Attachment 11 - Drawings Missing From Original.pdf
PDF 940 KB Posted
- Solicitation number
- 36C24724R0018
About this file
This document package includes construction drawings and interior details for an angio-CT suite upgrade project, as well as the related federal contract opportunity notice.
The construction drawings show floor plans, elevations, and details for upgrading angio-CT suites at the Ralph H. Johnson VA Medical Center in Charleston, South Carolina. The drawings depict layouts for mechanical penthouse equipment, interior wall protection, flooring transitions, and patient lift details. The related federal contract opportunity is solicitation number 36C24724R0018 for construction services under contract number 534-CSI-713. The Department of Veterans Affairs Veterans Health Administration VISN 7 is the contracting agency. The solicitation involves upgrading angio-CT suites and includes pricing, response deadlines, and other standard contract and procurement terms.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HIW-1
CR-1
3' -0
HR-1
2' -1
0"
/2
CG-1 CG-1
HIW-1
3' -8
CR-1
/2
CG-1 CG-1
3' -0
3' -0
CR-1
HR-1HIW-1
/2 "2' -1
0"
HR-1
CR-1
HIW-1
3' -0
2'
-1 0"
/2
3' -0
HIW-1
CG-1
HIW-1
/2
3' -0
CR-1
3' -0
HIW-1
CG-1 CG-1
3' -8
HIW-1 CG-1
/2
CR-1
3' -0
/2
HIW-1
CR-1
3' -0
TO
P
O F
H
AN
D R
AI
L
2' -1
0"
6" 6"
6"
5'-0"
ALUMINUM SQUARE EDGE
VERTICAL LEDGE TRIM HIWT-5, AT
DOOR FRAMES ONLY
CORRIDOR CEILING
HEIGHTS COULD VARY
ALUMINUM TOP LEDGE
TRIM HIWT-1, TYP
HR-1
HIW-1
VERTICAL CONNECTIONS TO BE ALUMINUM SQUARE EDGE
DIVIDER TRIM VERTICAL HIWT-4, TYP
NOTE * DIVIDING STRIPS TO BE PLACED AS FOLLOWS AND
BASED OFF OF RUNNING LINEAL FOOT OF WALL LENGTH SEE
BOTTOM CENTERLINE NOTE
ALUMINUM BOTTOM LEDGE TRIM HIWT-2, TYP
BASE, MATERIAL VARIES REFER TO ROOM FINISH SCHEDULE
CONTRACTOR TO START WALL PANEL
INSTALLATION BY CENTERING PANEL TO THE
CENTERLINE OF THE WALL LENGTH. LENGTH
OF PANEL SECTIONS NOT TO EXCEED 5'-0".
CG-1
HIW-1
/2 " 3'
-8
HIW-1
CR-1
Revisions: Date
Drawing Title:
Approved:
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
3/
/2
5:
:1
PM
I-401
INTERIOR ELEVATIONS - WALL
PROTECTION
8 15ELI JK
ANGIO CT SUITE UPGRADE
RALPH H. JOHNSON VAMC
109 BEE ST
CHARLESTON, SC 29401 MARCH 28, 2023
100% CONSTRUCTION DOCUMENTS
534-CSI-71320-399
Scale: 1/4" = 1'-0"1 DIAG IMG PAT HALL D206 EAST Scale: 1/4" = 1'-0"7 HOLDING 1 & HOLDING 2 WEST
Scale: 1/4" = 1'-0"10 DIAG IMG CORR COR2D2 NORTH
Scale: 1/4" = 1'-0"11 DIAG IMG CORR COR2D2 EAST
Scale: 1/4" = 1'-0"3 DIAG IMG PAT HALL D206 WEST
Scale: 1/4" = 1'-0"2 DIAG IMG PAT HALL D206 NORTH
Scale: 1/4" = 1'-0"4 DIAG IMG PAT HALL D206 SOUTH
Scale: 1/4" = 1'-0"6 HOLDING 2 D208A NORTH
Scale: 1/4" = 1'-0"9 TYPICAL ALCOVE SIDE WALL Scale: 3/4" = 1'-0"12 TYPICAL WALL PROTECTION ELEVATION
Scale: 1/4" = 1'-0"5 DIAG IMG PAT HALL ALCOVE D206 EAST
Scale: 1/4" = 1'-0"8 HOLDING 1 D208/DIAG IMG PAT HALL D206 SOUTH
16 17 1/417
L1
CT
EQUIPMENT
ROOM
M305
HYBRID ROOM
EQUIPMENT
HYBRID ROOM EQUIPMENT
IR
R
O O
M E
Q U
IP
M
EN
T
IR AND
HYBRID
EQUIPMENT
ROOM
M303
ELEC
M304
EQUIPMENT
ROOM
M302 VESTIBULE
M301
SE
R
V C
AB
SY
S
C
AB
PD
U
U
PS
D
IS
C O
N
M
15 17 1/2
L.5
P
# KEY NOTES:
Revisions: Date
Drawing Title:
Approved:
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
3/
/2
5:
:0
PM
I-411
MECHANICAL PENTHOUSE EQUIPMENT
PLAN
10 15ELI JK
ANGIO CT SUITE UPGRADE
RALPH H. JOHNSON VAMC
109 BEE ST
CHARLESTON, SC 29401 MARCH 28, 2023
100% CONSTRUCTION DOCUMENTS
534-CSI-71320-399
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
NORTH
0 2 4 8
Scale: 1/4" = 1'-0"1 MECHANICAL PENTHOUSE EQUIPMENT PLAN
1 DASHED EQUIPMENT SHOWN FOR REFERENCE
ONLY, REFERENCE VENDOR EQUIPMENT SHEETS
FOR INFORMATION
CEILING SYSTEM - REF
TO RCP FOR TYPE AND
HEIGHT
F.R.T. WOOD
BLOCKING
MTL. STUD BRACING
TO STRUCTURE ABOVE
AT SPLICES AND
WHERE
RECOMMENDED BY
MANUFACTURER
SCHLUTER - VINPRO-S
TRANSITION
RESINOUS FLOORING
WELDED SHEET FLOORING
ADHESIVE PER
MANUFACTURERS
SPECIFICATIONS
FLOOR TO BE FEATHERED
AND SLOPED TO MEET
WELDED SHEET FLOORING AT
SAME HEIGHT
SUBSTRATE
CEILING AS SCHEDULED
MANUFACTURER REQUIREMENTS
ROD SPACING PER
NOTE: SUPPORTS AND ANCHORAGE FOR LIFT SYSTEMS ARE THE RESPONSIBILITY OF
THE CONTRACTOR AND MANUFACTURER AND MUST BE DESIGNED BY A STRUCTURAL
ENGINEER ENGAGED BY THE MANUFACTURER. THE STRUCTRUAL SUPPORT DESIGN
MUST BE SUBMITTED AS PART OF THE SHOP DRAWINGS.
EXISTING STRUCTURE
THREADED ROD PER
MANUFACTURER
REQUIREMENTS
H-TRACK SUPPORT BY
MANUFACTURER
TRAVEL TRACK
SUPPORT BY
MANUFACTURER
ANCHOR RODS TO
EXISTING
STRUCTURE
SCHLUTER - VINPRO
TRANSITION
EXISTING TERRAZZO
FLOORING
WELDED SHEET
FLOORING
ADHESIVE
STAINLESS STEEL TOP CAP
PREFABRICATED COVE FORM
RESILIENT SHEET FLOORING
AS INDICATED ON PLAN
6" U
N O
ALL SEAMS, COVES, AND CORNERS SHALL BE
SMOOTH TO ALLOW EASE OF CLEANING
MATERIAL AND FINISH AS INDICATED ON PLAN
STAINLESS STEEL TOP CAP
PREFABRICATED COVE FORM
RESINOUS FLOORING AS
INDICATED ON PLAN
6" U
N O
ALL SEAMS, COVES, AND CORNERS SHALL BE
SMOOTH TO ALLOW EASE OF CLEANING
MATERIAL AND FINISH AS
INDICATED ON PLAN
SCHLUTER - VINPRO-S
TRANSITION
EXISTING VCT FLOORING
WELDED SHEET FLOORING
ADHESIVE PER
MANUFACTURERS
SPECIFICATIONS
SUBSTRATE
ADHESIVE PER
MANUFACTURER'S
SPECIFICATIONS
RESILIENT TILE FLOORING
SEALED CONCRETE
SCHLUTER VINPRO-U TRANSITION
NOTE: THREADED RODS SHALL
PENETRATE NEAR EDGES OF TILES
TO ALLOW FOR SIMPLE NOTCHING
OF CEILING TILES AROUND RODS.
THREADED ROD SUPPORT
ACOUSTICAL CEILING TILE
1/ 2"
1/2"
1/ 2"
1/2"
ACCEPTABLE REGION OF
ACOUSTICAL TILE FOR
PENETRATION OF THREADED
ROD, TYPICAL
CEILING GRID
Revisions: Date
Drawing Title:
Approved:
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
3/
/2
5:
:0
PM
I-501
INTERIOR DETAILS
14 15ELI JK
ANGIO CT SUITE UPGRADE
RALPH H. JOHNSON VAMC
109 BEE ST
CHARLESTON, SC 29401 MARCH 28, 2023
100% CONSTRUCTION DOCUMENTS
534-CSI-71320-399
Scale: 1 1/2" = 1'-0"7 CUBICLE CURTAIN TRACK DETAIL
Scale: 1 1/2" = 1'-0"1 RESINOUS TO SHEET FLOORING
Scale: 1 1/2" = 1'-0"8 PATIENT LIFT DETAIL
Scale: 1 1/2" = 1'-0"2 SHEET FLOORING TO EXISTING TERRAZZO Scale: 3" = 1'-0"6 RESILIENT COVE BASE
Scale: 3" = 1'-0"5 RESINOUS COVE BASE
Scale: 1 1/2" = 1'-0"3 SHEET FLOORING TO VCT
Scale: 1 1/2" = 1'-0"4 RESILIENT TILE FLOORING TO CONCRETE
Scale: 1 1/2" = 1'-0"9 PATIENT LIFT PENETRATION DETAIL
| Sheets and Views |
| I-401-Layout1 |
| I-411-Layout1 |
| I-501-Layout1 |
File details come from the government source that posted it. Updated .