Attachment 11 - Drawings Missing From Original.pdf

PDF 940 KB Posted

Attached to
Z2DA--Construction: 534-CSI-713, Angio-CT Suite Upgrades (VA-23-00062238)
Solicitation number
36C24724R0018
Issued by

About this file

This document package includes construction drawings and interior details for an angio-CT suite upgrade project, as well as the related federal contract opportunity notice.

The construction drawings show floor plans, elevations, and details for upgrading angio-CT suites at the Ralph H. Johnson VA Medical Center in Charleston, South Carolina. The drawings depict layouts for mechanical penthouse equipment, interior wall protection, flooring transitions, and patient lift details. The related federal contract opportunity is solicitation number 36C24724R0018 for construction services under contract number 534-CSI-713. The Department of Veterans Affairs Veterans Health Administration VISN 7 is the contracting agency. The solicitation involves upgrading angio-CT suites and includes pricing, response deadlines, and other standard contract and procurement terms.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HIW-1

CR-1

3' -0

HR-1

2' -1

0"

/2

CG-1 CG-1

HIW-1

3' -8

CR-1

/2

CG-1 CG-1

3' -0

3' -0

CR-1

HR-1HIW-1

/2 "2' -1

0"

HR-1

CR-1

HIW-1

3' -0

2'

-1 0"

/2

3' -0

HIW-1

CG-1

HIW-1

/2

3' -0

CR-1

3' -0

HIW-1

CG-1 CG-1

3' -8

HIW-1 CG-1

/2

CR-1

3' -0

/2

HIW-1

CR-1

3' -0

TO

P

O F

H

AN

D R

AI

L

2' -1

0"

6" 6"

6"

5'-0"

ALUMINUM SQUARE EDGE

VERTICAL LEDGE TRIM HIWT-5, AT

DOOR FRAMES ONLY

CORRIDOR CEILING

HEIGHTS COULD VARY

ALUMINUM TOP LEDGE

TRIM HIWT-1, TYP

HR-1

HIW-1

VERTICAL CONNECTIONS TO BE ALUMINUM SQUARE EDGE

DIVIDER TRIM VERTICAL HIWT-4, TYP

NOTE * DIVIDING STRIPS TO BE PLACED AS FOLLOWS AND

BASED OFF OF RUNNING LINEAL FOOT OF WALL LENGTH SEE

BOTTOM CENTERLINE NOTE

ALUMINUM BOTTOM LEDGE TRIM HIWT-2, TYP

BASE, MATERIAL VARIES REFER TO ROOM FINISH SCHEDULE

CONTRACTOR TO START WALL PANEL

INSTALLATION BY CENTERING PANEL TO THE

CENTERLINE OF THE WALL LENGTH. LENGTH

OF PANEL SECTIONS NOT TO EXCEED 5'-0".

CG-1

HIW-1

/2 " 3'

-8

HIW-1

CR-1

Revisions: Date

Drawing Title:

Approved:

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

3/

/2

5:

:1

PM

I-401

INTERIOR ELEVATIONS - WALL

PROTECTION

8 15ELI JK

ANGIO CT SUITE UPGRADE

RALPH H. JOHNSON VAMC

109 BEE ST

CHARLESTON, SC 29401 MARCH 28, 2023

100% CONSTRUCTION DOCUMENTS

534-CSI-71320-399

Scale: 1/4" = 1'-0"1 DIAG IMG PAT HALL D206 EAST Scale: 1/4" = 1'-0"7 HOLDING 1 & HOLDING 2 WEST

Scale: 1/4" = 1'-0"10 DIAG IMG CORR COR2D2 NORTH

Scale: 1/4" = 1'-0"11 DIAG IMG CORR COR2D2 EAST

Scale: 1/4" = 1'-0"3 DIAG IMG PAT HALL D206 WEST

Scale: 1/4" = 1'-0"2 DIAG IMG PAT HALL D206 NORTH

Scale: 1/4" = 1'-0"4 DIAG IMG PAT HALL D206 SOUTH

Scale: 1/4" = 1'-0"6 HOLDING 2 D208A NORTH

Scale: 1/4" = 1'-0"9 TYPICAL ALCOVE SIDE WALL Scale: 3/4" = 1'-0"12 TYPICAL WALL PROTECTION ELEVATION

Scale: 1/4" = 1'-0"5 DIAG IMG PAT HALL ALCOVE D206 EAST

Scale: 1/4" = 1'-0"8 HOLDING 1 D208/DIAG IMG PAT HALL D206 SOUTH

16 17 1/417

L1

CT

EQUIPMENT

ROOM

M305

HYBRID ROOM

EQUIPMENT

HYBRID ROOM EQUIPMENT

IR

R

O O

M E

Q U

IP

M

EN

T

IR AND

HYBRID

EQUIPMENT

ROOM

M303

ELEC

M304

EQUIPMENT

ROOM

M302 VESTIBULE

M301

SE

R

V C

AB

SY

S

C

AB

PD

U

U

PS

D

IS

C O

N

M

15 17 1/2

L.5

P

# KEY NOTES:

Revisions: Date

Drawing Title:

Approved:

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

3/

/2

5:

:0

PM

I-411

MECHANICAL PENTHOUSE EQUIPMENT

PLAN

10 15ELI JK

ANGIO CT SUITE UPGRADE

RALPH H. JOHNSON VAMC

109 BEE ST

CHARLESTON, SC 29401 MARCH 28, 2023

100% CONSTRUCTION DOCUMENTS

534-CSI-71320-399

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"1 MECHANICAL PENTHOUSE EQUIPMENT PLAN

1 DASHED EQUIPMENT SHOWN FOR REFERENCE

ONLY, REFERENCE VENDOR EQUIPMENT SHEETS

FOR INFORMATION

CEILING SYSTEM - REF

TO RCP FOR TYPE AND

HEIGHT

F.R.T. WOOD

BLOCKING

MTL. STUD BRACING

TO STRUCTURE ABOVE

AT SPLICES AND

WHERE

RECOMMENDED BY

MANUFACTURER

SCHLUTER - VINPRO-S

TRANSITION

RESINOUS FLOORING

WELDED SHEET FLOORING

ADHESIVE PER

MANUFACTURERS

SPECIFICATIONS

FLOOR TO BE FEATHERED

AND SLOPED TO MEET

WELDED SHEET FLOORING AT

SAME HEIGHT

SUBSTRATE

CEILING AS SCHEDULED

MANUFACTURER REQUIREMENTS

ROD SPACING PER

NOTE: SUPPORTS AND ANCHORAGE FOR LIFT SYSTEMS ARE THE RESPONSIBILITY OF

THE CONTRACTOR AND MANUFACTURER AND MUST BE DESIGNED BY A STRUCTURAL

ENGINEER ENGAGED BY THE MANUFACTURER. THE STRUCTRUAL SUPPORT DESIGN

MUST BE SUBMITTED AS PART OF THE SHOP DRAWINGS.

EXISTING STRUCTURE

THREADED ROD PER

MANUFACTURER

REQUIREMENTS

H-TRACK SUPPORT BY

MANUFACTURER

TRAVEL TRACK

SUPPORT BY

MANUFACTURER

ANCHOR RODS TO

EXISTING

STRUCTURE

SCHLUTER - VINPRO

TRANSITION

EXISTING TERRAZZO

FLOORING

WELDED SHEET

FLOORING

ADHESIVE

STAINLESS STEEL TOP CAP

PREFABRICATED COVE FORM

RESILIENT SHEET FLOORING

AS INDICATED ON PLAN

6" U

N O

ALL SEAMS, COVES, AND CORNERS SHALL BE

SMOOTH TO ALLOW EASE OF CLEANING

MATERIAL AND FINISH AS INDICATED ON PLAN

STAINLESS STEEL TOP CAP

PREFABRICATED COVE FORM

RESINOUS FLOORING AS

INDICATED ON PLAN

6" U

N O

ALL SEAMS, COVES, AND CORNERS SHALL BE

SMOOTH TO ALLOW EASE OF CLEANING

MATERIAL AND FINISH AS

INDICATED ON PLAN

SCHLUTER - VINPRO-S

TRANSITION

EXISTING VCT FLOORING

WELDED SHEET FLOORING

ADHESIVE PER

MANUFACTURERS

SPECIFICATIONS

SUBSTRATE

ADHESIVE PER

MANUFACTURER'S

SPECIFICATIONS

RESILIENT TILE FLOORING

SEALED CONCRETE

SCHLUTER VINPRO-U TRANSITION

NOTE: THREADED RODS SHALL

PENETRATE NEAR EDGES OF TILES

TO ALLOW FOR SIMPLE NOTCHING

OF CEILING TILES AROUND RODS.

THREADED ROD SUPPORT

ACOUSTICAL CEILING TILE

1/ 2"

1/2"

1/ 2"

1/2"

ACCEPTABLE REGION OF

ACOUSTICAL TILE FOR

PENETRATION OF THREADED

ROD, TYPICAL

CEILING GRID

Revisions: Date

Drawing Title:

Approved:

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

3/

/2

5:

:0

PM

I-501

INTERIOR DETAILS

14 15ELI JK

ANGIO CT SUITE UPGRADE

RALPH H. JOHNSON VAMC

109 BEE ST

CHARLESTON, SC 29401 MARCH 28, 2023

100% CONSTRUCTION DOCUMENTS

534-CSI-71320-399

Scale: 1 1/2" = 1'-0"7 CUBICLE CURTAIN TRACK DETAIL

Scale: 1 1/2" = 1'-0"1 RESINOUS TO SHEET FLOORING

Scale: 1 1/2" = 1'-0"8 PATIENT LIFT DETAIL

Scale: 1 1/2" = 1'-0"2 SHEET FLOORING TO EXISTING TERRAZZO Scale: 3" = 1'-0"6 RESILIENT COVE BASE

Scale: 3" = 1'-0"5 RESINOUS COVE BASE

Scale: 1 1/2" = 1'-0"3 SHEET FLOORING TO VCT

Scale: 1 1/2" = 1'-0"4 RESILIENT TILE FLOORING TO CONCRETE

Scale: 1 1/2" = 1'-0"9 PATIENT LIFT PENETRATION DETAIL

Sheets and Views
I-401-Layout1
I-411-Layout1
I-501-Layout1

File details come from the government source that posted it. Updated .