36C24818R0372-000.docx
DOCX document 20 KB Posted
- Solicitation number
- 36C24818R0372
About this file
36C24818R0372 36C24818R0372.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24818R0372-001.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FedBizOpps Presolicitation Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Presolicitation Notice Rev. March 2010 Y Upgrade Central Energy Plant (CEP) at Lake Nona VA Hospital, 675-17-600 33637 36C24818R0372 04-30-2018 N 236220 Department of Veterans Affairs Network Contracting Office 8 (NCO 8) 8875 Hidden River Pkwy Suite 560 Tampa FL 33637 Danny Weger Department of Veterans Affairs Lake Nona VA Hospital 138000 Veterans Way Orlando, Florida 32827
USA
danny.weger@va.gov danny.weger@va.gov
DESCRIPTION:
Contractor shall provide all required design, labor, materials, licenses, and testing to accomplish this project to upgrade the Central Energy Plant at the Lake Nona VA Hospital. Upgrade will consist of Five (5) Elements: 1) Repair and upgrade SCADA system for emergency generators to include conversion to a redundant client-server configuration. 2) Reconfigure Chiller Pump system control interface from Envirosep controls into existing Johnson Controls System. 3) Install Reverse Osmosis water filtration system for hot water boilers and integrate into CEP boiler water feed system. 4) Convert Existing outdoor lighting for Water Storage tank to long-life LED system. 5) Replace existing, faulty 18” water valve used for chilled water flow control.
Project No./Title: 675-17-600/Upgrade Central Energy Plant Work Location: Department of Veterans Affairs (VA) Estimated Target Completion Period: 210 calendars days after Notice to Proceed (NTP) Magnitude of this project is between $500,000 and $1,000,000.00. NAICS 236220 – Commercial and Institutional Building Constructions. Size Standard is $36.5 Million. Product Service Code – Z1DA This is a design-build project/solicitation that will use the trade-off source selection process, providing the best value to the Government. The solicitation will be issued on or about March 20, 2018.
All information for this solicitation will be posted on the Federal Business Opportunities (FBO) web-site at www.fbo.gov At the time of proposal submission, contractors must have current registration/certification in the System for Award Management (SAM) www.SAM.GOV and VetBiz at www.vip.vetbiz.gov . Proposals of contractors not registered/certified in both databases will not be considered for award.
Green Environmental Management System (GEMS) - Contractors selected for award of this contract are expected to be good stewards of the environment by complying with federal, state and local environmental laws and other requirements such as medical center policy and project specifications. In addition contractors should incorporate pollution prevention and waste minimization into operations.
Point of Contact: Danny Weger, Contracting Officer Email: danny.weger@va.gov