36C24726Q0823.docx
DOCX document 17 KB Posted
- Attached to
- 6525--Sonosite Ultrasound System Federal contract opportunity
- Solicitation number
- 36C24726Q0823
About this file
This is a Combined Synopsis/Solicitation Notice for a commercial items purchase order issued by the Department of Veterans Affairs Ralph H. Johnson VA Medical Center in Charleston, South Carolina. The solicitation (36C24726Q0823) is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and seeks quotes for a Fujifilm Sonosite ST Ultrasound System or equivalent for the Nursing 4A Unit. The requirement includes ten CLINs: the main ultrasound system (L31500), small basket accessory (P31897), steep needle profiling (P31199), 12-month Voice Assist software support (P31440), two transducers (C5-1 and L19-5), service manual, user guide on USB, and access to the Sonosite Institute for Point-of-Care Training. The Government intends to award a firm fixed-price purchase order. Quotes must be submitted by August 17, 2026, at 8:00 AM Eastern Time to darius.crane@va.gov with the subject line "ATTENTION: 36C24726Q0823 SONOSITE ULTRASOUND SYSTEM."
Offerors must provide unit and total pricing with SDVOSB verification (VIP-verified), and if quoting an equal item, must include a specification sheet demonstrating compliance with each salient characteristic and provide authorization letters if not the original equipment manufacturer. The ultrasound system must meet comprehensive requirements including point-of-care suitability for ICU/CCU bedside use, DICOM-based communication compatible with VA imaging workflows, Windows 10 IoT Enterprise 2019 LTSC or equivalent operating system, steep needle visualization capability, a minimum 5-year warranty, and strict cybersecurity requirements including FIPS 140-2/1403 validated cryptographic modules, TLS 1.3 over HTTPS, Microsoft BitLocker or equivalent encryption, vendor-supported patching, and operation entirely within the VA network without external cloud reliance. Additionally, the system must include at least 4 consecutive hours of onsite installation and clinical training and access to an online ultrasound education platform with 100 hours of point-of-care ultrasound content.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24726Q0823 0001.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice
| SUBJECT* |
| Sonosite Ultrasound System |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 29403-5799 |
| SOLICITATION NUMBER* |
| 36C24726Q0823 |
| RESPONSE DATE/TIME/ZONE |
| 08-17-2026 08:00 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 45 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| 6525 |
| NAICS CODE* |
| 334510 |
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs Ralph H. Johnson VA Medical Center 109 Bee Street Charleston SC 29403-5799
POINT OF CONTACT*
Contracting Officer Darius Crane darius.crane@va.gov
(843) 577-5011
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
Ralph H. Johnson VAMC
NCO 07
109 Bee Street
Charleston South Carolina
| POSTAL CODE |
| 29401 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
General Information This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.
The Small Business Administration (SBA) has granted a class waiver of the Nonmanufacturer Rule for Electromedical and Electrotherapeutic Apparatus Manufacturing, NAICS code 334510, to include medical ultrasound equipment manufacturing (72 FR 71518, Dec. 20, 2007). Accordingly, an offeror submitting a quotation/offer as a nonmanufacturer for the ultrasound system under this solicitation may supply the product of any size manufacturer and shall be considered small for purposes of this Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside, provided the offeror otherwise meets the nonmanufacturer requirements at 13 CFR 121.406(b) (i.e., is primarily engaged in the retail or wholesale trade, normally sells the type of item being supplied, takes ownership/possession of the item consistent with industry practice, and does not exceed 500 employees).
The Ralph H. Johnson VA Medical Center, Charleston, SC, Nursing 4A Unit, has a requirement for the Fujifilm Sonosite ST Ultrasound System or Equal, meeting all listed salient characteristics.
The Government intends to award a firm‑fixed‑price purchase order.
Provide a Brand Name or Equal quote for the following CLINs:
| CLIN |
| Description |
| Quantity |
| Price |
| 0001 |
| L31500 – Sonosite ST Ultrasound System |
| 1 |
| 0002 |
| P31897 – Small Basket |
| 1 |
| 0003 |
| P31199 – Steep Needle Profiling |
| 1 |
| 0004 |
| P31440 – Sonosite Voice Assist (12 Months) |
| 1 |
| 0005 |
| L23119 – Transducer C5-1 |
| 1 |
| 0006 |
| L23972 – Transducer L19-5 |
| 1 |
| 0007 |
| P27929 – Sonosite ST Service Manual |
| 1 |
| 0008 |
| P31284 – User Guide USB |
| 1 |
| 0009 |
| P27929 – Sonosite ST Service Manual (Duplicate) |
| 1 |
| 0010 |
| Sonosite Institute for Point-of-Care Training Access |
| 1 |
Total:
Salient Characteristics The offered ultrasound system must meet or exceed the following salient characteristics Clinical & Operational Requirements:
• Point‑of‑care ultrasound suitable for ICU/CCU/SICU/MICU bedside use.
• DICOM‑based communication compatible with VA imaging workflows.
• System equivalent to Sonosite ST running Windows 10 IoT Enterprise 2019 LTSC or equivalent.
• Application software equivalent to v4.0.2 with comparable functionality and security.
• Steep needle profiling or equivalent needle‑visualization capability.
• Included small basket accessory or equivalent.
• Voice‑assist functionality (e.g., Sonosite Voice Assist) with minimum 12‑month support.
• Service manual and user guide in electronic format (USB).
• At least 4 consecutive hours of onsite installation and clinical applications training.
• Access to online ultrasound education platform with ≥100 hours of POCUS content.
Transducers:
• One curved array transducer equivalent to C5‑1.
• One high‑frequency linear transducer equivalent to L19‑5.
Warranty Requirements:
• Minimum 5‑year standard warranty on system and transducers.
Cybersecurity Requirements:
• Secure wireless networking using FIPS 140‑2/140‑3 validated cryptographic modules.
• TLS 1.3 over HTTPS for all data in transit (no legacy SSL).
• Support for Microsoft BitLocker or equivalent full‑disk encryption.
• Local sensitive data storage with on‑demand data purging.
• Local logging/audit export capability.
• Operation entirely within VA network without external cloud reliance.
• Single‑IP operation (static/DHCP) with IPv4/IPv6 support.
• Vendor‑supported patching for OS and applications.
• OS‑level executable/script whitelisting support when VA antivirus cannot be installed.
• Passive vulnerability scanning by VA security tools.
Instructions to Offerors
• Provide a quote that includes unit pricing, total pricing, and verification of SDVOSB status (VIP‑verified).
• If you are quoting and equal item provide a spec sheet demonstrating how the offered system meets each salient characteristic.
• Provide authorization letters if you are not the OEM.
• Provide warranty documentation.
Responses must be emailed to darius.crane@va.gov.
Quotes are due no later than August 17, 2026, at 08:00 AM EST.
Subject line of the email MUST state: ATTENTION: 36C24726Q0823 SONOSITE ULTRASOUND SYSTEM
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
File details come from the government source that posted it. Updated .