This document contains questions and answers related to solicitation #36C24724Q0862 for Water Treatment and Chiller Plant Services at the William Jennings Bryan Dorn VAMC in Columbia, SC. The questions cover details about the chiller equipment, cooling towers, boiler system, and Legionella testing requirements. The related federal contract opportunity is solicitation #36C24725Q0026 for Water Treatment and Chiller Plant Services, with a NAICS code of 325998 - All Other Miscellaneous Chemical Product and Preparation Manufacturing. The opportunity is for commercial items, with one award to be made to the vendor providing the lowest price technically acceptable offer. Quotes are due by July 31, 2024, and all questions must be submitted by July 26, 2024. The Statement of Work and other attachments provide additional details. No information about incumbent vendors or pricing will be provided to potential offerors.

View the file

Other files

File Type Posted
36C24725Q0026_1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Regarding solicitation #36C24724Q0862 Water Treatment and Chiller Plant Services - William Jennings Bryan Dorn VAMC - Columia, SC, we would like to submit the following RFIs and request for site walk:

1) Can a site/job walk be scheduled? Thursday Aug 8th at 1100.

A site walk could address most of the following questions.

2) Can you please provide the equipment that requires OEM authorization, typically water treatment does not have equipment manufacturing requirements. None requires OEM authorization.

In regards to Cooling Water Treatment:

3) Can you please provide the number of chillers with tonnage for each chiller? 5 Chillers 3 750 tons and 2 500 tons

4) Can you please provide the number of cooling towers, with gallons volume for each? Two towers. 2 Cell each.

5) Can you please provide the number of separate cooling tower systems, with gallon volumes for each?

Two towers. 2 Cell each.

6) Can you please provide the size of the chilled water system in gallons? 30,000

In regards to the Boiler water Treatment:

7) Can you please please provide the number of boilers with horsepower ratings for each? Main Plant 4 Boilers 3 600 HP, 1 400 HP, out building 3 low pressure water heaters that are listed as boilers.

8) Can you please provide the annual steam production in million lbs of steam? FY23 1/1000 LB 82,492,000

9) Is all steam and chilled water produced in one location, or in multiple steam/chilled water plants?

No. 1 Boiler Plant and 1 Chiller Plant

10) Is the Legionella testing done only in the central plant(s) or in multiple buildings and campuses? Only on Cooling Towers.