
BB-125
BB-121BB-111
BB-116
BB-118
BB-C1
BB-239
BB-253
BB-115BB-104BB-102
BB-113
BB-111
BB-111
BB-112BB-111
BB-251
BB-C1
BB-C1
BB-C1
BB-213
BB-212
BB-212A
BB-C1
BB-212BBB-215
BB-237
BB-217A
BB-217
BB-C2
CHIEF
CORR.CORR.
CORR.
MEAT REFRIGERATOR
FREEZER
DRUG
INFOR
SERVICE
CONTROL
SUBSTANCE
DISPENSING
FOOD PROCESSING/
PREPARATION
FOOD SERVICE
COORDINATION
CENTER
STAFF
TOILET
ELEV.
HAC
S-9 MACH.
RM.
LIFT 6
MACH. RM.
STAIR
# 1
LIFT
VESTIBULE
ELEV.
ELEV.
ELEV.
PUBLIC
ELEV
LOBBY
ELEC.
CLOS
TELE
SWITCH
CREDIT UNION
TELLER
AUTO
VALET
ALCOVE
UNIFORM ROOM
CREDIT
UNION
OFFICE
POISON
CONTROL
RECEIVING
CRT
CORR.
CORR.
CORR.
SWITCH BOARD
BC - 261
STAFF
TLT.
BC - 261 A
PHARMACY
ADMIN.
BB - 121
VEST.
BC - C1
STAIR
# 7
ASSOC.
CHIEF
BB - 122
STORAGE BAY 1
STORAGE BAY 2STORAGE BAY 3STORAGE BAY 4STORAGE BAY 5
MEZZANINE STORAGE BAYS 4 & 5 MEZZANINE STORAGE BAY 3 MEZZANINE STORAGE BAY 1
MEZZANINE STORAGE BAY 2
MEZZANINE ABOVE
PHARM
SUPERVISOR
BB - 121A
OPERATIONS
BB-204
EVIDENCE
STORAGE
BB-204A
SECURITY
ROOM
BB-202
INTERVIEW
BB-203
WAITING
HOLDING
BB-C1
CORR.
BB-111A
STORAGE
STORAGE BAY 5
IV
COMPOUND
BB-117
IV
COMPOUND
ANTE-ROOM
BB-120
CHEMO
COMPOUND
ANTE-ROOM
BB-119
CHEMO
COMPOUND
BB-121
IV &
CHEMO
PREP
1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.
2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.
SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED
IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.
3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER
MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA
STANDARDS ON NEAREST ADJACENT WALL.
4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH
STAKEHOLDERS PRIOR TO ORDER AND INSTALL.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES
AND VARIATIONS OF SIGN TYPES.
SHADING DENOTES AREAS NOT IN CONTRACT
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-01.10
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-15 IN-02.07
IN-02.08
IN-17.13-.14
IN-17.01-.16
IN-04.03
IN-14.01-.26 IN-01.26-.30 IN-01.26-.30
IN-04.03
IN-15
IN-15
IN-04.03
IN-01.15-.24
IN-01.26-.30
IN-01.31
IN-01.15-.24
IN-04.03
IN-01.15-.24
IN-04.03
IN-04.03
IN-04.03 IN-04.03
IN-15
IN-04.03
IN-01.11
IN-01.26-.30
IN-01.26-.30
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
30% SCHEMATIC
DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
DISCIPLINE:
FARNSWORTH GROUP
223 WILLOW STREET
FORT COLLINS, CO 80524
970-484-7477
FIRM CONTACT: JULIE SASS
EMAIL: JSASS@F-W.COM
UPGRADE INTERIOR SIGNAGE
AND WAYFINDING
548-23-105
WEST PALM BEACH, FLORIDA
JDP01/13/2023
A u to d e s k D o c s /V
C I W e s t P a lm
B e a c h F a c ili ty /A
V
C I
W e s t
P a lm B e a c h W a y fi n d in g
.0
R
V T
.r v t
/1
/2
:3
:0
A
M
A-100-B.1
PARTIAL BASEMENT FLOOR PLAN
AREA B - NORTH
GENERAL SHEET NOTESSIGNAGE - BASEMENT AREA B - NORTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION Count
BASEMENT NORTH B IN-04.03 - 1
BASEMENT NORTH B BB-111 IN-01.15-.24 - 1
BASEMENT NORTH B BB-111 IN-01.15-.24 - 1
BASEMENT NORTH B BB-111 IN-01.26-.30 - 1
BASEMENT NORTH B BB-111 IN-01.31 - 1
BASEMENT NORTH B BB-111 IN-04.03 - 1
BASEMENT NORTH B BB-111 IN-04.03 - 1
BASEMENT NORTH B BB-111 IN-04.03 - 1
BASEMENT NORTH B BB-111 IN-04.03 - 1
BASEMENT NORTH B BB-112 IN-04.03 - 1
BASEMENT NORTH B BB-113 IN-04.03 - 1
BASEMENT NORTH B BB-115 IN-04.03 - 1
BASEMENT NORTH B BB-116 IN-04.03 - 1
BASEMENT NORTH B BB-118 IN-04.03 - 1
BASEMENT NORTH B BB-118 IN-04.03 - 1
BASEMENT NORTH B BB-121 IN-04.03 - 1
BASEMENT NORTH B BB-121A IN-04.03 - 1
BASEMENT NORTH B BB-122 IN-04.03 - 1
BASEMENT NORTH B BB-123 IN-04.03 - 1
BASEMENT NORTH B BB-125 IN-04.03 - 1
BASEMENT NORTH B BB-125 IN-04.03 - 1
BASEMENT NORTH B BB-212 IN-04.03 - 1
BASEMENT NORTH B BB-213 IN-04.03 - 1
BASEMENT NORTH B CORR. BB-111 IN-01.15-.24 - 1
BASEMENT NORTH B CORR. BB-111 IN-04.03 - 1
SIGNAGE - BASEMENT AREA B - NORTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION Count
BASEMENT NORTH B CORR. BB-C1 IN-02.07 NEAR BB-213 1
BASEMENT NORTH B CORR. BB-C1 IN-02.08 NEAR BB-213 1
BASEMENT NORTH B CORR. BB-C1 IN-15 NEAR CORR.
BB-C2
BASEMENT NORTH B CORR. BB-C1 IN-15 NEAR BB-212 1
BASEMENT NORTH B CORR. BB-C1 IN-15 NEAR BB-111 1
BASEMENT NORTH B CORR. BB-C1 IN-15 NEAR BB-212 1
BASEMENT NORTH B STAIR 1 IN-01.10 - 1
BASEMENT NORTH B STAIR 1 IN-01.11 - 1
BASEMENT NORTH B STAIR 1 IN-01.26-.30 - 1
BASEMENT NORTH B STAIR 1 IN-01.26-.30 - 1
BASEMENT NORTH B VEST. BB-C1 IN-01.26-.30 - 1
BASEMENT NORTH B VEST. BB-C1 IN-01.26-.30 - 1
BASEMENT NORTH B VEST. BB-C1 IN-04.03 - 1
BASEMENT NORTH B VEST. BB-C1 IN-04.03 - 1
BASEMENT NORTH B VEST. BB-C1 IN-14.01-.26 - 1
BASEMENT NORTH B VEST. BB-C1 IN-17.01-.16 - 1
BASEMENT NORTH B VEST. BB-C1 IN-17.13-.14 - 1
GRAND TOTAL: 42
KEY PLAN
SCALE: NOT TO SCALE
D E
A
A B
B
C
C
0 4 8 16 N O
R T H
TRUE
NORTH
S-1
S-2
S-3
S-4
S-5
LIFT 1
LIFT 2
LIFT 3
BB-C1
BB-239
BB-253BB-251
BB-213
BB-212
BB-212A
BB-C1
BB-212BBB-215
BB-237
BB-217A
BB-217
BB-251
BB-251
BB-255
TELECOMM
BB-263
BB-257
BB-251
BB-252
BB-241
BC-247
BB-248
BB-245
BB-243A
BB-249
BB-254
BB-251
BB-251 BB-259
BB-258
BB-256
BB-338
BB-336
BB-334BB-332
BB-C3
BB-324A
BB-235
BB-219B
BB-219
BB-C2
OFFICE
BB-219A
BB-233
BB-251
BB-232
BB-234
BB-251
BB-236 BB-238
BB-242
BB-241
BB-243
BB-225BB-223BB-221ABB-221
BB-322
BB-C3
BB-324
BB-312
BB-314
BB-312ABB-307
BB-316BB-309
CORR.
MEAT REFRIGERATOR
FREEZER
FOOD PROCESSING/
PREPARATION
FOOD SERVICE
COORDINATION
CENTER
ELEC.
CLOS
TELE
SWITCH
CREDIT UNION
TELLER
AUTO
VALET
ALCOVE
UNIFORM ROOM
CREDIT
UNION
OFFICE
CORR.
SUPERVISOR, TECH,
AND CLERKS
CHIEF
LOGISTICS
CORR.
NOURISHMENT
PREPARATION
COOK
FOREMAN
CART
WASH
WARE WASHING
VEST.
ASSISTANT
CHIEF
CORR.
CORR.
N & FS
SUPERVISOR
ADMIN
OFFICER
NUTRITION
& FOOD
SERVICE CHIEF
CAN WASH N & FS TRAINING
MATERIAL
MANAGEMENT
SEAMSTRESS
ELEV.
ELEV.
ELEV.
MECHANICAL
CLEAN
SERVICE
LOBBY
ELEV.
ELEV.
CORR.ELEC.
HACTELE.
CORR.
MACHINE
REPAIR
SHOP
STAIR
# 15
STAIR
# 14
STAIR
#13
DOCK #4
PEST
CONTRO-
LLER
VEST IBULE
CLEANING
EQUIPMENT
ROOM
FOOD
STORAGE
BLAST
CHILLER
CART STORAGE
HAC
SANITARY
SUPPLY
CORR.
DAIRY COOLER
GENERAL COOLER
CORR.
POT WASHING
CORR.
NON-FOOD
STORAGE
PROGRAM
SUPPORT
BATTERY
CHARGE
STAIR
# 6
SWITCH BOARD
EMS SUPPLY
BC - 302
CORR.
BB-C3
CORR.
BC-C3
BC - 261
STAFF
TLT.
BC - 261 A
CORR.
CB -44
CORRIDOR
BD-C1
CORR.
BD-C1
SEAMSTRESS
PEST
CONTRO-
LLER
EMS
REPAIR
AREA
OFFICE OFFICE
OFFICE OFFICE
MANAGER
CHIEF
LOGISTIC
BB-306
STAIR 5
SOILED
SERVICE
LOBBY
BB-302
PNEUMATIC
TUBE
FAN ROOM
BB-302A
VEST.
BA-271
FEMALE
LOCKERS
BA-271
VEST.
BA-271
FEMALE
TOILETS
SHOWERS
BA-271A
VEST.
BA-272
MALE
LOCKERS
BA-272
MALE TLTS.
SHOWERS
BA-272A
VEST.
BA-272
PROGRAM
COORDINATOR
BA-106A
HIMS/MAS
BA-104
CONSOLE ROOM
BB-206
OPERATIONS
ROOM BB-204
EVIDENCE
STORAGE
BB-204A
SECURITY
ROOM
BB-202
CORR.
BB-201STORAGE
BB-209
MANAGEMENT
BA-106B
MAS
ADMIN
SUPERV
BA-103
OFFICE
BB-207
OFFICE
BB-205 INTERVIEW
BB-203
CORR.
LLTS
CORR.
CB-7
CORR.
RECEIVING
HAC
WAITING
SERVICE
MATERIAL
HOLDING
BB-203
REFRIG.
1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.
2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.
SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED
IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.
3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER
MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA
STANDARDS ON NEAREST ADJACENT WALL.
4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH
STAKEHOLDERS PRIOR TO ORDER AND INSTALL.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES
AND VARIATIONS OF SIGN TYPES.
SHADING DENOTES AREAS NOT IN CONTRACT
IN-04.03
IN-04.03 IN-04.03
IN-04.03 IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03 IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03 IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03IN-04.03
IN-04.03
IN-04.03
IN-01.10
IN-15
IN-15
IN-15
IN-15
IN-15IN-15
IN-04.03
IN-04.03
IN-04.03
IN-01.10
IN-15
IN-01.10
IN-04.03
IN-04.03
IN-04.03
IN-01.01.01 IN-01.31
IN-15 IN-15
IN-01.15-.24
IN-01.26-.30
IN-15
IN-15
IN-04.03
IN-01.15-.24
IN-15
IN-01.31
IN-01.31
IN-01.01.01
IN-01.01.01 IN-04.03
IN-01.26-.30
IN-01.26-.30
IN-01.31
IN-04.03
IN-01.15-.24
IN-01.31
IN-04.03
IN-01.15-.24
IN-04.03
IN-01.31
IN-01.15-.24
IN-01.31
IN-04.03
IN-04.03
IN-15IN-15
IN-15
IN-01.01.01
IN-04.03
IN-01.31
IN-01.26-.30
IN-01.26-.30
IN-01.26-.30
IN-15
IN-01.15-.24
IN-01.11
IN-01.26-.30
IN-01.26-.30
IN-01.26-.30
IN-01.11
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
30% SCHEMATIC
DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
DISCIPLINE:
FARNSWORTH GROUP
223 WILLOW STREET
FORT COLLINS, CO 80524
970-484-7477
FIRM CONTACT: JULIE SASS
EMAIL: JSASS@F-W.COM
UPGRADE INTERIOR SIGNAGE
AND WAYFINDING
548-23-105
WEST PALM BEACH, FLORIDA
JDP01/13/2023
A u to d e s k D o c s /V
C I W e s t P a lm
B e a c h F a c ili ty /A
V
C I
W e s t
P a lm B e a c h W a y fi n d in g
.0
R
V T
.r v t
/1
/2
:3
:0
A
M
A-100-B.2
PARTIAL BASEMENT FLOOR PLAN
AREA B - SOUTH
GENERAL SHEET NOTES
KEY PLAN
SCALE: NOT TO SCALE
D E
A
A B
B
C
C
0 4 8 16 N O
R T H
TRUE
NORTH
1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.
2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.
SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED
IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.
3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER
MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA
STANDARDS ON NEAREST ADJACENT WALL.
4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH
STAKEHOLDERS PRIOR TO ORDER AND INSTALL.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES
AND VARIATIONS OF SIGN TYPES.
SHADING DENOTES AREAS NOT IN CONTRACT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
30% SCHEMATIC
DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
DISCIPLINE:
FARNSWORTH GROUP
223 WILLOW STREET
FORT COLLINS, CO 80524
970-484-7477
FIRM CONTACT: JULIE SASS
EMAIL: JSASS@F-W.COM
UPGRADE INTERIOR SIGNAGE
AND WAYFINDING
548-23-105
WEST PALM BEACH, FLORIDA
JDP01/13/2023
A u to d e s k D o c s /V
C I W e s t P a lm
B e a c h F a c ili ty /A
V
C I
W e s t
P a lm B e a c h W a y fi n d in g
.0
R
V T
.r v t
/1
/2
:3
:0
A
M
A-100-B.2.1
PARTIAL BASEMENT FLOOR PLAN
AREA B - SOUTH SCHEDULE
GENERAL SHEET NOTESSIGNAGE - BASEMENT AREA B - SOUTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION COUNT
BASEMENT SOUTH B BA-271 IN-04.03 - 1
BASEMENT SOUTH B BA-271 IN-04.03 - 1
BASEMENT SOUTH B BA-272 IN-04.03 - 1
BASEMENT SOUTH B BB-215 IN-04.03 - 1
BASEMENT SOUTH B BB-217 IN-04.03 - 1
BASEMENT SOUTH B BB-219 IN-04.03 - 1
BASEMENT SOUTH B BB-219A IN-04.03 - 1
BASEMENT SOUTH B BB-219B IN-04.03 - 1
BASEMENT SOUTH B BB-221 IN-04.03 - 1
BASEMENT SOUTH B BB-221A IN-04.03 - 1
BASEMENT SOUTH B BB-223 IN-04.03 - 1
BASEMENT SOUTH B BB-225 IN-04.03 - 1
BASEMENT SOUTH B BB-232 IN-04.03 - 1
BASEMENT SOUTH B BB-233 IN-04.03 - 1
BASEMENT SOUTH B BB-234 IN-04.03 - 1
BASEMENT SOUTH B BB-235 IN-04.03 - 1
BASEMENT SOUTH B BB-236 IN-04.03 - 1
BASEMENT SOUTH B BB-237 IN-04.03 - 1
BASEMENT SOUTH B BB-238 IN-04.03 - 1
BASEMENT SOUTH B BB-239 IN-04.03 - 1
BASEMENT SOUTH B BB-239 IN-04.03 - 1
BASEMENT SOUTH B BB-243 IN-04.03 - 1
BASEMENT SOUTH B BB-245 IN-04.03 - 1
BASEMENT SOUTH B BB-248 IN-04.03 - 1
BASEMENT SOUTH B BB-248 IN-04.03 - 1
BASEMENT SOUTH B BB-251 IN-01.31 NEAR BB-237 1
BASEMENT SOUTH B BB-251 IN-01.31 NEAR CORR. BB-C1 1
BASEMENT SOUTH B BB-253 IN-04.03 - 1
BASEMENT SOUTH B BB-254 IN-04.03 - 1
BASEMENT SOUTH B BB-255 IN-04.03 - 1
BASEMENT SOUTH B BB-256 IN-04.03 - 1
BASEMENT SOUTH B BB-257 IN-04.03 - 1
BASEMENT SOUTH B BB-258 IN-04.03 - 1
BASEMENT SOUTH B BB-259 IN-04.03 - 1
BASEMENT SOUTH B BB-263 IN-01.15-.24 - 1
BASEMENT SOUTH B BB-263 IN-01.15-.24 - 1
BASEMENT SOUTH B BB-263 IN-01.31 - 1
BASEMENT SOUTH B BB-263 IN-01.31 NEAR BC-261 1
BASEMENT SOUTH B BB-263 IN-04.03 - 1
BASEMENT SOUTH B BB-302 IN-01.15-.24 - 1
BASEMENT SOUTH B BB-302 IN-01.26-.30 - 1
BASEMENT SOUTH B BB-302 IN-15 - 1
BASEMENT SOUTH B BB-306 IN-04.03 - 1
BASEMENT SOUTH B BB-307 IN-04.03 - 1
BASEMENT SOUTH B BB-309 IN-04.03 - 1
BASEMENT SOUTH B BB-312 IN-01.26-.30 - 1
BASEMENT SOUTH B BB-312 IN-01.26-.30 - 1
BASEMENT SOUTH B BB-312 IN-01.26-.30 - 1
BASEMENT SOUTH B BB-312 IN-01.31 - 1
BASEMENT SOUTH B BB-312 IN-04.03 - 1
BASEMENT SOUTH B BB-312 IN-15 NEAR CORR. BB-312A 1
BASEMENT SOUTH B BB-314 IN-04.03 - 1
BASEMENT SOUTH B BB-322 IN-04.03 - 1
BASEMENT SOUTH B BB-324 IN-04.03 - 1
BASEMENT SOUTH B BB-332 IN-04.03 - 1
BASEMENT SOUTH B BB-336 IN-01.26-.30 - 1
BASEMENT SOUTH B BB-336 IN-04.03 - 1
BASEMENT SOUTH B BB-338 IN-04.03 - 1
BASEMENT SOUTH B BC-247 IN-04.03 - 1
BASEMENT SOUTH B BC-261 IN-01.15-.24 - 1
BASEMENT SOUTH B BC-261 IN-04.03 - 1
BASEMENT SOUTH B BD-C1 IN-15 - 1
BASEMENT SOUTH B CORR. BA-C3 IN-01.01.01 NEAR BA-271 1
BASEMENT SOUTH B CORR. BB-251 IN-01.01.01 NEAR BB-241 1
BASEMENT SOUTH B CORR. BB-251 IN-01.15-.24 - 1
BASEMENT SOUTH B CORR. BB-251 IN-01.15-.24 - 1
BASEMENT SOUTH B CORR. BB-251 IN-01.31 NEAR BB-252 1
BASEMENT SOUTH B CORR. BB-251 IN-04.03 - 1
BASEMENT SOUTH B CORR. BB-251 IN-04.03 NEAR CORR. CB-7 1
BASEMENT SOUTH B CORR. BB-251 IN-15 NEAR CORR. BB-C3 1
BASEMENT SOUTH B CORR. BB-C1 IN-01.01.01 NEAR BB-251 1
BASEMENT SOUTH B CORR. BB-C1 IN-01.31 NEAR BB-239 1
BASEMENT SOUTH B CORR. BB-C1 IN-15 NEAR BB-237 1
BASEMENT SOUTH B CORR. BB-C1 IN-15 NEAR BB-118 1
BASEMENT SOUTH B CORR. BB-C2 IN-04.03 NEAR BB-217 1
BASEMENT SOUTH B CORR. BB-C2 IN-15 NEAR CORR. BB-201 1
BASEMENT SOUTH B CORR. BB-C2 IN-15 NEAR BB-217 1
BASEMENT SOUTH B CORR. BB-C3 IN-01.01.01 NEAR BB-324 1
BASEMENT SOUTH B CORR. BB-C3 IN-01.31 NEAR STAIR 6 1
BASEMENT SOUTH B CORR. BB-C3 IN-15 NEAR CORR. CB-7 1
BASEMENT SOUTH B CORR. BB-C3 IN-15 NEAR CORR. CB-7 1
BASEMENT SOUTH B CORR. BB-C3 IN-15 NEAR BB-312 1
BASEMENT SOUTH B CORR. BC-C1 IN-15 - 1
BASEMENT SOUTH B CORR. BD-C1 IN-15 NEAR CORR. BB-312A 1
BASEMENT SOUTH B CORR. CB-7 IN-15 NEAR BB-C3 1
BASEMENT SOUTH B CORR. CB-7 IN-15 NEAR CORR. BA-C1 1
BASEMENT SOUTH B CORR. CB-7 IN-15 NEAR CORR. BB-251 1
BASEMENT SOUTH B DOCK #4 IN-01.10 - 1
BASEMENT SOUTH B DOCK #4 IN-04.03 - 1
BASEMENT SOUTH B STAIR 5 IN-01.10 - 1
BASEMENT SOUTH B STAIR 5 IN-01.11 - 1
BASEMENT SOUTH B STAIR 5 IN-01.26-.30 - 1
BASEMENT SOUTH B STAIR 6 IN-01.10 - 1
BASEMENT SOUTH B STAIR 6 IN-01.11 - 1
BASEMENT SOUTH B STAIR 6 IN-01.26-.30 - 1
BASEMENT SOUTH B STAIR 6 IN-01.26-.30 - 1
BASEMENT SOUTH B VEST. BB-C3 IN-01.26-.30 - 1
BASEMENT SOUTH B VEST. BB-C3 IN-04.03 - 1
GRAND TOTAL: 98
BB -123
CONFERENCE
ROOM
BB-125
CHIEF
COMPUTER
ROOM
SHOP
SUPER
CARPENTARY
SHOP
WORKROOMBC-203 A
ADMIN
OFF./
SEC'Y
BC - 203
PHARMACY
ADMIN.
BB - 121
VEST.
BC - C1
STAIR
# 7
VEST.
BC - C1
MALE
LOCKERS
BC - 101
CORR.
BC - C1
FEMALE
TOILET
BC - 103 A
MALE
TLT.
BC - 101 A
FEMALE
LOCKER
BC - 103
WORKBENCH
ELECTRONIC SHOP
BC - 211
BC - 213 B
BC-211A
BC - 242
VOLUNTEER
RECRUITMENT
BC - 244
BC - 243
REFRIG.
BC -241 B
FREEZER
BC -241 A
SUPPLIES/
VOL.
SERVICE
BC-260
OUTDOOR
RECREATION
STORAGE
BC -261
FREEZER
BC -241
CORR.
BC - C6
ELEV.
P - 7
FUTURE
ELEVATOR
LOBBY
BC- C1
ELEV.
P - 8
ELEV.
P - 9
ELEV.
P - 10
SUPV I.T.
SPEC.
BC - 115
I.T.
BC - 111
I.R.M.S.
TELE.
BC - 111
INFORMATION
SECURITY
OFFICER
BC - 112
CORR.
BC - C1
STAIR
# 9
CHIEF
INFO.
OFFICE
BC-111A
CHIEF
VOL. REC
THERAPY
OFFICE
BC - 114B
STORAGE
BC - 114A
IRMS
STOR.
ELEC
CLOSET
BC-114D
BC - 114 IRMS (IT)
SEE PLANS FOR
NURSING HOME
CARE UNIT
ELEC
CLOSET
BG-130
CORRIDOR
BG - 126
PREP RM
BG - 113
PREP RM
BG - 112
PREP RM
BG - 111
EXIT CORRIDOR
BG - 110
WAITING
ROOM
BG - 109
CLEAN
UTIL.
BG - 115
PATIENT
TOILET
BG - 114
CHIEF
TECH.
BG - 117
CORRIDOR
BG - 107
HOLD
ROOM
BG - 118
HOLD
ROOM
BG - 119
READING
ROOM
BG - 120
MRI
CONTROL
ROOM
BG - 121
MRI
SCANNING
ROOM
BG - 122
MRI
SCANNING
ROOM
BG - 123
RECOVERY
AND
SCREENING
BG - 128
LINEN
ALCOVE
BG - 127
HAC
BG - 129
MRI
SYSTEM
COMPONENT
ROOM
BG - 106
BIOMED
EQUIP.
STORAGE
(NO ROOM
LABEL OR
SIGNAGE)
WAITING
RECEPTION
ELEV.
MACH.
SUPV I.T.
SPEC.
BC - 113
BC-114C
K-4386ANGLESEY C_TOILETS VITREOUS CHINA
1. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED.
2. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE.
SIGNAGE SHALL BE LOCATED AT LATCH SIDE OF DOOR AND MUST BE MOUNTED
IN ACCORDANCE WITH ALL CURRENT ADA/ABA STANDARDS.
3. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER
MOUNTING STANDARDS, SIGNS SHALL BE INSTALLED PER CURRENT ADA/ABA
STANDARDS ON NEAREST ADJACENT WALL.
4. LOCATIONS, TYPES AND COPY OF ALL SIGNS TO BE VERIFIED WITH
STAKEHOLDERS PRIOR TO ORDER AND INSTALL.
5. REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL DESCRIPTIONS, SIZES
AND VARIATIONS OF SIGN TYPES.
SHADING DENOTES AREAS NOT IN CONTRACT
131 ON SIGN
IN-01.10
IN-04.03
IN-04.03 IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-04.03
IN-01.10
IN-15
IN-01.26-.30
IN-01.31
IN-02.10
IN-17.13-.14
IN-17.01-.16
IN-15 IN-15
IN-01.26-.30
IN-02.08
IN-02.08
IN-01.10 IN-01.10
IN-02.10
IN-02.08
IN-01.26-.30
IN-04.03
IN-07
IN-01.15-.24
IN-04.03 IN-01.26-.30
IN-01.15-.24
IN-01.31
IN-15
IN-01.11
IN-01.26-.30
IN-01.11
IN-01.26-.30
IN-15 IN-17.01-.16 IN-17.13-.14
IN-01.26-.30
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
30% SCHEMATIC
DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
DISCIPLINE:
FARNSWORTH GROUP
223 WILLOW STREET
FORT COLLINS, CO 80524
970-484-7477
FIRM CONTACT: JULIE SASS
EMAIL: JSASS@F-W.COM
UPGRADE INTERIOR SIGNAGE
AND WAYFINDING
548-23-105
WEST PALM BEACH, FLORIDA
JDP01/13/2023
A u to d e s k D o c s /V
C I W e s t P a lm
B e a c h F a c ili ty /A
V
C I
W e s t
P a lm B e a c h W a y fi n d in g
.0
R
V T
.r v t
/1
/2
:3
:0
A
M
A-100-C.1
PARTIAL BASEMENT FLOOR PLAN
AREA C - NORTH
GENERAL SHEET NOTESSIGNAGE - BASEMENT AREA C - NORTH
FLOOR LEVEL AREA PLAN
ROOM
NUMBER TAG DESCRIPTION Count
BASEMENT NORTH C BC-11A IN-04.03 - 1
BASEMENT NORTH C BC-112 IN-04.03 - 1
BASEMENT NORTH C BC-112 IN-04.03 - 1
BASEMENT NORTH C BC-112 IN-07 - 1
BASEMENT NORTH C BC-113 IN-04.03 - 1
BASEMENT NORTH C BC-114C IN-04.03 - 1
BASEMENT NORTH C BC-114D IN-01.15-.24 - 1
BASEMENT NORTH C BC-114D IN-04.03 - 1
BASEMENT NORTH C BC-115 IN-04.03 - 1
BASEMENT NORTH C BC-131 IN-04.03 - 1
BASEMENT NORTH C BG-130 IN-04.03 - 1
BASEMENT NORTH C CORR. BC-C1 IN-01.26-.30 NEAR CORR. BG-126 1
BASEMENT NORTH C CORR. BC-C1 IN-01.26-.30 NEAR BC-261 1
BASEMENT NORTH C CORR. BC-C1 IN-01.31 NEAR STAIR 9 1
BASEMENT NORTH C CORR. BC-C1 IN-15 NEAR CORR. BG-126 1
BASEMENT NORTH C CORR. BC-C1 IN-15 NEAR STAIR 9 1
BASEMENT NORTH C CORR. BC-C1 IN-15 NEAR CORR. BC-C6 1
BASEMENT NORTH C CORR. BC-C1 IN-17.01-.16 NEAR BC-261 1
BASEMENT NORTH C CORR. BC-C1 IN-17.13-.14 NEAR BC-261 1
BASEMENT NORTH C…
This is the start of the file's text. The full file is on GovTribe.